DTS INSIGHT Micom Pack FH808M07 User manual

Micom Pack
Instruction Manual
Micom Pack for Control Module
for
Flash Microcomputer Programmer
(NET IMPRESS)
FH808M07
Target Microcomputer: H8S/2612F (HD64F2612)
DTS INSIGHT CORPORATION

HF808M07 (H8S/2612F)
Revision History
Edition Date of issue Description
First Edition November 13, 2003 Initial publication
(1) No part of this manual may be reproduced, transmitted or transcribed in any form or by
any means, without the express written permission of DTS INSIGHT CORPORATION.
(2)
Information in this document may be changed without notice for purposes of
improvement and does not represent a commitment on the part of DTS INSIGHT
CORPORATION.
(3) Please contact us if you would find unclear points, questions or errors regarding the
information of this document.
(4) DTS INSIGHT CORPORATION assumes no responsibility for any damages
arising from the use or inability to use this document, or results of using the control
module.
© 2003 DTS INSIGHT CORPORATION. All Rights Reserved.
Printed in Japan
i

Contents
1OVERVIEW ........................................................................................................1
2SPECIFICATIONS................................................................................................2
2.1 TARGET MICROCOMPUTER AND SPECIFICATIONS .......................................................... 2
3COPYING WRITE CONTROL PROGRAM INTO MICROCOMPUTER ..............................3
3.1 OVERVIEW ................................................................................................................... 3
3.2 COPYING THE WRITE CONTROL PROGRAM FILE ............................................................ 4
4CONNECTING TO THE TARGET SYSTEM AND CONNECTOR .....................................5
4.1 SIGNAL LIST................................................................................................................. 5
4.2 MODEL CONNECTION TO A TARGET SYSTEM ................................................................. 6
4.3 WAVEFORM OF CONTROL SIGNAL ................................................................................. 8
5DOWNLOADING MICOM PACK ...........................................................................10
5.1 CONNECTING THE REMOTE CONTROLLER (AZ490) ..................................................... 10
5.2 DOWNLOADING MICOM PACK...................................................................................... 11
6NOTES AND CAUTIONS FOR USING CONTROL MODULE.......................................12
ii

1 Overview
The FH808M07 is the Micom Pack for the control module FH808 supporting the flash
microcomputer programmer NET IMPRESS, and contains a parameter file supporting the
microcomputer Renesas H8S/2612F.
For a Micom Pack for other microcomputers, contact us or your local distributor.
The control module supported by this Micom Pack is FH808.
CAUTION:
The Micom Pack FH808M07 is built for the specific control module FH808. Do not use this
Micom Pack with any control modules other than the specified control module.
The handling instructions are described in the Micom Pack Instruction Manual and be sure
to read this Instruction Manual carefully before you start operation.
To use the Micom Pack, you also need the remote controller AZ490 that is available for an
additional order.
For how to download the Micom Pack to the control module, see Chapter 5 “
” of this Instruction Manual.
Downloading
Micom Pack
Check once again if combination of the Micom Pack and control module is correct. Also,
check if you have a correct microcomputer, memory size, power supply, etc. Incorrect
parameter values would lead to serious damage to your microcomputer and target system.
For any questions or unclear points, please contact us.
1

2 Specifications
2.1 Target Microcomputer and Specifications
For any items that are not specifically described here, the standard specifications of the
NET IMPRESS are applied.
Target Microcomputer FH808M07
Microcomputer H8S/2134F
H8S/2612F
User Flash Memory Capacity 128Kbyte
User Flash Memory Address #000000 to #01FFFF
Programming Voltage (Vpp) Not applied.
Default
Vccp (Minimum voltage during
programming)
Object File Format
Intel HEX
Motorola S
Binary
Default Motorola S
Target Interface
UART (Asynchronous communication) Interface
2400/4800/9600/19200/31250/38400/62500/76800/10400bps
□MSBfirst ■LSB first
CSI (Synchronous communication) Interface
62.5Kbps/125Kbps/250Kbps/500Kbps/850Kbps/1.25Mbps
□MSBfirst ■LSB first
Data Transfer Format between
Flash Microcomputer Programmer
and Target System
Binary
Memory status when erased #FF
MCU Clock during programming 2MHz to 20MHz 4MHz to 20MHz
2

