DR PRO-7500F User manual

PRO-7500F Portable Generator
Owner’s Manual
MODEL:________________________
SERIAL:________________________
DATE PURCHASED:______________
SAVE THIS MANUAL FOR FUTURE REFERENCE
002141
(000209b)
WARNING
Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury.
Register your DR Power Equipment
product at:
www.drpower.com
1-855-447-3734

Table of Contents
Section 1 Introduction and Safety 1
Introduction ..................................... 1
Safety Rules .................................... 1
Safety Symbols and Meanings ........ 1
Exhaust and Location Hazards ....... 2
Electrical Hazards ........................... 3
Fire Hazards .................................... 3
Standards Index .............................. 4
Section 2 General Information and
Setup .............................................. 5
Know Your Generator ..................... 6
Emissions ........................................ 6
Fuel Selection Dial .......................... 7
Multimeter ....................................... 7
Connection Plugs ............................ 7
Remove Contents from Carton ....... 8
Assembly ......................................... 8
Battery Cable Connection ............... 9
Add Engine Oil ................................ 9
Fuel ............................................... 10
Section 3 Operation .................... 12
Operation and Use Questions ....... 12
Before Starting Engine .................. 12
Prepare Generator for Use ............ 12
Grounding the Generator When In Use
12
Know Generator Limits ..................13
Transporting/Tipping of the Unit ....13
Changing Fuels .............................14
Starting Pull Start Engines .............14
Starting Electric Start Engines .......15
Low Oil Level Shutdown System ...15
.......................................................15
Section 4 Maintenance and
Troubleshooting ..........................16
Maintenance ..................................16
Maintenance Schedule ..................16
Preventive Maintenance ...............16
Engine Maintenance ......................16
Battery Replacement .....................18
Inspect Muffler and Spark Arrester 18
Valve Clearance ............................19
Storage ..........................................19
Troubleshooting .............................20
(000393)
WARNING
Operating, servicing and maintaining this
equipment can expose you to chemicals
including engine exhaust, carbon monoxide,
phthalates, and lead, which are known to the
State of California to cause cancer and birth
defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust,
do not idle the engine except as necessary,
service your equipment in a well-ventilated
area and wear gloves or wash your hands
frequently when servicing your equipment.
For more information go to
www.P65Warnings.ca.gov.

Owner’s Manual for Portable Generator 1
Section 1 Introduction and Safety
Introduction
Thank you for purchasing a DR Power Equip-
ment product. This unit has been designed to
provide high-performance, efficient operation,
and years of use when maintained properly.
If any section of the manual is not understood,
contact Customer Service at 1-855-447-3734,
or www.drpower.com with any questions or
concerns.
The owner is responsible for proper mainte-
nance and safe use of the equipment. Before
operating, servicing or storing this generator:
• Study all warnings in this manual and on
the product carefully.
• Become familiar with this manual and the
unit before use.
• Refer to the Assembly section of the man-
ual for instructions on final assembly proce-
dures. Follow the instructions completely.
Save these instructions for future reference.
ALWAYS supply this manual to any individual
that will use this machine.
The information in this manual is accurate
based on products produced at the time of
publication. The manufacturer reserves the
right to make technical updates, corrections,
and product revisions at any time without
notice.
Safety Rules
The manufacturer cannot anticipate every
possible circumstance that might involve a
hazard. The alerts in this manual, and on tags
and decals affixed to the unit, are not all inclu-
sive. If using a procedure, work method, or
operating technique that the manufacturer
does not specifically recommend, verify that it
is safe for others and does not render the
equipment unsafe.
Throughout this publication, and on tags and
decals affixed to the unit, DANGER, WARN-
ING, CAUTION, and NOTE blocks are used to
alert personnel to special instructions about a
particular operation that may be hazardous if
performed incorrectly or carelessly. Observe
them carefully. Alert definitions are as follows:
NOTE: Notes contain additional information
important to a procedure and will be found
within the regular text of this manual.
These safety alerts cannot eliminate the haz-
ards that they indicate. Common sense and
strict compliance with the special instructions
while performing the action or service are
essential to preventing accidents.
Safety Symbols and Meanings
• If you start to feel sick, dizzy, or weak after
the generator has been running, move to
fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poison-
ing.
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
(000001)
DANGER
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
(000002)
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
(000003)
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
000657
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.

