ehb electronics HC 960 User manual

.
Operating Instructions
HC 960
Version 2.1
The dissemination of information from, and reproduction of, these documents as well as the utilisation and communication of their content is not permitted
unless specifically authorised. Any infringement shall result in liability for damages. All rights are reserved, particularly with regard to the granting of
patents or registration of utility models.

HC960 Operating Instructions
1/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
Table of contents
1. General information .................................................................................................... 2
1.1. Operating states...................................................................................................... 2
1.2. HC960 operating modes ......................................................................................... 2
2. Meaning of parameters ............................................................................................... 2
3. Graphical representation of functions.......................................................................... 4
4. Programming the parameters...................................................................................... 5
5. Chipper control sequence (Normal RPM = 0).............................................................. 6
6. Chipper control sequence (Normal RPM > 0).............................................................. 7
7. Operating hours counter ............................................................................................. 8
8. Output assignment...................................................................................................... 8
9. Amphenol connector ................................................................................................... 9
10. AMP connector ......................................................................................................... 10
11. Technical data .......................................................................................................... 11
12. Important information on use..................................................................................... 12
13. Repairing devices……………………………………………………………………………13
14. Disposal of devices ................................................................................................... 13
15. Documentation information and history..................................................................... 14
17. Legal information ...................................................................................................... 14

HC960 Operating Instructions
2/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
1. General information
The HC960 chipper controller includes automatic control for the feed rollers of a wood chipper, a revolu-
tion counter, a daily counter and a total operating hours counter. When operating the HC960, a distinction
is made between two different operating states.
1.1. Operating states
Normal operation
In normal operation the HC960 has a display function. Depending on whether the blade shaft is rotating
or not, either the speed or the total operating hours are displayed.
Before the HC960 can be used, a basic parameter setting must be made. On the following page the indi-
vidual parameters are listed both with their designation (these appear in the display) and their meaning.
Programming the parameters
Setting different basic values to adapt the HC960 to different chipper types. Programming the parameters
is only necessary during initial commissioning.
1.2. HC960 operating modes
When operating the HC960, a distinction is made between fully automatic (Normal RPM parameter > 0)
and semi-automatic mode (Normal RPM parameter = 0). The user can decide for himself in which operat-
ing mode he wants to operate the HC960.
In semi-automatic mode, the blade shaft must be raised to the desired speed after starting the diesel en-
gine. This target speed can then be saved by pressing the set button. The feeder is switched on at the
same time. The set display flashes until the target speed is set for the first time. If the speed of the blade
shaft is changed during operation and then the set button is pressed again, the new target speed is
saved. This happens every time the Set button is pressed.
2. Meaning of parameters
Name
Meaning
Remark
Normal
RPM
Normal speed Preset target speed which the blade shaft should hold and at which
the feed rollers are started (if a restart speed is programmed, this has
priority; see also Return RPM parameter). After a drop in speed, the
target speed must be reached again in order to switch on the feed roll-
ers again. If the value "0000" is entered here, this means that the
blade shaft must be brought to a certain speed after starting the motor,
which can then be saved by pressing a button (learn function).
Permitted value: 0 - 5000 rpm
The limits are influenced by the settings for overspeed and under-
speed
Return
RPM
Restart speed Speed at which the feed is switched on again. (Note: this parameter
has priority over the parameter "n"). It is only to be used in semi-auto-
matic mode. A value should be entered here which is slightly below
the normal speed. As the value for the normal speed in this operating
mode can be changed at any time via the learn function, it is recom-
mended to enter a percentage value. In fully automatic mode the value
"0" must be entered here. The entry can be a percentage or an abso-
lute value, depending on the procedure for entering the minimum
speed.
Permitted value: 0 - 99% or 0 - 5000 rpm
The limits are influenced by the settings for overspeed and under-
speed

