EarthQuake IG800W User manual

GAS/OIL
RATIO
50:1
Operator’s Manual
Original Operating Instructions
800 Watt
Inverter Generator
P/N: OMIG800W
ECN: 9880
REV2: 09/03/13
© 2013 Ardisam, Inc.
All Rights Reserved
Get parts online at
www.GetEarthquake.com
Product #: IG800W

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-52
INTRODUCTION
Congratulations on your investment in quality. Thank you for purchasing an 800 watt inverter generator from Earthquake™. We have
worked to ensure that the IG800W meets the highest standards for usability and durability. With proper care, your generator will
provide many years of service.
Please read this entire manual before use. Earthquake reserves the right to change, alter or improve the product and this
document at any time without prior notice.
CONTENTS
Registration ........................................................................................................................................................................................................................................2
Warnings & Safety Precautions................................................................................................................................................................................................3-9
Features & Controls.................................................................................................................................................................................................................10-11
Specications...................................................................................................................................................................................................................................11
Pre-Operation Check.....................................................................................................................................................................................................................12
Operation...................................................................................................................................................................................................................................13-14
Maintenance .............................................................................................................................................................................................................................15-17
Transport & Storage.......................................................................................................................................................................................................................18
Troubleshooting & Repair ....................................................................................................................................................................................................18-19
Electrical Wire Diagram ................................................................................................................................................................................................................20
Parts Explosion & Parts List..................................................................................................................................................................................................21-23
Warranty .....................................................................................................................................................................................................................................25-27
FEDERAL EMISSIONS INFORMATION
Earthquake warrants to the retail purchaser, that this small, o-road engine was designed,
built and equipped to conform at the time of initial sale to all applicable regulations of the
U.S. Environmental Protection Agency (EPA).
REGISTRATION AND SERVICE
Record the model number and serial number in the space provided for easy reference when ordering parts or requesting technical
support. Excluding emissions-related warranty items, the warranty is valid only if the completed registration is received by Ardisam
within 30 days of purchase. (SEE WARRANTY SECTION FOR MORE INFORMATION.) You can register your warranty online by visit-
ing www.getearthquake.com, or by mailing it to: Ardisam, 1160 Eighth Avenue, Cumberland, WI 54829. For additional information,
call Earthquake customer service at (800) 345-6007 Mondays through Fridays from 8 a.m. to 5 p.m. CST.
Read and keep this manual for future reference. This manual contains important information on SAFETY, ASSEMBLY, OPERA-
TION, AND MAINTENANCE. The owner must be certain that all the product information is included with the unit. This informa-
tion includes the MANUAL, the REPLACEMENT PARTS and the WARRANTIES. This information must be included to make sure
state laws and other laws are followed. This manual should remain with the product even if it is resold.
OWNERSHIP RECORDS
Owner’s Name:
Owner’s Address:
City: State/Province: Zip Code/Postal Code:
Model Number: Serial Number:
Date of Purchase:
Notes:
ARDISAM,INC.
11608thAvenue | Cumberland,WI54829 | USA
SerialNo.
Model:IG800W Year: 2013
Type:Inverter Generator
Max.AC Output: 800 W
Mass:9.5 kg L
WA
(dBA): 58
16044
serial number
location

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 3
WARNINGS & SAFETY PRECAUTIONS
OWNER’S RESPONSIBILITY
Accurate assembly and safe and eective use of the machine is
the owner’s responsibility.
• Readandfollowallsafetyinstructions.
• Carefullyfollowthepre-operationcheckinstructions.
• Maintainthemachineaccordingtodirectionsandschedule
included in this Earthquake operator’s manual.
• Ensurethatanyonewhousesthemachineisfamiliarwithall
controls and safety precautions.
SPECIAL MESSAGES
Your manual contains special messages to bring attention to
potential safety concerns, machine damage as well as helpful
operating and servicing information. Please read all the infor-
mation carefully to avoid injury and machine damage.
NOTE: General information is given throughout the manual
that may help the operator in the operation or service of the
machine.
This symbol points out important safety instruc-
tions which if not followed could endanger your
personal safety or the safety of your equipment.
Read and follow all instructions in this manual be-
fore attempting to operate this equipment.
BEFORE OPERATING ENGINE:
Please read this section carefully. Read entire operating and
maintenance instructions for this product. Failure to follow
instructions could result in serious injury or death. Operate the
machine according to the safety instructions outlined here and
inserted throughout the text. Anyone who uses this machine
must read the instructions and be familiar with the controls.
WARNING
WARNING INDICATES A HAZARD WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH OR SERIOUS IN
JURY AND/OR PROPERTY DAMAGE.
CAUTION
CAUTION INDICATES YOU CAN BE HURT OR YOUR
EQUIPMENT DAMAGED IF THE SAFETY INSTRUC
TIONS THAT FOLLOW THIS SIGNAL WORD ARE NOT
OBEYED.
WARNING
CALIFORNIA PROPOSITION 65 WARNING
ENGINE EXHAUST FROM THIS PRODUCT CONTAINS
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER, BIRTH DEFECTS, OR OTHER RE
PRODUCTIVE HARM.
IMPORTANT
INDICATES HELPFUL INFORMATION FOR PROPER AS
SEMBLY, OPERATION, OR MAINTENANCE OF YOUR
EQUIPMENT.
WARNING
YOU MUST READ, UNDERSTAND AND COMPLY WITH
ALL SAFETY AND OPERATING INSTRUCTIONS IN
THIS MANUAL BEFORE ATTEMPTING TO SETUP AND
OPERATE YOUR MACHINE.
FAILURE TO COMPLY WITH ALL SAFETY AND
OPERATING INSTRUCTIONS CAN RESULT IN LOSS OF
MACHINE CONTROL, SERIOUS PERSONAL INJURY TO
YOU AND/OR BYSTANDERS, AND RISK OF EQUIPMENT
AND PROPERTY DAMAGE. THE TRIANGLE IN THE TEXT
SIGNIFIES IMPORTANT CAUTIONS OR WARNINGS
WHICH MUST BE FOLLOWED.
Intended Use /
Foreseeable Misuse
IMPORTANT: This is a motorized inverter generator that
processes DC energy into smooth AC power. It is a pedestrian-
use product, with a gasoline-fueled internal combustion
engine to generate usable power. It shall not be used for any
other purpose.
