4
Dutchwest®Sequoia
2001049
Installation
SAFETY NOTICE: IF YOUR SEQUOIA HEATER IS NOT
PROPERLY INSTALLED, OPERATED AND MAINTAINED,
A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW
ALL INSTALLATION, OPERATION AND MAINTENANCE
DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPEC-
TION REQUIREMENTS IN YOUR AREA.
Before you begin the installation, review your plans to
conrm that:
• Your stove and chimney connector will be far enough
from combustible materials to meet all clearance require-
ments.
• The oor protector is large enough and is constructed
properly to meet all requirements.
• You have obtained all necessary permits from local
authorities.
Your local building ofcial is the nal authority for approving
your installation as safe and for determining that it meets
local and state codes.
The metal label permanently attached to the back of the
stove indicates that it has been tested to current UL and
ULC standards, and gives the name of the testing labora-
tory. Clearance and installation information is also printed
on the label. Local authorities generally will accept the label
as evidence that, when the stove is installed according to
the information on the label and in this manual, the instal-
lation meets codes and can be approved.
Codes vary in different areas, however. Before starting
the installation, review your plans with the local building
authority. Your local dealer can provide any additional
information needed.
For any unresolved questions about installation, refer
to the National Fire Protection Association’s publication
ANSI/NFPA 211-1988 Standard For Chimneys, Fireplaces,
Vents and Solid Fuel Burning Appliances. In Canada, the
equivalent publication is CSA CAN-B365, Installation Code
for Solid Fuel Burning Appliances and Equipment. These
standards are the basis for many national codes. They
are nationally recognized and are accepted by most local
authorities. Your local dealer or your local building ofcial
may have a copy of these regulations.
Important: Failure to follow these installation instructions
may result in a dangerous situation, including a chimney
or house re. Follow all instructions exactly, and do not
allow makeshift compromises to endanger property and
personal safety.
Chimney Types
Your Sequoia must be connected to a sound masonry chim-
ney that meets local codes, a relined masonry chimney that
meets local codes, or to an approved prefabricated metal
chimney. Whatever kind you use, the chimney and chimney
connector must be in good condition and kept clean.
Masonry Chimneys
If you use an existing masonry chimney, it must be inspected
to ensure safe condition before the stove is installed. Your
local professional chimney sweep, building inspector, or re
department ofcial will be able either to make the inspection
or to direct you to someone who can.
An inspection of the chimney must conrm that it has a lin-
ing. Do not use an unlined chimney. The chimney should
also be examined for cracks, loose mortar, other signs of
deterioration, and blockage. Repair any defects before the
chimney is used with your stove.
Unused openings in an existing masonry chimney must
be sealed with masonry to the thickness of the chimney
wall, and the chimney liner should be repaired. Openings
sealed with pie plates or wallpaper are a hazard and should
be sealed with mortar or refractory cement. In the event
of a chimney re, ames and smoke may be forced out of
these unused thimbles.
The chimney should be thoroughly cleaned before use.
A newly-built masonry chimney must conform to the
standards of your local building code or, in the absence
of a local code, to a recognized national code. Masonry
chimneys must be lined, either with code-approved ma-
sonry or pre-cast refractory tiles, stainless steel pipe, or
a code-approved, “poured-in-place” liner. The chimney’s
clean-out door must seal tightly.
ST241
chimney types
12/13/99 djt
Prefabricated Double-Wall
Insulated Chimney
Tile Lined
Masonry
Chimney
ST241
Fig. 2 If in sound condition and approved for use, either a