SAVE THESE INSTRUCTIONS FOR IMPORTANT OPERATING, PARTS, AND MAINTENANCE INFORMATION
Indestructo®Decon ShowerHM7000 Assembly Instructions
A. Remove, inspect, and count all parts (see Parts List below).
B. Assemble base by connecting the two U-Bases (#1) to the Base Extenders (#2).
C. Insert Vertical Uprights (#3, #4) into Base Extenders (#2), making sure shower
heads are directed inward.
D. Lay Top Uprights (#5, #6) on flat surface and pre-assemble, then place into
Vertical Uprights (#3, #4).
E. Assemble Side Panel (#7) by inserting upper and lower vertical pieces into
horizontal pieces and then attaching the two halves together at the center. Use
the mounting clips to attach Side Panel (#7) to Shower as shown.
F. Attach upper and lower Brass Hose Shutos (#12) to both garden hose fittings on
shower Vertical Inlet Upright (#3). If water supply is greater than 90 psi pressure,
use the Water Pressure Regulator (#8) between the water supply hose and the
lower Brass Shuto Valve (#12).
G. Attach the Fan Spray Nozzle (#9) and Hose (#10) to the upper Brass Hose Shuto
(#12) and attach Handheld Hose Hanger (#11) to the upright. Fan sprayer should
be in “o” position.
H. Position spray heads as described in the “Eective Spray Pattern” section on Page 2.
Parts List Replacement parts are available, contact DQE to order.
PART NAME QTY PART NUMBER
1. U-Base 2 HMPT7000-1
2. Base Extender 2 HMPT7000-2
3. Vertical Inlet Upright 1 HMPT7000-3
4. Vertical Upright 1 HMPT7000-4
5. Top Upright (male) 1 HMPT7000-5
6. Top Upright (female) 1 HMPT7000-6
7. Side Panel Assembly 2 HMPT7000-7
(includes 2 uprights, 2 crossbars, 3 mounting clips, 1 screen, 4 fabric clamps)
8. Water Pressure Regulator 1 HM212
9. Fan Spray Nozzle 1 HM214
10. Indestructo Hose 1 CTHM7000-18
11. Handheld Hose Hanger 1 HMPT10017
12. Brass Hose Shuto 2 N115C
13. Vinyl Carry Bag (not shown) 1 CTHM7000-9
14. Stakes (not shown) 2 HMPTSTAKE
15. Straps (not shown) 2 HMPTSTRAP
www.dqeready.com | p. 800-355-4628 | f. 317-295-9822 | [email protected]
1
2
4
3
9
10
11
12
8
6
7
5
PART CODE
For shower warranty
SAVE THESE INSTRUCTIONS FOR IMPORTANT OPERATING, PARTS, AND MAINTENANCE INFORMATION PAGE 2
Indestructo®Decon Shower HM7000
A. Attach water supply hose with standard garden hose fitting (not included) to
lower Brass Hose Shuto (#12). Optimum shower operation is attained when at
least 15 gpm (30-50 psi) of water is supplied to the shower inlet.
B. Turn water supply on. Lower Brass Hose Shuto (#12) should be in the “open”
position and Fan Sprayer (#9) should be in the “closed” position. It takes
approximately 1 minute to achieve full spray pattern.
C. Check aim of shower heads and use shower according to your standard operating
procedures.
D. After use, the shower should be fully decontaminated using your standard
operating procedures and in full compliance with state and federal regulations.
E. The shower should be inspected for damage or missing parts and should be
completely dry before storage.
F. Store in vinyl carry bag (#13) in moderate environmental conditions out of
direct sunlight or exposure to ozone.
Eective Spray Pattern
A. The most eective spray pattern creates a virtual wall of water by overlapping
the fan-shaped spray and keeping the spray in a vertical plane with the upright
portion of the shower.
B. All shower heads should be aimed so that the centers of the fans are at
approximately the center point of the average user’s body as they stand in the
shower.
C. The optimum spray pattern is attained when at least 15 gpm (30-50 psi) of water
is supplied to the shower inlet.
A. As with all emergency equipment you should develop an inspection program
that assures its suitability for use in an incident.
B. Program should include deploying, visually inspecting, and operating the
shower at least every 3 months. All problems should be immediately corrected.
C. Maintenance on this shower is minimal. The inspection program should reveal
any problems with quick connects or hose connections. These may include worn
or missing O-Rings, broken cam locks or leaking joints.
D. Due to the nature of the materials used in this shower, cracked pipes are very
unlikely.
E. Occasional coatings of silicone based lubricant on the quick connect surfaces
and cam locks will ensure they function smoothly.
High Winds
A. When the Indestructo Shower is being used outdoors in windy weather, it is
best to operate the shower for a short time in order to fill the lower section with
water. The weight of the water helps secure the shower to the ground.
B. When wind speeds exceed 20 mph, it may be necessary to use the enclosed
Straps (#14) and Stakes (#15) as a secondary means to secure the shower to the
ground.
Instructions for Strap Use:
C. Set shower up so that the pathway through the shower is perpendicular to the
wind.
D. Wrap straps above 45° bend on the Top Uprights (#5, #6) on both sides and feed
one end of strap through the loop at the other end. Cinch it tight above the 45°
bend.
E. Extend strap out and secure the other end to the ground using the enclosed
stake or other method
www.dqeready.com | p. 800-355-4628 | f. 317-295-9822 | [email protected]
Shower Operation Shower Inspection and Maintenance