2 Owner’s Manual for Portable Generator
• Follow procedures in the Maintenance and
Troubleshooting section. For safety rea-
sons, if you feel uncomfortable performing
any task, call 1-855-447-3734 for assis-
tance.
Exhaust and Location Hazards
• If you start to feel sick, dizzy, or weak after
the generator has been running, move to
fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poison-
ing.
• NEVER run a generator indoors or in a
partly enclosed area such as garages.
(000179b)
DANGER
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
(000104)
DANGER
Electrocution. Water contact with a power source,
if not avoided, will result in death or serious injury.
(000116)
DANGER
Electrocution. Turn utility and emergency
power supplies to OFF before connecting power
source and load lines. Failure to do so will result
in death or serious injury.
(000146)
WARNING
Equipment and property damage. Do not alter
construction of, installation, or block ventilation for
generator. Failure to do so could result in unsafe
operation or damage to the generator.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING
(000250)
WARNING
Equipment and property damage. Do not operate unit on
uneven surfaces, or areas of excessive moisture, dirt, dust
or corrosive vapors. Doing so could result in death, serious
injury, property and equipment damage.
(000111)
WARNING
Moving Parts. Keep clothing, hair, and appendages
away from moving parts. Failure to do so could
result in death or serious injury.
(000108)
WARNING
Hot Surfaces. When operting machine, do not
touch hot surfaces. Keep machine away from
combustables during use. Hot surfaces
could result in severe burns or fire.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
WARNING
Risk of injury. Do not operate or service this machine
if not fully alert. Fatigue can impair the ability to service
this equipment and could result in death or serious
injury. (000215)
WARNING
Injury and equipment damage. Do not use generator
as a step. Doing so could result in falling, damaged
parts, unsafe equipment operation, and could result
in death or serious injury. (000216)
CAUTION
(000291)
Equipment damage. Do not attempt to start or operate
a unit in need of repair or scheduled maintenance.
Doing so could result in serious injury, death, or
equipment failure or damage.
WARNING
000406
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.
(000179b)
DANGER
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
(000146)
WARNING
Equipment and property damage. Do not alter
construction of, installation, or block ventilation for
generator. Failure to do so could result in unsafe
operation or damage to the generator.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING

Owner’s Manual for Portable Generator 3
• ONLY use outdoors and far away from win-
dows, doors, vents, crawl spaces and in an
area where adequate ventilation is avail-
able and will not accumulate deadly
exhaust gas.
• Using a fan or opening a door will not pro-
vide sufficient ventilation.
• Point muffler exhaust away from people
and occupied buildings.
Electrical Hazards
• The National Electric Code (NEC) requires
the frame and external electrically conduc-
tive parts of the generator be properly con-
nected to an approved earth ground. Local
electrical codes may also require proper
grounding of the generator. Consult with a
local electrician for grounding requirements
in the area.
• Use a ground fault circuit interrupter in any
damp or highly conductive area (such as
metal decking or steel work).
Fire Hazards
• Allow at least 5 feet of clearance on all
sides of the generator when operating to
prevent overheating and fire.
• Do not operate the generator if connected
electrical devices overheat, if electrical out-
put is lost, if engine or generator sparks, or
if flames or smoke are observed while unit
is running.
• Keep a fire extinguisher near the generator
at all times.
(000144)
DANGER
Electrocution. Contact with bare wires,
terminals, and connections while generator
is running will result in death or serious injury.
(000104)
DANGER
Electrocution. Water contact with a power source,
if not avoided, will result in death or serious injury.
(000145)
DANGER
Electrocution. In the event of electrical accident,
immediately shut power OFF. Use non-conductive
implements to free victim from live conductor. Apply
first aid and get medical help. Failure to do so will
result in death or serious injury.
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
(000166b)
DANGER
Explosion and Fire. Do not overfill fuel tank. Fill to
1/2 inch from top of tank to allow for fuel expansion.
Overfilling may cause fuel to spill onto engine causing
fire or explosion, which will result in death or
serious injury.
(000199)
DANGER
Explosion and Fire. LP vapors are extremely flammable
and explosive. Do not use or store LP cylinder in a
building, garage, or enclosed area except as authorized
by NFPA 58 or B149.2 (Canada). Failure to do so will
result in death or serious injury.
(000200)
WARNING
Explosion and fire. The cylinder valve should be
left off (closed) when generator is not in use.
Failure to do so could result in death or serious
injury.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
WARNING
Fire risk. Fuel and vapors are extremely
flammable. Do not operate indoors. Doing so
could result in death, serious injury, or
property or equipment damage. (000281)
WARNING
Explosion and fire risk. Do not smoke near unit.
Keep fire and spark away. Failure to do so could
result in death, serious injury, or property or
equipment damage.
(000282)
WARNING
Explosion and Fire. Do not smoke while
refueling unit. Failure to do so could result in
death, serious injury, or property or equipment
damage. (000284a)

4 Owner’s Manual for Portable Generator
Standards Index
1. National Fire Protection Association
(NFPA) 70: The NATIONAL ELECTRIC
CODE (NEC) available from www.nfpa.org
2. National Fire Protection Association
(NFPA) 5000: BUILDING CONSTRUC-
TION AND SAFETY CODE available from
www.nfpa.org
3. International Building Code available from
www.iccsafe.org
4. Agricultural Wiring Handbook available
from www.rerc.org, Rural Electricity
Resource Council P.O. Box 309 Wilming-
ton, OH 45177-0309
5. ASAE EP-364.2 Installation and Mainte-
nance of Farm Standby Electric Power
available from www.asabe.org, American
Society of Agricultural & Biological Engi-
neers 2950 Niles Road, St. Joseph, MI
49085
6. CSA C22.2 100-14 Electric motors and
generators for installation and use, in
accordance with the Rules of the Cana-
dian Electrical Code
7. ANSI/PGMA G300 Safety and Perfor-
mance of Portable Generators. Portable
Generator Manufacturer’s Association,
www.pgmaonline.com
This list is not all inclusive. Check with the
Authority Having Jurisdiction (AHJ) for any
local codes or standards which may be appli-
cable to your jurisdiction.

