Dubaco DS-210 Series User manual

DS-210
Handheld Short Range CCD Scanner
User’s Manual

System Information----------------------------------------------------------------3
Interface Selection-------------------------------------------------------------------3
Keepboard Terminal-----------------------------------------------------------------3
Language------------------------------------------------------------------------------4
Keyboard Wedge Function-----------------------------------------------------4
Keyboard Speed---------------------------------------------------------------------5
Message Terminator----------------------------------------------------------------6
RS-232 Parameters----------------------------------------------------------------7
Baud Rate-----------------------------------------------------------------------------7
RS-232 Function Installation---------------------------------------------------8
Handshaking Protocol--------------------------------------------------------------9
Scan Mode---------------------------------------------------------------------------10
Buzzer set-up-----------------------------------------------------------------------11
Frequency-----------------------------------------------------------------------------11
Adjust Buzzer Tone-----------------------------------------------------------------11
Power On Tone----------------------------------------------------------------------11
Good Read Beep-------------------------------------------------------------------11
Character Installation------------------------------------------------------------12
Other Installation------------------------------------------------------------------15
Scanning Verify----------------------------------------------------------------------15
Bar / Space Seting------------------------------------------------------------------15
Laser Data Speed Up--------------------------------------------------------------15
BAR-CODE-INSTALLATION----------------------------------------------------16
UPC-A---------------------------------------------------------------------------------16
UPC-E---------------------------------------------------------------------------------18
EAN-13--------------------------------------------------------------------------------20
EAN-8----------------------------------------------------------------------------------22
Code 39-------------------------------------------------------------------------------24
Contents
Codabar------------------------------------------------------------------------------26
Code 93------------------------------------------------------------------------------28
Code 128----------------------------------------------------------------------------30
Interleaved 2of 5-------------------------------------------------------------------33
Industrial 2 of 5---------------------------------------------------------------------35
Matrix 2 of 5-------------------------------------------------------------------------37
China Post Code-------------------------------------------------------------------39
MSI / Plessey-----------------------------------------------------------------------41
Code 32------------------------------------------------------------------------------43
Code 11------------------------------------------------------------------------------44
APPENDIX A -- ASCII------------------------------------------------------------46
ASCII Table-------------------------------------------------------------------------47
APPENDIX B – Function Key Table----------------------------------------48
Function Key Code--------------------------------------------------------------49
1
2

Enter
System Information
Set All default
SW Version
Interface Selection
*Keyboard
RS-232
USB
Keyboard Terminal Type
End
*PC/AT/,PS/2
IBM PS/2 30-80
PS/2 25,30
IBM XT
IBM 5550
NEC 9801
End
Language
*USA
Spanish
Germany
Italian
French
Japan
Keyboard Wedge function
Function Key Emulation
*OFF
KB Emulation(For NB)
*OFF
ALT Mode
*OFF
Enter
ON
ON
ON
3 4

Enter
Inter-character Delay (Default:00)
Caps Lock
ON
*OFF
Num Lock
ON
*OFF
Appendix A (00H-64H)
Inter-message Delay (Default:00)
Appendix A (00H-0AH)
Delay time=set up data*100(ms)
Keyboard Speed (Default:00 )
Appendix A (00H-08H)
End
Enter
End
Message Terminator
*CR
ESC
Tab
CR + LF
None
5 6

Enter Enter
End
End
RS-232 Parameters
BAUD Rate
1200
2400
4800
*9600
19200
38400
Data Bits
7
*8
Stop Bits
*1
2
Parity
*None
Even
Space
Odd
Mark
RS-232 Function Installation
Inter-character Delay (Default:00)
Appendix A (00H-64H)
Inter-message Delay (Default:00)
Appendix A (00H-0AH)
Delay time=set up da-ta*1(ms)
Handshaking Protocol Delay (Default:00)
Appendix A (00H-0AH)
Delay time=set up da-ta*100(ms)
7
8

Enter Enter
End
End
Handshaking Protocol
*None
ACK/NAK
RTS/CTS
Xon/Xoff
Scan Mode
Tigger On/Off
Continuous/Tigger Off
Continuous/LED always On
Flash On
*Tigger On/Good read off
Testing
Continuous/Timeout Off
Continuous/No Tigger
9 10