HC960 Operating Instructions
3/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
LOW
RPM
Underspeed Deviation from the target speed. If the speed falls below this minimum
speed, the feeder is stopped to allow the blade shaft to reach its target
speed again. The minimum speed can be entered both as an absolute
value and as a percentage deviation from the target speed. To enter a
percentage deviation, use the minus button (down arrow) to go past
zero. A percentage value is indicated in the display by a "%". For ex-
ample, "5%" corresponds to a percentage deviation of 5%. If the dis-
play shows "0850", for example, this means that 850 rpm has been
programmed as the minimum speed. If a "zero" is entered for this pa-
rameter, the minimum speed is not monitored.
Permitted value: 0 - 99 % or 0 - 5000 rpm
Over
RPM
Overspeed Upper permissible speed of the blade shaft. If this speed is reached or
exceeded, the feed rollers are stopped. The entry can be a percentage
or an absolute value, depending on the procedure for entering the
minimum speed. If a "0" is entered for this parameter, the overspeed is
not monitored.
Permitted value: 0 - 99% or 0 - 2700 rpm
IPR rotor Pulses per
rotation
Number of pulses emitted by an initiator per revolution of the blade
shaft.
Permitted value: 1 - 60
Confirm
start
Confirm start Selection of whether the initial start of the feed must be confirmed with
"set" for increased operator safety.
Permitted value: Off/On
RPM-
sensor
NPN/PNP With the selection NPN/PNP the frequency input can be configured to
the type of input signal.
Set PW Set password Set password to access the parameter menu.
Permitted value: 0000 - 9999
Daily
pass-
word
Password for the
daily operating
hours counter
Set password for resetting the daily operating hours counter.
Permitted value: 0000 - 9999
Factory
setting
Factory setting Reset HC960 to factory settings. No. shows how often the option has
already been used.
Permitted value: No/Yes
Set total
hours
Set total hours Set total operating hours.
Permitted value: 00000 - 99999
Lan-
guage
Language set-
tings
Setting the language
Permitted value:
Exit Exit Exit parameter menu:

HC960 Operating Instructions
4/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
3. Graphical representation of functions
This representation refers to the software S02422.
* The output corresponds to the respective pictogram on the pin assignment (page 9).

HC960 Operating Instructions
5/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
4. Programming the parameters
The parameters must always be programmed when the machine is at standstill. To access the parameter
setting in operating mode, switch on the device while holding down the set button. Press the set button
until the display shows "*** parameter ***". Use ↙and ↗to scroll to the desired parameter. Use "set" to
be able to change the parameter. Afterwards the value can be adjusted with ↙and ↗ and saved with
"set".
Termination of programming
If programming is terminated by switching off the device, all changes made since the last time the set but-
ton was pressed are retained.

HC960 Operating Instructions
6/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
5. Chipper control sequence (Normal RPM = 0)

HC960 Operating Instructions
7/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
6. Chipper control sequence (Normal RPM > 0)

HC960 Operating Instructions
8/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
7. Operating hours counter
The HC960 has two independent operating hours counters: A resettable daily operating hours counter,
which can be used for maintenance intervals, for example, and a settable total operating hours counter.
While the blade shaft rotates, its speed is automatically displayed. If you wish to display the daily operat-
ing hours instead, briefly press the set button once in fully automatic mode (Normal RPM greater than
zero). In semi-automatic mode (Normal RPM equals zero), however, the set button must be pressed for
longer than 3 seconds, as in this operating mode a brief keystroke will cause a new target speed to be
adopted.
To clear the daily operating hours counter, press the set button for longer than 3 seconds in both operat-
ing modes. After these 3 seconds have elapsed, there is a switchover to the display of the daily operating
hours. After a further 3 seconds (the set button is still pressed), the daily operating hours counter is
cleared. “0:00" appears. The specified times apply in each case starting from the speed display.
If no button is pressed for ten seconds, there is an automatic switchover back to the speed display.
When the blade shaft is stationary, the total operating hours (th = total hours) automatically appear in the
display. Here too, briefly pressing the set button switches to the display of daily operating hours.
The procedure described above for resetting the daily operating hours counter also applies here. If no
button is pressed for ten seconds, the display automatically switches to the total operating hours.
The total operating hours counter can be set via the parameter menu.
8. Output assignment
Depending on whether you need a N.O. or a N.C. contact for your magnet of the feed control, select the
appropriate contact on the HC960. Please also note the function of the output states, which are described
in detail in Figure 1 on page 4.
Pin assignment