DANGER
DANGER INDICATES A HAZARD WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH OR SERIOUS IN
JURY AND/OR PROPERTY DAMAGE.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-54
GENERAL SAFETY RULES
• Read, understand, and follow all instructions on the machine
and in the manual(s). Be thoroughly familiar with the controls
and the proper use of the machine before starting.
• Use this equipment for its intended purpose only.
• Familiarize yourself with all of the safety and operating
decals on this equipment and on any of its attachments or
accessories.
• Never operate in an enclosed area, in a vehicle or indoors
even if doors and windows are open.
• Only allow responsible individuals who are familiar with the
instructions to operate the machine. Do not allow children
to operate this machine. Do not allow adults to operate the
machine without proper instruction.
• Operate generator only on level surfaces and where it will
not be exposed to excessive moisture, dirt, dust or corrosive
vapors.
• Keep hands, feet, clothing, etc., away from drive belts, fans
and other moving parts. Never remove any fan guard or
shield while the unit is operating.
• Do not operate the machine without proper guards or other
safety protective devices in place.
• See manufacturer’s instructions for proper operation and
installation of accessories. Only use accessories approved
by the manufacturer.
• Do not operate or work on this product when fatigued or
under the inuence of alcohol, drugs or other medication
which can cause drowsiness or aect your ability to operate
this machine safely.
• Do NOT operate generator in rain or snow.
• If the equipment should start to vibrate abnormally, stop the
engine (motor), ip the ON/OFF switch to the OFF position.
Check immediately for cause.Vibration is generally a warning
of trouble. If the noise or vibrations of the machine increase,
stop immediately and perform an inspection.
• Never leave the machine unattended when the engine is
running. Flip the ON/OFF switch to the OFF position.
• Regularly inspect the machine. Make sure parts are not
damaged or loose.
• Certain parts of the generator get extremely hot during
operation. Keep clear of the generator until it has cooled to
avoid severe burns.
• Donot altertheconstruction ofthegeneratoror changecontrols
which might create an unsafe operating condition.
• Keep all screws, nuts and bolts tight.
• Do not transport the machine from one place to another
with the engine running.
• Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts and may result in
dangerous operating conditions from leaking exhaust gases,
fuel leakage, oil leakage, etc.
• When moving the packaged machine, always do so with a
partner.
• Check local regulations for any restrictions on the use of
this machine.
WARNING
GROUND GENERATOR WITH THE APPROPRIATE
AMOUNT OF LEAD FOR CURRENT CAPACITY.
DIAMETER:
.005 IN/AMP

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 5
ENGINE SAFETY PRECAUTIONS
Warning Carbon Monoxide Poisoning
Engines give off carbon monoxide, an odorless, colorless,
poisonous gas.Carbonmonoxidemaybe present evenifyoudo
notsmellor seeanyengineexhaust.Breathingcarbon monoxide
can cause nausea, fainting or death, in addition to drowsiness,
dizziness and confusion. If you experience any of these
symptoms, seek fresh air and medical attention immediately.
If your product comes with a separate engine manual, be
sure to read and follow all safety and warning precautions
outlined there, in addition to any in this manual.
WARNING
ENGINES GIVE OFF CARBON MONOXIDE, AN ODOR
LESS, COLORLESS, POISONOUS GAS. CARBON MON
OXIDE MAY BE PRESENT EVEN IF YOU DO NOT SMELL
OR SEE ANY ENGINE EXHAUST. BREATHING CAR
BON MONOXIDE CAN CAUSE NAUSEA, FAINTING OR
DEATH, IN ADDITION TO DROWSINESS, DIZZINESS
AND CONFUSION.
IF YOU EXPERIENCE ANY OF THESE SYMPTOMS, SEEK
FRESH AIR AND MEDICAL ATTENTION IMMEDIATELY.
PRODUCTSPECIFIC SAFETY RULES
• The generator produces dangerously high voltage
when in operation. Avoid contact with bare wires,
terminals, connections, etc., while the unit is running,
even on equipment connected to the generator. Ensure all
appropriate covers, guards and barriers are in place before
operating the generator.
• Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet are
wet. DANGEROUS electrical shock may result.
• The generator must be earth grounded in accordance with all
relevant electrical codes and standards before operating. A
10 gauge copper wire should be used to connect the ground
terminal of the generator to a grounding rod. A wire too
thin may not provide sucient electrical current carrying
capacity to be an adequate ground path.
• Use a ground fault circuit interrupter in any damp or highly
conductive area (such as metal decking or steel work).
• Do not use worn, bare, frayed or otherwise damaged
electrical cord sets with the generator.
• In case of accident caused by electric shock, immediately
shut down the source of electrical power. If this is not
possible, attempt to free the victim from the live conductor.
AVOID direct contact with the victim. Use a non-conducting
implement, such as a rope or board, to free the victim from
the live conductor. If the victim is unconscious, apply rst
aid and get immediate medical help. Preventing Carbon Monoxide Poisoning
• Always start and run engine outdoors. Do not start or run
engine in an enclosed area, even if doors or windows are open.
• Never try to ventilate engine exhaust indoors. Carbon
monoxide can reach dangerous levels very quickly.
• Never run engine outdoors where exhaust fumes may be
pulled into a building.
• Never run engine outdoors in a poorly ventilated area where
the exhaust fumes may be trapped and not easily taken
away. (Examples include: in a large hole or areas where hills
surround your working area.)
• Never run engine in an enclosed or partially enclosed area.
(Examples include: buildings that are enclosed on one or
more sides, under tents, car ports or basements.)
• Always run the engine with the exhaust and muer pointed
in the direction away from the operator.
• Never point the exhaust muer towards anyone. People
should always be many feet away from the operation of the
engine and its attachments.
• Do not change the engine governor settings or over-speed
the engine.
DANGER
USING A GENERATOR INDOORS CAN KILLYOU IN MIN
UTES DUE TO CARBON MONOXIDE.
NEVER USE INSIDE A
HOME OR GARAGE. ONLY USE OUTSIDE, FAR
AWAY FROM WINDOWS,
DOORS AND VENTS.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-56
CAUTION
HOT GASES ARE A NORMAL BYPRODUCT OF A FUNC
TIONING INTERNAL COMBUSTION ENGINE. FOLLOW
ALL SAFETY INSTRUCTIONS TO PREVENT BURNS AND
FIRES.