Owner’s Manual for Portable Generator 5
Section 2 General Information and Setup
Figure 2-1. Features and Controls
Generator Components
Figure 2-2. PRO-7500F Control Panel
002142
002144
002141
10 2
13
5
9
6
12
11
1
9
15
8
4
7
3
14
1 Fuel Selection Dial
2 Gasoline Fuel Tank
3 LPG Hose Connector
4OilDrain
5 Oil Fill Cap
6 Air Filter
7Battery
8 Muffler
9 Handle
10 Gasoline Fuel Cap
11 Recoil Starter
12 Fuel Shut Off (gasoline)
13 Roll Over Valve
14 Evaporative Recovery Hose
15 Spark Arrestor
16 Battery On/Off Switch
17 Engine Start/On/Off Switch
18 Choke Knob
19 120 Volt AC, 20 Amp, GFCI Duplex
Receptacle (NEMA 5-20R)
20 120/240 Volt AC, 30 Amp Locking
Receptacle (NEMA L14-30R)
21 120 Volt AC, 30 Amp Locking Receptacle
(NEMA L5-30R)
22 Circuit Breakers (AC)
23 Multimeter
24 Ground Lug
002146
18 19 21 20
23
22
16
17
24
221

6 Owner’s Manual for Portable Generator
Know Your Generator
Replacement owner’s manuals are available
at www.drpower.com.
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
that this engine/equipment complies with
exhaust and evaporative emissions stan-
dards. Locate the emissions compliance decal
on the engine to determine applicable stan-
dards. For emissions warranty information,
please reference the included emissions war-
ranty. It is important to follow the maintenance
specifications in the manual to ensure that the
engine complies with the applicable emissions
standards for the duration of the product’s life.
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
Product Specifications
Generator Specifications
Rated Power (Gasoline / Propane) 7500W / 6750W
Surge Power (Gasoline / Propane) 9375W / 8500W
Rated AC Voltage 120/240
Rated AC Load
Current @ 240V
Current @ 120V
31.3 Amps**
62.5 Amps**
Rated Frequency 60 Hz @ 3600 RPM
Phase Single Phase
Gasoline Run Time at 50% Load 10 Hours
LPG Run Time at 50% Load, 30lb Tank 8 Hours
Weight (dry) 189.1 lb / 85.7 kg
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement 420 cc
Spark Plug Part No. NGK BPR7ES or equivalent
Spark Plug Gap 0.028-0.031 inch or
(0.70-0.80 mm)
Gasoline Capacity 26.5 L (7.0 U.S. gallons)
Oil Type See Chart in Add Engine Oil
Oil Capacity 1.1 L (1.1 qt.)
* Go to www.drpower.com or call 1-855-447-3734 for replacement parts.

Owner’s Manual for Portable Generator 7
Fuel Selection Dial
The Fuel Selection Dial allows operation using
either gasoline (A) or LPG (B). Place the dial
in the 12 o'clock position (C) for long-term
storage. See Figure 2-3.
Figure 2-3. Dial Positions
Multimeter
The Multimeter tracks hours of operation for
scheduled maintenance. See Figure 2-4.
The Multimeter also displays Voltage Output,
Voltage Frequency, and Session Operation
Time. To change the display information,
press the MODE button.
Figure 2-4. Multimeter
Connection Plugs
120 VAC, 20 Amp, GFCI Duplex
Receptacle
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See Fig-
ure 2-5. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
NOTE: Limit length of extension cords to fif-
teen feet, or less, to prevent voltage drop and
overheating of wires.
Figure 2-5. 120 VAC, 20 Amp, GFCI Duplex
Receptacle NEMA 5-20R
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
AC at 30 Amps (or greater). See Figure 2-6.
Use this receptacle to operate 120 Volt AC, 60
Hz, single phase loads requiring up to 3600
watts (3.6 kW) of power at 30 Amps or 240
Volt AC, 60 Hz, single phase loads requiring
up to 7200 watts (7.2 kW) of power at 30
Amps. The outlet is protected by one 30 Amp
2-pole circuit breaker.
Figure 2-6. 120/240 VAC, 30 Amp Receptacle
NEMA L14-30R
110/120 VAC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 3-
wire cord set to the plug and to desired load.
The cord set should be rated for 125 Volts AC
at 30 Amps (or greater). See Figure 2-7.
Use this receptacle to operate 120 Volt AC,
60Hz, single phase loads requiring up to 3600
watts (3.6kW) of power at 30 Amps. The outlet
is protected by a 30 Amp push-to-reset circuit
breaker.
002609
A B C
002225
000203
000204

