Edgetech pulse 070 User manual

Installation and Operating
Instructions
pulse
POOL PUMP
Attention Installer
This manual contains important information about the installation,
operation and safe use of this product. Once the product has been
installed this manual must be given to the owner/operator of this
equipment.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 2
Table of Contents
GENERAL INFORMATION………………………………
3
INSTALLATION………………………………………......
3
ELECTRICAL CONNECTION…………………………....
4
OPERATION –PRIMING……………………………….
4
HAIR AND LINT POT –MAINTENANCE…………....
5
GENERAL –MAINTENANCE ………………………….
6
TROUBLE SHOOTING GUIDE………………………….
7
WARRANTY INFORMATION…………………………..
8
PULSE SPECIFICATIONS…………………………………..
9
SPARE PARTS…………………………………………….
10
NOTES……………………………………………………..
11
!
!
Pulse Pool Pump Details
Model Number:
Serial Number:
Date of Purchase:
Invoice Number:

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 3
General
The Pulse series pool pump has been specifically designed to operate todays swimming pools, its
high performance and high head flow characteristics will ensure that the Pulse pool pump will
operate with all your ancillary equipment including chlorinators, heaters, in floor cleaners and pool
cleaners.
Installation of the Pulse Pool Pump
Edgetec Systems Pty Ltd has applied the latest CAD design software in designing your Pulse Pool
Pump to ensure that you have many years of trouble free operation. Here are some simple
installation rules that should be followed when installing the Pulse pool pump;
1. Care should be taken to position the pump so that it has adequate drainage. Ensure the
motor cannot become wet or flooded and the pump location should be well ventilated.
The pump should be protected from direct sunlight and weather.
2. Ensure that the pump is secured onto a stable base. The pump mounting foot has
mounting points where the pump can to be bolted to the base to prevent movement.
3. The pump foot has an anti-vibration pad moulded into the base to minimise noise and
vibration. Failure to secure the pump to the base securely may cause damage and void the
warranty.
4. The pump must be accessible for maintenance and be easily removed for service. Ensure
that you allow enough area around the hair and lint pot basket for removal and cleaning.
5. The pump suction line requires a minimum of 50mm PVC pipe and should be kept as short
as possible with the minimum number of elbows and bends and no air trap for optimum
performance. The suction line must be installed below the water level until just in front of
the pump location and the vertical riser used to reach the pump inlet. Note: Wear
protective gloves when using PVC glue and solvents and always allow 24 hours to dry
before starting the pool pump.
6. The suction and return pipe work should be self-supported so that no strain from the
pipework loads up the pump barrel unions. The pump should not be suspended by the
pipe work or other equipment as this will cause leaks and eventual damage to the pump.
Only use the barrel unions supplied with the pump, barrel unions only require to be hand
tight, do not use tools to tighten the barrel union nuts.
7. If the pump is installed below the water level - isolation valves must be fitted to the
suction and return lines.
8. Pump installations that are 500mm or more above the water level will require a foot valve
at the pool or a check valve in the suction line.
9. Water temperature must not exceed 45°.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 4
Electrical Connection
1. IMPORTANT! - The electrical installation must be performed by a licensed electrician and
must conform to all national, state and local codes. Australian Wiring Rules AS3000
2. The PULSE pump must be supplied through a residual current device (RCD) with a rated
residual operating current of 30mA.
3. If the supply cord is damaged it must be replaced by Edgetec Systems or its service agent or
a suitably qualified person.
Operation-Priming
The Pulse series pool pump has been designed to prime and re prime as long as the hair and lint pot
bowl is full of water and there is adequate supply from the suction points.
Priming/Start up
1. If the pump is installed above the water level and the hair and lint pot has no water in the
bowl, close off the valve in the suction line (if fitted), remove the hair and lint pot lid, and fill
the bowl with water and replace the hair and lint pod lid ensuring that its fitted correctly.
2. If the pump is installed below the water level, open the valves and you should see the water
flow freely into the hair lint pot bowl.
3. Switch the pool pump on.
4. The pump should now be primed and running; however, on some installations the priming
time may alter depending on the elevation and the length of pipe on the suction line.
5. If after around 90 seconds the pump has not primed switch the pump off and repeat step 1.
If after a number of attempts you still cannot prime the pump check your connections for
any leaks, it may be necessary to fit a foot or check valve to obtain prime.
6.
!
!
WARNING
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
!
WARNING
Never run your pool pump without water as this can cause serious damage to the mechanical
seal which may cause the pool pump to leak.
Running the pump without water will void your warranty.
!
WARNING
FOR YOUR SAFTEY: This Product must be installed and serviced by a qualified service
technician. Improper Electrical installation can create dangerous electrical hazards which could
cause death, serious injury or property damage. Improper installation will void the warranty.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 5
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVIODED, CAN RESULT IN SERIOUS
INJURY AND/OR DEATH.
Do not block the pump suction, as this can cause severe injury and/or death. Do not use this
pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certified to the
latest published version of AS 1926.3
`
Hair and lint Pot Basket - Maintenance
Your Pulse series pool pump has been designed to run for extended periods of time, however, the
hair and lint pot basket should be inspected and cleaned on a weekly basis or more regularly if
required, to do this follow the steps below;
1. Turn the power off to the pump and close the isolation valves.
2. Undo the hair and lint pot lid by turning the hair and lint pot locking ring in an anticlockwise
direction (approximately 1/8 of a turn) and remove the hair and lint pot basket.
3. Clean the debris from the basket and clean with water if required.
4. Replace the hair and lint pot basket into the pump aligning the open section of the basket
with the inlet of the pump. If the basket is not fitted correctly the lid will not be able to be
refitted.
5. Replace the hair and lint pot locking ring and tighten in a clockwise direction approximately
1/8 of a turn. Hand tighten the lid only, do not use any tools to tighten the lid.
6. Fill the hair and lint pot bowl with water (if required) and open the isolation valves and
switch the pump on.
!

