Edge Lighting PSB-30-12VDC User manual

PSB-30-12VDC
Installation Instructions for 30 Watt 12 Volt DC LED Power Supply
1
904-PSB-30-12VDC-04
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
SAVE THESE INSTRUCTIONS!
- Do not install this power supply in a wet location.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install *LED fixture closer than three inches or as
specified in the *LED fixture installation instructions to
curtains or similarly combustible materials. Keep insulation
at least 3" away from the enclosure.
- Turn the electrical power off before modifying the lighting
system in any way.
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
* See LED fixture installation instructions for proper
placement.
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions "
before installation.
- NOTE: To avoid overheating the power supply, install it in a
ventilated remote location where air flows. Maintain proper
spacing among power supplies when multiple power
supplies are installed in the same remote location.
- This product is not suitable for wet locations. It is approved
for the use at any height above the finished floor.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- TO REDUCE RISK OF FIRE, it is important to wire the
power supply for the system as described in this
installation instruction.
- Load the power supply to MAXIMUM 30 Watts.
- Use Lightolier "ZP600FAM120" 0-10 volt controller to dim
the Warm White LED soft strip.
- Use CDP color dial or CTP color touch screen controller with
RGB LED soft strip.
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
LOW VOLTAGE WIRE SIZE CHART
POWER SUPPLY
WATTAGE
WIRE SIZE
UP TO 26 FT
WIRE SIZE
FOR 27-41 FT
WIRE SIZE
FOR 42-68 FT
WIRE SIZE
FOR 69-100 FT
30 WATT
12 Volt #14 GA #12 GA #10 GA #8 GA
© 2015 Edge Lighting. All Rights Reserved.

"N" White
"L" Black
" " GREEN
T
White +
Black -
"N" White
"L" Black
" " GREEN
White +
Black -
"N" White
"L" Black
" " GREEN
T
White +
Black -
Using LED Power Supply with a Light Switch & Warm White
Soft Strip (Non-Dimmable)
1: Loosen the six Phillips screws on front of the power supply to
remove the cover.
A
B
2: Install conduits from the light switch, main panel (line
voltage) and soft strip to the power supply case.
3: Run proper size wires from the light switch electrical box to
the power supply case.
4: Run the line voltage power wires from the panel to the
power supply case.
1
POWER SUPPLY
ELECTRICAL BOX
CONDUIT
2
4
2
LIGHT SWITCH
COVER
PHILLIPS SCREW
CASE
5: Connect the hot power wire to one of the wires coming
from the switch with a wire nut.
6: Connect the other switch wire to the black power supply
wire marked "L" with a wire nut.
7: Connect the neutral power wire to white power supply wire
marked "N" with a wire nut.
8: Make sure the green transformer wire is grounded in
accordance with local electrical codes.
C
5
6
NOTE: Skip this section if dimming the warm white LED soft
strip or using RGB soft strip.
POWER LINE WIRES
7
8
3

"N" White
"L" Black
" " GREEN
T
White +
Black -
3
Using LED Power Supply with Warm White Soft Strip & 0-10
Volt Dimmer
SELV
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
F
COVER PHILLIPS SCREW
1
CASE
PHILLIP
SCREW
COVER
WIRE
TERMINAL
BLOCK
2
DIM MODULE
1: Loosen the six Phillips screws on front of the power supply to
remove the cover.
2: Loosen the two Phillips screws on the front of the dim
module (OT-DIM – sold separately) and remove the covers to
expose the terminal blocks.
ECOVER
0-10V
Dimming LED + LED -
L N G
PHILLIPS SCREW
15
16
11: Connect the white power supply wire marked "+" to red
conduit wire going to the soft strip.
12: Connect the black power supply wire marked "-" to black
conduit wire going to soft strip.
13: Connect the red conduit wire to red soft strip wire(s) with a
wire nut.
14: Connect the black conduit wire to black soft strip wire(s)
with a wire nut.
9: Use the "Low Voltage Wire Size Chart" on page 1 to
determine the proper wire size connecting the power supply
to the LED soft strip.
10: Run the proper size, red and black wires from the power
supply case to the LED soft strip.
NOTE: Maximum length of a single soft strip to be
connected to power supply before re-feeding is 16' of SS1 or
8' of SS3.
NOTE: Use only 12 volt LED soft strip with this power
supply.
15: Replace the power supply cover and secure it by tightening
the six Phillips screws.
NOTE: Skip this section if using the LED power supply with
a RGB soft strip.
2
"N" White
"L" Black
" " GREEN
White +
Black -
D
14
13
LED SOFT STRIP
12
11