DO NOT ALTER/MODIFY ENGINE:
NEVER ALTER OR MODIFY THE ENGINE FROM THE
FACTORY. SERIOUS INJURY OR DEATH MAY OCCUR IF
ENGINE IS MODIFIED OR ALTERED.
WHEN WORKING ON OR REPLACING PARTS FOR THE
ENGINE OR PRODUCT, YOU MUST ALWAYS FLIP THE
ON/OFF SWITCH TO THE OFF POSITION.
Gasoline Fires and Handling Fuel Safely
Use extra care in handling gasoline and other fuels. They are
ammable and vapors are explosive.
• When storing extra fuel be sure that it is in an appropriate
container and away from any re hazards.
• Prevent re and explosion caused by static electric discharge.
Use only nonmetal, portable fuel containers approved by the
Underwriter’s Laboratory (U.L.) or the American Society for
Testing & Materials (ASTM).
• Always ll fuel tank outside in a well ventilated area. Never
fill your fuel tank with fuel indoors. (Examples include:
basement, garage, barn, shed, house, porch, etc.) Never
ll tank near appliances with pilot lights, heaters, or other
ignition sources. If the fuel has to be drained, this should
be done outdoors. The drained fuel should be stored in a
container specically designed for fuel storage or it should
be disposed of carefully.
• Never remove the fuel cap or add fuel with the engine
running. Stop engine and allow to cool before lling.
• Do not smoke.
• Never drain fuel from engine in an enclosed area.
• Always wipe up excess (spilled) fuel from engine before
starting. Clean up spilled fuel immediately. If fuel is spilled,
do not start the engine but move product and fuel container
from area. Clean up spilled fuel and allow to evaporate and
dry after wiping and before starting.
• Allow fuel fumes/vapors to escape from the area before
starting engine.
• Test the fuel cap for proper installation before starting and
using engine.
• Always run the engine with fuel cap properly installed on
the engine.
• Never smoke while relling engine fuel tank.
• Do not store engine with fuel in fuel tank indoors. Fuel and
fuel vapors are highly explosive.
• Never pour fuel from engine fuel tank.
• Never siphon fuel by mouth to drain fuel tank.
• Always have an adult fill the fuel tank and never allow
children to ll the engine.
• Never allow an adult or anyone under the inuence of drugs
or alcohol to ll engine.
• When storing gasoline or equipment with fuel in the tank,
store away from furnaces, stoves, water heaters or other
appliances that have a pilot light or other ignition source
because they can ignite gasoline vapors.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 7
BURNS AND FIRES
The muer, muer guard and other parts of the engine be-
come extremely hot during the operation of the engine. These
parts remain extremely hot after the engine has stopped.
Prevention of Burns and Fires
• Neverremovethemuerguardfromtheengine.
• Nevertouchthemuerguardbecauseitisextremelyhot
and will cause severe burns.
• Never touchpartsofthe enginethatbecomehot after
operation.
• Alwayskeepmaterialsanddebrisawayfrommuerguard
and other hot parts of the engine to avoid res.
CHILDREN AND BYSTANDERS
Tragic accidents can occur if the operator is not alert to the
presence of children and/or bystanders. Never assume that
others will remain where you last saw them.
• Keep the area of operation clear of all persons, especially
small children and pets. Keep children under the watchful
care of a responsible adult.
• Never allow children to operate the machine.
SERVICE
• Always stop the engine whenever you leave the equipment,
before cleaning, repairing or inspecting the unit. Engine
should be turned o and cool. Never make adjustments or
repairs with the engine (motor) running. Flip the ON/OFF
switch to the OFF position to prevent accidental starting.
• Always wear eye protection when you make adjustments or
repairs.
• Keep all nuts and bolts tight and keep equipment in good
condition.
• Never tamper with safety devices. Check their proper
operation regularly.
• When servicing or repairing the machine, do not tip the
machine over or up unless specically instructed to do so in
this manual. Service and repair procedures can be done with
the machine in an upright position. Some procedures will be
easier if the machine is lifted on a raised platform or working
surface.
• To reduce re hazard, keep machine free of grass, leaves or
other debris build-up. Clean up oil or fuel spillage. Allow
machine to cool before storing.
• Clean and replace safety and instruction decals as necessary.
• To guard against engine over-heating, always have engine
lters mounted and clean.
• Inspect machine before storage. When not in use, ip the
ON/OFF switch to the OFF position and store indoors in a
dry place locked or otherwise inaccessible to children.
• Use only original equipment parts from Earthquake,
including all nuts and bolts.
• Avoid connecting the generator to commercial power
outlets.
• Avoid connecting the generator in parallel with any other
generator.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-58
SAFETY DECALS
This IG800W inverter generator has been designed and manufactured to provide you with the safety and reliability you would expect
from an industry leader in powered chore equipment manufacturing.
Reading this manual and the safety instructions it contains will provide you with the necessary basic knowledge to operate this
equipment safely and eectively.We have placed a safety decal on the generator to remind you of some of this important information
while you are operating the unit.
These important safety decals are illustrated below, and are shown here to help familiarize you with the location and content of
the safety messages you will see as you perform normal operations. Please review these decals now, and if you have any questions
regarding its meaning or how to comply with these instructions, reread the complete safety instruction text in this manual. For
additional questions European customers may contact their local dealer and US customers must call Earthquake customer service.
Should a decal become unreadable because of being worn, faded, or otherwise damaged during the use of your IG800W, please use
the part number information provided to order a replacement label. European customers can order from their local authorized dealer
and US customers can order by calling Earthquake customer service. These decals are easily applied, and will act as a constant visual
reminder to you, and others who may use the equipment, to follow the safety instructions necessary for safe, eective operation of
your inverter generator.
16036
ATTENTION
CAUTION
Hot Surface, Carbon Monoxide, Keep Distance.
Muer area is hot and ejects poisionous carbon monoxide.
Touching muer panel, operating unit in closed area, and not
keeping distance may result in death or injury.
Surface chaude, monoxyde de carbone, rester à l’écart.
