Door-Gard 232iLM Installation manual

6-050800 X2 1
232iLM Keypad Installation & Programming
PRINTER’S INSTRUCTIONS:
INSTR/PROG,232ILM-AL/232ILM-BZ - P/N: 6-050800 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLDED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1
Specifications
Case Dimensions:
6-1/2” L x 1-3/4” W x 1-1/8” D
Electrical:
Voltage: 5-12 VDC (keypad)
12-24 VAC/DC (controller)
Current (max): 120 mA
Relay Contacts:
Main Relay (controller): 2 Amps
Aux Relays (controller): 1 Amp
Bell Relay:
Form A; 1 Amp @ 30 VDC;
500 mA @ 125 VAC
Environmental:
-20º F to 130° F
Features
●Vandal Resistant Case
●Sealed for Indoor or Outdoor Applications
●LED’s for Relay Status Indication
●Bell Output
●Surface Mount
●Illuminated Hardened Keys
●Rated for Greater than One Million Key Cycles
Applications
●Low to Medium/Heavy Traffic Areas
●Rough Service Environments
●Mullion Frame Mounting
●Dimly Lit Areas
Description:
The 232iLM Access Control unit consists of two pieces:
an SSWiLM keypad front end and a 232 Access Control
Module. The Door ♦ Gard Series SSWiLM keypad
combines elegant looks with a mullion mount design in
a rugged, vandal resistant case, which you can use for
almost any application. The SSWiLM has hardened backlit
keys designed to perform in medium to high traffic areas
and in rough duty environments. The electronics are also
conformal coated, which makes the keypad suitable for
indoor or outdoor applications.
Basic Operation:
To gain access through the door enter your code
(1-6 digits) followed by the ✱key on the keypad.
Packing List:
(1) SSWiLM Keypad
(1) 232 Access Control Module
(1) Eight-Conductor Wire Harness
(4) Three-Conductor Wire Harness
(1) Controller Hardware Pack
(1) Mullion Hardware Pack
(1) 5/64” Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) Installation/Programming Manual
(1) Self-Contained Access Control Programming Guide
Wire Harness Configuration:
Pin Wire Color Signal Name
1 Red Power (+)
2 Black Power (-)
3 White/Black Data 0
4 White/Yellow Data 1
5 Blue Not Used
6 Brown Not Used
7 White Bell Relay Contact (A)
8 White Bell Relay Contact (B)
Wiring Requirements:
18 AWG – 1000 Ft.
20 AWG – 500 Ft.
22 AWG – 250 Ft
232iLM Keypad
Installation & Programming Instructions
Note: This product is designed to be installed and serviced
by security and lock industry professionals.

2 6-050800 X2
232iLM Keypad Installation & Programming
Keypad Installation Procedure:
Step 1: Drill through the back plate using a 11/64” bit. Use the template on the back page to accurately mark the mounting
holes before drilling. Then drill the mounting holes with a 9/64” drill bit. Also drill the hole for the wires. This may
vary depending on the number of conductors required.
Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now
connect the required wires to the 8-conductor wire harness provided. The wire harness plugs into the 8-position
connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but do not tape
the drain wire to the jacket. The drain wire must be connected to ground at the controller end. See the diagrams
below.
Step 3: Finally mount the keypad onto the mounting surface using the provided screws. Do no over-tighten the screws,
which may result in damage.
Wiring the SSWiLM Keypad to a 232 Access Control Module
The connection between the SSWiLM Keypad and the 232 Controller requires a 4-conductor, stranded wire with overall
foil shield. The 8-conductor wire harness from the keypad connects to connector P6 on the controller. Connect the wires,
color to color (red to red, black to black, white/black to white/black and white/yellow to white/yellow). Refer to the wire
lengths on the first page. As mentioned above, the drain wire must be attached to Ground on the controller side, which is
the V- terminal or negative of your power supply.

6-050800 X2 3
232iLM Keypad Installation & Programming
Basic Access Control Using an Electromagnetic Lock (Maglock)
Basic Access Control Using an Electric Door Strike
A filtered and regulated
DC power supply is
recommended.
A filtered and regulated
DC power supply is
recommended.
If you aren’t using door
contacts you must short the
white/orange and white wires.
If you aren’t using door
contacts you must short the
white/orange and white wires.