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 6
General Maintenance
1. On a monthly basis check the area around the pump motor to ensure that it is clear of
debris, i.e. leaves, sand and dirt etc. Failure to keep this area clean may cause the pump fan
cowl to become blocked and cause the pump to overheat.
2. Check the hair and lint pot basket regularly, blocked lint basket or suction line will limit the
water to the pool pump and will cause serious damage and void your warranty.
3. On a monthly basis check the O rings on your hair and lint pot lid and pump barrel union O
rings for leaks. Should any leak be detected, clean and regrease the O Rings or replace if
required. Do not use petroleum based grease or Vaseline.
4. Check under your pump every 3 months to ensure that it is not leaking; if a leak is found call
a pool service technician for repair.
5. Maintain your water and chemical balance.
6. Do not add salt, chlorine, acid or any chemicals directly into your skimmer box, this may
cause damage to your pump and possibly void your warranty.
7. If there is large amounts of sand or grit in your pool always use a filter sock in your hair and
lint pot basket, otherwise the sand and grit passing through your pump could cause serious
damage.
8. In cold climates where the pool pump maybe subject or exposed to frost or freezing, we
recommend that the pump not be used during this time and that the water be drained
completely. There is a drain point located on the hair and lint pot and a ¼ BSP drain plug can
be sourced from Edgetec Systems.
9. Should your pool pump require servicing and you cannot locate a service person, please
contact Edgetec Systems for their nominated service outlet.
10. Use only genuine Edgetec parts when replacing or maintaining your pool pump.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 7
Trouble Shooting Guide
Symptoms
Possible Cause
Remedy
Pump will not prime.
No water in the pump.
Air leak.
Blocked lined or closed valves.
Ensure that the hair and lint pot is full/Ensure water level is
correct in the pool
Ensure that the water level is correct at the suction points.
Tighten all barrel unions and fittings on the suction side of
the pump.
Check that all the valves are in the open position.
Check that the skimmer and/or hair and lint pot basket are
free from debris.
Ensure that the pump impeller is not jammed or blocked.
Low Flow.
Dirty Filter.
Skimmer basket and/or hair
lint pot basket.
Valves are in closed position.
Sand Filter - Check and backwash filter.
Cartridge Filter- remove and clean cartridge element.
Check and clean both baskets.
Open the valves.
Pump will not run.
No power.
Jammed pump impeller.
Check to ensure that the power point is switched on.
Ensure that the RCD has not tripped.
Check that the time clock (if fitted) on other equipment is
set correctly.
Switch the power off to the pump, see if the pump shaft
spins freely by rotating the pump shaft at the back of the
pump motor. If still jammed consult you pool service
technician or Edgetec.
Pump cuts out on
over load.
Ventilation.
Low or incorrect voltage.
Check that the pump is free from debris.
Check that the pump is not in direct sunlight.
Have an electrician check the power supply to the pump.
Ensure that the pump is not running off an extension lead.
Noisy Pump.
Motor bearings.
Foreign matter in the pump
impeller.
Air leak.
Have the motor bearing replaced by an authorised person
or Edgetec.
Remove pump and clean foreign matter from impeller.
Check that there is no air leaks in the suction line causing
the pump to cavitate. Tighten all fittings.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 8
Pulse Series Pool Pump Warranty
Edgetec Systems Pty Ltd warrants that this item sold hereunder shall be free from defects in material
and workmanship for a period of two (2) years from the original purchase date and to the original
purchaser and are not transferable to new owners.
This warranty is only valid when the product is installed and used in the normal manner in
accordance with the installation and operating instructions provided, failure to do so will void your
warranty.
The product warranty does not cover the following:
Fair wear and tear, negligence, misuse or abuse.
Incorrect installation.
Running the pump dry.
High voltage strikes, lighting strikes or acts of nature.
Water damage from external sources.
Inadequate ventilation.
Repairs by unauthorised persons.
Incorrect voltage.
Addition of chemicals directly through the skimmer box
OR
The replacement of maintenance items used in routine general maintenance are not covered by this
warranty. Maintenance items may include (but not limited to):
Motor Bearings.
O-rings
Mechanical seals.
Proof of Purchase: All warranty claims must be accompanied with the original purchase documents,
without proof of purchase the warranty will not be considered.
Commercial Warranty: Has a limited warranty of one (1) year from the date of purchase to these
commercial installations includes (but not limited to) hotels, motels, caravan parks, health clubs,
public pools and body corporate installations etc.
To obtain warranty replacement or repair, the pump should be returned to the original place of
purchase or to Edgetec Systems Pty Ltd.
Edgetec Systems Pty Ltd goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for
any other reasonably foreseeable loss or damage. You are entitled to have the goods repaired or
replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure.
No unauthorized personnel can make any warranty representation on the behalf of Edgetec Systems
Pty Ltd unless with their written permission.

