DR. JOHANNES HEIDENHAIN TNC 114 Operating instructions

Service-instructions
HEIDENHAN -l-NC114
DR.JOHANNES HEIDENHAIN
Feinmechantk. Optik und Elektronik PrGsionsteilungen
Postfach 1260. D-8225 Traunreut Telefon (086691314
Telex 56831 Telegrammanschrift DIADUR Traunreut

DR.JOHANNES HEIDENHAIN
D-8225
Trsunreut
Telefon (08669) 31.O.Telex 56831
TNC
114
IMPORTANT INSTRUCTIONS
Kundendienst
Page 1 stand: 01.10.83
Subject to change (without notice)
HEIDENHAIN is constantly working on further developement of
its TNC controls. It is therefore possible that details of
a certain control may differ slightly of the control
version which is being described herein. For this reason it
may be necessary to request an updated service manual from
us.
Note
Reproduction of this service manual is not permitted without
our consent.
The TNC 114 contains sub-assemblies with CMOSelements.
Although MOS IC's are equipped with an input protection
diode network to eliminate the build-up of static
charges, care must be taken when handling these elements.
The following requirements in the work area must be met:
Prior to working with CMOScomponents or with assemblies
equipped with CMOSelements, all table coverings, all operated
instruments and/or tools, as well the work personnel, must be
properly grounded.
A portable "MOS-HANDLING-SET" for field service is necessary
when exchanging the operating software and/or servicing the
TNC 114.
1) a cable that equalizes potential differences
between conductive work surface and ground
2) a wristband that provides an electrical connection
between person and conductve work surface
3) a conductive work surface

TNC
114
DESCRIPTION
Block Diasrams
DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31.0,Telex 56831
Kundendienst page 1
stand: 01.10.83
---
L-L
r --
iTNC wiring

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O.Telex 56831
TNC 114
DESCRIPTION
Block Diagrams
Page 2 stand: 01.10.83
Kundendienst
power supply board
23.6 vw
ov
power supply
voltage Signal
supervision
3-
"N&z"

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O.Telex 56831
TNC 114
DESCRIPTION
Block Diagrams
Kundendienst page 3
stand: 01.10.83
00
900
RI
EXE 2x with
ref.-imp.
evaluation
analog board
A
,-A/D7
-
2
Y
X
signal
evaluation
RID1 and
momentary
V.SlWZ
aquisition
A r\
h------v

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 5663,
TNC 114
DESCRIPTION
Block Diagrams
Kundendienst
Page 4 stand: 01.10.83
\ analog output board
+ 15v
is+
P
___-..
L
A/DO-A/D7
'switching'switching
outputsoutputs
+ 12 v+ 12 v
PP
L
i
-D-
0 . ..+12 v
intended value output
ov

DR.JOHANNES HEIDENHAIN
D-8225
Traunreut
Telefon (08669) 31-O. Telex 56831
TNC 114
DESCRIPTION
Block Diasrams
Kundendienst page 5 -
stand: 01.10.83
6,144 MBZ
lI!EL-
.-
A8 - Al5
display board
address:bus
EPROM
IC-Pl RAN
withI/O-
Ports and
Timer
EAROM
address/data bus A/DO-A/D7
programmable interface
momentary
momentary momentary
display X display Y display 2
‘/
programmable,
~interface

DR.JOHANNES HEIDENHAIN
D-8225
Traunreut
Telefon (066691 31-O. Telex 56831
TNC 114
FAIL DIAGNOSTICS
Page 1 stand: 01.10.83
Kundendienst
1.
Automatic fail diagnostics
With operating faults, an automatic fault message is
issued by the TNC 114 which simultaneously opens the
regulator release contact.
2.
Transducer is defective
The accompanying momentary position LED will blink
with a transducer defect.
Erasing the message:
Switch-off line voltage: switch-on line voltage after
fault has been remedied.
Internal test program
The internal test program will begin after switching-on.
Visual control
- All segments of the momentary position value and
the preset display must illuminate together with the
same intensity.
Defect in the electronic
Faults of this type are coded by the TNC 114, the
lamps over the reference point keys will illuminate.
Erasing the message: if after switching-on the fault
message reappears, the TNC 114 must then be sent to
the factory for repair. (with noted lamp fault coding)
Positioning direction error The following fault conditions may occur:
.
If for a selected positioning direction the machine
coupling lever is switched in the false direction the
- All decimal points of the preset value must illuminate.
The decimal points of the momentary position value must
illuminate from the second decade.
- After approx. 3 sec. the preset values will be in the
axis display, the present value display = 0. Operating
mode El1 with
q
]is selected.
- The momentary test condition will be displqyed in a
coded manner with the LED's of the
q
,a ,
q
,
q
1
keys. The lower LED row will blink with a fault.
The following ICs are tested one after another: ROM,
RAM, TIMER.
feed will be switched-off after 200 lun of traversing. x 0 0 0 ROMerror
A U-shaped symbol will appear in the display. 0 x 0 0 RAM error
Erasing the message: press the
q
1key: restart and 0 0 x 0
bring the cobplinq lever in the x 0 x 0
correct position. 0 x x 0
x x x 0
0 0 0 x
x 0 0 x
timer 1 (Q22). counter 0 (Pin 9-X forwards)
timer 1 , counter 1 (Pin 15-Y ' )
timer 1 , counter 2 (Pin 18-Z w )
timer 2 (Q261, counter 0 (Pin 9-X backwards)
timer 2 , counter 1 (Pin 15-Y u
timer 2 , counter 2 (Pin 18-Z n
-“_