Enter Enter
End
End
Buzzer set-up
Frequency (Default:0AH)
Appendix A (00-10H)
Adjust Buzzer Tone (Default:05H)
Appendix A (00-10H)
Power On Tone
ON
OFF
Good read Beep
*ON
OFF
The
preamble
and
postamble
character:
You
can
put
10
ASCII
at
most
in
front
of
the
barcode
data.
When
the
installation
is
“0”
that
means
you
don’t
need
to
add
the
first
and
last character.
Please
find
the
format
as
below
The
process
for
adding
the
first
and
last
character
to
the
bar- code:
1.
Scan
the
barcode
of
“Start
Configuration”
and
“The
Preamble
Character
Installation”.
2.
Check
the
ASCII
table
to
get
the
ASCII
code
of
the
first and
last
character.
3.
Scan
the
barcode
of
ASCII
in
the
Appendix.
4.
Scan
the
“End
Configuration”.
The Preamble Installation (Default:00)
Appendix A
The Postamble Installation (Default:00)
Appendix A
Character Installation
You can pitch the buzzer tone and adjust the buzzer time
Besides, you can the voice of boot and decoding
11 12

Enter Enter
End
End
1.
Scan
the
barcode
of
the
“Start
Configuration”
and
“G1
Insert
Character”.
2.
Check
the
ASCII
table
to
get
the
ASCII
code
of
the
first and
last
character.
3.
Scan
the
barcode
of
ASCII
in
the
Appendix.
4.
Scan
the
“End
Configuration”.
5.
Repeat
the
same
process
to
the
G2
insertion.
6.
Scan
the
“End
Configuration”.
G1
Character
Insertion
(
Default
:
00
)
Appendix A
G
2
Character
Insertion
(
Default
:
00
)
Appendix A
1.
Scan
the
barcode
of
the
“Start
Configuration”
and
“G1
character
insertion
position”
2.
Check
the
ASCII
table
to
get
the
corresponding
ASCII
code
of
the
insertion
position.
3.
Scan
the
“End
Configuration”.
4.
Repeat
the
same
process
to
the
G2
character
insertion
position.
5.
Scan
the
“End
Configuration”.
G1
Character
Insertion
Position
(
Default
:
00
)
Appendix A
G
2
Character
Insertion
Position
(
Default
:
00
)
Appendix A
Code
ID
Transmission
ON
*OFF
13 14

Enter Enter
End
End
Other
Installation
Scanning Verify
*Single
Double
Bar / Space Setting
*Bar = High
*Bar = Low
Laser
Data
Speed
Up
*On
Off
UPC-A
Reading
*On
Off
Code ID (Default:F)
20H-7EH
UPC-A convert to EAN-13
On
*Off
Transmit Check Character
*On
Off
Truncate Leading Zero
On
*Off
BAR-CODE INSTALLATION
15 16

Enter Enter
End
End
Truncate Leading Digit (Default:00)
00H-0DH
Truncate Last Digit (Default:00)
00H-0DH
Select Insertion (Default:00)
00H-02H
Add-On 2/5
2 digit
5 digit
2 or 5 digit
*None
UPC-E
Reading
*On
Off
Code ID (Default:G)
20H-7EH
UPC-E convert to UPC-A
On
*Off
Transmit Check Character
*On
Off
Truncate Leading Zero
*On
Off
17 18

Enter
End
End
Enter
Truncate Leading Digit (Default:00)
00H-08H
Truncate Last Digit (Default:00)
00H-08H
Select Insertion (Default:00)
00H-02H
Add-On 2/5
2 digit
5 digit
2 or 5 digit
*None
EAN-13
Reading
*On
Off
Code ID (Default:H)
20H-7EH
Transmit Check Character
*On
Off
Truncate Leading Digit (Default:00)
00H-0DH
Truncate Last Digit (Default:00)
00H-0DH
Select Insertion (Default:00)
00H-02H
19 20