Other DQE Bathroom Fixture manuals

DQE HM1001C User manual

DQE

DQE HM1001C User manual

DQE Quick Response HM3000C User manual

DQE

DQE Quick Response HM3000C User manual

DQE Decono HM2000C User manual

DQE

DQE Decono HM2000C User manual

DQE Quick Response HM3000C User manual

DQE

DQE Quick Response HM3000C User manual

Popular Bathroom Fixture manuals by other brands

agape BJHON 1 ACER1083E Series Assembly instructions

agape

agape BJHON 1 ACER1083E Series Assembly instructions

Glacier bay 67094W-6A01 Installation and care guide

Glacier bay

Glacier bay 67094W-6A01 Installation and care guide

Kohler K-12183 installation guide

Kohler

Kohler K-12183 installation guide

STIEBEL ELTRON MAE-K Operation and installation manual

STIEBEL ELTRON

STIEBEL ELTRON MAE-K Operation and installation manual

Glacier bay HD67499W-6404 Installation and care guide

Glacier bay

Glacier bay HD67499W-6404 Installation and care guide

OVE MILANO 48 manual

OVE

OVE MILANO 48 manual

Hans Grohe Raindance Select S 240 2jet 27129 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Raindance Select S 240 2jet 27129 Series Instructions for use/assembly instructions

Allen + Roth Davidson-48GP-SN instruction manual

Allen + Roth

Allen + Roth Davidson-48GP-SN instruction manual

Gessi Private Wellness 63211 manual

Gessi

Gessi Private Wellness 63211 manual

RIHO LUCID GD401 installation manual

RIHO

RIHO LUCID GD401 installation manual

Luxart Poydras PO711FMTO Installation

Luxart

Luxart Poydras PO711FMTO Installation

Kohler K-4777 Installation and care guide

Kohler

Kohler K-4777 Installation and care guide

Symmons SRT-0600-70-TRM installation guide

Symmons

Symmons SRT-0600-70-TRM installation guide

Franke RODX605E manual

Franke

Franke RODX605E manual

Anzzi SP-AZ8097 install guide

Anzzi

Anzzi SP-AZ8097 install guide

agape Undici ACER0384 Assembly instructions

agape

agape Undici ACER0384 Assembly instructions

NYMAS PFGB 18 Series Installation and operating instructions

NYMAS

NYMAS PFGB 18 Series Installation and operating instructions

Kinedo Kinemagic Design DES1306AG-C installation instructions

Kinedo

Kinedo Kinemagic Design DES1306AG-C installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.