8 Owner’s Manual for Portable Generator
Figure 2-7. 120 VAC, 30 Amp Receptacle
NEMA L5-30
Remove Contents from Carton
1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
Accessories
3. Call Customer Service at 1-855-447-3734
with the unit model and serial number for
any missing carton contents.
4. Record model, serial number, and date of
purchase on front cover of this manual.
Assembly
Call Customer Service at 1-855-447-3734 for
any assembly issues or concerns. Please
have model and serial number available.
The following tools are required to install the
accessory kit.
• 10mm socket
• 13mm box wrench
• 5mm Hex Key
NOTE: The wheels are not intended for over-
the-road use.
See Figure 2-8.
Install wheels as follows:
1. Slide axle pin (3) through the wheel (1), 1/
2 in. flat washer (5), wheel bracket on
frame, and 1/2 in. flat washer (5).
2. Insert cotter pin (9) through axle pin (3).
Bend tabs (of cotter pins) outward to lock
into place.
Install frame foot and rubber bumpers as fol-
lows:
1. Slide M8 x 50 bolts (6) through rubber foot
(4) and holes in frame rail.
2. Install locking flange nuts (8).
Install handle(s) as follows:
1. Slide M8 x 80 bolt (7) through handle
bracket and handle (2). Install hex nut (8).
NOTE: Repeat handle assembly for model
PRO-7500F.
.
Figure 2-8. Wheel & Handle Assembly
Item Qty.
Main Unit 1
Owner’s Manual 1
Liter SAE Oil 1
Oil Funnel 1
Regulator Connecting Hose 1
Wheel (1) 2
Handle and Handle Bracket (2) 2
Hardware Bag Qty.
Axle Pin (3) 2
Rubber Feet (4) 2
1/2 in. Flat Washer (5) 2
M8 x 50 Bolt (6) 2
M8 x 80 Bolt (7) 2
M8 Nyloc Nut (8) 4
Cotter Pin (9) 2
Tool Kit Qty.
5mm Hex Key 1
10 x 13mm Wrench 1
Spark Plug Wrench with Rod 1
000844
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
002232
5
3
2
87
6
4
8
9
1

Owner’s Manual for Portable Generator 9
Battery Cable Connection
The unit has been shipped with the battery
cables disconnected.
The following tools are required to connect the
battery cables.
• 10mm box wrenches (2)
See Figure 2-9.
1. Cut off cable ties securing battery cables
and remove red cover from battery termi-
nal.
2. First, connect the red cable to the positive
(+) battery terminal with the bolt and nut
supplied.
3. Make sure connections are secure and
slide rubber boot over the positive (+) bat-
tery terminal and connection hardware.
4. Connect the black cable to the negative (-)
battery terminal with the bolt and nut sup-
plied.
5. Make sure all connections are secure and
slide rubber boot over the negative (-) bat-
tery terminal and connection hardware.
Figure 2-9. Connect Battery Cables
NOTE: If the battery is unable to start the
engine, charge with 12V battery charger.
Add Engine Oil
1. Place generator on a level surface.
2. Verify oil fill area is clean.
3. Remove oil fill cap and wipe dipstick clean.
See Figure 2-10.
Figure 2-10. Remove Dipstick
4. Add recommended engine oil as shown in
the following chart.
NOTE: Use petroleum based oil (supplied) for
engine break-in before using synthetic oil.
.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
5. Thread dipstick into oil filler neck. Oil level
is checked with dipstick fully installed.
6. Remove dipstick and verify oil level is
within safe operating range. See Figure 2-
11.
Figure 2-11. Safe Operating Range
7. Install oil fill cap/dipstick and hand-tighten.
002719
(000135)
CAUTION
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
000115
SAE 30
10W-30
Synthetic 5W-30
000399
000116

