Important notes for the All Purpose Melter:
•Please read all instructions before attempting to set-up your Melter.
•Put enough water in it to check for leaks.
•Keep about 2” of water above the perforated, stainless steel plate.
•Do not use an extension cord or power strip.
•Hard Water or Water that may cause corrosion to your element… If you have this type of tap water
or you are in doubt use RO water, distilled or bottled water.
•Consider hiring an Electrician or Plumber to install your tank.
DO NOT PLUG IN UNTIL THE ELEMENT IS COMPLETELY SUBMERGED IN WATER!
THERE IS NO FIRE HAZARD BUT IT WILL DESTROY YOUR ELEMENT.
Heater/Thermostat Installation:
•Your Heater/Thermostat is supplied with a cord and plug.
o1500 Watt Heaters are 120 volts and use a standard 3-prong plug.
•If wiring direct to an outlet or electrical panel hire an Electrician.
International Customers; you will need to use the proper style plug for your country. If
you are not sure, consult an electrician.
Note: Make Sure All threads have been wrapped with Teflon Tape
1. Insert the Heater Tube into the 1 ¼” (32mm) Coupling. Make sure it fits in
freely. Note: the Coupling is a female fitting
2. Screw the Heater/Thermostat into the Coupling.
3. Turn the Heater/Thermostat until it is tight and the cord is not at the bottom of the box. See Picture
Below.
4. Installing the Capillary Bulb and Tube:
oCarefully… uncoil about 18” (46cm) of the Capillary Tube. Do
not kink or make any sharp bends in it.
oLocate the Capillary Tube Inlet, left of the Heater Box.
oInsert the Capillary Bulb into the hole all the way in until it
stops.
oSlide the Capillary Tube Plug down the tube and push it
firmly into the hole. This will lock the Capillary Tube in place
and seal the hole.
oCarefully coil up the excess Capillary Tube and secure it with
a piece of tape or tie-wrap behind the box.
oBe careful that you do not bend or kink the Capillary Tube.
Power Cord