Easy wave RCP24 User manual

Models
RCP24E5001A01
Technical Details
Frequency: 868.30 MHz
Modulation: FSK
Coding: Easywave
Range: up to 150 m under
favourableopeneld
conditions
Power supply: 230 VAC 50 Hz
Power consumption: 0.2 W Standby
1.1 W (at max. load)
Current consumption: 2 mA Standby
Operating temperature: -20 °C to +35 °C
Transport and storage
temperature: -20 °C to +75 °C
Max. relative air humidity: 75%
Volume at a distance
of 30 cm: low: 80 dB(A)
medium: 85 dB(A)
high: 90 dB(A)
Dimensions (H/W/D): 71.4/71.4/40 mm
without plug
71.4/71.4/75.5 mm
with plug
Weight: 115 g
Scope of Delivery
Plug-in radio bell RCP24, operating instructions
Intended Use
The device may only be operated indoors and
only as a radio bell.
The manufacturer will not be liable for damage
caused by improper or inappropriate use.
Safety Advice
Please read these instructions carefully
before using the device!
- We do not accept any liability for personal
injury or damage to property caused by
incorrect handling or non-observance of the
safety instructions!
- Do not open the appliance‘s casing!
- Have malfunctioning devices checked by the
manufacturers!
- Do not make any unauthorized alterations or
modicationstotheunit!
RCP24 Plug-In Radio Bell
EN
Function
The Plug-In Radio Bell RCP24 receives Easy-
wave transmission codes from programmed
transmitters. Once the transmission button is
pressed, a melody will sound and/or a light will
begin to ash.A total of 32 transmission codes
can be programmed into the unit.
12 multichannel melodies are available to choose
from as ringtones. The melodies can be played at
three volume levels (approximately 80 dB, 85 dB,
and 90 dB). If the radio bell is muted (0 dB), re-
cognized Easywave telegrams are signalled only
bytheashinglight.
An incoming call can also be ended early
by pressing one of the two buttons on the
device.
Start Up
1. Plug the radio bell into an electrically and
structurally intact protective contact socket;
an acknowledgement tone will sound and a
lightwillbrieyash.
2. Transfer the transmitter coding to the radio
bell (see section titled “Programming the
transmitter”).
Make sure that there is no interference with
the wireless connection. Do not mount the
device in a distribution box, metal casings
or in direct proximity to large metal objects.
Battery level monitoring
Some Easywave transmitters include battery mo-
nitoring. The RCP24 can evaluate low-battery vol-
tage telegrams issued by these transmitters.
The relevant operating instructions will tell you
whether a transmitter supports this function.
Acknowledging Low Battery Voltage
If a low battery voltage message is received from
a programmed transmitter, the PLED and LED
willashredalternatelyandtherewillbea
double beep after the ringtone sounds.
If a telegram without a low battery voltage mes-
sage is subsequently received from the same
transmitter, this signalling stops. (Battery has ap-
parently been changed.).
If low battery voltage telegrams have been re-
ceived from several transmitters, all transmitters
must send a telegram without a low battery vol-
tage message for the signalling to automatically
end.
To manually acknowledge the low battery voltage
message, briey press the Pbutton or the but-
ton .
Button | LED
Volume/Ringtone duration
Button P | LED P
Programming
Speaker
Flashing light
Flashing
light
Programming
You activate the programming mode of the
RCP24 by briey pressing the Pbutton multiple
times.
Each press moves the selection forward by one
melody, and there are twelve melodies available
in total. When you hear your preferred melody,
press the transmitter button you wish to program
within 30 seconds to complete the programming
process.
Select melody
Button P press once briey (< 1.6 s)
→MELODY 1 is selected
→LEDPashesred,Melody1isplayed
Button P press twice briey (< 1.6 s)
→MELODY 2 is selected
→LEDPashesred,Melody2isplayed
Button P press three times briey (< 1.6 s)
→MELODY 3 is selected
→LEDPashesred,Melody3isplayed
etc.
Button P press twelve times briey (< 1.6 s)
→MELODY 12 is selected
→LEDPashesred,Melody12isplayed
Programming transmission code
Press the button on your transmitter. The me-
lody is assigned to the transmission code and
saved in the RCP24. The LEDPlights up red
for 2 seconds.
The RCP24 then switches to operating mode
and the LED Pswitcheso.
The programming process will be automati-
cally cancelled if no buttons are pressed for
30 seconds. To manually cancel program-
ming, press the Pbuttonbrieyrepeated-
lyuntilitisnolongerashingorpressthe
button once.
Programming the Transmitter
Select the melody
Button P
Pressthebuttonbriey
repeatedly (< 1.6 s)
until the desired
melody is played
Programming the
transmission code
Press the transmit-
ter button
or
Connect voltage
(RTS17)
Transmit transmission code
Change Melody
If you would like to change the melody of a pro-
grammed transmitter, simply re-program the
transmitter into the RCP24, and choose your pre-
ferred melody.