Le pot d’échappement est chaud et dégage du monoxyde de
carbone toxique. Le fait de toucher le panneau d’échappement,
d’utiliser l’appareil dans un espace fermé et de se tenir trop
près présente un danger de mort ou de blessure. 16037
WARNING AVERTISSEMENT
Dangerous when wet.
Operate unit in dry area. Failure to operate in dry area may result in death or injury.
Dangereux en présence d’humidité.
Utiliser l’appareil dans un endroit sec. L’utilisation ailleurs que dans un
endroit sec présente un danger de mort ou de blessure.
Shock hazard.
Unit must be grounded. Failure to ground unitmay result in death or injury.
Danger de choc électrique.
L’appareil doit être relié à la terre. Un appareil non relié à la terre présente
un danger de mort ou de blessure.
Unit is heavy.
Team lift with a partner. Failure to team lift may result in death or injury.
L’appareil est lourd.
Le soulever à deux personnes. Le levage par une seule personne présente
un danger de mort ou de blessure.
Read owner’s manual before operating this machine.
Failure to follow operating instructions could result in death or serious injury.
Lire le mode d’emploi avant d’utiliser cette machine.
Le non-respect des instructions d’utilisation présente un danger de mort
ou de blessure grave.
16041
ARDISAM, INC.
1160 8th Avenue | Cumberland, WI 54829 | USA
Serial No.
Model: IG800W Year: 2013
Type: Inverter Generator
Max. AC Output: 800 W
Mass: 9.5 kg LWA (dBA): 58
16044
CAUTION
ATTENTION
Before operating,
add specied engine
oil to crankcase
(see manual).
Vous devez ajouter
de l’huile-moteur
avant de démarrer
le moteur. (voir le
manuel).
16045
P/N: 16041
IG800W MULTI WARNING DECAL
Read Manual, Dangerous when
Wet, Shock Hazard, Unit is Heavy.
P/N: 16037
IG800W MULTI
WARNING DECAL 2
Hot Surface, Carbon
Monoxide, Keep Distance
P/N: 16044
IG800W SERIAL
NUMBER DECAL
Product Name Plate
with Serial Number
P/N: 16036
IG800W EXHAUST
WARNING DECAL
Hot Surface, Carbon
Monoxide, Keep Distance
P/N: 16045
IG800W NO OIL
WARNING TAG
Add Specied Engine Oil

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 9
SPARK PLUG
BOUGIE
16034
16035
OFF
ARRÊT
ON
MARCHE
16038
AVERTISSEMENT
WARNING
Risque d’incendie.
Couper le moteur et le laisser refroidir avant de
faire le plein d’essence.
Fire hazard.
Shut o and cool engine prior to adding fuel.
STARTING INSTRUCTIONS
1. Open fuel cap vent and ip enigne switch
to the “ON”position
2. Turn fuel valve to the “ON” position
3. Push the primer bulb 6 times with the
choke in the “OFF” position
4. Push choke lever to the “ON” position
5. Pull 6 times; if it does not start
prime again and repeat
6. If it still does not start, call 800-345-6007
INSTRUCTIONS DE DÉMARRAGE
1. Ouvrir le reniard du bouchon de carburant et mettre
l’interrupteur du moteur en position «Marche»
2. Mettre le robinet de carburant en position «Marche»
3. Enfoncer la poire d’amorçage 6 fois avec le volet de départ
en position «Désengagé»
4. Pousser le volet de départ jusqu’en position «Engagé»
5. Tirer 6 fois; si le moteur ne démarre pas, réamorcer et répéter
6. S’il ne démarre toujours pas, appeler le 800-345-6007
PRIMER BULB
POIRE D’AMORÇAGE
FUEL SHUT-OFF
ROBINET DE CARBURANT
.35 L 10W30
16040
16043
AVERTISSEMENT
WARNING
Pas d’E85.
Utiliser du supercarburant sans plomb. L’E85 peut
endommager le moteur.
No E85.
Use premium unleaded. E85 may cause damage.
16061
RUN CHOKE
MARCHE ÉTRANGLÉ
P/N: 16043
IG800W NO E85
WARNING DECAL
Use Premium
Unleaded Gasoline
P/N: 16038
IG800W FIRE HAZARD
WARNING DECAL
Engine Fuel is Flammable
P/N: 16035
IG800W FUEL
ON-OFF DECAL
Fuel Valve ON and O
P/N: 16034
IG800W SPARK PLUG
ACCESS DECAL
Spark Plug Location
P/N: 16040
IG800W STARTING
PROCEDURE DECAL
Starting Instructions and
Engine Oil Type
P/N: 16061
CHOKE GENERATOR DECAL
Run and Choke

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-510
FEATURES & CONTROLS
1 2 3 4 5
7 8 9 10 11 12 13
15 16
18 19
6
17
20 21
14
1. Economy control switch
2. Fuel tank
3. Spark plug
4. Muer
5. Carrying handle
6. Choke lever
7. Output light
8. Overload indicator light
9. Oil warning light
10. DC protector
11. Ground (earth) terminal
12. DC receptacle
13. AC receptacle
14. Engine switch
15. Fuel strainer
16. Fuel tank cap
17. Primer bulb
18. Recoil starter
19. Fuel valve
20. Oil ller cap
21. Air lter cover

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 11
AC VOLTAGE 60Hz - 100, 120V, 240V
MAX OUTPUT 800 watts
RATED OUTPUT 700 watts
DC OUTPUT 12V / 3.0A
ENGINE DISPLACEMENT 40cc
ENGINE TYPE 4-cycle
NOISE LEVEL 7m 58 dB
FUEL TANK CAPACITY 0.55 gallons (2.1 liters)
FUEL TYPE Minimum 87 octane gasoline with
NO ethanol content
NOTE: If using an ethanol blended
fuel, a fuel stabilizer, mixed to
manufacturer specications, is
recommended
RUN TIME 25% load 8.2 hours
OIL TANK CAPACITY 11.8 ounces (.35 liter)
OIL TYPE 10W-30 (SJ, SL or better)
SPARK PLUG CMR6A (TORCH)
SPARK PLUG GAP 0.6 - 0.7 mm
WEIGHT OF UNIT 21 lb
UNIT SIZE L xW xH inches) 15.6 x 8.2 x 14.0
SPECIFICATIONS
OIL WARNING SYSTEM
When the oil level reaches a low level, the engine will stop
automatically. In order to restart the engine, the oil must be
relled.