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 9
Pulse Pool Pump Specification
Pump
Model
Hp
Supply
Voltage
Power
(watts)
Current
(amps)
Width
(mm)
Height
(mm)
Length
(mm)
Pulse 070
1.0
230-240
750
4.4
210
230
549
Pulse 090
1.25
230-240
925
5.6
210
230
574
Pulse 110
1.5
230-240
1100
6.2
210
230
574
Electrical Approval SGS 538 Noise Rating 65 dB (1m)
Flow (LPM)
Head (kPa)
pulse 070 090 110

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 10
Pulse Pool Pump Spare Parts Listing
Parts Listing
Item #
Description
Part #
Item #
Description
Part #
1
Fan Cowl
10-0029
16
Impeller 1.5Hp
10-0001
2
Fan
9-2020
17
Diffuser
10-0009
3
Capacitor Cover
9-2024
18
Screws Diffuser (5)
10-0024
4
Capacitor Cover Gasket
9-2025
19
Diffuser Throat
10-0008
5
PCB Fuse Terminal
9-5128
20
Pump Casing
10-0014
6
Capacitor 20 uf 450 v 1Hp
9-2028
21
Check Valve
10-0010
6
Capacitor 30 uf 450 v 1.25Hp & 1.5Hp
9-2029
22
Hair & Lint Pot O Ring
10-0016
7
Capacitor Base
10-0025
23
Hair & Lint Pot Lid
10-0006
8
Grommet
9-2022
24
Hair & Lint Pot Lock Ring
10-0007
9
Motor 746 Watt
10-0026
25
Barrel Union Nuts (2)
10-0013
9
Motor 1100 Watt
10-0027
26
Barrel Union Pipe Socket (2)
10-0011
10
Motor Base
10-0021
27
Barrel Union O ring (2)
10-0012
11
Anti-Vibration Pad
10-0022
28
Hair & Lint Pot Basket
10-0005
12
Rubber Flinger
10-0028
29
Screws Casing (4)
10-0019
13
Back Plate
10-0018
30
Nut Casing M8 1.25 NP Brass (4)
10-0020
14
Mechanical Seal (John Crane)
10-0017
31
Screw Motor Foot M4
10-0023
15
Casing O Ring
10-0015
32
Lead 10amp 3 Pin 2 Metre
9-2030
16
Impeller 1.0Hp
10-0003
33
Nut Lead Gland M20
9-2031
16
Impeller 1.25Hp
10-0002
34
Grommet Lead Gland 6mm
9-2032

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 11
Notes

Pulse Pool Pump Installation & Operating Instructions –Part # 10-0030 Nov 2012 Page 12
pulse
by
Proudly Australian Owned
13 Lieber Grove
Carrum Downs Victoria 3201
Australia
Tel: (613) 9775 0882 Fax: (613) 9775 0881
Email: sales@pulsepumps.net
Web: www.pulsepumps.net
New Zealand
Industrial Plastic Shapes Pty Ltd
95 Diana Dr Glenfield
North Shore City 0745
Tel: +64 9 442 4051 Fax: +64 9 442 4053
Email: [email protected]om
Web: www.ipsnz.com
This manual suits for next models
2
Table of contents
Popular Swimming Pool Pump manuals by other brands

STA-RITE
STA-RITE DURA-GLAS PE Series owner's manual

Wayne
Wayne WAPC250 Quick start instructions

STA-RITE
STA-RITE 5P2R Installation and user guide

Gullberg Jansson
Gullberg Jansson GJPACW1V-15 Installation and maintenance guide

Davey
Davey WHISPER Series Installation and operating instructions

Wilo
Wilo Wilo-FilTec FBS Installation and operating instructions