HC960 Operating Instructions
9/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
9. Amphenol connector

HC960 Operating Instructions
10/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
10.AMP connector

HC960 Operating Instructions
11/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
11. Technical data
Electrical data:
Visualisation
Mechanical data:
Test standard
Voltage range 8-32V
Operating temperature -20°C to +70°C temporary discoloration of the display
Storage temperature -30°C to +80°C
Inputs Speed input for inductive encoder
Outputs Output for hydraulic valve 2A) semiconductor,
short-circuit protected
Total operating hours counter 0…99999 h
Daily operating hours counter 0…99:99 h
Speed measurement 1…5000 rpm
Pulses per rotation 1...60
Lower speed limit value 0...99% of normal speed
Restart speed 0...99% of normal speed
Display typ LCD
Resolution 32x128 Pixel
Background lighting yes
Display Black and white graphic display
Housing dimensions (L x W x H) 82 x 80 x 57 mm
Housing dimensions 7pin
(L x W x H)
82 x 80 x 100 mm
Housing dimensions 6pin
(L x W x H)
82 x 80 x 89 mm
Mounting dimensions (L x W x H) 82 x 80 x 77 mm ( with rubber-bonded metal )
Housing material ABS, PC (UV stabilized), light grey, Cover screw V2A
Weight 192g (without mounting connector)
Installation 4 x rubber-bonded metal, M4x10
Protection class IP54
Connection 7pin. Amphenol connector or
6pin AMP-CON-6 connector
Humidity DIN EN 60068-2-3
Vibration DIN EN 60068-2-6
Impact DIN EN 60068-2-27
EMV
DIN EN 61000-6-4, DIN EN 61000-4-20, DIN EN 61000-4-2, DIN EN
61000-4-3, DIN EN 61000-4-20, ISO 11451-1, DIN EN 61000-4-4, 61000-4-
5, DIN EN 61000-4-6
CE label according to directive 2014/30/EU

HC960 Operating Instructions
12/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
12. Important information on use
Test
Before delivering the installed HC960 to the end user, a brief functional test should
be carried out in the peripheral equipment that is to be used.
Use
This device is to be operated only in combination with the supplied accessories.
Protect the device from moisture and dust.
Cleaning should only be carried out with a slightly damp cloth and mild detergent.
Comply with the general accident prevention regulations during operation.
Safety
Do not operate the HC960 within range of strong electromagnetic fields.
Observe the temperature specifications. Protect the device especially from over-
heating.
Installation
Observe the notes of the manufacturer of the plugs and cable harnesses when in-
stalling the device.
Storage
An unused HC960 may only be stored within the temperature range -20°C to +
85°C.
Shipping
The original packaging must be used for all shipments.
Improper packaging is regarded as negligence and results in any claims for repair
under guarantee being forfeited.
Maintenance
The HC960 requires no maintenance and no special upkeep over its entire service
life.
ATTENTION!
Never use a high-pressure cleaner to clean the device.
Instruct your service personnel that any high-pressure
cleaning will cause damage and voids the warranty.