10 Owner’s Manual for Portable Generator
Fuel
Gasoline
Fuel requirements are as follows:
• Clean, fresh, unleaded gasoline.
• Minimum rating of 87 octane/87 AKI (91
RON).
• Up to 10% ethanol (gasohol) is acceptable
(where available; non-ethanol-premium fuel
is recommended).
• DO NOT use E85.
• DO NOT use a gas oil mix.
• DO NOT modify engine to run on alternate
fuels. Stabilize fuel prior to storage.
1. Verify unit is OFF and cooled for a mini-
mum of two minutes prior to fueling.
2. Place unit on level ground in a well venti-
lated area.
3. Clean area around fuel cap and remove
cap slowly.
4. Slowly add recommended fuel (A). Do not
overfill (B). See Figure 2-12.
5. Install fuel cap.
Figure 2-12. Add Recommended Fuel
NOTE: Allow spilled fuel to evaporate before
starting unit.
IMPORTANT NOTE: It is important to pre-
vent gum deposits from forming in fuel
system parts such as the carburetor, fuel
hose or tank during storage. Alcohol-
blended fuels (called gasohol, ethanol or
methanol) can attract moisture, which
leads to separation and formation of acids
during storage. Acidic gas can damage the
fuel system of an engine while in storage.
To avoid engine problems, the fuel system
should be emptied before storage of 30
days or longer. See the Storage section.
Never use engine or carburetor cleaner
products in the fuel tank as permanent
damage may occur.
Liquid Petroleum Gas (LPG)
NOTE: LPG regulator inlet pressure is approx-
imately 30 psi at 0 °F, and 218 psi at 100 °F.
• Use only standard 20 or 30 pound capacity
LPG tanks with Type 1, right hand Acme
threads with this generator. Verify re-qualifi-
cation date on tank has not expired. Do not
use rusted or damaged cylinders.
• All new cylinders must be purged of air and
moisture prior to filling. Used cylinders that
have not been plugged or kept closed must
also be purged.
• The purging process should be done by the
propane gas supplier. (Cylinders from an
exchange supplier should have been
purged and properly filled by supplier).
Connect LPG Tank
1. Remove safety plugs or caps from cylinder
valve, generator mounted regulator, and
regulator connecting hose ends.
2. With LPG tank closed, attach LPG regula-
tor connecting hose into valve. Turn plastic
coupling from the hose right (clockwise) to
tighten hose assembly onto LPG tank.
See Figure 2-13.
Figure 2-13. Connect Hose Assembly to LPG
Tank
3. Connect opposite regulator connecting
hose end to generator at mounted LPG
primary regulator with a 3/4 in. (19mm)
wrench (not supplied). See Figure 2-14.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are
extremely flammable and explosive. Add fuel
in a well ventilated area. Keep fire and spark
away. Failure to do so will result in death
or serious injury.
(000166b)
DANGER
Explosion and Fire. Do not overfill fuel tank. Fill to
1/2 inch from top of tank to allow for fuel expansion.
Overfilling may cause fuel to spill onto engine causing
fire or explosion, which will result in death or
serious injury.
000400
A
B
(000199)
DANGER
Explosion and Fire. LP vapors are extremely ammable
and explosive. Do not use or store LP cylinder in a
building, garage, or enclosed area except as authorized
by NFPA 58 or B149.2 (Canada). Failure to do so will
result in death or serious injury.
(000200)
WARNING
Explosion and re. The cylinder valve should be
left o (closed) when generator is not in use.
Failure to do so could result in death or serious
injury.
002605

Owner’s Manual for Portable Generator 11
Figure 2-14. Connect Hose to Regulator
4. Turn LPG tank valve ON and check for
leaks by spraying soapy water to check
connections. If bubbles appear, become
larger in size, or increase in number, a
leak exists. See Figure 2-15.
NOTE: Always position cylinder so the con-
nection between the valve and regulator won’t
cause sharp bends or kinks in hose.
Figure 2-15. Turn LPG Tank Valve On
NOTE: This must be corrected before using
generator. Contact Customer Service at 1-
855-447-3734 for assistance.
NOTE: When transporting and storing, keep
cylinder secured in an upright position with
cylinder valve turned off and the outlet
plugged. Keep cylinders away from heat and
ventilated when in a vehicle.
002607
002606
(000201)
WARNING
Risk of burns. Contact with liquid contents of cylinder
will cause freeze burns to the skin. If liquid contents
contacts skin or eyes, seek immediate medical attention.
(000128a)
Personal injury. Keep out of reach of children.
Failure to do so could result in death or serious injury.
WARNING