The previous selection will be overwritten.
→

Adjust Volume
To adjust the volume of the RCP24, repeatedly
press the button , while the RCP24 is in ope-
rating mode.
Thersttimeitispressed,themostrecentlyused
melody will be played at the currently set volume.
Press the button again while the melody is still
being played to move forward by one volume set-
ting:
Select volume
Button press once briey (< 1.6 s)
→ACTUAL volume is selected
Button press twice briey (< 1.6 s)
→NEXT volume is selected
Button press three times briey (< 1.6 s)
→OVER NEXT volume is selected
etc.
The most recently played setting will be applied.
This volume applies for all programmed transmit-
ters.
The following volumes and volume with ashing
light combinations are available:
Volume1: 80dBwithashinglight
(factory setting)
Volume2: 85dBwithashinglight
Volume3: 90dBwithashinglight
Volume4: onlyashlight,withoutmelody
(LED lights up red
continuously)
Volume5: 80dBwithoutashinglight
Volume6: 85dBwithoutashinglight
Volume7: 90dBwithoutashinglight
Disposal
Old devices must not be disposed of with
household waste!
Dispose of the waste product at a desig-
nated collection point for electronic waste
or via your specialist retailer.
Dispose of the packaging material in the
recycling containers for cardboard, paper
and plastics.
UMUM181316B_1123 EN
PROGRAMMING
GENERAL INFORMATION
Button
pressbrieyrepeatedly(<1.6s)
until the desired volume is played.
Long press
Button P
(>1.6 s)
Long press
Button P
(>1.6 s)
The decibel gures are only
guidelines, the actual volume
depends on the melody selec-
ted.
Long press
Button P
(>1.6 s)
Brieypress
Button P
(<1.6 s)
Press
Transmitter
button
Long press
Button P
(>1.6 s)
Warranty
During the warranty period, we undertake to rec-
tify free of charge by repair or replacement any
product defects arising from production or mate-
rial faults. Any unauthorised tampering with, or
modicationsto,theproductshallrenderthiswar-
ranty null and void.
Conformity
ELDAT EaS GmbH hereby declares that the radio
equipment type RCP24 is in compliance with Di-
rective 2014/53/EU and UK S.I. 2017/1206.
The full text of the EU and UK declarations of con-
formity can be obtained at the following internet
address: www.eldat.de
Customer Service
If the device does not work properly despite pro-
per handling or in case of damage, please
contact the manufacturer or your retailer.
ELDAT EaS GmbH
Schmiedestraße 2
15745 Wildau
Germany
Phone: +49 3375 9037-310
Internet: www.eldat.de
E-mail: [email protected]
Delete all transmission codes (Reset)
All programmed transmitters are deleted and the
factory settings are restored:
Button P long press (> 1.6 s)
→ Deletemodeactive;LEDPashesred
quickly
Button P long press (> 1.6 s)
→ Reset is carried out; LED P lights up red
for 4 seconds. The RCP24 switches to
operating mode and the LED P switches
o.
Set the ringtone duration
The ringtone duration can be set in the range from
approx. 1 second to 60 seconds. By default, the
ringing tone lasts approx. 4 seconds (depending
on the selected melody).
Start setting the ringtone duration
Button press once long (> 1,6 s)
→ LEDPand LED light up.
Start time measurement
Button press once briey (< 1,6 s)
→ LED ashesslowly
→ LED Pswitcheso
Wait for the desired ringtone duration
(max. 60 seconds).
The last used melody is played at the lowest
volume and the playing time is measured.
When the maximum ringing tone duration
of 60 seconds is reached, the LED a-
shes quickly and the melody stops.
Stopping time measurement
Button press once briey (< 1,6 s)
→ThePandLEDslightupfor2secondsand
the RCP24 switches to operational readi-
ness. The measured time (playback time)
is applied as the new ringtone duration.
The measurement of the ringtone duration stops
automatically after 4 minutes without making any
changes. You can also cancel the measurement
manually at any time by pressing the Pbutton.
The maximum ringtone duration is approx. 60
seconds. Measurements that go beyond this are
truncated to this value.
Melodies that have been started are al-
ways played to the end, so that there may
beslightdierencesin the duration of the
ringing tone depending on the melody se-
lected.
The ringtone duration applies to all pro-
grammed transmitters.
Delete Transmission Code
In this mode, individual transmitters can be speci-
callydeletedfromtheRCP24‘smemory.
Button P long press (> 1.6 s)
→ Deletemodeactive;LED Pashesred
quickly
Press the button on your transmitter
→Transmissioncodedeleted;LED P lights up
red for 2 seconds. The RCP24 then swit-
ches to operating mode delete extra space
and the LED Pturnso.
The deletion process will be automatically can-
celled if no buttons are pressed for 30 seconds. To
manually cancel the process, press the Pbutton
or buttonbriey.
Wait for the ring-
tone duration
Brieypress
Button P (<1.6 s)
The measured ringto-
ne duration is saved
This manual suits for next models