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (086691 31-O.Telex 56831
TNC
114
FASL DIAGNOSTICS
Kundendienst
Page 2 stand: 01.10.83
3. Failure localization
The following directions are only valid if the
prerequisite that all secondary power supply voltages
are present, is met!
L
power supply board
6
+ 5v Q
ov 8
"N&z d"
200
,i~
21@
1
soldering terminal
6
7
8
9
13
17
18
19
4,5
10,ll
20.21
I
voltage
+5v
ov
uLED
ovLED
+15v
-12v
-15v
-30v
23,6V-
20,5Vm
37,5v+
,,,
,,,
,,
,,
,,.
,.
,,,
,.,
,,~,
,,
,,.,.
,,,,
,,,
,.
.,

DR.JOHANNES HEIDENHAIN
D-8225
Traunreut
T&ion (08669) 31-O. Telex 56831
TNC 114
FAIL DIAGNOSTICS
Kundendienst
Page 3 stand: 01.10.83
For reasons of complexity of the interdependent control functions, the following information
regarding the possible fail source location serves as guide only.
Occurinq fault
- transducer supervision
system
addressed
- counting error
- counting direction switch-over not functioning
- no reference impulse
- key does not function
- control LED dark
- momentary position display faulty/undefined
- preset display faulty/undefined
- set function faulty
- reference values are not/faulty stored
- direction supervision does not respond'
- no standstill supervision
- no/faulty momentary value output
- no EMERGENCY OFF/traversing direction/axis relays X,Y,Z
closed loop release/speed momentary value internal,
external
- approach behaviour faulty
- coded failure display after switch-on:
!amQq
x x x
x x
x x
x x x x
x x
Possible fault location
transducer
system/analog
board
analog/display board
power supply/analoq board
transducer system/analog board
display board
display board
display board
display board
display board
display board
power supply/analoq board/analoq output board
display/analog board
manual feed potentiometer/analog output board
analog output board
analog output board
display board
display board
analog board
analog board
analog board
analog board
analoq board
analog board

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 56831
Kundendienst
4.
Test instructions
4.1 Necessary equipment
For testing purposes, the following equipment is
required: Input: Key: preset: Axis display:
- digital multimeter
- rotary encoder with photo-element signal output
(e.g. MINIROD 450)
11111.111
- 2 dummy connectors for transducer inputs 15555.555
16666.666
x. y, z
x. y. z
X8y, z
x, y, z
x, y, z
x, y, z
x, y, z
x, y. z
x, y, z
x, y, z
x, y, z
x, y, z
x. y. z
x, y, z
x. y, z
0,01/0,005 mm
Inch
0,01/0,005 mm
CE/X, Y, Z
x, y, z
x, y. z
Inch
D/2
-D/2
+D/2
Inch
11111.115 11111.115
15555.555 15555.555
16666.670 16666.670
TNC 114
FAIL DIAGNOSTICS
Test Instructions
Page 1 stand: 01.10.83
4.2 Testing the set function of an assembled control
Operating mode "HAND" and key
q
:.
19999.990
.l
1.
11.
111.
1111
11111
11111
-19876.543
-12345.678
0.0001
0.0009
10
100
19999.990
0.100
1.000
11.000
111.000
1111.000
11111.000
-11111.000
-19876.545
-12345.680
-12345.680
- 486.0504
- 486.0504
0.0000
0.0002
0.0010
0.025
5.000
95.000
100.000
3,937o
19999.990
0.100
1.000
11.000
111.000
1111.000
11111.000
-11111.000
-19876.545
-12345.680
-12345.68
- 486.0505
- 486.0504
0.0000
+ 0.0002
+ 0.0010
+ 0.025
+ 0.0010

