40m20m
{
L2
A1
A2
A1+
A2-
+
+
R
Reed Switch Reed Switch
2K2 - 2W
D = 20 ~ 40m
22R 5W
R
220R 5W
Manual
C.01/Mar2018

Models for G 1/4” Port
FE Series
eicos.net
 |  | 
IMPORTANT !
YOU MUST CHECK BEFORE INSTALLATION

AC Current: Use K8*Filter in parallel with the coil (A1 A2) of a contactor or relay.
DC Current: Use KD*Filter in parallel with the coil (A1 A2) of a contactor or relay.
*For sale on accessories.eicos.us
Direct connection
to the sensor
Use 22R 5W*
resistor in series Use
24Vdc Voltage
• 
• 
Use mini contactor or auxiliary relay.
• ELECTRONIC EQUIPMENT:
 Use 4K7 10W resistor.
 Use 220R 5W* resistor.

 
Operation






•  require prior testing. Use
lter before the Sensor to prevent the internal piston from locking. Not
recommended for industrial water waste.
•       require technical
analysis: the Sensor contains magnetic components inside. Use a
magnetic lter before the Sensor to avoid deposition/settling that will
prejudice its operation.
The sensors work in all voltage and current ranges displayed in the table bellow:
Operating Voltage   Peak Current
110Vac 20VA 0,2A 0,5A @20ms
220Vac 20VA 0,1A 0,5A @20ms
5Vdc 2,5W 0,5A 1A @20ms
12Vdc 5W 0,5A 1A @20ms
24Vdc 10W 0,5A 1A @20ms
 NOT recommended

On datasheets.eicos.us available technical specications

02 (two) years warranty. 
All Sensors have been tested and approved during the manufacture process.

K8 Snubber Filter for
electrical installation (AC)
(included)

Filter
Installing the snubber
lter extends the
lifespan of the sensor’s
electrical contact.
K8 for AC
KD for DC
*On accessories.eicos.us check models and prices of Filters and Mini Contactor
 - Attention to Install
Note: Reed Switches have reached over one million operations in tests with
contactor and K8* snubber lter.

Reed Switches are hermetically sealed contacts
actuated by a magnetic eld.
The life expectancy of a reed switch refers to a
kind of load to be used. Reed Switches of the highest reliability are applied in
our sensors, and their life expectancy can reach above two million operations.
However, when they are switching lamps, inductive or capacitive loads, this
number may decrease.

It is important to consider that the power specied by an electrical load is
often referred to the permanent working state.
For higher power, use an auxiliary relay or contactor as recommended below,
or similar.
This resistor dampens the peak voltage caused by the
capacitance of cables and electronic equipment input.
due to CAPACITANCE, which
can occur depending on the distance and cable used in the connection to the contactor.
K8*Filter mounted in
parallel with the coil of an
AC contactor, increases the
contact life.
• Switching inductive loads
0.1µF 400V


• Connecting the sensor to a contactor in long distances, use resistor:
• Connecting the sensor to an electronic equipment:
Important: For installation with , use 4K7 10W resistor.
•Timing relay
•Frequency inverter
•Etc.
Flow Switches and Level Switches for liquids
KD*Filter mounted in
parallel with the coil of a
DC relay, increases the
contact life.
BY448
or
1N4007
Important: For distances , use 24Vdc voltage.
K8*
K8*
KD*