4 6-050800 X2
232iLM Keypad Installation & Programming
Integrated Access Control Wiring
Wire Color Relay Connection
Gray Normally Closed
Blue Common
Green Normally Open
A filtered and regulated
DC power supply is
recommended.

6-050800 X2 5
232iLM Keypad Installation & Programming
Wiring the Bell Output to a Speaker:
The SSWiLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open
and the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure,
such as a doorbell. The relay output provides a dry contact, but you can run up to 24 VDC or 125 VAC through it for
devices that require power to operate. The diagram below shows these connections.
Keypad Mounting Height
Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on
center off the floor.

6 6-050800 X2
232iLM Keypad Installation & Programming
Programming the 232iLM Keypad
The SSWiLM keypad has it’s own local programming options. All user codes and other access control features are
programmed into the controller. Refer the Self-Contained Access Control Programming Guide for those features. The
programming options chart below shows all the programming commands available in the SSWiLM.
To program the SSWiLM you first must enter program mode.
To enter program mode enter the following on the keypad: 099 # program code ✱(default program code is 6789).
Keypad Default Settings
Option Default Setting Option Default Setting
Local Program Code 6789 Audio Keypress Feedback Enabled
Visual Keypress Feedback Enabled Door Bell Select Continuous
Keypad Illumination Enabled Keypad Dimming Enabled
Programming Options Chart
Command/Action Keys to Enter/Details
Command 90
Change Local Program Code 90 # 0 # 0 # new code ✱new code ✱(default = 6789)
Command 91
Set/Clear Keypad Options
(options below, defaults in bold)
91 # option # set/clear # ✱ ✱
Option Clear Set
0 – Visual Keypress Feedback 0 = Disabled 1 = Enabled
1 – Audio Keypress Feedback 0 = Disabled 1 = Enabled
11 – Keypad Illumination 0 = Disabled 1 = Enabled
12 – Keypad Dimming 0 = Disabled (always bright) 1 = Enabled
13 – Door Bell Select 0 = Disabled 1 = Enabled
Command 92
Set Door Bell Duration
92 # 4 # time # ✱ ✱ Set timed output (1 – 99 seconds)
92 # 4 # 0 # ✱ ✱ Set to continuous
Command 96
Reset Keypad to Default Settings 96 # 0 # 0 # ✱ ✱
Exit Program Mode Press the ✱Key
Testing the Keypad
After installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad
is working properly.
●To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 ✱
●If all 12 keypresses are accepted, the keypad enters self-test mode.
●The LEDs alternate three times followed by the sounder beeping three times.
●When finished the yellow LED starts flickering rapidly.
●Press ✱to clear.

6-050800 X2 7
232iLM Keypad Installation & Programming
LED Indications
LED State Description
Red Solid Door Locked
Green Solid Door Unlocked
Yellow Solid Programming Error
Yellow Flashing Slowly (single flash) Controller Program Mode
Yellow Flashing Slowly (double flash) Front End Program Mode
Yellow Momentary Flash Visual Keypress Feedback
Replacing the 232m (discontinued) with an 232iLM
The 232iLM is functionally equivalent to the 232m keypad, which was discontinued. It’s not, however, a direct physical
replacement. They are both two piece units, but they use a different control boards. It is not possible to replace just the
mullion keypad portion of the unit. You must replace the entire unit. Refer to the previous sections for wiring your new
232iLM unit.
Program Mode Loopback
If you’ve forgotten the local program code use the following loopback connection to enter program mode. Power down
the unit, short the wires in the configuration illustrated, then power the unit back up. The yellow LED should be flashing.
Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the
original configuration.
Limited Warranty
This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24)
months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through
Nortek Security & Control’s normal distribution channels. Nortek Security & Control does not warrant this product to
consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There
are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising
out of or in connection with use or performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied
warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Nortek
Security & Control LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact Returns at
1-855-546-3351 for an RA# and other important details.
Technical Support
DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. If the keypad still does not
work after troubleshooting, please call the Technical Services department at 1-800-421-1587.