NOTE:
It is important to check the oil level before each use.
ENGINE SWITCH
The engine switch must be in the ON position to start and run
the generator. Flip the engine switch to the STOP position to
stop the generator. SEE FIGURE 1
NOTE:
It is recommended to keep the engine switch in the OFF
position while the generator is not in use.
ECONOMY CONTROL SWITCH
When the economy control switch is in the ON position, the
economy control unit controls the engine speed according to
the connected load. The results are better fuel usage and lower
noise levels. SEE FIGURE 1
NOTE:
When starting the generator and while plugging in and
starting connected devices, make sure the economy control switch
is in the OFF position. Flip economy switch to the ON position once
all units are running smoothly.
DC CIRCUIT PROTECTOR
The DC circuit protector turns o automatically when the load
exceeds the generator’s rated output. SEE FIGURE 1
NOTE:
If generator turns o due to access load, reduce the load to
within specic generator rated output levels.
FUEL TANK CAP AIR VENT
The fuel tank cap is provided with an air vent knob to stop fuel
ow. The air vent knob must be turned clockwise to the OPEN
position to run the generator. This will allow for fuel ow in
the engine. When the generator is not in use, turn the air vent
knob counterclockwise to the CLOSED position. This will block
air ow to the fuel tank. SEE FIGURE 2
FUEL VALVE
The fuel valve must be in the ON position to run the genera-
tor. When the generator is not in use, turn the fuel valve to the
OFF position. SEE FIGURE 2
FIGURE 1
ENGINE SWITCHECON. SWITCH DC PROTECTOR
ON OFF
CLOSE
OPEN
CLOSEOPEN
ONOFF
FIGURE 2

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-512
upper level
lower level
oil ll cap
PREOPERATION CHECK
NOTE: Pre-Operation checks should be made each time the
generator is used.
CHECK FUEL
Make sure there is sucient fuel in the tank. If fuel is low, rell
with a minimum 87 octane gasoline with NO ethanol content.
• Besuretousethefuellterscreenonthefuelstrainerneck.
• Fueltankcapacityis.55gallons.
Filling Fuel Tank:
1. Make sure the generator is not running and is completely cool
before relling the fuel tank.
2. Move to a well ventilated area, outdoors, away from ames
and sparks.
3. Clean debris from area around the fuel cap.
4. Loosen fuel cap slowly. Prevent the cap from coming in
contact with dirt or debris.
5. Carefully add fuel without spilling.
6. Do not ll fuel tank completely full, allow space for fuel to
expand.
7. Immediately replace fuel cap and tighten. Wipe o spilled
fuel and allow to dry before starting engine.
CHECK ENGINE OIL
Make sure the engine oil is at the upper level of the oil ll hole.
Add oil as necessary.
To add/check the engine oil:
1. Be sure the generator is located on a level surface before
checking or relling the oil.
2. Remove the side panel on the engine recoil side of the
generator. Four screws must be removed, one from each
corner of the side panel.
NOTE:
Included in the box is a Phillips head screwdriver.
3. Clean around oil ll area.
4. Remove the oil fill cap and check the engine oil level.
SEE FIGURE 3
5. If oil level is below the lower level line, rell with 10W-30 (SJ,
SL or better) oil to upper level line (capacity 11.8 ounces).
SEE FIGURE 3
NOTE:
Change oil if contaminated.
GROUND GENERATOR
Make sure to properly ground the generator. The generator
must be on a rm, level surface with at least ve feet of clear-
ance on all sides.
CAUTION
ENGINE IS SHIPPED FROM FACTORY WITHOUT OIL. YOU
MUST ADD ENGINE OIL BEFORE STARTING ENGINE.
IF ENGINE IS STARTED WITHOUT OIL, ENGINE MAY BE
DAMAGED BEYOND REPAIR AND WILL NOT BE COVERED
BY WARRANTY.
NEVER STORE ENGINEWITH FUEL INTHETANK INDOORS.
FUEL AND FUEL VAPORS ARE HIGHLY FLAMMABLE.
AN ADULT ONLY MUST ALWAYS HANDLE AND FILL
THE ENGINE WITH FUEL.
ALWAYS HANDLE FUEL IN A WELL VENTILATED AREA,
OUTDOORS, AWAY FROM FLAMES OR SPARKS.
DO NOT START ENGINE IF FUEL IS SPILLED. WIPE OFF
EXCESS FUEL AND ALLOW TO DRY. REMOVE ENGINE
FROM AREA TO AVOID SPARKS.
IMPORTANT
DO NOT SPRAY WATER ON OR NEAR THE ELECTRON
ICS OF THE GENERATOR ASTHIS MAY RESULT IN DAM
AGE TO THE ELECTRICAL COMPONENTS.
WARNING
DO NOT REFILL TANK WHILE ENGINE IS RUNNING OR
HOT. ALWAYS CLOSE FUELVALVE BEFORE REFUELING.
BE CAREFUL NOT TO ADMIT DUST, DIRT, WATER OR
OTHER FOREIGN OBJECTS INTO FUEL.
DO NOT FILL ABOVE THE TOP OF THE FUEL STRAINER
OR IT MAY OVERFLOW WHEN THE FUEL EXPANDS.
KEEP OPEN FLAMES AWAY.
FIGURE 3
Remove Side Panel

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 13
RUN CHOKE
primer bulb
OPERATION
STARTING GENERATOR
Before starting make sure nothing is connected to the genera-
tor and it is in a stable position. The economy control switch
should be in the OFF position until the generator and the later
connected devices are running smoothly.
1. Turn the fuel tank cap air vent to the OPEN position.
SEE FIGURE 4
2. Turn the fuel valve to the ON position. SEE FIGURE 4
3. Turn the engine switch to the ON position. SEE FIGURE 5
4. Press the primer bulb six times with the choke in the RUN
position. SEE FIGURE 6
NOTE:
Priming the engine should only be necessary for cold
starts and after refueling.
5. Move choke lever to the CHOKE position. SEE FIGURE 6
NOTE:
Not necessary if the engine is warm.