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O.Telex 56831
Kundendienst
Storage function
1. Level 1. Level
X-axis set to 11111.115
X-axis 437.4454
X-axis
set to 12222.225
Y-axis 481.1900
Z-axis set to 13333.335 Z-axis 524.9344
2.
Level
X-axis set to 14444.445
Y-axis set to 15555.555
Z-axis set to 15555.665
2.
Level
X-axis
568.6788
Y-axis 612.4234
Z-axis 656.1678
3.
Level
X-axis set to
17777.775
Y-axis set to 18888.885
Z-axis set to 19999.995
3.
Level
X-axis 699.9124
Y-axis
743.6568
Z-axis 787.4014
4.
Level
X-axis set to 10000.000
Y-axis set to 12345.675
z-axis set to 19876.545
TNC 114
FAIL DIAGNOSTICS
Test Instructions
page
2
stand: 01.10.83
Switch-off line voltage 4.3 Testing the dessembled control
then switch-on again. After
switch-on select the INCH Supervision function
operating mode. The following
values must be displayed: Disconnect transducer connections for X, Y and Z axes:
The momentary value display must blink in the same
order of disconnection.
Counting function
Connect rotary encoder to X-axis input dummy connectors
on X and Z axis. Test the counting function in~positive
and negative directions of all axis and decades.
On the backside of the unit, the counting direction for
every axis can be selected using the DIL switch 1, 2 and 3.
The counting direction is positive when switch is closed.
4.
Level counting direction positive
X-axis 393.7008
Y-axis
486.0502
Z-axis 782.5410
Control function
- Position a positive and negative value in absolute
dimensioning (e.g. + 100, - 100)
- Position several values in incremental dimensioning
in both positive and negative directions, in all axis.
- Traverse a larger value (lOOO), test feed potentiometer
during the positioning as well as the STOP key and
traverse functioning. Repeat the test for Y- and Z-axis.

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 56831
TNC
114
FAIL DIAGNOSTICS
Test Instructions
Kundendienst
Page 3 stand: 01.10.83
Reference pulse evaluation
Select operating mode "HAND". Set axis to reference. Press
the
FtEF
key, REF diode must laminate. Rotate rotary encoder
Shaft over reference impulse, (REF LEDs off) press REF key,
press again and hold.
Rotate rotary encoder shaft until reference impulse stops
the display.
The displayed value must evaluate to:
impulse count x signal subdivision x evaluation x counting
istep
example: MINIROD 450
100 impulse/rotation
TNC 114:
signal subdivision 2 x
evalution 4x
counting step 5w
100 x 2 x 4 x 5 um = 4.000 (displayed value)
Axis supervision
The axis supervision is active on all 3 axes within a
distance of 205 wn. The standstill of the remaining axes that
are momentary not controlled is supervised. The direction of
the momentary controlled axis is supervised.
Direction supervision test
Connect rotary encoder to transducer system input X-axis and
dummy connections on transducer input X- and Z-axis. Select
operating mode "absolute dimensioning". For example:
enter + 1000 and initiate traversing with the X-key.
Rotate rotary encoder counter clock-wise (minus direction).
With a value ) - 205 w the segments b, f, and q must luminate
on the preset display for all decades. (uuuuu~uu )
Repeat the test with negative positioning values and positive
rotation directions.
Repeat test for Y- and Z-axis.
Standstill supervision test
Connect rotary encoder on transducer syste&n X-axis input and
dummy connectors on transducer Y- and Z-axis inputs.
Start X-axis postioninq.
Connect rotary encoder to transducer system Y-axis input and
rotate shaft.
The error message (uuuuuuuu ) appears in
the preset display for a displayed momentary value of 3205 w.
Repeat the test in positive and negative directions for all
axes.
1
.,.-
___._l..-,..--,“-
,,
.,.,,
,,,,,
_