3 Copying Write Control Program into Microcomputer
3.1 Overview
With the control module FH808, the write control program (WCP) is sent to the target
microcomputer to run on it before execution of the Device Functions. The microcomputer
executes the programming sequence under this write control program.
Copy the write control program into the DOS area of the control module and save it under a
file name with extension “.BTP” in advance.
Only one file with extension “.BTP” can be placed in the DOS area of the control module.
You cannot place multiple files with extension “BTP” or use the control module without
placing a file with extension “.BTP”.
Write Control Program that
is booted.
DOS Area
Object Program File
WCP File
xxx.BTP
abc.S
Control Module
Target System
NET IMPRESS
3

3.2 Copying the Write Control Program File
From the Utility Assy provided with the control module, select an appropriate write control
program that has conditions matching with the target microcomputer.
To save the file with “.BTP” extension in the DOS area of the control module, follow the
steps below.
(1) Set this control module in a personal computer that has a PCMCIA card slot. Make sure
that the PC card driver has been properly installed in advance. For how to install the
PC card driver, see our Web site at the following URL:
https://www.dts-insight.co.jp/en/index.html
See the Q & A page on the flash microcomputer programmer.
(2) Copy the write control program (xxx. BTP) from the Utility Assy into the DOS area of the
FH808 control module.
4

4 Connecting to the Target System and Connector
4.1 Signal List
The table below lists signal example at the side of the target probe connector when using
the control module FH808.
CPU Signal NET IMPRESS Standard Signal CPU Signal
Vss GND 15 1 GND GND
TVpp1 16 2 TVccd User Vcc
TVpp2 17 3 Vcc
WDT 18 4 TRES
FEW TAUX3
TVpp1c 19 5 /TRES /RES
TAUX4
TVpp2c 20 6 TCK SCK2
Reserved 21 7 Reserved
Reserved 22 8 Reserved
Reserved TAUX 23 9
TAUX2
(TRW)
TBUSY 24 10 /TICS
TI0 25 11
TAUX5
(/TOE)
TVccs 26 12 TMODE MD2
TxD2 TRxD 27 13 TTxD RxD2
Vss GND 28 14 GND Vss
Table 4-1: Target Probe Signal List (FH808M07)
•
•
•
Be sure to connect the signals marked with “ “ to the target system.
The signals in dotted parentheses are also controlled for output. Connect them only when
necessary.
Though the signals listed as “reserved” are not to be used, they are being controlled. Therefore,
be sure not to connect them to a circuit of the target system.
5

4.2 Model Connection to a Target System
(6)
TCK SCK2
(12)
TMODE MD2
(18)
WDT
/TRES
(5) /RES
TTxD RxD2
(13)
(2)
TVccd
TxD2
(27)
TRxD
FWETAUX3 (19)
Vcc
GND (1, 14, 15, 28)
Vss
(10)
/TICS
H8S/2612F
User Target System
AZ410
(Probe)
NET IMPRESS
User Power Supply
The recommended value of pull-up and pull-down resistance is 10KΩ.
6

(1) For the signals defined as shared terminals, multiplexing circuit of these signals must be
provided to the user system.
/TICS signal is asserted only when the NET IMPRESS is performing the Device Functions.
/TICS signal multiplexes the signals connected to these shared terminals.
Multiplexing circuits are not required for a target system where these signals for write
control are defined as the control signals for the flash microcomputer.
Inserting the multiplexing circuit into the user system can produce the same conditions with
a state where the NET IMPRESS is not connected (i.e., the connector is unplugged) while
/TICS signal is being negated (when the Device Functions are not executed).
(2) WDT Signal:
The clock signal defined with the WDT Clock Period [FUNC D 5] is generated from WDT
signal terminal by the NET IMPRESS.
Connect this signal to the user circuit that requires the appropriate clock signal when
programming the flash memory.
(3) TRES Signal:
The NET IMPRESS is provided with /TRES signal in the standard probe, which is an open
collector type output so that it can make wired-or connection in the target system and be
connected to /RESET signal of your microcomputer using the user circuit. /TRES signal
can be used when the target system requires a reset signal of positive logic. TRES signal is
a totem pole output signal.
7

