DVTEL CT-5322F User manual

CT-5322F/CT-5642F
Fixed Thermal
Analytic Camera
Quick Installation
Guide
Rev A1 September 24, 2015
The contents of this guide
may not be reproduced or
reprinted in whole or in part
without the express written
permission of DVTEL, INC.
DVTEL INC.
65 Challenger Road
Ridgefield Park, NJ 07660

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
ii

Document Information
iii
Table of Contents
1. Document Information ........................................................1
2. Introduction........................................................................5
2.1. Package Contents .......................................................... 6
2.2. Connector Panel ............................................................ 8
3. Installation and Mounting ...................................................9
3.1. Preparation.................................................................. 10
3.2. Items Required for Installation That Are Not Supplied 10
3.3. Attach the Base Mount to the Camera........................ 11
3.4. Connecting the Camera Cables.................................... 12
3.5. Mounting the Camera.................................................. 18
4. Accessing the Camera........................................................19
4.1. Device Discovery.......................................................... 19
4.2. Viewing Live Video....................................................... 20
5. Configuring Analytics.........................................................24
5.1. Configuring Depth Settings.......................................... 24
5.2. Configuring Rules......................................................... 25
Contacting DVTEL ....................................................................27

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
iv
List of Figures
Figure 1: System Installation........................................................... 5
Figure 2: Package Contents............................................................ 6
Figure 3: Connector Panel .............................................................. 8
Figure 4: Recommended Tools..................................................... 11
Figure 5: Attaching the Base Mount.............................................. 11
Figure 6: Cordgrip Parts................................................................ 12
Figure 7: Cables Inserted Through Locking Nut ........................... 12
Figure 8: Rubber Grommet........................................................... 13
Figure 9: Wires Inserted through Grommet .................................. 13
Figure 10: Rubber Grommet Inserted into Cordgrip ..................... 13
Figure 11: Assembling Sealing Nut............................................... 14
Figure 12: Tightening the Locking Nut.......................................... 14
Figure 14: Power Wires with Ferrite.............................................. 15
Figure 16: Camera with Ferrites Installed for Power Supply......... 15
Figure 15: Back Cover and White Desiccant ................................ 16
Figure 16: Covering the Connector Panel..................................... 17
Figure 17: Solar Shroud and Stem Bumpers................................ 17
Figure 18: Fully Assembled Camera............................................. 18
Figure 19: ActiveX Plug-in Message............................................. 20
Figure 20: Render.cab Plug-in Dialog Box.................................... 20
Figure 21: Windows Restart Dialog Box ....................................... 21
Figure 22: View Screen................................................................. 21
Figure 23: Depth Screen............................................................... 24
Figure 24: Rules Screen ............................................................... 25

Document Information
1
1. Document Information
Document Scope and Purpose
The purpose of this document is to provide instructions and installation
procedures for physically connecting the ioi Thermal CT-5322F/CT-5642F fixed
cameras. After completing the physical installation, additional setup and
configurations are required before video analysis and detection can commence.
Note:
This document is intended for use by technical users who have a basic
understanding of CCTV camera/video equipment and LAN/WAN
network connections.
Remarque:
Ce document est destiné aux utilisateurs techniciens qui possèdent des
connaissances de base des équipements vidéo/caméras de
télésurveillance et des connexions aux réseaux LAN/WAN.
Warning:
Installation must follow safety, standards, and electrical codes as well
as the laws that apply where the units are being installed.
Avertissement:
L'installation doit respecter les consignes de sécurité, les normes et les
codes électriques, ainsi que la législation en vigueur sur le lieu
d'implantation des unités.

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
2
Proprietary Rights and Non-Disclosure
This guide is delivered subject to the following restrictions and conditions:
This document contains proprietary information belonging to DVTEL,
Inc. This information is supplied solely for the purpose of assisting
explicitly the licensee of the DVTEL units.
No part of this document contents may be used for any other
purpose, disclosed to any third party or reproduced by any means,
electronic or mechanical, without the express prior written
permission of DVTEL, Inc.
DVTEL, Inc. makes no representations whatsoever about any other products or
trademarks mentioned in the manual. © DVTEL, Inc. 2015. All rights reserved.
Legal and Environmental Information
This product contains technology controlled under the U.S. Export Administration
Regulations (EAR). Diversion contrary to U.S. law is prohibited. This product has
been tested and found to comply with the limits of FCC (47 CFR) Part 15, Subpart
B, Class A and CES-003. This product complies with the European RoHS directive.
Disclaimer
Users of DVTEL products accept full responsibility for ensuring the suitability and
considering the role of the product detection capabilities and their limitation as
they apply to their unique site requirements. DVTEL, Inc. and its agents make no
guarantees or warranties to the suitability for the users’ intended use. DVTEL,
Inc. accepts no responsibility for improper use or incomplete security and safety
measures.
Failure in part or in whole of the installer, owner, or user in any way to follow the
prescribed procedures or to heed WARNINGS and CAUTIONS shall absolve
DVTEL, Inc. and its agents from any resulting liability. Specifications and
information in this guide are subject to change without notice.
Electrical Safety Notice and Warnings
SAVE ALL SAFETY AND OPERATING INSTRUCTIONS FOR FUTURE USE.
Although the unit is designed and manufactured in compliance with all applicable
safety standards, certain hazards are present during the installation of this
equipment.