12 Owner’s Manual for Portable Generator
Section 3 Operation
Operation and Use Questions
Call Customer Service at 1-855-447-3734 with
questions or concerns about equipment oper-
ation and maintenance.
Before Starting Engine
1. Verify engine oil level is correct.
2. Verify Fuel Selection Dial is turned to
desired fuel.
3. Verify fuel level is correct.
4. Verify unit is secure on level ground, with
proper clearance and is in a well ventilated
area.
Prepare Generator for Use
Grounding the Generator When
In Use
The generator is equipped with a terminal for
the connection of a grounding electrode sys-
tem. NEC Article 250.34 (A) does not require
the frame of the generator to be connected to
a grounding electrode system when the gen-
erator only supplies power to cord and plug
connected equipment through the receptacles
on the generator.
When the generator supplies power to a 3-
pole manual transfer switch or distribution
panel boards for temporary power, a ground-
ing electrode system shall be installed and
connected to the grounding electrode terminal
on the generator. See NEC 250.30, 250.34
and 250.52 for clarification. See Figure 3-1.
• Neutral Bonded to Frame.
Figure 3-1.Grounding the Generator
Special Requirements
Review all Federal and State Occupational
Safety and Health Administration (OSHA) reg-
ulations, local codes, and ordinances applica-
ble to the intended use of the generator.
Additional regulations may apply if the genera-
tor is used at a construction site.
Consult a qualified electrician, electrical
inspector, or the local agency having jurisdic-
tion for additional requirements that may be
unique to your area, such as whether the gen-
erator is required to be registered with local
utility.
Connecting the Generator to a
Building Electrical System
It is recommended to use a manual transfer
switch when connecting directly to a building
electrical system. Connecting a portable gen-
erator to a building electrical system must be
made in strict compliance with all national and
local electrical codes and laws, and be com-
pleted by a qualified electrician.
Asphyxiation. Running engines produce
carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result in death or serious injury.
(000103)
DANGER
(000179b)
DANGER
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
WARNING
(000118a)
Risk of fire. Do not use generator without
spark arrestor installed. Failure to do so
could result in death or serious injury.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING
(000110)
WARNING
Risk of Fire. Hot surfaces could ignite
combustibles, resulting in fire. Fire could
result in death or serious injury.
(000108)
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
002147

Owner’s Manual for Portable Generator 13
Know Generator Limits
Overloading a generator can result in damage
to the generator and connected electrical
devices. Observe the following to prevent
overload:
• Add up the total wattage of all electrical
devices to be connected at one time. This
total should NOT be greater than the gener-
ator's wattage capacity.
• The rated wattage of lights can be taken
from light bulbs. The rated wattage of tools,
appliances, and motors can be found on a
data label or decal affixed to the device.
• If the appliance, tool, or motor does not
give wattage, multiply volts times ampere
rating to determine watts (volts x amps =
watts).
• Some electric motors, such as induction
types, require about three times more watts
of power for starting than for running. This
surge of power lasts only a few seconds
when starting such motors. Make sure to
allow for high starting wattage when select-
ing electrical devices to connect to the gen-
erator:
1. Figure the watts needed to start the largest
motor.
2. Add to that figure the running watts of all
other connected loads.
The Wattage Reference Guide is provided to
assist in determining how many items the gen-
erator can operate at one time.
NOTE: All figures are approximate. See data
label on appliance for wattage requirements.
Wattage Reference Guide
Transporting/Tipping of the Unit
Do not operate, store or transport the unit at
an angle greater than 15 degrees.
Device Running
Watts
*Air Conditioner (12,000 Btu) 1700
*Air Conditioner (24,000 Btu) 3800
*Air Conditioner (40,000 Btu) 6000
Battery Charger (20 Amp) 500
Belt Sander (3") 1000
Chain Saw 1200
Circular Saw (6-1/2") 800 to 1000
*Clothes Dryer (Electric) 5750
*Clothes Dryer (Gas) 700
*Clothes Washer 1150
Coffee Maker 1750
*Compressor (1 HP) 2000
*Compressor (3/4 HP) 1800
*Compressor (1/2 HP) 1400
Curling Iron 700
*Dehumidifier 650
Disc Sander (9") 1200
Edge Trimmer 500
Electric Blanket 400
Electric Nail Gun 1200
Electric Range (per element) 1500
Electric Skillet 1250
*Freezer 700
*Furnace Fan (3/5 HP) 875
*Garage Door Opener 500 to 750
Hair Dryer 1200
Hand Drill 250 to 1100
Hedge Trimmer 450
Impact Wrench 500
Iron 1200
*Jet Pump 800
Lawn Mower 1200
Light Bulb 100
Microwave Oven 700 to 1000
*Milk Cooler 1100
Oil Burner on Furnace 300
Oil Fired Space Heater (140,000
Btu)
400
Oil Fired Space Heater (85,000 Btu) 225
Oil Fired Space Heater (30,000 Btu) 150
*Paint Sprayer, Airless (1/3 HP) 600
Paint Sprayer, Airless (hand-held) 150
Radio 50 to 200
*Refrigerator 700
Slow Cooker 200
*Submersible Pump (1-1/2 HP) 2800
*Submersible Pump (1 HP) 2000
*Submersible Pump (1/2 HP) 1500
*Sump Pump 800 to 1050
*Table Saw (10") 1750 to 2000
Television 200 to 500
Toaster 1000 to 1650
Weed Trimmer 500
* Allow 3 times the listed watts for starting these
devices.