HC960 Operating Instructions
13/14 Version 2.1 © ehb Errors excepted
Y:\Vertrieb\01 Produkte\01 Produktinformationen Vertrieb\HC 960\Betriebsanleitung\HC 960_BA_V2.1_EN_23.11.2020_.docx
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
13.
Repairing devices
Should the device require repair work, please return it to:
ehb electronics gmbh
Hans-Böckler-Str. 20
30851 Langenhagen
GERMANY
Please make sure that you include a written fault description. This will facilitate the work of the ehb
electronics gmbh service department and ensure faster return of your HC 960.
Alternatively, you can use our online service for returning devices: www.ehbservice.de
NOTE!
ehb electronics GmbH assumes liability only for the proper execution of services
and the correct characteristics of the materials used. Any further claims such as for
loss of profit and for direct and indirect consequential damages such as loss of data
are excluded.
ATTENTION!
Damages arising from improper packaging of the device for shipping and/or unau-
thorised intervention will invalidate the guarantee.
14.Disposal of devices
Product
Please dispose of the product at the end of its service life in accordance with the legal provisions.
Rechargeable batteries and other batteries
As the final consumer, you are legally obliged to return all used rechargeable batteries and other
batteries (in accordance with the EU Batteries Directive). Disposal as household waste is not
permitted!
Batteries containing hazardous substances are identified by the symbol shown here, this symbol indicat-
ing that disposal as household waste is not permitted. The chemical symbols for the hazardous heavy
metals are:
Cd (cadmium)
Hg (mercury)
Pb (lead)
If a battery contains a hazardous heavy metal, the corresponding chemical symbol will appear on the bat-
tery, e.g. beneath the waste container symbol shown above. You can dispose of used batteries/recharge-
able batteries free of charge at your municipal collection points
and wherever batteries/rechargeable batteries are sold.
By acting in accordance with this disposal requirement, you will be fulfilling your legal obligations as well
as contributing to the protection of the environment.
Your compliance in this matter is appreciated.

HC 960 Translation of the original operat-
ing manual
14/14 Version 2.1 © ehb Errors
excepted
Bedienungsanleitung.doc •Stand/Version: 25.02.2005/00 •Layout: Gottschalk •\\Ehelec-nts-000\EHELEC\Iso 9001\Formblätter\Vorlagen
15. Documentation information and history
Project: HC 960
Type of document: Technical document
Version: 1.0
Prepared on: 27/02/2007
Prepared by: Mühlhausen
ehb electronics gmbh, Hanover
16.Revisions:
Version: Preparation/Revisions: Prep./Rev.
date:
Preparer/Re-
viser(s):
1.0 Consolidation DE, EN, IT 23/06/2006 Mü
1.1 Harting connector EN added 27/02/2007 Mü
1.1 Layout; adaptation of text pt. 13
20/01/15, 28/06/17
Hag
1.2 Adaptation of "Installation" notes for use 04/12/2017 Ak/hag
2.0 Revision for HC960 V2
Edited
20/03/2020,
25/03/2020
Hk
Hag
2.1 Pt. 2 “Meaning of Parameters”, adaption, copyedit 10.11.2020 Jäk/Hk/Hag
2.1 Pt. 9 – Amph.-Connector, drawing adapted 23.11.2020 Jäk/Hag
17. Legal information
Customer service:
Tel.
+49-511-123207-0
Fax
+49-511-123207-77
Email
Hans-Böckler-Straße 20
30851 Langenhagen - GERMANY
www.ehb-electronics.de
www.ehb-service.de
www.ehb-shop.de
Table of contents
Other ehb electronics Controllers manuals
Popular Controllers manuals by other brands

Baldor
Baldor Nextmove ESB installation manual

LITELINE
LITELINE OnCloud LC-CRTL-SCENE-1 user manual

Sinclair
Sinclair KJR-29B Operation manual

YORKVILLE
YORKVILLE Coliseum CV-1 manual

Full Gauge Controls
Full Gauge Controls MT-543e plus instruction manual

AMS Controls
AMS Controls XL100 BATTERY REPLACEMENT GUIDE

GCE druva
GCE druva PTLH0FT Instructions for use

TestEquity
TestEquity F4T user guide

Atkinson Electronics
Atkinson Electronics PVLC-40MD quick start guide

Emerson
Emerson Bettis RTS Service manual

Alpha Omega Instruments
Alpha Omega Instruments 800 Series instruction manual

Rodix
Rodix FEEDER CUBE VF-9-OF manual