Initial: 31.7VA
Rated: 5.1VA
Contactor Contactor
.
53
26
49
13
98
32
Ø12
0
13
A-coding
FLOW INCREASE - ON
FLOW DECREASE - OFF 4LPM
Technical Specications
PPA (Polyphthalamide)
AISI 304 stainless steel
4mm2
25bar
0°C to 100°C | 140°C @1h
G 1/4” female (BSP - Parallel)
NBR (nitrilic rubber) O’Ring
M12 male plug (2 pins)
M12 female connector NOT included
IP66
Reed Switch 20W/VA (NA SPST)
80g
Body
Spring
Internal clearance
Maximum operating pressure
Operating temperature range
Inlet/outlet port
Sealing
Output connection
Enclosure rating
Electrical contact
Weight
Suitable for Detection of Low Flows
Fluid ow through the sensor triggers precise displacement of a magnetic piston acting on an electrical contact (Reed Switch).
Model Actuation Range (in LPM)
Water Oil 68 cSt @ 40°C
FE14B02-M12 From ~0,2 to ~3,0 From ~0,01 to ~0,21
FE14B04-M12 From ~0,4 to ~4,0 From ~0,01 to ~0,65
Installation
• In applications without excessive vibration;
• Minimum distance of 20mm from any ferrous surface;
• Mounting with parallel port connection and O’Ring.
Mounting
Dimensions in millimeters.
Sealing
O’Ring (NBR) for sealing
Parker code 6-061
(included)
GAS (BSP) Thread
The sealing is made on the ring.
It’s not necessary sealant tape or
over tightening
Flow Rate Sensitivity Adjustment
In water. Set point accuracy: ±15%.
Repeatability (not considering the viscosity change of liquids): ±10%.
Results of the
sensitivity test
(xed in the package)
Allen wrench to
adjust the sensitivity
(included)
Inlet Fitting
Outlet Fitting
Flow
Direction
Hex screw for sensitivity adjustment
WRONG
ASCENDING FLOW
Maintenance
1. Open the plug, remove the spring and clean using a brush if
there is encrustation;
2. Mount the sensor again as illustrated beside;
3. Test the electrical contact using an ohmmeter, moving the
magnetic piston.
M12 female
connector
Male M12 plug
2 pins
Flow
Switch
Electrical Connection
3-BL
1-BR
On datasheets.eicos.us available technical specications Flow Switches and Level Switches for liquids
Scale Body Piston Spring O’Ring Plug
Output plug
M12 plug

This manual suits for next models

1

Other eicos Switch manuals

eicos FH12B02-M12 User manual

eicos

eicos FH12B02-M12 User manual

eicos FC34B02-M12 User manual

eicos

eicos FC34B02-M12 User manual

Popular Switch manuals by other brands

FOR-A HVS-490 Operation manual

FOR-A

FOR-A HVS-490 Operation manual

One Remote 30017742 user manual

One Remote

One Remote 30017742 user manual

CoolGear CG-UC31PD4H product manual

CoolGear

CoolGear CG-UC31PD4H product manual

ZIMCO RS74A-750F Installation & operation manual

ZIMCO

ZIMCO RS74A-750F Installation & operation manual

G-Force Power Switch G0021 instruction manual

G-Force

G-Force Power Switch G0021 instruction manual

Black Box LGB5510A Management guide

Black Box

Black Box LGB5510A Management guide

FOR-A MFR-1000 Quick setup guide

FOR-A

FOR-A MFR-1000 Quick setup guide

Black Box ServSwitch KV0004A installation guide

Black Box

Black Box ServSwitch KV0004A installation guide

Tripp Lite B006-VUA4-K-R owner's manual

Tripp Lite

Tripp Lite B006-VUA4-K-R owner's manual

Ruby Tech GS-2148L Technical specifications

Ruby Tech

Ruby Tech GS-2148L Technical specifications

Black Box PSE508MA manual

Black Box

Black Box PSE508MA manual

Qlogic SANbox 3810 installation guide

Qlogic

Qlogic SANbox 3810 installation guide

Tripp Lite NetController B040-008-19 Guide de démarrage rapide

Tripp Lite

Tripp Lite NetController B040-008-19 Guide de démarrage rapide

Black Box SW1035A user manual

Black Box

Black Box SW1035A user manual

Tripp Lite C205-004-U-R user manual

Tripp Lite

Tripp Lite C205-004-U-R user manual

Ntron 508TX-N Specifications

Ntron

Ntron 508TX-N Specifications

Qlogic SilverStorm 9000 reference guide

Qlogic

Qlogic SilverStorm 9000 reference guide

AirLive SNMP-GSH2004L user manual

AirLive

AirLive SNMP-GSH2004L user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.