Installation Manual
for
603S & SK Wireless Intercom System
MENU
12.21
Charging
base
Entrance
Pillar
Transmitter / receiver - Keep
away from ground, as high as
possible. For best results, do
not install too close to sources
of electrical interference e.g.
gate automation panel
Speech
Unit
House or
reception
area
Note: Wood and glass only
reduce signal strength by
10-20%. Masonry will reduce
signal strength by 20-50%
per wall. Metal can totally
block signals.
For longer range
applications, locate the
handset near a window at
front of property.
150m
Typical
Installation
1) Before installing fully, test the range of the system. Wire the unit as per
wiring diagram, place the equipment in the desired location and test
operation.
2) Ensure that the gate transmitter / receiver unit is installed to facilitate
line of sight with the property or reception area. To achieve best results,
mount the unit as high as possible from the ground. Should you need to
extend range, you can mount it on a small pole to elevate it a few meters
from the ground.
3) It is recommended to charge the handset for 7-8 hours before use.
4) Power up the handset after inserting the batteries.
5) Wire the door station and transmitter / receiver according to the diagram
below..
Never drill holes in
the top of the
enclosure. Cable
entry should be
through the bottom.
Screened CAT 5
8 meters max 603 Range
Intercom
Transmitter
12v
dc in
+
-
N/C N/O
A/C 12-24v
(optional)
Shielded CAT5 cable
Solid
shield
wire
Relay output
(4 sec pulse)
Code
button
Note: Shield only connects at one end
Testing
1) Check all connections are correct before switching on the power.
2) Press the call button on the speech panel.
3) The handset should ring.
4) Press the button to answer the call and check two way speech.
5) Press to check the door / gate release function works.
Handset & Operation
Power
LED
ON/OFF Vibration
ON/OFF
Voicemail
Symbol
Battery
Level
Reception
indicator
ADJUST VOLUME
Press or to adjust volume level,
and press MENU to select and save.
CHANGE RING TONE
Press and the unit will ring under
the currently select tone. Press
and to cycle through available
ring tones. Press MENU to select
and save.
CHANGE LANGUAGE
Press and the unit will display the
currently selected language.
1=English. Press and to
cycle. Press MENU to select and
save.
VOICEMAIL
When the door station is pressed, and not answered within 40 seconds,
the visitor can leave a message. Once complete, the handset will display
the symbol. Up to 16 messages can be saved.
To listen to voicemail, press MENU to play. If there are more than 1
message, press and to select the message required and press
MENU to play.
= Pause / Exit = Continue = Delete, long
press = delete all.
SET TIME ON DISPLAY
Press MENU for 2 seconds. The hour digits will begin flashing.
Press or to adjust. Press MENU to cycle from hour setting to
minutes and repeat. Press MENU a third time to exit and save changes.
Coding another handset to the System
Code
Button
Foil screening
wrapped
around MIC
wires for best
performance!
+
-
GND
MIC
connections
To add an extra handset to the system, follow the sequence below..
1) Press and HOLD the code button on the door station for 3 seconds,
until the LED’s on the bottom of the board start to flash.
2) Press and hold the Code button on the new handset ignoring the first
short tone, until you hear a confirmation tone (“Di-Do-Do”). This may take
up to 10 seconds.
3) Once the door station lights stop flashing, then you can test the
system by pressing the call button on the door station. The new handset
should ring. If not, repeat the process from the top.
(keep short for better audio)
Speech Panel Connections
Speaker
MIC -VE
MIC +VE
Call
Button
12v
0V
NC
C
NO
TMCLK
COM
EGR
Volt free
relay output
Keypad Connections
(SK model)
Ver 3
C
Note: For earlier models, the existing master handset lights will
flash after step 1. You will need to press the MENU button on the
existing handset first, before proceeding to step 2 above.
The amber LED indicates standby mode (flashing), or programming
mode (ON).
Green LED indicates output 1 active.
Red LED indicates output 2 active.
EG IN (EGRESS INPUT)
A Normally Open (N.O.) input terminal refers to (-) ground, with the help of a normally open button
to activate the Output 1 for the same time period as the user code. Egress button is usually put
inside the house near the door. More than one egress buttons can be connected in parallel to the
terminal. Leave this terminal open if it is not used.
KEY ACT.(KEYPAD ACTIVE OUTPUT)
An NPN transistor open collector output. It switches to (-) ground for 10 seconds on each key
touching. This can be used to turn on lights, CCTV camera, or buzzer to notify a guard. The rating
of this output is: Ic max: 100mA sink, Vc max: 24VDC
DU OUT (DURESS OUTPUT)
An NPN transistor open collector output. It switches to (-) ground after the Duress Code is entered.
Use it to trigger an alarm zone, or turn on a buzzer to notify a guard. Ic max: 100mA sink. Vc max:
24VDC
Additional keypad information
Keypad Programming (only SK models)
For most installations, it is sufficient to add a single keypad code for all
users. However, you can program up to 99 codes for relay 1 and 10
codes for relay 2. To do this, you need to first put the unit into multi
mode.
The unit is now in programming mode. Amber LED
will remain ON. 0000 is default programmers code.
Note: Pressing * again will exit programming mode.
0
Enter user code for relay 1.
0 0 0 *
0 ? ? ? ? #
Choosing single user mode or multi user
Enter Programming mode
8 9 0 0 # Set to SINGLE USER mode and refresh system.
8 9 0 1 # Set to MULTI USER mode and refresh system.
Programming User codes for SINGLE USER mode
1 ? ? ? ? #
2 ? ? ? ? # Enter user code for relay 2.
Enter NEW MASTER programming code.
0 ? ? ? ? #
Programming User codes for MULTI USER mode
Enter NEW MASTER programming code.
(4-8 digits for all multi codes!)
1 ? ? ? ? #??
User number 00-99 Code 4-8 digits
Enter up to 100 user codes for relay
output 1
2 ? ? ? #??
User number 0-9 Code 4-8 digits
Enter up to 10 user codes for relay
output 2
Programming Relay output modes
4 0 ? ? ? # Output 1 in momentary mode. ??? Can be 1-3
digits, 1-999 seconds
4 1 #Output 1 in latching or toggle mode.
5 0 ? ? ? #
5 1 #
Output 2 in momentary mode. ??? Can be 1-3
digits, 1-999 seconds
Output 2 in latching or toggle mode.
Restore Defaults
1) Disconnect the power supply.
2) Put the DAP jumper in the ON position.
3) Re-connect the power supply. The buzzer will be activated.
4) Put the DAP jumper back in the OFF position.
5) The keypad is now in programming mode, ready to receive data.