4.3 Waveform of Control Signal
Programming Mode
/TRES
TCK
TTXD
TRXD
TMODE
TRLW2
TRMS2
TRLW1
TPR1
TRRS
TRMH
TRMS1
TRMS2
TAUX3
/TICS
WDT
MCU Specification NET IMPRESS Specification
TRLW1 300ms (Minimum)
TRLW2 100ms (Minimum)
TPR1 200ms (Minimum)
TRMS1 30ms (Minimum)
TRMS2 50ms (Minimum)
TRMH 5ms (Minimum)
TRRS 100ms (Minimum)
*1: The dotted line “ “ indicates HIZ state.
8

(1) Power on the NET IMPRESS first and the target system next.
(2) /TICS signal is asserted by execution of the program command, and communication
channel for programming is connected to the NET IMPRESS on the target system.
(Multiplexing with this /TICS signal is not required for a system where communication
channel and related signals for programming are exclusively used by the NET
IMPRESS, independently from other user circuit.)
(3) The NET IMPRESS asserts a reset signal to pull the target microcomputer into the
programming mode.
(4) TVpp is raised to the specified voltage.
(5) The programming mode that is started by negating a reset signal starts communicating
with the NET IMPRESS using a specified communication circuit.
Channels specified in the MPU Clock Frequency [FUNC D F] in advance will be
selected for communication circuit.
(6) When programming is finished, applying Vpp automatically ends.
(7) The NET IMPRESS also negates /TICS signal. While /TRES signal is asserted, WDT
signal continues to generate periodic pulse signal (the clock to input to a watchdog
timer of the target system).
9

5 Downloading Micom Pack
5.1 Connecting the Remote Controller (AZ490)
The remote controller AZ490 runs on a Windows PC.
Connect a PC and the NET IMPRESS using an Ethernet cable (10BASE-T) or RS-232C
cable.
Install the control module, which supports the target microcomputer, in the NET IMPRESS.
And, download the Micom Pack to the control module installed in the NET IMPRESS.
Ethernet/RS-232C
NET IMPRESS
PC
Control Module
10

5.2 Downloading Micom Pack
You can download the Micom Pack by using the remote controller AZ490, which is available
for an additional order. Download the Micom Pack to the control module using the
Parameter Load from HD function on the File Transfer tab.
When you choose the Parameter Load from HD function, the window to select a parameter
table appears, enabling you to choose an appropriate Micom Pack.
11

12
6 Notes and Cautions for Using Control Module
(1) The control module FH808 is built for the flash microcomputer programmer NET
IMPRESS. DO NOT use this control module for any flash microcomputer
programmers other than the NET IMPESS series.
(2) The control module FH808 is built tailored to the specific microcomputer. Do not use
this control module for programming microcomputers other than the specified
microcomputer. Using this control module for microcomputers other than the specified
microcomputer would damage your target system.
(3) The NET IMPRESS consumes power of several mA from Tvcc terminal to drive the
interface IC with the target system (IC inside the NET IMPRESS).
(4) Be sure NOT to initialize (format) the control module (Compact Flash Card). The control
module contains the definition program (the control program), besides the DOS area
where you can save your files. Initializing the control module results in destroying this
control program.
(5) DO NOT insert or remove the control module while the Device Functions or the
Function key operations are being executed. Be sure not to insert or remove the control
module from the flash microcomputer programmer while accessing it.
(6) Use the flash microcomputer programmer with the control module inserted into it.
Table of contents
Other DTS INSIGHT Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo VTSA Series Description

SMC Networks
SMC Networks SYA5000 Series instruction manual

Graco
Graco 256556 Instructions-parts list

Digital Equipment
Digital Equipment DECrepeater 90FS Installation and configuration

ELT
ELT eSMART iLC PRO 25/200 1050-XR Series user guide

Joy-it
Joy-it Bread Power quick guide