If the unit is improperly installed, it may cause a breakdown or an accident. Do not
install in the following areas:
1) A place of frequent vibration or where vibration easily occurs. (Installation has to be a
sound place where there is no vibration.)
2) A place where the surrounding temperature exceeds 122°F or below 14°F.
3) A place where the temperature is freezing like a freezer.
4) A place where the is corrosive gas or use of chemical products.
5) A place where there is explosive dust or gas where it may occur.
6) A place where there is signicant dust.
7) A place where there is signicant humidity such as bathrooms, kitchens or other
rooms that have over 90% of humidity or where it may occur.
Make sure to disconnect the power in the e vent of a power outage. When power supply
is restored, the impeller may rotate rapidly causing an accident.
In using your fan, you should follow the IMPORTANT INSTRUCTIONS listed below. As
part of these instructions we have used the word WARNING which indicates a hazard
that, if not avoided, could result in death or injury.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety precautions should always be followed to
reduce the risk of re, electrical shock, and injury to persons, including the following:
Read all instructions before using this product.
• Use this fan only as described in this manual. Any other use not recommended by the
manufacturer may cause re, electrical shock, or injury to persons.
• Extreme caution is necessary when the fan is used by or near children.
• Do not sit or stand on fan. Do not place objects on fan.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as
this may cause electric shock, and/or a re hazard.
• A fan has arcing parts inside. Do not use it in areas where gasoline, paint or ammable
materials are used or stored.
• Do not operate any fan with a damaged cord or plug. Do not operate the fan, which
has been dropped, damaged or malfunctioned in any manner. Any repairs, or
electrical, or mechanical adjustments should be made by a qualied electrician.
• Do not insert hand or object into the rotation part (impellers).
• Make sure to disconnect power before touching, moving or servicing unit.
• Properly mount fan to a secure surface before operating.
• Do not overload your circuits. Check amp draw relative to amps available on the
circuit you want to connect the fan to.
• Do not allow any type of liquids to make contact with the fan.
• This product is intended for indoor use only.
• Use only with electrical wiring that is in good working order and meets applicable
codes.
• After completing installation, electric work, and duct work, perform the test operation
to check if it operates normally.
• After injecting the power, if wing is not rotating or rotation is slow, cut off the power
and check if the line connection is normally made.
• Check whether there is an abnormal sound or loss of wind during rotation.
• BEFORE CLEANING THE FAN DISCONNECT THE POWER CORD.
• Make periodic cleaning on lter absorption side & discharge head.
1. Outward Drawing
2. Capacity
3. Caution in Installation
Model No. Suction A Discharge B C D E F G
736600 3.9 3.9 9.4 9.5 8.3 4.3 6.7
736605 5.5 5.5 11.1 11.9 9.4 3.5 6.8
736610 7.6 7.5 13.4 13.8 12.0 3.5 8.3
736675 10 10 14.2 14.7 8.7 6.3 8.66
736680 12 12 15.7 16.2 9.8 7.48 9.64
736685 12 12 15.7 16.2 9.8 7.48 9.64
Model No. 736600 736605 736610 736675 736680 736685
Volt / Phase 120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 240v / 120 Hz
Power Input:
W90 124 164 230 300 310
Amphere: A 0.8 1.12 1.49 1.94 2.54 1.3
Revolution:
RPM (MAX) 3300 3225 3225 3090 3340 3340
Air Volume:
CFM (MAX) 170 440 740 780 1060 1060
Static Pressure:
Inch/Water(MAX) 2.01” 2.28” 2.30” 3.06” 3.54” 3.54”
Weight: Kg 2.8 3.0 9.0 8.0 9.5 9.5
1) When installing and carrying, be careful not to deform the impeller. If the wings are
deformed, it will be unbalanced and cause noise and vibration.
2) Use a lter on the absorption axis to prevent dust, oil and other foreign substances
on the impeller. (Filter selection may cause pressure loss for each type as well as the
wind volume may be lowered.)
3) For installation on the ceiling, make sure to install an inspection hole of at least
18” x 18” for repair and inspection.
4. How to Install
Fan can be mounted to a oor, ceiling or wall. Attach fan to a sturdy surface like a stud
or other solid wood. Do not attach to a weak surface like sheetrock.
In all cases use the xed mounting bracket and appropriate nuts and bolts to
attach the fan.
5. Test Operation
6. Maintenance