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 56831
TNC 114
EXCHANGE
Control Exchange
Kundendienst
Page 1 stand: 01.10.83
1. General 2. Interface wiring
Caution!
DO not disconnect connector.s under voltage
All inputs/outputs must only be connected to circuits having
voltages produced according to VDE 0100/5.73 §8. (low
protection voltage)
Control inputs: - input resistance approx: 100 kOhm
- voltage input to determine feed
rate
- regulated voltage of 0 to + 12 V
is required.
Momentary position output: - loading with respect to 0 V:
R ?. 2.4 k , C 2 50 nF
- analog voltage: 0 to + 12 v.
Control switching outputs: - contact loading:
48 V / 0.3 A
max.
switching power 10 W
- working contacts: axis release X
- working contact: regulator
release
- switch-over contact: traversing
direction
- switch-over contact:
momentary
traversing speed internal/
external.
CONTROL USER
multipoint terminal

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 56831
Kundendienst
TNC 114
EXCHANGE
Control Exchange
Page 2 stand: 01.10.83
3.
Exchange
1. Note operating program-nr. and ident-nr. of the control!
2.
Disconnect mains coupling of the control.
3. Isolate connections on the multipoint terminal.
Order (l-22) and note wire colors.
4. Disconnect transducer systems for X, Y, 2.
Assembly in reverse order.
Important: Observe correct positioning of the line voltage
selector!
Fusing: T 0.4 A

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O.Telex 56831
TNC 114
EXCHANGE
Board Exchange
Page 1 stand: 01.10.83
1. General
Observe MOSprotection procedures.
2.
Exchange
1) Remov& the 4 Phillips mounting screws oil the control
backside.
2) Service block including:
- front plate
- display board
- analog board
remove from frontside.
3) Disconnect DIL-switch connector located on the analog
board.
4) Disconnect grounding connector, located on the analog
output board.
5) Disconnect transducer system connector for X, Y, Z,
located on the analog board.
6) Disconnect
flat cable connector for control input/
outputs, located on the analog output board.
7) Disconnect
the supply voltage to the analog board.
8) Remove the 5 Phillips mounting screws of the analog
output board.
9) Disconnect flat cable connector located on the analog
output board.
10) Remove analog output board.
11)
Disconnect
the analog board supply voltage.
12) Remove the 5 mounting bolts of the analog board.
13) Disconnect flat cable.
14) Remove analog board.
15) Remove the 5 mounting bolts of the display board.
16) Disconnect the 4 keyboard connectors.
17) Remove display board.
Assembly in reverse order.
Observe the correct location of the LEDs when assemblying.
The power supply is offered complete inclusive line
transformer and inclosure backwall as replacement part.

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O. Telex 56831
TNC 114
EXCHANGE
Software Exchanqe
Kundendienst
Page 1 stand: 01.10.83
1. General
The operating program for the TNC 114 is contained in an
EPROM (IC-Pl, Q28) on the display board:
program ident number
xxx xxx xx
pr.g~.-k&t stand
IC program ident number
xxx xxx xx
-merit standIC program nr.
2. Program
program description: standard program
program ident number: 212 927 02
IC program ident number:
212
927 1B
issue : 04.09.1981
display board
\
,_
,,.,-.
._~--,-.,~._
,.--
“__
.
,‘,
,...
,.,

- np. JOHANNES HEIDENHAIN
!25
Traunreut
fon (08669) 31.0,Telen 56831
Kundendienst
TNC 114
EXCHANGE
Software Exchange
Page 2 stand: 01.10.83
3. Characteristic curve description
The ramp characteristic curve can be adjusted by the DIL
switches S1/2 and S1/3 on the analog output board.
(4 different ramp lengths are possible)
DIL switch up : switch closed
DIL switch down: switch open
DIL switch 2 and 3 up : curve 1
DIL switch
3
up : curve 2
DIL switch 2 up : curve 3
all DIL switches down : curve 4
Ramp characteristic curve TNC 114
’
,,,,,,,1
‘1
i
.I
analog output board

DR.JOHANNES HEIDENHAIN
D-8225 Traunreut
Telefon (08669) 31-O.Telex 56831
TNC 114
EXCHANGE
software Exchange
Kundendienst
Page 3 stand: 01.10.83
4.
Program exchange
Important: observe
MOS
protection procedures.
In order to exchange the operating program, the display
board must be demounted from the control.
Necessary tools: - IC extract/insertion tool
- small screwdriver
- remove EPROMfrom display board using extraction tool
- place EPRQMonto MOS protection mat
- insert new EPROMcorrectly using insertion tool
Important: - The inserted IC
must
be pointing in the same
direction as the remaining IC's on the display
board.: b
- Before installing the board into the control,
visually check if all the IC pins are contacting
the IC socket.
After an operating program exchange the program nr. has to be
changed on the backside of the control.
,