ecoey GS558D-H04 User manual

Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
1
-
EN14604:2005/AC:2008
Smoke Alarm User Manual
Model number: GS558D-H04 Ref ST558D
Thank you for purchasing our smoke alarm with wireless and
heat detection. Please take a few minutes to read the
manual thoroughly and familiarize yourself and your family
with its operation. And save it for future reference.
Product Specifications:
Power : DC2*1.5V Alkaline AA battery
Operation current : <6uA (standby), <1200mA (alarm)
Alarm volume : >85dB(A) at 3 meters.
Smoke sensitivity : 0.108-0.141dB/m
Heat sensitivity: 54-70
Local smoke alarm sound pattern:
BI 0.5s - pause 0.5s BI 0.5s pause 0.5s BI 0.5s
pause 1.5s, with the red LED flash, repeat this alarm
pattern.
Local heat alarm sound pattern:
BI 0.2s - pause 0.1s, with the red LED flash, repeat this
alarm pattern.
Description:
The unit is a photoelectric 3V DC smoke alarm. It is operated
by 3v AA Alkaline battery. With the photoelectric technology,
it is more sensitive to detecting slow smolder fires which
general thick, black smoke, little heat and may smolder for
hours before bursting into flames. The smoke alarm do not
contain the radioactive material which is harmless to the
environment.
The smoke alarm should be installed in every room (except the
bathroom), and every other area of the home, making sure the
people in the home will be able to hear and respond to the
alarm sound. For minimum protection you should fit an alarm
in the hallway between the living areas and sleeping areas.
Place the unit near to the living areas as possible and ensure
the alarm is audible when the bedrooms are occupied.
Typical single storey dwelling with recommended:
Install a smoke alarm on the ceiling inside each bedroom and
in the hallway outside each separate sleeping area. If a
bedroom area hallway is more than 30 feet long, install a
smoke alarm at each end. If there is a basement: install a smoke
alarm on the basement ceiling at the bottom of the stairwell.
Typical multi-storey dwelling with recommended protection.
Install a smoke alarm on the ceiling inside each bedroom and
in the hallway outside each separate sleeping area. If a
bedroom area hallway is more than 30 feet long, install a
smoke alarm at each end install a smoke alarm at the top of a
first to- second floor stairwell.
Important Safety Information:
1: The test button accurately tests smoke alarm functions. Do
not use any other test method. Test smoke alarm weekly to
ensure proper operation.
2: Do not remove or disconnect battery. This will take out your
protection. Open windows or fan the air around smoke
alarm for silence it.
3: Observe and follow all local and national electrical and
building codes for installation.
4: This smoke alarm is designed to be used inside a single
family only. In multifamily buildings, each individual
living unit should have its own smoke alarms. Do not
install in non-residential buildings. And this smoke alarm
is not a substitute for a complete alarm system.
5: Install a smoke alarm in every room and on every level of
the home. Smoke may not reach the smoke alarm for many
reasons. For example, if a fire starts in a remote part of the
home, on another level, in a chimney, wall, roof, or on the
other side of a closed door, smoke may not reach the smoke
alarm in time to alert household members. A smoke alarm
will not promptly detect a fire except in the area or room
in which it is installed.
6: Smoke alarm may not alert every household member every
time. The alarm horn is loud in order to alert individuals to
a potential danger. However, there may be some
circumstances where a household member may not hear
the alarm (i.e. outdoor or indoor noise, sound sleepers,
drug or alcohol usage, the hard of hearing, etc.). If you
suspect that this smoke alarm may not alert a household
member, install and maintain specialty smoke alarms.

Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
2
-
and quickly respond to it to reduce the risk of damage,
injury, or death that may result from fire, If a household
member is hard of hearing, install special smoke alarms
with lights or vibrating devices to alert occupants.
7: Smoke alarms can only sound their alarms when they detect
smoke or detect combustion particles in the air. They do not
sense heat, flame, or gas. This smoke alarm is designed to
give audible warning of a developing fire. However, many
fires are fast - burning, explosive, or intentional, and others
are caused by carelessness or safety hazards. In this circs,
Smoke may not remake the unit alarm QUICKLY
ENOUGH to ensure safe escape.
8: Smoke alarms have limitations. This smoke alarm is not
foolproof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for insurance.
Homeowners and renters should insure their lives and
property. In addition, it is possible for the smoke alarm to
fail at any time. For this reason, you must test the smoke
alarm weekly and replace unit every 10 years.
Do Not Install Smoke Alarms in
the Following Places:
1: Near appliances or areas where normal combustion
Regularly occurs (kitchens, near furnaces, hot water
heaters). Use specialized smoke alarm with unwanted alarm
control for this areas.
2: In areas with high humidity, like bathrooms or areas near
dishwashers or washing machines. Install al least 10feet
away from these areas.
3: Near air returns or heating and cooling supply vents. Install
at least 3 feet away from these areas. The air could blow
smoke away from the detector, interrupting its alarm.
4: In rooms where temperatures may fall below 0 or rise
above 40 .
5: In extremely dusty, dirty, or insect infested areas influence
particles interfere with smoke alarm operation.
Battery Specification:
Rating voltage: DC 1.5V
Package: AA alkaline battery
Recommend battery:
Energize: E91; Gold Peak Group: GP 15A LR6; Raymax : LR6
Replace Battery:
1: Turn the alarm body counterclockwise and take out the
alarm body from the bracket.
2: Take out the old battery from the battery box.
3: Fix the two new batteries to the battery box. Please note the
battery polarity.
4: Fix the battery into battery box, fit alarm body on bracket
and turn the alarm body clockwise.
5: Test smoke alarm using test button. The sound pattern is 3
short beeps-1.5seconds pause, repeat it. I
sound output, it means that the smoke alarm is faulty or
the installing operation is wrong, and you should gain the
correctly method of disposal through reading
.
LED indicator
1: When the alarm is running normally, the red LED will
flash 1 time per 40 seconds.
2: When the battery failure or low battery is detected, the
1 time and with a corresponding red
LED flashing 1 time per 40 seconds.
3: When the unit is fault, it will chirp once per 40 seconds.
4: When the unit is running in the silence mode, the red LED
will flash once every 8 seconds.
Note: When the units chirp 1 time per 40 second, Press the test
button, it will be paused for this warning tone for 8
hours. It can still normally detect smoke during this
period, it only remove nuisance warning tone.
Alarm silence (silence mode)
During the unit is alarming, push the test button, it will be
paused the unit alarming for approx 10 minutes. The red
LED will flash once every 8 seconds, it indicates the smoke
alarm is running into the silence mode. Smoke alarms are
designed to minimize nuisance alarms. Combustion
particles from cooking may set off the alarm if the alarm is
located close to the cooking area. Large quantities of
combustible particles are generated from spills or when
grilling/frying. Using the fan on a range hood that vents to
outside (non-recirculating type) will also help remove these
combustible particles from the kitchen. The alarm silence
(test button) is extremely useful in a kitchen area or other
areas prone to nuisance alarms.
The silence feature is to be used only when a known alarm
condition, such as smoke from cooking activates the alarm.
The smoke alarm will automatically reset after
approximately 10 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
The alarm silencer (silence mode) can be repeatedly until
the air has been cleared of the condition causing the alarm.

Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
3
-
Testing the Smoke Alarm:
Test each smoke alarm to be sure it is installed correctly and
operating properly.
1: Do not use an open flame to test the alarm. You may ignite
and damage the alarm or your home.
2: Test the alarms weekly and upon return from vacation or
when no one has been at home for several days.
3: Stand at an unit when testing.
Test all smoke alarms weekly by doing the following step.
4: Firmly press the test button for at least 5 seconds. The alarm
will sound 3 short beeps 1.5 seconds pause, then repeat
it until release the button. The alarm may sound for up to
a few seconds after releasing the test button.
DANGER: If the alarm sounds, and it is not being tested, it
means the unit is sensing smoke, THE SOUND OF THE ALARM
REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
Wireless function description:
Wireless frequency: 2.4G Wifi
Wireless transmission current: < 450mA
Wireless distance: >30 meters
Add device (via APP)
a: Click on the top right corner of the app interface +
All Devices Other products Confirm indicator rapidly
blink Write WiFi password Confirm
b: Smoke devices is in standby, Press the button three times in
2 seconds When the smoke LED is turned on Connecting
to the network
c: When the display device in the APP is Adding device
succeeded Click Done Device added successfully
Note: repeat the same process with all the alarms you have
on hand.
Maintenance and Cleaning:
In addition to weekly testing, the alarm requires periodic
cleaning to remove dust, dirt, and debris.
Clean the alarm at least once a month to remove dust, dirt, or
debris.
Use a vacuum cleaner with the soft brush, vacuum all sides
and covers of smoke alarm. Be sure all the vents are free of
debris.
IMPORTANT: Do not attempt to remove the cover to clean
inside. This will affect warranty.
WARNING! Use only the batteries specified. Use different
batteries may have detrimental effects on the alarm. A
good safety measure is to replace the battery at least once
a year.
Note: Reinstall immediately after cleaning and then test
unit using the test button.
Repair:
Caution: Do not attempt to repair the alarm. It will affect your
warranty.
If the alarm is not operating properly, and is still under
warranty, return it to the original place you buy. Pack it in a
well-padded carton, and ship to the original place you buy.
If the alarm is no longer under warranty, have a licensed
electrician replace it immediately with a comparable alarm.
Practice Fire Safety:
If the alarm sounds, and you have not pushed the test button,
it is warning of a dangerous situation, your immediate
response is necessary. To prepare for such occurrences,
develop family escape plans, discuss them with all household
members, and practice them regularly.
1: Expose everyone to the sound of a smoke alarm and explain
what the sound means.
2: Determine two exits from each room and an escape route to
the outside from each exit.
3: Teach all household members to touch the door and use an
alternate exit when the door is hot, instruct them not to open
the door if the door is hot.
4: Teach household members to crawl along the floor to stay
below dangerous smoke, fumes and gases.
5: Determine a safe meeting place for all members outside the
building.
What to Do in Case of Fire:
1: Do not be panic; stay calm.
2: Leave the building as quickly as possible. Touch doors to
feel if they were hot before opening them. Use an alternate
exit if necessary. Crawl along the floor, and do stop to
collect anything.
3: Meet at a pre-arranged meeting place outside the building.
4: Call the fire department form outside the building.
5: Do not go back inside a burning building. Wait for the fire
department to arrive.
Note: These guidelines will assist you in the event of a fire,
however, to reduce the chance that fires will start, practice fire
safety rules and prevent hazardous situations.

Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
4
-
Trouble shooting:
DO NOT disconnect battery to quiet an unwanted alarm. This
will remove your protection. Fan the air or open a window to
remove smoke or dust.
Problem Method of disposal
Smoke alarm does
not
sound when tested.
1: Remove smoke
alarm from
bracket. then Check the
battery is properly connect
to battery connector.
2: Replace the unit.
Smoke alarm beeps
with the red LED flash
about once 40 seconds.
Replace battery
, please refer to
REPLACE BATTERY .
The alarm sounds
different from
it is used
to. It starts and stops.
1: This
alarm is operating
correctly.
2: Clean smoke alarm.
Please
refer to the
maintenance and
cleaning section.
Warranty Information:
Company warrants to the original consumer.
Purchase each new smoke alarm to be free from defects in
material and workmanship under normal use and service for a
period of 3 years from the date of purchase. This warranty does
not cover damage resulting from accident, misuse or abuse or
lack of reasonable care of the product.
In no case shall company be liable for any incidental or
consequential damages for breach of this or any other warranty
express or implied, whatsoever. The bad product can be mailed
to the following address with a detail explanation of problem.
Before you install the alarm, please read the instruction.
Where is the best to be Installed:
At first you need install one unit in the bedroom and route
way, if you have several bedrooms
alarm in every room.
Install it in the stairway and in every floor.
Smoke, heat and burning things will spread horizontally
after rising to the ceiling, so install the alarm on middle of
the ceiling of ordinary structure house .let the alarm induce
every corner.
ceiling
for some reasons, the distance which the alarm away form
the wall corner should be beyond 50cm. (see the diagram 1).
If the length of the room or the hall is beyond 30 foot, you
need install several alarms in the hall.
When the ceiling is slanting, the alarm needs to be installed
500mm away from the highest ceiling point in the room (see
the diagram 2).
Diagram 1
Diagram 2
Installation:
Fix the two AA batteries to each battery box of the smoke
alarm.
According to the Wireless function description
Section to operate the smoke alarm. Ensure the wireless
function is ok.
Then press the bracket on the installation position, mark
installation hole of bracket with pencil.
Bore two installation hole on the sign with electric drill.
Make diameter of holes is 5mm, Strike the two plastic
plugs into holes with hammer.
Attach the bracket to the plastic plugs and fix tightly the

Document NO.: RD-(558D-H04)-39-001 Version: A
Date: 2018.12.17
-
5
-
screws (3*25mm) into the plastic plugs. (refer to Diagram
3).
Fit the alarm on the bracket and turn the alarm body
clockwise, until matching well on the bracket.
Test smoke alarm using test button. The alarm will sound 3
short beeps 1.5 seconds pause, then repeat it until release
the button.
if no sound, it indicates a defective alarm, you can refer to
urn to your retailer
during warranty.
If you have any questions on installation, you can contact
your retailer.
During testing, may the other smoke detector will alarm. Once
release the button, others will stop alarming in 1 minute. In
such a way, you can check the wireless function.
WARNING:
To prevent injury, this unit must be securely attached to the
ceiling in accordance with the installation instructions.
Manufacturer:
SITERWELL ELECTRONICS Co., Limited
ADDRESS:
No.666 Qingfeng Road, Jiangbei District, Ningbo,
Zhejiang Province, China
TEL: 0086-574-87729581
FAX: 0086-574-87729581
E-Mail: sales@china-siter.com
Holes of ceiling
screws
B
racket
Plastic plugs
Alarm body
Diagram 3
This manual suits for next models
1
Table of contents
Other ecoey Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

Universal Security Instruments
Universal Security Instruments 2975CN instructions

teko
teko Astra-Z-4245 Operation manual

Mini Gadgets
Mini Gadgets BBSSmoke user manual

Kidde
Kidde WFPCO user manual

Dräger
Dräger Polytron Pulsar 2 Technical manual

Honeywell Home
Honeywell Home R200S-N1 Installation and user guide