Document Information
3
Camera Warnings
Warning:
1. Only qualified trained personnel should service and repair this
equipment.
2. Observe local codes and laws and ensure that installation and
operation are in accordance with fire, security and safety
standards.
3. The unit’s cover is an essential part of the product. Do not
open or remove it. Operating the unit without the cover poses
a risk of fire and shock hazards.
4. Do not disassemble the unit or remove screws. There are no
user serviceable parts inside the unit.
5. Operating the camera at voltage levels outside the specified
range may result in permanent damage to the unit and void the
product warranty.
6. The camera electronics and electronic interfaces are sensitive
to electrostatic discharge. Follow appropriate ESD procedures
when handling the camera and during installation.
7. Be sure not to expose the camera head to strong sunlight,
which could cause the camera to overheat.
8. This product must be connected to an IEEE 802.at-compliant
POE+ power source, or a UL listed Class 2 power supply rated
12-24 VDC or 24 VAC, minimum 20W. IEEE 802.3af PoE is NOT
supported.
9. For PoE+ installations, we strongly recommend using STP
cabling and an earth grounded end point to ensure proper ESD
immunity. For installations powered by AC or DC, a properly
earth grounded power source is strongly recommended. Any
other installation method may leave the camera at risk and
void the warranty.
10. If you use a power supply, make sure that the connection
matches the positive and negative polarity on the unit, and
protect against static electricity, ground faults and power
surges.

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
4
Avertissements relatifs à la Caméra
Avertissement:
1. Seul un technicien formé et qualifié est autorisé à entretenir et
à réparer cet équipement.
2. Respectez les codes et réglementations locaux, et assurez-vous
que l'installation et l'utilisation sont conformes aux normes
contre l'incendie et de sécurité.
3. Le cache de l'unité est une partie essentielle du produit. Ne les
ouvrez et ne les retirez pas. L'utilisation de l'unité sans cache
présente un risque d'incendie et de choc électrique.
4. Ne démontez pas l'unité et ne retirez pas ses vis. Aucune pièce
se trouvant à l'intérieur de l'unité ne nécessite un entretien par
l'utilisateur.
5. Toute utilisation de la caméra à des niveaux de tension n'étant
pas compris dans la fourchette indiquée peut endommager
l'unité de façon permanente et peut annuler la validité de la
garantie du produit.
6. L'électronique et les interfaces électroniques de la caméra sont
sensibles aux décharges électrostatiques. Suivez les
procédures ESD adéquates lors de toute manipulation de la
caméra et au cours de son installation.
7. Assurez-vous de ne pas exposer la tête de la caméra aux rayons
de soleil intenses qui pourraient surchauffer la caméra.
8. Ce produit doit être connecté à une source d'alimentation par
IEEE 802.at (PoE+) ou à une alimentation UL de Classe 2 de 12-
24 V CC ou 24 V AC, 20W minimum. IEEE 802.3af PoE est pas
pris en charge.
9. Pour les installations PoE+, nous recommandons fortement
d'utiliser des câbles STP et une liaison à la terre pour assurer
l'immunité face aux décharges électrostatiques. Pour les
installations alimentées par AC ou CC, une source d'alimentation
reliée à la terre est fortement recommandée. Toute autre méthode
d'installation peut comporter des risques pour la caméra et annuler
la garantie.
10. Si vous utilisez une alimentation, assurez-vous que le branchement
à l'alimentation corresponde aux polarités positive et négative sur
l'unité, et protéger l'unité contre l'électricité statique, les défauts de
mise à la terre et les surtensions.