"N" White
"L" Black
" " GREEN
White +
Black -
SELV
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
DIM MODULE
POWER SUPPLY
"N" White
"L" Black
" " GREEN
White +
Black -
SELV
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
DIM MODULE
POWER SUPPLY
4
SELV
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
3
DIM MODULE
G
ELECTRICAL BOX
3LIGHTOLIER:
ZP600FAM120
CONTROLLER
5
4
CONDUIT
3
POWER SUPPLY
3: Install the conduits from the dimming controller, main panel
(line voltage), and soft strip to the power supply case.
4: Run proper wire size and color from the controller electrical
box to the power supply case.
5: Connect the black, white, red, purple, and gray controller
wires respectively to black, white, red, purple, and gray wires
with a wire nut. The yellow controller wire is not used in this
procedure. Cap the yellow controller wire with a wire nut. For
three way switching, refer to the instructions provided with
the controller.
H
LINE
VOLTAGE
WIRES
LIGHTOLIER:
ZP600FAM120
CONTROLLER
6: Run the line voltage power wires into power supply case.
7: Connect the hot power wire to black controller wire with a
wire nut.
8: Connect the neutral power wire to white controller wire
and the white power supply wire marked "N" with a wire
nut.
9: Connect the red controller wire to black power supply wire
marked "L" with a wire nut.
10: Make sure the green transformer wire is grounded in
accordance with local electrical codes.
12
I
11
11: Connect the gray controller wire to "-" terminal of "1-10V"
dim module.
12: Connect the purple controller wire to "+" terminal of
"1-10V" dim module.
8
7
9
13: Connect the white power supply wire marked "+" to "+"
terminal of "12-24V" dim module.
14: Connect the black power supply wire marked "-" to "-"
terminal of "12-24V" dim module.
6
"N" White
"L" Black
" " GREEN
White +
Black -
J
13
14

LED SOFT STRIP
21
20
15: Use the "Low Voltage Wire Size Chart" on page 1 to
determine the proper wire size connecting the dim module
to the LED soft strip.
16: Run the proper size, red and black wires from the dim
module case to the LED soft strip.
17: Connect the red wire to "+" terminal of dim module
output.
18: Connect the black wire to "-" terminal of dim module
output.
19: Replace the covers of the dim module and secure them by
tightening the Phillips screws.
20: Connect the red wire coming from the dim module to the
red wire of each LED soft strip.
22: Connect the black wire coming from the dim module to
the black wire of each LED soft strip.
K
NOTE: Maximum length of a single soft strip to be
connected to power supply before re-feeding is 16' of SS1 or
8' of SS3.
NOTE: Use only 12 volt LED soft strip with this power
supply.
5
18
17
16
LCOVER
0-10V
Dimming LED + LED -
L N G
PHILLIPS SCREW
23
23: Replace the power supply cover and secure it by tightening
the six Phillips screws.
Using LED Power Supply with RGB Soft Strip & CDP or CTP
Controller
POWER SUPPLY
M
M
1
COVER
PHILLIPS SCREW
CASE
M
DVR-RGB-60
COVER
2
NOTE: Refer to the instructions provided with the CDP
(Color Dial Controller) or CTP (Color Touch Screen Controller)
to install, power, and program them. This section shows
typical CDP controller installation.
1: Loosen the six Phillips screws on front of the power supply to
remove the cover.
"N" White
"L" Black
" " GREEN
T
White +
Black -
NOTE: Use a DVR-RGB-60 (Sold Separately) with this power
supply.
2: Carefully pull off the cover from the DVR-RGB-60 driver.
(Sold-Separately).

