Domus MURO-13S-B User manual

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
enquiries@domuslighng.com | www.domuslighng.com
Installaon Manual
Note: -The lamp must be installed by professional electrician
-Ensurethepowersupplyisswitchedobeforengthisproduct
-Do not touch the lamp when in use
-Keepawayfromhotsteamandcorrosivegas
MURO-13S
Order Code Product Code Descripon
25003 MURO-13S-B 13WSingleSpotwithSensorBlack/WhiteLED5000K
25004 MURO-13S-S 13WSingleSpotwithSensorSilver/WhiteLED5000K
25005 MURO-13S-W 13WSingleSpotwithSensorWhite/WhiteLED5000K
ThankyouforpurchasingyournewLEDMURO-13SPleasetakethemetoreadandunderstandtheinstrucon
sheet below. Failure to do so may void warranty.
Introducon
TheSecurityLightincorporatesaPIR(PassiveInfraRed)sensingdevicewhichconnuouslyscansapreset
operangzoneandimmediatelyswitchesthelightonwhenitdetectsmovementinthatarea.
Thismeansthatwhenevermovementisdetectedwithintherangeofthesensor,thelightwillswitchon
automacallytoilluminatepathways,steps,paos,porches,orwhateverareayouhaveselectedtolightfor
reasonsofsafety,convenienceorsecurity.
Whilethereismovementwithinrangeoftheunitthelightwillremainon.
Fing your security lamp
• Ideally the security lamp should be mounted 1.8 to 2.5 metres
(6to8)abovethegroundtobescanned.
• Toavoiddamagetounit-donotaimthesensortowardsthesun.
• Toavoidnuisancetriggering,thesensorshouldbedirected
awayfromheatsourcessuchasbarbecues,Air-condioners,
otheroutsidelighng,movingcarsanduevents.
• Toavoidnuisancetriggering,keepingawayfromtheareaof
strongelectromagnecdisturbance.
Detecon Area Setup
Donotaimtowardsreecvesurfacessuchassmoothwhitewalls,
swimmingpools,etc.Thesecuritylampscanningspecicaons
(approximately12metresat180°)mayvaryslightlydependingonthe
mounngheightandlocaon.Thedeteconrangeoftheunitmayalso
alterwithtemperaturechange.Beforeselecngaplacetoinstallyour
security lamp you should note that movement across the scan area is
moreeecvethanmovementdirectlytowardorawayfromthesensor.
Ifmovementismadewalkingdirectlytowardsorawayfromthesensor
andnotacross,theapparentdeteconrangewillbesubstanally
reduced.
appro.180°
D e t e c o n A r e a
12m8m4m
2.5m
Not GoodGood

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
enquiries@domuslighng.com | www.domuslighng.com
Installaon Manual
Yellow/Green(Lamp Wire)
Blue(PIR Wire)
Black(PIR Wire)
Brown(PIR Wire)
Brown(Power Cable)
Yellow/Green(Power Cable)
Blue(Power Cable) Blue(Lamp Wire)
Brown (Lamp Wire)
Wall Mounng Cover
Screws (M3--2pcs)
Screws (M3--2pcs)
Gasket
Rubber Stopper
Lamp Body
Plasc plugs
Power Cable
Cable Anchorage
Fixing Cover Screws(x2) Terminal Block Mounng Wall Screws (2pcs)
Installaon
1. InstallaonbyalicensedelectricianandaccordingtoIECwiringRegulaon.
2. Switchpoweroatthemeterboxandensurethatthereisnopowertothelamp.
3. UnscrewtheFixingCoverScrewsthenremovethecover.
4. RemovetheCableAnchorageandTerminalBlock.
5. Usetheplascbackboxtomarktheposionofscrewholesontomounngsurface.Drillthewallto
depthofabout4cmandtthewallplugs(supplied).Careshouldbetakentoavoiddrillingorscrewing
intoconcealedelectricalwiring.
6. ConnecngthePowerCabletotheTerminalBlock,ensurethecablemustpenetratethrough
theCableGasket.
7. AxthebackboxtothemounngsurfacewithMounngWallScrews(supplied).
8. Re-ttheTerminalBlockandCableAnchorage.
9. Re-tthecover.