Introduction
5
2. Introduction
This document provides information about the ioi Thermal CT-5322F/
CT-5642F fixed-mount, fixed focal length thermal camera that includes
integrated video analytics. The NTSC/PAL camera system is a hybrid analog/
Internet Protocol (IP) networked solution that supports the Open Network Video
Interface Forum (ONVIF™) Profile S standard.
Figure 1: System Installation

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
6
2.1.Package Contents
The unit package contains the following items:
Figure 2: Package Contents
Item
QTY
Description
1
1
CT-5322F/CT-5642F Fixed Thermal Analytic Camera
(with 90° RG179BU BNC adapter attached to the
connector panel)
2
1
Base mount
3
1
Back cover
4
1
Solar shroud
5
1
Liquid tight cordgrip
6
8
#6 32 x 5/8” screws (including spares)
7
3
Stem bumpers ( including one spare)
8
1
White silica gel desiccant for installation
9
1
Rubber O-ring (shown as installed on the cordgrip)
10
3
Sealing washers with gasket (including one spare)

Introduction
7
In addition, the following items are supplied:
QTY
Description
1
Package of four terminal connectors: 6-pin for
alarms and relay; 4-pin for audio (not currently
supported); 3-pin for power and ground; and
2-pin for RS-485 (not currently supported)
1
Locking Nut
2
Ferrites (for power and alarm leads)
1
Quick Installation Guide (this document)
Note:
Use PoE+ or a 12-24VDC or 24 VAC power source that supplies 20W.
IEEE 802.3af PoE is NOT supported.
Related information:
ioi Thermal CT-5322F/CT-5642F User and Installation Guide
HTML Edition Units User’s Guide
DNA User Manual

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
8
2.2.Connector Panel
The connector panel includes the following items:
Figure 3: Connector Panel
Item
Comment
Video Port
Connects the analog video coax cable between the camera and an
analog DVR.
Ethernet Port
Connects the network cable between the camera and the
network switch for network communication and powering the
unit. The PoE+ supply requires minimum 20W. IEEE 802.3af PoE is
NOT supported.
Reset Button
Resets the unit to full factory defaults. Hold for at least 6 secs.
Alarm In Pins
Connects two alarm inputs via the supplied 6-pin connector to the
marked 1, 2, and ground pins. Each alarm input pin should also be
connected to the ground pin (i.e., pin 1 + ground, or pin 2 +
ground).
Relay Out Pins
Connects the 6-pin connector to the marked NC, C, and NO pins.
The NC and NO pin should also be connected to the C pin
(i.e., NC + C, or NO + C).
Audio In/Out
Not currently supported.
RS-485 Pins
Not currently supported.
AC/DC Pins
Connects a male 3-pin connector from an AC or DC power supply
to the unit’s + (positive), –(negative), and ground leads.

Installation and Mounting
9
3. Installation and Mounting
The physical installation of the unit is the first phase of making the unit
operational in a security plan. The goal is to physically place the unit, connect it
to other devices in the system, and to establish IP network connectivity.
When finished with the physical installation, refer to the ioimage Thermal
CT-5322F/CT-5642F User and Installation Guide to complete the second phase of
installation, which is the setup and configuration of the unit.
Caution:
To avoid damage from overheating or unit failure, assure that there is
sufficient temperature regulation to support the unit’s cooling/
heating requirements. Operating temperature should be kept in the
range -40° to 60°C (-40° to 140°F), with no more than 95% non-
condensing humidity.
Attention:
Afin d'éviter tout dommage dû à une surchauffe ou toute panne de
l'unité, assurez-vous que la régulation de température est suffisante
pour répondre aux exigences de l'unité (refroidissement/chauffage).
La température de fonctionnement doit être maintenue dans la plage
de température spécifiée pour le produit (-40° à 60°C/-40° à 140°F,
sans condensation d'humidité supérieur à 95%).

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
10
3.1.Preparation
Read the instructions in this chapter thoroughly before installing the camera.
Following are additional considerations for outdoor installation:
Always use weatherproof equipment, such as boxes, receptacles,
connectors, etc.
For electrical wiring, use the properly rated sheathed cables for
conditions to which the cable will be exposed (for example,
moisture, heat, UV, physical requirements, etc.).
Plan ahead to determine where to install infrastructure
weatherproof equipment. Whenever possible, ground components
to an outdoor ground.
Use best security practices to design and maintain secured camera
access, communications infrastructure, tamper-proof outdoor
boxes, etc.
To minimize the effects of EMI (electromagnetic interference) and RFI
(radio frequency interference), consult your reseller.
3.2.Items Required for Installation That Are Not
Supplied
The following items are required for installation, but are not included in the
package:
Power source (PoE+ switch, 12-24VDC or 24VAC power supply)
Shielded Twisted Pair (STP) cable if using a PoE+ switch
Cat 5 Ethernet cable for network connection without a PoE+ switch
Tripod or mounting bracket for mounting the camera
One #2 Phillips head screwdriver
One open-end, 1-inch (25.4mm) wrench or adjustable wrench
One 6-inch (152mm) scale or ruler
Electric or manual torque screwdriver set to 10 inch-pounds
(1.23 Newton meters)

Installation and Mounting
11
Hex wrench
RJ45 connector
RJ45 crimping tool
Coax cable
Coax cable cutter/stripper
BNC connector
BNC crimping tool
Figure 4: Recommended Tools
3.3.Attach the Base Mount to the Camera
To attach the base mount to the camera
Screw the base mount into the camera body with eight #6 screws.
Figure 5: Attaching the Base Mount
Using the electric screwdriver, tighten the fasteners to about 8 inch-
pounds (0.904 newton meters) of torque.