M
"N" White
"L" Black
" " GREEN
White +
Black -
M
N
ELECTRICAL BOX
CONDUIT
9
8
CONTROLLER
CONTROLLER
POWER SUPPLY
DMX CABLE (BELDEN #9841)
"N" White
"L" Black
" " GREEN
White +
Black -
NOTE: Use a deep double gang box to fit the controller and
controller power supply (OT-20-120-240-245 recommended).
3
7
6
5
3: Connect one end of a red wire to "VDC+" of the controller
terminal and the other end of the red wire to the "+24VDC"
of the power supply terminal.
4: Connect one end of a black wire to "Ground" of the controller
terminal and the other end to the "-24VDC" of the power
supply terminal.
5: Run the black and white line voltage wires coming from
the controller power supply to the power supply case.
6: Connect the white wire to "N" terminal of the controller
power supply.
7: Connect the black wire to "L" terminal of the controller
power supply.
8: Install conduits from controller, main panel (line voltage),
and soft strip to power supply.
9: Run proper DMX cable (Belden #9841 recommended)
with three data wires from controller to the power supply
box.
NOTE: Refer to the "Configuring DimWheel" & "Operating
DimWheel" on page 8 & 9 to properly operate the controller.
4
O
13
11
EXT in-
EXT in+
VDC-
VDC+
DMX in +
DMX in -
DMX in
shield
LEDSync
out +
LEDSync
out-
LEDSync
out shield
12
CONTROLLER
10: Install a red wire from the power supply "+V" terminal to
DVR-RGB-60 "VDC+" red terminal and a black wire from
power supply "-V" terminal to DVR-RGB-60 "VDC-" blue
terminal.
11: Connect one end of a data wire (blue with white stripes
wire) to controller "LEDSYNC OUT–" terminal. Connect the
other end into the DVR-RGB-60 "DMX in –" terminal.
12: Connect one end of a data wire (white with blue stripes
wire) to controller "LEDSYNC OUT+" terminal. Connect the
other end into the DVR-RGB-60 "DMX in +" terminal.
13: Connect one end of a data wire (bare shield wire) to
controller "LEDSYNC SHIELD" terminal. Connect the other
end into the DVR-RGB-60 "DMX in shield" terminal.
10
"N" White
"L" Black
" " GREEN
White +
Black -
P
M
CONDUIT 15
16
17
14: Run the line voltage power wires into the power supply.
15: Connect the hot power wire to black power supply wire
marked "L" and black wire coming from the controller
power supply with a wire nut.
16: Connect the neutral power wire to white power supply wire
marked "N" and white wire coming from the controller
power supply with a wire nut.
17: Make sure the green transformer wire is grounded in
accordance with local electrical codes.
6
DO NOT
USE
NOTE: "DMX in+", "DMX in-", "EXT in+" & "EXT in-", controller
terminals are not used on controller.