6. Use one hand to securely hold the carrying handle of the
generator. With the other hand pull the starter handle slowly
until resistance is felt (this is the“compression”point). Return
the handle to its original position and then pull swiftly. Do no
fully extend the rope. After starting, slowly return the starter
handle to its original position.
NOTE:
If the engine does not start prime again and repeat.
7. Allow the engine to warm up.
8. Move choke lever back to the RUN position. SEE FIGURE 6
9. Allow for the engine to run without a load for a few minutes.
NOTE: For cold weather operation, store the unit in a cool
environment. Transferring the unit from a cold to a warm
place can cause the build up of harmful condensation.
TO STOP THE GENERATOR
1. Disconnect any electrical devices.
2. Flip the engine switch to the STOP position. SEE FIGURE 5
3. Turn the fuel valve to the OFF position. SEE FIGURE 4
4. Turn the fuel tank cap air vent counterclockwise to the
CLOSED position. SEE FIGURE 4
CAUTION
IF ENGINE FAILSTO START AFTER FOLLOWING START
ING PROCEDURES, PLEASE CONTACT OUR CUSTOMER
SERVICE DEPARTMENT AT 8003456007.
STARTER ROPE CAN CAUSE AN UNANTICIPATED JERK
TOWARDS ENGINE. PLEASE FOLLOW INSTRUCTIONS
TO AVOID INJURY.
NEVER LEAVE ENGINE RUNNING WHILE UNATTEND
ED. TURN OFF AFTER EVERY USE.
NEVER CARRY GENERATOR FROM ONE LOCATION TO
ANOTHER WHILE ENGINE IS RUNNING.
ALWAYS WEAR A PROTECTIVE HEARING DEVICE.
DO NOT START ENGINE IF FUEL IS SPILLED. WIPE OFF
EXCESS FUEL AND ALLOW TO DRY.
STARTING THE GENERATOR WITH ELECTRICAL DE
VICES CONNECTED COULD DAMAGETHE GENERATOR
AND THE CONNECTED DEVICES.
WARNING
MAKE SURE THE UNIT IS IN A STABLE POSITION BE
FORE PULLING THE STARTER HANDLE.
FIGURE 6
FIGURE 5
ENGINE SWITCHECON. SWITCH DC PROTECTOR
ON OFF
CLOSE
OPEN
CLOSEOPEN
ONOFF
FIGURE 4

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-514
USING ELECTRICAL POWER
AC Application:
1. Turn off the switch(es) of the electrical device(s) before
connecting to the generator.
2. Insert the plug(s) of the electrical device(s) into the receptacle.
3. Start electrical device(s). Let run for a few moments and then
ip the economy control switch to the ON position.
Overload Indicator Light:
The overload indicator light comes on when an overload of
a connected electrical device is detected, the inverter unit
overheats or the AC output voltage rises.The electronic breaker
will then activate, stopping power to the generator in order to
protect the generator and any connected electric devices. The
output light (green) will icker and the overload indicator light
(red) will turn on, then the engine will stop running. If so please
follow the following steps:
1. Turn o any connected electric devices.
2. Reduce the total wattage of connected electric devices to be
within the generators range.
3. If total wattage is within range, check for blockages in the
cooling air inlet and around the control unit. If any blockages
are found, remove.
4. Restart engine. Make sure to follow starting instructions.
DC Application (Option):
This usage is applicable to 12V battery charging only. Be sure that
the economy control switch is in the o position while charging
the battery.
1. Connect the battery charging cable to DC receptacle on the
generator.
NOTE:
A battery charging cable is included in the box.
2. Connect to the battery terminals using the charging leads.
Make sure the red lead is going to the positive (+) post of the
battery and the black lead is going to the negative (-) post of
the battery.
3. Once the connection is conrmed make sure the DC circuit
protector is in the ON position.
CAUTION
BE SURETHE ELECTRICAL DEVICES ISARETURNED OFF
BEFORE PLUGGING IN.
BE SURE THAT THE TOTAL LOAD IS WITHIN GENERATOR
RATED OUTPUT.
BE SURE THE SOCKET LOAD CURRENT IS WITHIN THE
SOCKET RATED CURRENT.
THE ECONOMY CONTROL SWITCH MUST BE TURNED TO
THE OFF POSITIONWHEN USING ELECTRIC DEVICES THAT
REQUIRE A LARGE STARTING CURRENT.
CAUTION
THE AC OUTPUT OF THE GENERATOR AUTOMATICALLY
RESETS WHEN THE ENGINE IS STOPPED AND THEN
RESTARTED.
THE OVERLOAD INDICATOR LIGHT MAY COME ON FOR A
FEW SECONDS AT FIRST WHEN USING ELECTRIC DEVICES
THAT REQUIRE A LARGE STARTING CURRENT.
BE SURE THE ECONOMY CONTROL SWITCH IS INTHE OFF
POSITION WHILE CHARGING BATTERIES WITH THE DC
APPLICATION.
WARNING
DO NOT USE WORN, BARE, FRAYED OR OTHERWISE
DAMAGEDELECTRICALCORDSETSWITHTHEGENERATOR.
DO NOT HANDLE ANYKIND OFELECTRICAL DEVICEWHILE
STANDING IN WATER,WHILE BAREFOOT ORWHILE HANDS
OR FEET ARE WET.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 15
MAINTENANCE
GENERATOR MAINTENANCE
Please read the maintenance schedule and observe these recommendations to extend the life of your generator.
Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you
properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple
maintenance procedures using basic hand tools. Other service tasks that are more dicult, or require special tools, are best handled
by professionals and are normally performed by a technician or other qualied mechanic.
Maintenance, replacement or repair of the emissions control devices and systems may be performed by any non-road engine
repair establishment or individuals. However, items must be serviced by an authorized dealer to obtain“no charge”emissions
control service.
The maintenance schedule applies to normal operating conditions. If you operate your engine under unusual conditions, such as sustained
high-load or high-temperature operation, or use in unusually wet or dusty conditions, consult your servicing dealer for recommendations
applicable to your individual needs and use.
MAINTENANCE SCHEDULE
Maintenance Item Remarks Pre-operation
check (daily)
Initial
month
or 20 hrs
Every 3
months
or 50 hrs
Every 6
months
or 100 hrs
Every 12
months
or 300 hrs
Spark Plug -
Type: CMR6A (TORCH)
Gap: 0.6 - 0.7 mm
Check condition, adjust gap and
clean. Replace if necessary.