14 Owner’s Manual for Portable Generator
Changing Fuels
1. Make sure generator is turned OFF.
2. Unplug all electrical loads from the unit's
receptacles.
3. Place generator on a level surface.
4. If switching from LPG to gasoline, make
sure the LPG Tank valve is turned OFF
and disconnect LPG fuel tank from gener-
ator.
If switching from Gasoline to LPG, follow the
LPG connecting procedure in section Liquid
Petroleum Gas (LPG).
5. Turn the Fuel Selection Dial to the desired
fuel.
6. Check fuel supply of the selected fuel.
7. Follow the Starting Pull Start Engines or
Starting Electric Start Engines procedure
to start the generator.
Starting Pull Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Open the fuel shut-off valve (A). See Fig-
ure 3-2.
.
Figure 3-2.Fuel Shut-off Valve
4. Turn engine Start/On/Off switch (B) on the
control panel to On (manual start only).
See Figure 3-3.
5. Move engine choke knob (C) on control
panel outward to Full Choke position. See
Figure 3-3.
Figure 3-3.Choke Position
6. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
7. When engine starts, move choke knob to
1/2-choke position until engine runs
smoothly, then fully into Off position. If
engine falters, move choke back to 1/2-
choke position until engine runs smoothly,
then to Off position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
tected against overload with push-to-reset-
type circuit breakers. If amperage rating of
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read Know Generator
Limits carefully.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
(000199)
DANGER
Explosion and Fire. LP vapors are extremely ammable
and explosive. Do not use or store LP cylinder in a
building, garage, or enclosed area except as authorized
by NFPA 58 or B149.2 (Canada). Failure to do so will
result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
(000183)
WARNING
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
002148
A
C
B
0005911

Owner’s Manual for Portable Generator 15
Starting Electric Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Select Gasoline or LPG using Fuel Selec-
tion Dial and make sure there is an ade-
quate supply.
4. For gasoline, open fuel shut-off valve. See
Figure 3-2.
5. For LPG, make sure the LPG tank is con-
nected properly and the tank valve is
open. See Liquid Petroleum Gas (LPG).
6. Move engine choke knob on control panel
outward to Full Choke. See Figure 3-3.
7. Turn battery power switch On.
8. Press and hold Start/On/Off switch in the
Start position. When engine starts, release
the switch to the On position.
9. When engine starts, move choke knob to
1/2 choke position until engine runs
smoothly, then fully to Off position. If
engine falters, move choke knob back to
1/2 choke position until engine runs
smoothly, then move to Off position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read Know Generator
Limits carefully.
Generator Shut Down
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Move Start/On/Off switch to Off.
4. Close fuel valve.
NOTE: Under normal conditions, close fuel
valve and allow generator to run carburetor
bowl out of fuel. For emergencies, switch to
Stop.
Low Oil Level Shutdown System
The engine is equipped with a low oil level
sensor to shut down the engine automatically
when the oil level drops below a specified
level. The engine will not run until the oil has
been filled to the proper level.
IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.

16 Owner’s Manual for Portable Generator
Section 4 Maintenance and Troubleshooting
Maintenance
Regular maintenance will improve perfor-
mance and extend engine/equipment life.
Contact Customer Service at 1-855-447-3734,
or www.drpower.com to find a dealer for main-
tenance work to be performed. Regular main-
tenance, replacement or repair of the
emissions control devices and systems may
be performed by any repair shop or person of
the owner’s choosing. However, to obtain
emissions control warranty service free of
charge, the work must be performed by a DR
Power service dealer. See the emissions war-
ranty.
NOTE: Call Customer Service at 1-855-447-
3734 with questions about component
replacement.
Maintenance Schedule
Follow maintenance schedule intervals,
whichever occurs first according to use.
NOTE: Adverse conditions will require more
frequent service.
NOTE: Call Customer Service at 1-855-447-
3734 with questions about component
replacement.
NOTE: All required service and adjustments
should be each season as detailed in the fol-
lowing chart.
Preventive Maintenance
Dirt or debris can cause improper operation
and equipment damage. Clean generator
daily or before each use. Keep area around
and behind muffler free from combustible
debris. Inspect all cooling air openings on
generator.
• Use a damp cloth to wipe exterior surfaces
clean.
• Use a soft bristle brush to loosen caked on
dirt, oil, etc.
• Use a vacuum to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi)
may be used to blow away dirt. Inspect
cooling air slots and openings on generator.
These openings must be kept clean and
unobstructed.
NOTE: DO NOT use a garden hose to clean
generator. Water can enter engine fuel system
and cause problems. If water enters generator
through cooling air slots, some water will be
retained in voids and crevices of rotor and sta-
tor winding insulation. Water and dirt buildup
on generator internal windings will decrease
insulation resistance of windings.
Engine Maintenance
Engine Oil Recommendations
To maintain the product warranty, the engine
oil should be serviced in accordance with the
recommendations of this manual. For your
convenience, maintenance kits designed and
intended for use on this product are available
from the manufacturer that include engine oil,
oil filter, air filter, spark plug(s), a shop towel
and funnel. These kits can be obtained by
contacting Customer Service at 1-855-447-
3734, or www.drpower.com.
At Each Use
Check Engine Oil Level
Every 100 Hours or Every Season*
Change Oil ǂ
Clean Spark Arrestor
Every Season
Replace Spark Plug
Replace Fuel Filter
Check Valve Clearance***
Every 200 Hours or Every Season
Inspect/Clean Air Cleaner Filter**
ǂChange oil after first 30 hours of operation,
then every season.
* Change oil and oil filter every month when
operating under heavy load or in high tem-
peratures.
** Clean more often under dirty or dusty oper-
ating conditions. Replace air filter parts if
they cannot be adequately cleaned.
*** Check valve clearance and adjust if neces-
sary after first 50 hours of operation and
every 300 hours thereafter.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
(000141)
WARNING
Accidental start-up. Disconnect spark plug wires when
working on unit. Failure to do so could result in death
or serious injury.