27: Replace the DVR-RGB-60 cover.
28: Replace the power supply cover and secure it by tightening
the six Phillips screws.
7
Q
19
18
18: Connect the white power supply wire marked "+" to
DVR-RGB-60 "Vdc+" red terminal.
19: Connect the black power supply wire marked "-" to
DVR-RGB-60 "Vdc-" blue terminal.
20: Use the "Low Voltage Wire Size Chart" on page 1 to
determine proper wire size connecting to the DVR-RGB-60
terminals.
21: Run the proper size green, red, blue, and black wires from
the RGB LED soft strip to the power supply case.
22: Run the proper size green, red, blue, and black wires from
the RGB LED soft strip to the power supply case.
23: Connect the black wire into DVR-RBG-60 "LED SUPPLY +"
white terminal. Connect the other end to RGB soft strip
black wire(s).
24: Connect the red wire into DVR-RBG-60 "Group 1-" red
terminal. Connect the other end to RGB soft strip red
wire(s).
25: Connect the green wire into DVR-RBG-60 "Group 2-" green
terminal. Connect the other end to RGB soft strip green
wire(s).
26: Connect the blue wire into DVR-RGB-60 "Group 3-" blue
terminal. Connect the other end to RGB soft strip red
wire(s).
NOTE: Use only 12 volt LED RGB soft strip with this power
supply.
R
LED SOFT STRIP
23
24
21
NOTE: The DVR-RGB-60 terminals adapt maximum 18 AWG
size. To avoid voltage drop, use 6" of 18 AWG size in RGB
terminals connected inline to proper size gauge wire attached
to the RGB LED wires with wire nuts. See the "Low Voltage
Wire Size Chart" on page 1.
25
26
SCOVER
0-10V
Dimming LED + LED -
L N G
PHILLIPS SCREW
28
"N" White
"L" Black
" " GREEN
White +
Black -
M
CONDUIT
NOTE: This power supply is for multiple runs. Do not exceed
the maximum wattage of the power supply.

24VDC + -
LINE
N L
EXT in-
EXT in+
VDC-
VDC+
DMX in +
DMX in -
DMX in
shield
LEDSync
out shield
LEDSync
out+
LEDSync
out-
POWER SUPPLY
"N" White
"L" Black
" " Green
White +
Black -
SELV
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
M
Ext in-
Ext in+
DMX in +
DMX in -
DMX in shield
LedSync thru+
LedSync thru-
LedSync shield
VDC+
VDC-
LED supply +
Group 1 -
Group 2 -
Group 3 -
Group 4 -
8
POWER SUPPLY
Using LED Power Supply with Warm White Soft Strip & 0-10 Volt Dimmer
GND
L
N
LIGHTOLIER:
ZP600FAM120
CONTROLLER
LED SOFT STRIP
DIM MODULE
GND
Using LED Power Supply with RGB Soft Strip & CDP or CTP Controll
GND
L
N
CDP CONTROLLER
RGB LED
SOFT STRIP
CONTROLLER
POWER SUPPLY
DVR-RGB-60
Wiring Diagrams
DMX CABLE
(BELDEN #9841)
"N" White
"L" Black
" " Green
White +
Black -
T
O N
1 2 3 4 5 6 7
CONTROLLER FACE PLATE
FLAT HEAD
SCREW
PUSH
BUTTON
1.5MM ALLEN
WRENCH
29
30
29: Align the face plate to the controller and secure using the
two flat head screws.
30: Attach the push button onto the controller center rod and
secure by tightening the M3 set screw with the 1.5mm Allen
wrench provided.
DO NOT
USE
DO NOT
USE

9
Operating CDP
1- Turn the light on 2- Change brightness 3- Turn the light off
BRIGHTNESS
Selecting Modes
O N
1 2 3 4 5 6 7
COLOR MODE
O N
1 2 3 4 5 6 7
Configure your CDP by setting the DIP switches on the front:
NOTE: The DIP switches must
remain accessible after installation.
When making changes in the DIP
switch settings, disconnect and
reconnect the power supply to
activate new settings.
CHASE MODE
1- Turn the light on 3- Set Color2- Activate configuration mode
2 SEC
4- Save color saving
Advanced Operation for Color Mode
TAP TAP
1- Turn the light on 3- Set show speed2- Activate configuration mode
2 SEC
4- Save color setting
Advanced Operation for Chase Mode
TAP TAP
TAP TAP
Table of contents
Popular Power Supply manuals by other brands

Keysight Technologies
Keysight Technologies N6700 user guide

PowerBox
PowerBox Camtec OSW00301 quick start guide

Texas Instruments
Texas Instruments UCD3138 Technical reference manual

ACCURAT
ACCURAT SOLID 1500 instruction manual

Optimal Power
Optimal Power OPR Power Series OPR300-05S user manual

Agilent Technologies
Agilent Technologies E3634A Service guide