X
Engine Oil Check oil level. X
Replace. X X
Air Filter Clean. Replace if necessary. X
Fuel Strainer Clean fuel strainer.
Replace if necessary.
X
Choke Check choke operation. X
Valve Clearance -
Intake: 0.15mm (0.006”)
Exhaust: 0.20mm (0.008”)
Check and adjust when
engine is cold.
X
Fuel / Oil Lines Check hoses for crack or damage.
Replace if necessary.
X
Exhaust System Check for leakage.
Retighten if necessary.
X
Check muer screen.
Clean/replace if necessary
X
Starting System Check recoil starter operation. X
Screws / Fasteners Check that all hardware is secure.
Correct if necessary.
X
Generator Check the output light comes on. X

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-516
IMPORTANT
NEVER TWIST AIR FILTERS WHEN CLEANING. ALWAYS PRESS.
CAUTION
ENGINE MUST BE TURNED OFF AND COOL BEFORE
CHECKING AND ADJUSTING ENGINE OR EQUIPMENT.
TEMPERATURE OF MUFFLER AND NEARBY AREAS
MAY EXCEED 150° F 65° C. AVOID THESE AREAS.
NEVER STORE ENGINEWITH FUEL INTHE TANK INSIDE
A BUILDING. POTENTIAL SPARKS MAY BE PRESENT
FOR IGNITION OF FUEL AND FUEL VAPORS.
AN ADULT ONLY MUST DO MAINTENANCE AND
REPAIR ON GENERATOR.
ENGINE MUST BE TURNED OFF AND COOL BEFORE
ANY REPAIR OR MAINTENANCE CAN BE DONE.
DO NOT OVER FILL THE ENGINE CRANKCASE WITH
OIL. HIGH OIL PRESSURE MAY RESULT, CAUSING
PREMATURE ENGINE WEAR AND DAMAGE.
STEPS FOR WORKING ON EQUIPMENT
1. Flip the engine switch to the STOP position.
2. Replace or repair the part on the IG800W.
3. Check all parts that were repaired, or removed during repair,
that they are secure and t correctly.
NOTE: Only use approved Earthquake spare. Never replace
parts that are not specically designed for the generator.
OIL MAINTENANCE
After the rst twenty hours of operating a new Viper engine
the oil should be replaced, and every 100 hours of operating
time thereafter. The oil should be changed every 50 hours if
used under severe conditions, such as in high temperatures or
under heavy loads. Check oil periodically; do not overll!
ENGINE OIL REPLACEMENT
1. Place the machine on a level surface and warm up the en-
gine for several minutes. Then stop the engine and turn the
fuel valve to the OFF position and the fuel tank cap air vent
to the CLOSED position.
2. Remove the side panel on the starter handle side of the gen-
erator by loosening the four screws holding it in place.
3. Remove the oil ll cap.
4. Place an oil pan under the engine. Tilt the generator to drain
the oil completely. Once oil has been removed return the
generator to the level surface.
5. Add engine oil, 10W-30 (API Service SJ, SL or better). Fill to
the upper level. For extreme high and low temperature con-
ditions refer to SAE chart. SEE FIGURE 7
6. Install the oil ll cap back in place.
7. Reconnect the side panel to the generator and tighten down
the four screws.
CAUTION
BE SURE NO FOREIGN MATERIAL ENTERS THE
CRANKCASE WHEN ADDING OR CHANGING OIL.
DO NOT TILT GENERATOR WHEN ADDING OIL. THIS
COULD RESULT IN OVERFILLING AND DAMAGE.
THE ENGINE SHOULD NEVER RUN WITHOUT THE AIR
FILTER; EXCESSIVE PISTON AND/OR CYLINDER WEAR
MAY RESULT.
CAUTION
TO AVOID INJURY OR DEATH, NEVER SIPHON FUEL BY
MOUTH.
NEVER STORE GENERATOR WITH FUEL IN THE FUEL
TANK INSIDE AN ENCLOSED AREA OR BUILDING.
10W-40
10W-30
5W-30
-20 0 20 40 60 80 100 °F
-30 -20 -10 0 10 20 30 40 °C
Environment Temperature
SAE
FIGURE 7

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 17
AIR FILTER
Maintaining an air lter cleaner in proper condition is very im-
portant. Dirt induced through improperly installed, improperly
serviced or inadequate lters damages and wears out engines.
Keep the lter clean.
Cleaning / Replacing Air Filter:
1. Remove the side panel on the starter handle side of the gen-
erator by loosening the four screws holding it in place.
SEE FIGURE 8
2. Remove the air lter cover by loosening the one screw hold-
ing it in place and then remove the air lter.
3. Replace with a new oiled lter, or wash the current lter with
warm water and mild soap. Remember to thoroughly oil the
foam lter with 30 or 40 weight motor oil and squeeze out
any excess oil before reinstalling it.
NOTE: Make sure to press the lter evenly into place to en-
sure that the foam is fully seated into its sealed position.
4. Reconnect the air lter cover and secure it with the screw.
5. Reconnect the side panel, securing with the four screws.
FUEL TANK STRAINER
Cleaning / Replacing:
1. Remove the fuel tank cap and strainer. SEE FIGURE 9
2. Clean the strainer with solvent. If damaged, replace.
3. Wipe the strainer and reinsert it.
NOTE: Make sure the tank cap is tightened securely.
SPARK ARRESTER
Cleaning / Replacing:
1. Remove the muer shroud. SEE FIGURE 10
2. Remove muer clamp using a athead screwdriver to re-
move the spark arrester.
4. Remove the carbon deposits on the spark arrester using a
wire brush. If damaged, replace.
5. Reinstall the spark arrester.
6. Reinstall the muer shroud.
SPARK PLUG
The recommended spark plug is a CMR6A (TORCH). For
maintenance and care of the spark plug go online to www.
getearthquake.com for instructions or call Earthquake
customer service.
CARBURETOR
Never tamper with factory setting of the carburetor.
WARNING
ALWAYS BE SURE THE TANK CAP IS TIGHTENED SE
CURELY TO PREVENT FUEL SPILLS.