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
12
3.4.Connecting the Camera Cables
In order to connect the camera to the network, take the analog video cable,
network cable, power supply leads (if an AC or DC supply is used), alarm, and
relay wiring from the wall at the installation site.
In order to connect the wires to the connectors on the camera’s connector panel,
they must be wired through the supplied cordgrip. Wires must be fed from the
wall through the camera’s mounting assembly, through the opening on the
underside of the camera, through the camera body, and out of the opening on
the camera’s connector panel. The wires then must be attached to connectors
before attaching them to the connector panel.
To connect the camera cabling
Disconnect power from any previously installed cables.
Remove the cordgrip parts from the package.
Figure 6: Cordgrip Parts
Feed the wires through the locking nut, then through the camera body
and out of the opening on connector panel.
Figure 7: Cables Inserted Through Locking Nut
Feed the wires through the cordgrip body as seen in the picture above.

Installation and Mounting
13
Place the orange O-ring over the cordgrip and feed the wires through
the cordgrip body and sealing nut as seen in Figure 9.
Insert the Ethernet cable through the center opening of the rubber
grommet. Then insert the other wires through the small holes in the
rubber. The wires should be spaced several holes apart. Nineteen (19)
AWG is recommended for the power leads. Twenty (20) AWG is
recommended for all wires other than the Ethernet and video cables.
The flat side of the grommet should be on the inside of the cordgrip.
Figure 8: Rubber Grommet
Figure 9: Wires Inserted through Grommet
If needed, use a #2 Phillips head screwdriver to widen the hole in the
center of the rubber grommet.
If needed, pierce the smaller holes on the outer perimeter of the
rubber grommet for the video cable, AC/DC supply wiring, alarm, and
relay leads.
Measure about 4-1/2” (114mm) of cable from the end of all wires to
the rubber grommet.
Push the rubber grommet into the cordgrip body so that the grommet
is flush with the slotted side of the body and the flat side of the sealing
nut is facing it.
Figure 10: Rubber Grommet Inserted into Cordgrip

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
14
Insert the wires through the sealing nut and screw the nut so that it is
closes tightly on the cordgrip body. Use the hex wrench to tighten the
nut to 50-55 inch-pounds (5.65-6.215 newton meters) of torque so that
the cordgrip is securely fastened.
Figure 11: Assembling Sealing Nut
Insert the assembled cordgrip into the opening on the connector panel.
The side including the exposed screw thread and rubber O-ring should
be inserted first.
Hand-tighten the locking nut inside the camera body.
Figure 12: Tightening the Locking Nut
Use the hex wrench to tighten the nut to approximately 8 in-lbs.
(0.9 newton meters) of torque so that the cordgrip is securely fastened.
Using a striping tool, attach an RJ45 connector (not supplied) to the
Ethernet cable and an RJ179BU male BNC crimp connector (not
supplied) to the video cable. Crimp the wires onto the connectors.

Installation and Mounting
15
If the camera is connected to an alarm or a 12 or 24 volt power supply,
it is necessary to insert the wires through the supplied ferrites in order
to comply with EMI emission standards.
Figure 13: Power Wires with Ferrite
Attach the supplied plugs to the wires. Crimp the wires onto the
connectors.
If using a power supply, connect the 3-pin male terminal block
connector from the power supply to the AC/DC power input.
Insert the connectors and plugs into the connector panel.
Figure 14: Camera with Ferrites Installed for Power Supply

CT-5322F/CT-5642F Fixed Thermal Analytic Camera QIG
16
Note:
If you use a PoE+ switch, in order to ensure a proper earth
ground between the camera and the PoE+ switch, we
strongly recommend using Shielded Twisted Pair (STP)
cabling. Installations of ioimage Thermal cameras with STP
cabling and a properly earth grounded PoE+ switch are
tested to comply with industry immunity standards for
electrostatic discharge (ESD). Any other installation
method may leave the camera at risk and void the
warranty.
Reconnect power to the cables.
Check for a steady LED indication on the Ethernet cable RJ45 connector
to confirm connection to the IP network. The status LED indicators are:
LED 1: Steady green for 10MB connection or flashing green for
activity.
LED 2: Steady amber for 100MB connection or flashing amber for
activity.
Insert the supplied white desiccant inside the back cover.
Figure 15: Back Cover and White Desiccant
Other manuals for CT-5322F
1
This manual suits for next models
1
Table of contents
Other DVTEL Thermal Camera manuals