Dr.Dabber Switch User manual

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
1/18
Switch User Manual
(https://cdn.shopify.com/s/files/1/1102/6350/files/instruction-manual-switch.pdf?4940999847495111870)
Safety Information
Dr. Dabber products are intended for use by persons of legal smoking age, not by nonsmokers or by children,
women who are pregnant or breastfeeding, or persons with or at risk of heart disease, high blood pressure,
hypertension, diabetes, or taking medicine for depression or asthma. Discontinue use and consult a physician if
you experience misuses symptoms such as nausea, vomiting, dizziness, diarrhea, weakness and rapid heart-beat
or hypertension.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
2/18
Read the User Manual fully BEFORE operating your Dr. Dabber
SWITCH. Improper operation can lead to damaging the unit,
voiding the warranty, and possible harm to the user.Induction
Safety
Do not place any foreign metallic material in the glass top of the SWITCH. Induction heating systems will heat ANY
CONDUCTIVE materials placed inside the electromagnetic fields. Use ceramic or glass loading and dab tools when
the SWITCH is in operation.
A very small percentage of individuals may experience epileptic seizures or blackouts when exposed to certain
light patterns or flashing lights.These conditions may trigger previously undetected epileptic symptoms or seizures
in persons who have no history of prior seizures or epilepsy. If you, or anyone in your family has an epileptic
condition or has had seizures of any kind, consult your physician before using.
What’s in the Box
1. SWITCH Unit
2. Battery Pack
3. Glass Percolator Attachment
4. White Ceramic Induction Cup (Oil)
5. Black Ceramic Induction Cup (Leaf)
6. Ceramic Leaf Filter Cap
7. Glass Loading Tool & Carb Accessory
8. Reverse Action Tweezers
9. Silicone Storage Container
10. Charging Cable and Adapter
11. Instruction Manual

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
3/18
Warranty Information
Register your Dr. Dabber product upon receiving your unit.
Visit DrDabber.com/Register to get started!
This unit is under a 24 month Warranty on electronic components, battery pack, and charging cable and
adapter.
The SWITCH and Induction Heating
Dr. Dabber is proud to launch the SWITCH, our first induction heating unit capable of vaporizing oil or leaf materials
with precise power & carefully calibrated temperature profiles.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
4/18
The SWITCH was designed and developed from the ground up in the United States by our unique team of
engineers, scientists, designers, and vaporizer experts. The result is a truly unique product that addresses the
shortcomings most people are used to with a vaporizing device.
In technical terms, the SWITCH is a precision directed energy delivery device using electromagnetic coupling to
transmit energy in the form of an oscillating magnetic field into the induction cups. Advanced electronics are
employed to create a high frequency alternating magnetic field. The magnetic field is absorbed by the induction
cups. During this process of absorbing the induced magnetic field, heat is created.
The SWITCH can control power to an accuracy of .1%. It modulates the power to precisely control the temperature
of the induction cups throughout the heating cycle. These heating cycles are then optimized to produce the best
possible vaping experience. During the preheat phase the SWITCH induces power into the induction cups to get
them up to temperature incredibly quickly. In fact, with most temperature profiles, the unit is ready to use within 5
seconds of pressing the ‘Go’ button.
Utilizing induction heating means the SWITCH has a number of advantages. The induction cups heat significantly
faster than any other heating method currently available. They are specifically designed to create an even heating
surface temperature with less hot-spots, providing a consistent flavor during the vaporizing experience. There are
no atomizers to replace. The electronics are totally shielded from the vaporization environment meaning the unit is
leakproof. There are no electrical connections to the heating element that can wear out or break over time. All of
these induction heating benefits work together to give you a totally unique, precise and practical vaporizing
experience.
It should also be mentioned that the SWITCH has been designed to reduce or eliminate oxygen from the
vaporization environment. Without oxygen present, your material cannot combust. Plain and simple. Oxygen is
classified as an oxidizer which means it easily combines with other molecules forming new and unwanted
compounds. The lack of oxygen during the vaporization process prevents combustion and oxidation of the vapor
compounds resulting in a smoother vapor, less waste and higher efficiency.
Read more on the features, benefits, science, and product development of the SWITCH at www.drdabber.com
(http://www.drdabber.com).
Learning About Your SWITCH
Use with caution. Must be 18 years of age or older to operate.
Charge device fully before use.
The SWITCH includes a removable battery pack located underneath the base-plate. The device can be used while
the battery pack is charging.. Each battery pack can last up to 100 hits on a full charge in the leaf or oil mode.
Only use Dr. Dabber approved charging cable, adapter, or battery packs with the SWITCH. Non-Dr. Dabber
accessories may damage the unit, and will void the warranty.
Operating the SWITCH with anything other than authentic Dr. Dabber SWITCH Induction Cups may damage the
unit or cause bodily harm, and will immediately void all warranty.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
5/18
The Induction Cups will become extremely hot. Do not touch once powered on, and give the Induction Cups
enough time to cool after operation before handling. Always remove the induction cups with the reverse action
tweezers.
Do not attempt to use the device without the Glass Percolator Attachment in place.
SWITCH Anatomy