Owner’s Manual for Portable Generator 17
.
Inspect Engine Oil Level
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill.
3. Remove oil fill cap and wipe dipstick clean.
See Figure 4-1.
.
Figure 4-1. Engine Oil Fill
4. Screw dipstick into filler neck. Remove
dipstick and verify oil level is within safe
operating range. See Figure 4-2.
Figure 4-2. Safe Operating Range
5. Add recommended engine oil as neces-
sary.
6. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
Change Engine Oil
When using generator under extreme, dirty,
dusty conditions, or in extremely hot weather,
change oil more frequently.
NOTE: Don’t pollute. Conserve resources.
Return used oil to collection centers.
Change oil while engine is still warm from run-
ning, as follows:
1. Place generator on a level surface.
2. Disconnect the spark plug wire from the
spark plug and place the wire where it
cannot contact spark plug.
3. Clean area around oil fill, and oil drain
plug.
4. Remove oil fill cap.
5. Remove oil drain plug and drain oil com-
pletely into a suitable container.
6. Install oil drain plug and tighten securely.
7. Slowly pour oil into oil fill opening until oil
level is between L and H marks on dip-
stick. DO NOT overfill.
8. Install oil fill cap, and finger tighten.
9. Wipe up any spilled oil.
10. Properly dispose of oil in accordance with
all applicable regulations.
Air Filter
Engine will not run properly and may be dam-
aged if run with a dirty air filter. Service air fil-
ter more frequently in dirty or dusty conditions.
To service air filter:
1. See Figure 4-3. Turn knob (A) and remove
air filter cover.
2. Wash in soapy water. Squeeze filter dry in
clean cloth (DO NOT TWIST).
3. Clean air filter cover before re-installing it.
NOTE: To order a new air filter, contact Cus-
tomer Service at 1-855-447-3734.
Figure 4-3. Air Filter Assembly
SAE 30
10W-30
Synthetic 5W-30
000399
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
000115
000116
(000141)
WARNING
Accidental start-up. Disconnect spark plug wires when
working on unit. Failure to do so could result in death
or serious injury.
000379
A

18 Owner’s Manual for Portable Generator
Service Spark Plug
To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Inspect electrode gap with wire feeler
gauge and reset spark plug gap to 0.028 -
0.031 in (0.7 - 0.8 mm). See Figure 4-4.
Figure 4-4. Spark Plug
NOTE: Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Battery Replacement
NOTE: The battery shipped with the generator
has been fully charged. A battery may lose
some charge when not in use for prolonged
periods of time. If battery is unable to crank
engine, use a 12V battery charger to charge
the battery.
See Figure 4-5.
1. Disconnect negative (-) battery terminal
FIRST (black wire).
2. Disconnect positive (+) battery terminal
SECOND (red wire).
Figure 4-5. Battery Connection
3. Install new battery (A). Install hold down
bracket (B), insert threaded rod (C) and
tighten with M6 nuts (D). See Figure 4-6.
Figure 4-6. Battery Connection
4. Connect positive (+) battery terminal (red
wire) FIRST. Slide rubber boot over con-
nection hardware.
5. Connect negative (-) battery terminal
(black wire) SECOND.
6. Slide rubber boot over connection hard-
ware.
• Always recycle batteries in accordance
with local laws and regulations. Contact
your local solid waste collection site or
recycling facility to obtain information on
local recycling processes. For more infor-
mation on battery recycling, visit the Battery
Council International website at: http://bat-
terycouncil.org/.
Inspect Muffler and Spark
Arrester
NOTE: It is a violation of California Public
Resource Code, Section 4442, to use or oper-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrester, as defined in Section 4442, main-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for exhaust system installed on this
engine.
NOTE: Use ONLY original equipment replace-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
000211
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
002719
002720
A
B
C
D
WARNING
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.
(000228)
Table of contents
Languages:
Other DR Portable Generator manuals
Popular Portable Generator manuals by other brands

Volvo
Volvo TAD941GE Users guide and maintenance manual

EcoFlow
EcoFlow River 600 user manual

Feider Machines
Feider Machines 20210876326 instruction manual

HERKULES
HERKULES SE 5500 SF operating instructions

Briggs & Stratton
Briggs & Stratton Generac owner's manual

Generac Power Systems
Generac Power Systems 1338-1 owner's manual