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
enquiries@domuslighng.com | www.domuslighng.com
Installaon Manual
Note:
• Pleaseswitchthepoweroandletthelampcoolbeforetouchingthelamp(s).
• Whenadjusnglampholders,ensurethatlampsarenottouchingorincloseproximitytosensorhead
(morethan40mm),heatfromthelamp(s)maydistortthePIRSensorordestroytheplascencloserofPIR
Sensor.
• Loosenlocknutsandscrewsonsensorandlampbeforemakinganyadjustments.
• Do NOTaempttoopenthefasciaofthespotlight,asthiswillvoidwarranty.
Notes for electrician
The security lamp should be wired to its own light switch.
Do not interconnect with other lights on the same switch.
Earth connecon must be required.
Understanding the controls
Adjusng the duraon me:Thelengthofmethatremains
switchedonaeracvaoncanbeadjustedfrom(10±5)seconds
to(4±1)minutes.RotangtheTIMEknob+to-willreducethe
duraonme.
Note:OncethelighthasbeentriggeredbythePIRsensorany
subsequentdeteconwillstartthemedperiodagainfromthe
beginning.
Adjusng the LUX control level:TheLuxcontrolmodulehasa
builtinsensingdevice(photocell)thatdetectsdaylightand
darkness.The()posiondenotesthattheoodlightcanworkat
dayandnight,andthe()posiononlyworkatnight.Youcansetto
operatetheunitatthedesiredlevelbyadjusngtheLUXknob.
Adjusng the sensivity:ThesensivitymeanstheMaximum
distancewhichPIRSensorcanbetriggeredbymovementbody.
TurningtheSENSknob+to-willdecreasethesensivity.
Seng the controls
1. PuttheLuxcontrolknobtolight()posion,turnthewallswitchonandwaithalfaminuteforthecontrol
circuittostabilise.AtthisstageensurethattheTIMEcontrolknobissetatminimumduraon.Thesecurity
lampwillnowswitchonandremainonforabout30seconds(within60seconds).
2. Directthesensortowardthedesiredareatobescannedbyadjusngtheelbowjointandswiveljointon
the sensor arm.
Important:loosenalllocknutsandscrewsonsensorandlampbeforemakinganyadjustments.
3. Haveanotherpersonmoveacrossthecentreoftheareatobescannedandslowlyadjusttheangleofthe
sensorarmunltheunitsensorsthepresenceofthemovingperson,causingthelighttoswitchon.
4. Adjustmecontroltorequiredseng.
5. Tosetthelightlevelatwhichthelightswillautomacallyswitch“on”atnight,turntheLUXcontrolknob
fromdaylighttonight.Ifthelampsarerequiredtoswitchonearlier,e.g.Dusk,waitforthedesiredlight
level,thenslowlyturntheLUXcontrolknobtowardsdaylightwhilesomeonewalksacrossthecentreofthe
areatobedetected.Whentheoodlightsswitchon,releasetheLUXcontrolknob.Youmayneedtomake
furtheradjustmentstoachieveyourideallightlevelseng.
Control Knob
SENSTIME LUX

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
enquiries@domuslighng.com | www.domuslighng.com
Installaon Manual
POWER ON AUTO MODE
MANUAL MODE
1
2
3
How to change into MANUAL OVERRIDE CONTROL MODE
1. Whenpowerison,thePIRdetectorentersintothe“WARM-UP”periodsforabout1minute,then
automacallychangesintoAUTOMODE.
2. DuringAUTOMODE,byswitchingtheON/OFFmainswitchtwicewithin3seconds,andthenswitchingit
onagain,thePIRdetectorwillautomacallychangeintoMANUALMODEfromAUTOMODE.InMANUAL
MODE,theLamp(s)willremainON,notaectedbyduraonmeandLuxcontrollevel.
3. DuringMANUALMODEorAUTOMODE,byswitchingotheON/OFFmainswitchforover6secondsand
thenonagain,thePIRdetectorwillresettoWARM-UPperiods.Pleasenote:theperiodsof“WARM-UP”
maybe shorter than 1 minute.
Specicaons
Deteconrange:Max.12metresat180°scan
DuraonTimeadjustment:(10±5)secondsto(4±1)minutes.
Deteconcircuitry:PassiveInfra-Red(PIR)
Powerrequired:240VAC,50HZ
Maximumload:13WaLED.
Weatherproof:IP44
This manual suits for next models
2
Table of contents