Ekars EES-2161 User manual

EES-2161
Public Address
Emergency Switcher
OPERATING MANUAL

Contents
1. Unpacking And Installation ------------------------------------------------------ 2
2. Features & Specifications --------------------------------------------------------- 3
3. Front Panel Controls --------------------------------------------------------------- 4
4. Rear Panel Controls --------------------------------------------------------------- 5
5. Connections ---------------------------------------------------------------------------- 6
1
SamHyoung Electronics Co., Ltd.
936-4, Kumuncheoun-Ri, Hyangnam-Myun,
Hwaseong-City, Kyunggi-Do, Korea (445-922)
Tel : 82)31+432+5112 / 82)31+432+4422
Fax : 82)31+352+7637 / 82)31+352+7649
Home Page : http://www.ekars.co.kr
http://www.samhyoung.co.kr

Unpacking And Installation
2
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
:
TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICICE PERSONNEL.
TO PREVENT FIRE OR SHOCK HAZARD,
WARNING
:
DO NOT EXPOSE THE UNIT TO RAIN OR
MOISTURE.
This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature
accompanying the appliance.
This symbol is intended to alert the user to the
presence of uninsulted "dangerous voltage"
with in the product's enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.
To prevent electric shock do not use this
(polarized) plug with an extension cord,
receptacle or other outlet unless the blades can
be fully inserted to prevent blade exposure.
:
CAUTION
Although it is neither complicated to install nor difficult to operate your Emergency
Switcher, a few minutes of your time is required to read manual for a properly wired
installation and becoming familiar with its many features and how to use them.
Please take a great care in unpacking your Emergency Switcher and do not discard
the carton and other packing materials.
They may be needed with when moving your set and are required if it ever becomes
necessary to return your set for service.
Never place the unit radiators, in front of heating vents, in excessively humid or dusty
location to avoid early damage and for your years of quality use.
Connect your complementary components as illustrated in the following page.
The instruction for use shall state that the apparatus shall not be exposed to dripping or
splashing and that no objects filled with liquids, such as vases, shall be placed on the
apparatus.

Features
AUTO FIRE SENSOR
The 16 fire sensors are connected via the terminal and the connector.
FIRE AND SPEAKER SWITCHING INDICATOR
You can notice the floor easily where takes fire and confirm the speaker relay control
by watching the indicators.
SPEAKER MANUAL CHANGEOVER ON EMERGENCY
You can control the speaker relay on emergency operating made by using
the speaker switch.
EXTENSION FUNCTION
To extend over sixteen layers, you need the next Emergency Switcher.
BASEMENT BROADCASTING
It is easy to link entire floor of fire alarm from the first basement floor
to the sixth basement floor.(For basement garage)
3
Specifications
Fire sensor -------------------------------------------------------------------------------------- 16 lines
Indicator (Fire& EM) -------------------------------------------------------------------------- 16 lines
Power Requirements ------------------------------------------------------------------------- DC24V
Power Consumption -------------------------------------------------------------------------- 2 Watts
Net Weight (kg/lb) ------------------------------------------------------------------------------ 2.8/6.2
Dimensions ------------------------------------------------------ 483(W) x 44.5(H) x 250(D) mm
Specifications and design are subjected to change without notice
for improvements.
* With support completely combined fire alarm to the first floor to sixth basement
floor applicant for basement garage.

Front Panel Controls
4
1. EMERGENCY ALL SWITCH
On EMERGENCY situation, you can broadcast by manual.
2. EMERGENCY ALL INDICATOR
This indicates the ALL switch turns on.
3. EMERGENCY SPEAKER SELECTOR
On EMERGNECY situation, you can broadcast the selected area by manual.
4. EMERGENCY SPEAKER INDICATOR
These indicate the EMERGENCY switches turn on.

Rear Panel Controls
5
1.2. DC 24V INPUT TERMINAL
This is a terminal for connecting to the Unswitched output terminal of
Power Distributor (EPS-3173).
3. EMERGENCY CONTROL OUTPUT CONNECTOR
This is for connecting to the Emergency Control Input connector of Matrix Logic
(EML-2161).
4. EMERGENCY SWITCHED INPUT CONNECTOR
This is for connecting to the Output Terminal of Fire Alarm System.
5. EMERGNECY SWITCHED INPUT TERMINAL
This is for connecting to the Output Terminal of Fire Alarm System.
6. EXTENSION INPUT & 7. EXTENSION OUTPUT CONNECTOR
You can extend circuits using these Connectors When you need more circuits.
DC INPUT EM CONTROL OUT FIRE ALARM IN
18
1
3
5
79
11
1315
17
24
6810
1214
16 18
1
3
5
79
11
1315
17
24
6810
1214
16 COM 15 13 11 97531
COM 2
16 14 12 10 8 6 4EXPANSION
OUT
24V FIRE
EM
18
17
COM
COM
18
17
FIRE ALARM IN
IN
CTRL-OUT
1~16
CTRL-IN
1~16
MADE IN KOREA
MADE IN KOREA
PUBLIC ADDRESS
PUBLIC ADDRESS
www.ekars.co.kr
EMERGENCY SWITCHER
EMERGENCY SWITCHER
POWER CONSUMPTION 2W
POWER CONSUMPTION 2W
MODEL NO : EES-2161
MODEL NO : EES-2161
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
OF FIRE OR ELECTRIC SHOCK
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
TO REDUCE THE RISKWARN ING
:
SN
123 4
567