THE ENGINE AND MUFFLER WILL BE VERY HOT AFTER
THE ENGINE HAS BEEN RUNNING. ALLOW ENGINE TO
COOL BEFORE CLEANING/REPLACING PARTS.
AVOID TOUCHING THE ENGINE OR MUFFLER WHILE
THEY ARE STILL HOT WITH ANY PART OF YOUR BODY
OR CLOTHING DURING INSPECTION OR REPAIR.
air lter cover
side panel air lter
FIGURE 8
muer
clamp
spark
arrester
muer
shroud
FIGURE 10
fuel tank strainer
fuel tank cap
FIGURE 9

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-518
TROUBLESHOOTING & REPAIR
At Earthquake, we build quality and durability into the design
of our products; but no amount of careful design by us, and
careful maintenance by you, can guarantee a repair-free life for
your Earthquake cultivator. Most repairs will be minor, and easily
xed by following the suggestions in the troubleshooting guide
in this section.
The guide will help you pinpoint the causes of common problems
and identify remedies.
For more complicated repairs, you may want to rely on your
retailer, an authorized service center or Earthquake customer
service. Earthquake will make the necessary repairs if a service
center is not available. A parts breakdown is located toward the
end of this manual.
We will always be glad to answer any questions you have, or
help you nd suitable assistance.To order parts or inquire about
warranty, call or e-mail us using the contact information found
in this section.
ORDERING REPLACEMENT PARTS
To order replacement parts visit www.getearthquake.com or call
Earthquake customer service at 1-800-345-6007.
For other general questions, you can e-mail us at
Please include the following information with your order:
1) Part numbers
2) Part description
3) Quantity
4) Model number and serial number
SPARE PARTS
Only use approved Earthquake spares.
TRANSPORT & STORAGE
TRANSPORTING YOUR GENERATOR
1. After using the generator, and before transporting it in a truck
bed, check that the fuel cap is screwed on (clockwise) tightly,
that the fuel cap vent is closed and that the fuel valve is o.
Never transport inside an enclosed space within a vehicle.
Fuel or fuel vapors may ignite causing serious injury or death.
2. If fuel is present in the fuel tank, transport in an open vehicle
in an upright position.
3. If an enclosed vehicle must be used, allow generator to cool
completely and then remove fuel into an approved red fuel
container. DO NOT siphon by mouth.
4. Wipe away any spilled fuel and allow to dry.
5. Run engine to use up the fuel in the carburetor and fuel tank.
Always run engine in a well ventilated area.
6. Fuel cap should be screwed down tightly, fuel cap vent closed
and fuel valve o before transporting your generator in a
vehicle.
LONGTERM STORAGE
It is important to prevent gum deposits from forming in essen-
tial fuel system parts such as the carburetor, fuel hose or tank
during long-term storage. It is recommended to use a mini-
mum 87 octane gasoline with NO ethanol content due to indi-
cation that blended fuels can attract moisture and damage the
an engine during storage. If your generator will not be used for
more than one month, prepare it for long-term storage.
Steps for Long-Term Storage
1. Allow generator to cool completely and then remove all of
the fuel from the fuel tank into an approved fuel container.
Discard appropriately.
2. Start and run engine to use up the fuel in the carburetor and
fuel tank. Be sure to close the fuel valve once complete.
3. After the engine cools down, drain oil from crankcase. Rell
with recommended grade.
4. Remove spark plug. Pour about 1/2 ounce (15 ml) of engine
oil into the cylinder (the spark plug location). Cover spark plug
hole with rag. Pull the starting rope several times to coat the
cylinder wall with engine oil.
5. Install and tighten the spark plug.
6. Clean the generator outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
7. Store the unit in a clean, dry place.
NOTE: Do not store gasoline from one season to another. If
possible, store the unit indoors and cover it to give protec-
tion from dust and dirt.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5 19
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE REMEDY/ACTION
Engine will not start 1. Engine switch in STOP position 1. Flip engine switch to ON position
2. Out of fuel 2. Refuel
3. Fuel valve in OFF position 3. Turn fuel valve to ON position
4. Spark plug wire disconnected 4. Connect spark plug wire to spark plug
5. Spark plug wet, faulty or improperly gapped 5. Clean, replace or gap spark plug
6. Economy switch in ON position 6. Flip economy switch to the OFF position; Once
generator is running ip to the ON position
7. Fuel tank cap air vent in CLOSED position 7. Turn to OPEN position
Engine starts, then
runs rough
1. Dirty air lter 1. Clean or replace air lter
2. Choke partially engaged 2. Turn o choke
3. Defective or dirty spark plug 3. Clean or replace spark plug
4. Economy switch is defective 4. Replace economy switch
5. Carburetor out of adjustment 5. Call Earthquake Customer Service
Engine is hard to start 1. Stale fuel 1. Drain old fuel and replace with fresh. Use fuel
stabilizer at end of season
2. Spark plug wire loose 2. Make sure spark wire is securely attached to spark
plug
3. Dirty carburetor 3. Clean carburetor, use fuel stabilizer, new fuel can
Engine misses or lacks
power
1. Clogged fuel tank 1. Remove and clean fuel tank
2. Clogged air lter 2. Clean or replace air lter
3. Carburetor out of adjustment or bad 3. Call Earthquake Customer Service
4. Spark plug wet, faulty or improperly gapped 4. Clean, replace or gap spark plug
Engine runs, then
quits
1. Fuel tank cap air vent in CLOSED position 1. Turn to OPEN position
2. Low fuel level 2. Add fuel to tank
3. Incorrect engine oil level 3. Check engine oil level, add or drain as needed
4. Contaminated fuel 4. Remove and replace contaminated fuel; Clean or
replace fuel strainer
5. Defective low oil level switch 5. Replace low oil level switch
6. Defective ignition coil 6. Replace ignition coil
Engine revs too high 1. Carburetor out of adjustment 1. Call Earthquake Customer Service
Engine speed increases and decreases, this is normal as the generator starts up and as loads vary.
Contact Earthquake customer service at 800-345-6007 if additional assistance is needed.

Operator’s Manual
800 Watt Inverter Generator
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-520
ELECTRICAL WIRE DIAGRAM
Other manuals for IG800W
1
Table of contents
Languages:
Other EarthQuake Portable Generator manuals