manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DQE
  6. •
  7. Bathroom Fixture
  8. •
  9. DQE HM1001C User manual

DQE HM1001C User manual

Standard Decontamination Shower HM1001C Shower Assembly
A. Remove, inspect, and count all parts (see Parts List below).
B. Connect the Bottom U-Bases (#1) and Extenders (#2).
C. Insert shower uprights (#3, #4, and #5) into corners of base. Note: Valve Upright
(#5) should be placed on the side of nearest water supply. Aim shower heads so
that the spray pattern is vertical and inside of opposite upright.
D. Connect Top U-Bases (#6) and Extenders (#2) to form Top Assembly
E. Connect Top Assembly to Uprights.
F. Connect Hand Held Spray Hose (#7) with Nozzle (#8) to bottom outlet in Valved
Upright. Attach Hand Held Hose Hanger (#9) to Valved Upright.
G. Attach Water Supply Hose to upper inlet in Pressure Reducing Valve (#10). The
optimum shower operation is attained when at least 15 gpm (30-50 psi) of water is
supplied to the shower inlet. If water supply is greater than 90 psi pressure, use
the included pressure reducer coupling between the water supply hose and the
upper inlet.
H. Place Shower Enclosure (#11) on top of shower as shown with window on the same
side as Spray Upright (#4).
Parts List Replacement parts are available, contact DQE to order.
PART NAME QTY PART NUMBER
1. Bottom U-Base (blue tape) 2 HMPT1001C5
2. Extender 4 HMPT1001C6
3. Upright 2 HMPT1001C3
4. Spray Upright 1 HMPT1001C2
5. Valve Upright 1 HMPT1001C4
6. Top U-Base (red tape) 2 HMPT1001C1
7. Handheld Spray Hose 1 HOSEBLUE
8. Fan Spray Nozzle 1 HM214
9. Handheld Hose Hanger 1 HMPT10017
10. Water Pressure Regulator 1 HM212
11. Shower Enclosure 1 HM1055
12. Vinyl Carry Bag (body) 1 BAGSTDB
(not shown)
13. Vinyl Carry Bag (uprights) 1 BAGSTDU
(not shown)
14. Stakes (not shown) 2 HMPTSTAKE
15. Straps (not shown) 2 HMPTSTRAP
SAVE THESE INSTRUCTIONS FOR IMPORTANT OPERATING,
PARTS, MAINTENANCE, AND WARRANTY INFORMATION PART CODE
For shower warranty PAGE 1
www.dqeready.com | p. 800-355-4628 | f. 317-295-9822 | [email protected]
3
3
5
10
8
7
9
11
6
6
1
1
2
2
2
2
4
www.dqeready.com | p. 800-355-4628 | f. 317-295-9822 | [email protected]
Standard Decontamination Shower HM1001C
Shower Inspection and Maintenance
A. As with all emergency equipment, you should develop an inspection program that
assures the shower’s suitability for use in an incident.
B. Program should include deploying, visually inspecting, and operating the shower
at least every 3 months. All problems should be immediately corrected.
C. Maintenance on this shower is minimal. The inspection program should reveal any
problems with quick connects or hose connections. These may include worn or
missing O-Rings, broken cam locks or leaking joints. Contact DQE for replacement
part needs.
D. Occasional coatings of silicone based lubricant on the quick connect surfaces and
cam locks will ensure they function smoothly.
Effective Spray Pattern
A. The most effective spray pattern creates a virtual wall of water by overlapping the
fan-shaped spray and keeping the spray in a vertical plane with the upright
portion of the shower.
B. All shower heads should be aimed so that the centers of the fans are at
approximately the center point of the average user’s body as they stand in the
shower.
C. The optimum spray pattern is attained when at least 15 gpm (30-50 psi) of water
is supplied to the shower inlet.
Shower Operation
A. Turn water supply on. Upper valve should be in the open (parallel to pipe)
position and lower handheld sprayer valve should be closed. It takes
approximately 1 minute for full spray pattern to be achieved.
B. Check aim of shower heads and use shower according to your standard operating
procedures.
C. The handheld unit can be used by opening the lower valve. It can be used with or
without the shower heads running.
D. After use, the shower should be fully decontaminated using your standard
operating procedures and in full compliance with state and federal regulations.
The shower should be inspected for damage or missing parts and should be
completely dry before storage. Store in vinyl carry bag in moderate
environmental conditions out of direct sunlight or exposure to ozone.
SAVE THESE INSTRUCTIONS FOR IMPORTANT OPERATING,
PARTS, MAINTENANCE, AND WARRANTY INFORMATION PAGE 2
High Winds
A. When the Standard Decontamination Shower is being used outdoors in windy
weather, it is best to operate the shower for a short time in order to fill the lower
section with water. The weight of the water helps secure the shower to the ground.
B. When wind speeds exceed 20 mph, it may be necessary to use the enclosed straps
and stakes as a secondary means to secure the shower to the ground.
Instructions for Strap Use:
C. Set shower up so that the pathway through the shower is perpendicular to the
wind.
D. Wrap straps around top pipes on both sides and feed one end of strap through
the loop at the other end. Cinch it tight.
E. Extend strap out and secure the other end to the ground using the enclosed
stake or other method.

Other DQE Bathroom Fixture manuals

DQE Quick Response HM3000C User manual

DQE

DQE Quick Response HM3000C User manual

DQE Indestructo HM7000 User manual

DQE

DQE Indestructo HM7000 User manual

DQE Quick Response HM3000C User manual

DQE

DQE Quick Response HM3000C User manual

DQE Decono HM2000C User manual

DQE

DQE Decono HM2000C User manual

Popular Bathroom Fixture manuals by other brands

BENKISER 677 Installation and service

BENKISER

BENKISER 677 Installation and service

Franke AQUALINE WC AQRM553C Installation and operating instructions

Franke

Franke AQUALINE WC AQRM553C Installation and operating instructions

Sapho ZS123 instructions

Sapho

Sapho ZS123 instructions

Kraus FVS-13800 installation manual

Kraus

Kraus FVS-13800 installation manual

Helvex E-922 installation guide

Helvex

Helvex E-922 installation guide

Speakman S-1495-AF installation instructions

Speakman

Speakman S-1495-AF installation instructions

Hans Grohe Croma Select S 280 1jet Showerpipe 26890... Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Croma Select S 280 1jet Showerpipe 26890... Instructions for use/assembly instructions

DURAVIT Combi E operating instructions

DURAVIT

DURAVIT Combi E operating instructions

Kohler K-18751 quick start guide

Kohler

Kohler K-18751 quick start guide

Anzzi TUNDRA SP-AZ039 install guide

Anzzi

Anzzi TUNDRA SP-AZ039 install guide

Spectrum Brands Pfister Sonterra LF-WL8-SNP Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Sonterra LF-WL8-SNP Quick installation guide

Kohler K-4108 quick start guide

Kohler

Kohler K-4108 quick start guide

imex CF01 Installation

imex

imex CF01 Installation

VADO ORA ORA-MFSRKWO-RO-CP installation guide

VADO

VADO ORA ORA-MFSRKWO-RO-CP installation guide

Symmons Carrington 443RH Operation & maintenance manual

Symmons

Symmons Carrington 443RH Operation & maintenance manual

Toto NEOREST YH900 manual

Toto

Toto NEOREST YH900 manual

AM.PM BLISS L SOLO SLIDE 90 Assembly instructions

AM.PM

AM.PM BLISS L SOLO SLIDE 90 Assembly instructions

BELLOSTA ponte vecchio B3-158 Installation instruction

BELLOSTA

BELLOSTA ponte vecchio B3-158 Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.