Connections
6
DC INPUT EM CONTROL OUT FIRE ALARM IN
18
1
3
5
79
11
1315
17
24
6810
1214
16 18
1
3
5
79
11
1315
17
24
6810
1214
16 COM 15 13 11 97531
COM 216 14 12 10 8 6 4 EXPANSION
OUT
24V FIRE
EM
18
17
COM
COM
18
17
FIRE ALARM IN
IN
CTRL-OUT
1~16
CTRL-IN
1~16
MADE IN KOREA
MADE IN KOREA
PUBLIC ADDRESS
PUBLIC ADDRESS
www.ekars.co.kr
EMERGENCY SWITCHER
EMERGENCY SWITCHER
POWER CONSUMPTION 2W
POWER CONSUMPTION 2W
MODEL NO : EES-2161
MODEL NO : EES-2161
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
OF FIRE OR ELECTRIC SHOCK
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
TO REDUCE THE RISKWARNI NG
:
SN
CONTROL OUTPUT
B+
GND
18
17
CTRL-OUT
1~16
SPEAKER SELECTOR INPUT
B+
GND
18
17
CTRL-IN
1~16
RMT-2 INPUT
COM
ALL
18
17
EM CTRL INPUT
FIRE
EM
18
17
ATT CTRL
OUT
DC IN TIMER IN RMT OUT
POWER EXP IN EXP OUT
RMT-1 INPUT
COM
ALL
18
17
18
13
5
7911131517
246810121416 18
13
5
7911131517
246810121416 18
13
5
7911131517
246810121416 18
13
5
7911131517
246810121416 18
13
5
7911131517
246810121416 10
13
5
79
2468 10
13
5
79
2468
24V
MATRIX
LOGIC
MATRIX
LOGIC
CTRL-IN
1~16
CTRL-IN
1~16
CTRL-IN
1~16
REMOTE CONTROL
POWER
REMOTE IN
CHARGER
IN
SWITCHED
OUT
UNSWITCHED
OUT
BATTERY
24V DC INPUT
SWITCHED
24V DC OUT
(ONLY AMP)
SWITCHED
24V DC OUT
(ONLY AMP)
SWITCHED OUT(3000W MAX)
SWITCHED OUT(3000W MAX)
UNSWITCHED
OUT(750W MAX)
UNSWITCHED
OUT(750W MAX)
24V
24V
TO REDUCE THE RISK OF FIRE
TO REDUCE THE RISK OF FIRE
REPLACE ONLY WITH SAME TYPE FUSE.
CAUTION
:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
WARNING
:
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN KOREA
MADE IN KOREA
www.ekars.co.kr
PUBLIC ADDRESS
PUBLIC ADDRESS
POWER DISTRIBUTOR
POWER DISTRIBUTOR
MODEL NO : EPD-2083
MODEL NO : EPD-2083
POWER CONSUMPTION 135VA
POWER CONSUMPTION 135VA
SN
50/60Hz. 135VA
AC INPUT
220V-240V
DC INPUT EM CONTROL OUT FIRE ALARM IN
18
1
3579
11
1315
17
24
6810
1214
16 18
1
3579
11
1315
17
24
6810
1214
16 COM 15 13 11 97531
COM 216 14 12 10 8 6 4 EXPANSION
OUT
24V FIRE
EM
18
17
COM
COM
18
17
FIRE ALARM IN
IN
CTRL-OUT
1~16
CTRL-IN
1~16
MADE IN KOREA
MADE IN KOREA
PUBLIC ADDRESS
PUBLIC ADDRESS
www.ekars.co.kr
EMERGENCY SWITCHER
EMERGENCY SWITCHER
POWER CONSUMPTION 2W
POWER CONSUMPTION 2W
MODEL NO : EES-2161
MODEL NO : EES-2161
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
OF FIRE OR ELECTRIC SHOCK
DON'T EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
TO REDUCE THE RISKWARNI NG
:
SN
EMERGENCY
SWITCHER
EES-2161
FIRE ALARM
MATRIX LOGIC
EML-2161
POWER
DISTRIBUTOR
EPD-2083
EMERGENCY
SWITCHER
EES-2161

Block Diagram
7
EXPANSION
OUT IN
FIRE ALARM IN
COM
COM
18
17
CTRL-IN
1~16
EM CONTROL OUT
18
1357911131517
246810121416
18
1357911131517
246810121416
FIRE
EM
18
17
CTRL-OUT
1~16
ALL LED
ALL
12345 16
ALL
COM15131197531
COM 2
16 14 12 10 8 6 4
FIRE ALARM IN
1
2
3
4
5
16
1
2
3
4
5
16
17
18
12345 16
DC INPUT
24V
COM
LED

3rd floor, 271-183, Kochk-2Dong,
Guro-Gu, Seoul, Korea (152-082)
Tel : 82)2+2612+4422
Fax : 82)2+2612+7676
Seoul office.
936-4, Kumuncheoun-Ri, Hyangnam-Myun,
Hwaseong-City, Kyunggi-Do, Korea (445-922)
Tel : 82)31+432+5112 / 82)31+432+4422
Fax : 82)31+352+7637 / 82)31+352+7649
Home Page : http://www.ekars.co.kr / http://www.samhyoung.co.kr
Headquarter & Overseas Dep.
MEMO
PUBLIC ADDRESS TOTAL SOLUTION
Table of contents
Popular Switch manuals by other brands

INNOVATIVE CIRCUIT TECHNOLOGY
INNOVATIVE CIRCUIT TECHNOLOGY ICT200-LVD instruction manual

GRASS VALLEY
GRASS VALLEY zodiak Installation and service manual

Cisco
Cisco 3020 - Cisco Catalyst Blade Switch Command reference

SOARNEX
SOARNEX EP120 Series Quick installation guide

IPGARD
IPGARD DPMST-4S-P quick start guide

United Electric Controls
United Electric Controls J21K Installation and maintenance instructions