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
6/18
Powering The SWITCH On And Off
Flip the Power Switch to either the (LEAF)mode for vaporizing leaf-based products, or the (OIL) mode for
essential oils.
When changing modes on the SWITCH, the Power Switch must be turned to the ‘OFF’ position before turning
to the opposite mode.
The unit is turned off by returning the Power Switch to the center position. The LEDs will light up Cyan, then
fade to Black.
Internal persistent memory allows the SWITCH to be turned back on and retain the most recent Power Settings
within that Mode.
Adjusting SWITCH Power Settings

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
7/18
Press the (+) or (-) button to display the current Power Setting.
Press (+) or (-) button again within 5 seconds to increase or decrease the Power Setting.
To save setting immediately press the (Go) button. If button is not pressed within 5 seconds, setting will
automatically be saved.
After the Power Setting is saved, the front LEDs will illuminate Pink to display the units battery level. Each LED
represents 20% charge ( eg: 5 LEDs represents a full charge, 1 LED represents 20% battery life) Pink flashing
lights indicate the battery contains less than 10% charge. Under this condition, The SWITCH must be charged
before next use.
Using Oil Mode
Fill the Glass Percolator Attachment while removed from the unit with a few ounces of water (test the
attachment before putting it back on the unit to ensure water does not splash into the mouthpiece).
Secure the Glass Percolator Attachment onto the SWITCH glass top.
Be sure the Power Switch is on the oil setting (OIL).
Set to the desired Power Setting by using the (+) or (-) buttons. 1 YELLOW LED is calibrated for maximum
flavor profile and 5 YELLOW LEDs is calibrated for optimal vapor density.
Place the Ceramic Induction Cup into the glass top. It is also possible to pre-load the Ceramic Induction Cup
prior to placing in the glass top.
Prepare your product on the loading tool.
Press the (Go) Button.
The SWITCH LEDs will escalate Red when heating then turn Green when the unit has reached temperature.
Once the lights turn green, you may use the device.In standard mode the device will hold the heat profile for 15
seconds which is then followed by a cooldown mode indicated by cascading Blue LEDs.
Press the (Go) button at any time to cancel the heating cycle.
When the unit returns to standby mode, it is ready for the next heating cycle.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
8/18
Using Leaf Mode
Fill the Glass Percolator Attachment while removed from the unit with a few ounces of water (test the
attachment before putting it back on the unit to ensure water does not splash into the mouthpiece).
Secure the Glass Percolator Attachment onto the SWITCH glass top.
Be sure the power switch is on the leaf setting (LEAF).
Set to the desired power setting by using the (+) or (-) buttons. 1 GREEN LED is calibrated for maximum flavor
profile and5 GREEN LEDs is calibrated for optimal vapor density.
Fully pack and compress the Ceramic Induction Cup with your leaf material. The Ceramic Induction Cup can
hold approximately 0.35 grams.
Place the Ceramic Induction Cup into the glass top and cover with the Ceramic Leaf Filter. (prongs facing up)
Press the (Go) Button, and place the carb cap atop the Glass Percolator Attachment.
The SWITCH LEDs will escalate Red when heating then turn Green when the unit has reached temperature.
Once the lights turn green, you may use the device.In standard mode the device will hold the heat profile for 15
seconds which is then followed by a cooldown mode indicated by cascading Blue LEDs.
Press the (Go) button at any time to cancel the heating cycle.
When the unit returns to the standby mode it is ready for the next heating cycle.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
9/18
Auto Cool Down Cycle
The SWITCH may go in to a cooling cycle if the base unit becomes too warm to operate.
The cool down cycle is indicated by the front LEDs illuminating Blue in a cascading pattern.
Minimum cool down cycle is 5 seconds.
The automatic cool down cycle length is determined by the internal temperature of the unit. The warmer the
unit, the longer the cool down. This feature prevents the unit from ever overheating and causing damage to the
advanced electronics.
Maximum cool down cycle time is 4 minutes.
If cool down cycle is interrupted by powering the Switch Down, then cool down cycle will reset upon powering
the Switch back on.
Induction Cups
Ceramic Induction Cups should only be removed after they have cooled to a safe temperature.

4/9/22, 4:44 PM
Switch User Manual - Dr. Dabber Knowledge Base
https://drdabber.helpscoutdocs.com/article/76-switch-user-manaul
10/18
Ceramic Induction Cups should only be removed with the reverse action tweezers.
Although interchangeable, the White Ceramic Induction Cup was designed for use with essential oils, while the
Black Ceramic Induction Cup is designed for leaf.
The SWITCH is able to detect whether or not an Induction Cup is present and will not begin a heating cycle
without a Ceramic Induction Cup in place.
Trying to operate the SWITCH with anything other than authentic Dr. Dabber SWITCH Induction Cups may
damage the unit and/or cause bodily harm and will void all warranty.
*** CRYSTAL INDUCTION CUP MUST BE USED IN CRYSTAL MODE ***
Standby Lighting Options
The SWITCH has 25 different ambient light settings to choose from when the unit is in Standby Mode. Once
set, the SWITCH will retain your favorite light setting until it is changed again.
To change light settings, press and hold the (-) button.
While holding down the (-) button, cycle through the lighting options by pressing the (Go) or (+) buttons.
Release the (-) button to save the selected lighting option.
1:Stealth (Glass top lights will not illuminate)
Other manuals for Switch
1
Table of contents
Other Dr.Dabber Vaporizer manuals