Enter Enter
End
End
Add-On 2/5
2 digit
5 digit
2 or 5 digit
*None
ISBN/ISSN Convert
On
*Off
EAN-8
Reading
*On
Off
Code ID (Default:I)
20H-7EH
Transmit Check Character
*On
Off
Truncate Leading Digit (Default:00)
00H-08H
Truncate Last Digit (Default:00)
00H-08H
Select Insertion (Default:00)
00H-02H
21 22

End
End
Enter Enter
Add-On 2/5
2 digit
5 digit
2 or 5 digit
*None
Code-39
Reading
*On
Off
Code ID (Default:J)
20H-7EH
Verification
On
*Off
Transmit Check Character
*On
Off
Checksum
On
*Off
23 24

Enter Enter
End
End
Min. Length (Default:00)
00H-32H
Max. Length (Default:32H)
00H-32H
Format
Standard Code39
Full-featured Code39
Transfer Start / End Character
On
*Off
Truncate Leading Digit (Default:00)
00H-32H
Truncate Last Digit (Default:00)
00H-32H
Select Insertion (Default:00)
00H-02H
Codabar
Reading
*On
Off
Code ID (Default:K)
20H-7EH
Verification
*On
Off
Transmit Check Character
On
*Off
Checksum
On
*Off
25 26

Enter
End
End
Enter
Truncate Leading Digit (Default:00)
00H-7EH
Truncate Last Digit (Default:00)
00H-7EH
Select Insertion (Default:00)
00H-02H
Start / End Character Type
*ABCD/ABCD
abcd/to*e
abcd/abcd
Transmit Start / End Character
On
*Off
Min. Length (Default:00)
00H-3CH
Max. Length
00H-3CH
Code93
Reading
*On
Off
Code ID (Default:L)
20H-7EH
Verification
*On
Off
Transmit Check Character
On
*Off
27 28

Enter Enter
End
End
Select Insertion (Default:00)
00H-02H
Truncate Leading Digit (Default:00)
00H-7EH
Truncate Last Digit (Default:00)
00H-7EH
Min. Length (Default:00)
00H-50H
Max. Length (Default:00)
00H-50H
Code 128
Reading
*On
Off
Code ID (Default:M)
20H-7EH
Verification
*On
Off
Transmit Check Character
On
*Off
29 30

Enter Enter
End
End
Truncate Leading Digit (Default:00)
00H-7FH
Truncate Last Digit (Default:00)
00H-7FH
Select Insertion (Default:00)
00H-02H
Min. Length (Default:00)
00H-7FH
Max. Length (Default:00)
00H-7FH
UCC/EAN128
On
*Off
FNC1 Transmit
On
*Off
FNC2 Checksum
On
*Off
31 32

Enter Enter
End
End
Interleaved 2 of 5
Reading
*On
Off
Code ID (Default:N)
20H-7EH
Verification
On
*Off
Transmit Check Character
*On
Off
Truncate Leading Digit (Default:00)
00H-7FH
Truncate Last Digit (Default:00)
00H-7FH
Select Insertion (Default:00)
00H-02H
Min. Length (Default:00)
00H-7FH
Max. Length (Default:00)
00H-7FH
33 34

Enter Enter
End
End
Industrial 2 of 5
Reading
On
*Off
Code ID (Default:O)
00H-7EH
Verification
On
*Off
Transmit Check Character
On
*Off
Truncate Leading Digit (Default:00)
00H-32H
Truncate Last Digit (Default:00)
00H-32H
Select Insertion (Default:00)
00H-02H
Min. Length (Default:00)
00H-32H
Max. Length (Default:00)
00H-32H
35 36

Enter Enter
End
End
Matrix 2 of 5
Reading
On
*Off
Code ID (Default:P)
20H-7EH
Verification
On
*Off
Transmit Check Character
*On
Off
Truncate Leading Digit (Default:00)
00H-50H
Truncate Last Digit (Default:00)
00H-50H
Select Insertion
00H-02H
Min. Length (Default:00)
00H-50H
Max. Length (Default:50H)
00H-50H
37 38
Other manuals for DS-210 Series
1
Table of contents