This manual suits for next models

1

Popular Intercom System manuals by other brands

3M C860 operating instructions

3M

3M C860 operating instructions

Elvox 12F3 Installation and operation manual

Elvox

Elvox 12F3 Installation and operation manual

Aiphone TAR-3 Installation & operation manual

Aiphone

Aiphone TAR-3 Installation & operation manual

Toa N-XC65-W user manual

Toa

Toa N-XC65-W user manual

Toa EX-16 Installation handbook

Toa

Toa EX-16 Installation handbook

Glensound BEATRICE B4 Product details

Glensound

Glensound BEATRICE B4 Product details

Vook VHD670 Operation and installation manual

Vook

Vook VHD670 Operation and installation manual

Aiphone NEM-10 Specifications

Aiphone

Aiphone NEM-10 Specifications

Perel SCAMSET6 Introduction & Features

Perel

Perel SCAMSET6 Introduction & Features

Technaxx TX-59+ user manual

Technaxx

Technaxx TX-59+ user manual

Zennio GetFace IP ZVP-WOCAM user manual

Zennio

Zennio GetFace IP ZVP-WOCAM user manual

LEGRAND EASYKIT Plus installation manual

LEGRAND

LEGRAND EASYKIT Plus installation manual

Ezviz HP7 manual

Ezviz

Ezviz HP7 manual

Grant's Automation AN1808-12S operating manual

Grant's Automation

Grant's Automation AN1808-12S operating manual

Robin Compact manual

Robin

Robin Compact manual

Clear-Com TEMPEST 2400 Reference manual

Clear-Com

Clear-Com TEMPEST 2400 Reference manual

urmet domus 2VOICE 1083/48 manual

urmet domus

urmet domus 2VOICE 1083/48 manual

Toa EXES-5000 Installation handbook

Toa

Toa EXES-5000 Installation handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.