1
Device with interface function between a KNX network
(TP, twisted pair) and home speakers equipped with Ama-
zon Alexa or Google Assistant. The interface, connected
to ekinex cloud services, is suitable for the control by voi-
ce commands of light, climate and motorization of a mo-
dern KNX standard building.
Technical Sheet: STEKBW1TP_EN
• 2 frontal LEDs: POWER LED for signalling the presen-
ce of power supply; SERVICE LED for signalling parti-
cular operations in progress.
• 1 RESET button housed under the front cover on the
back of the vertical card
• 1 RS485 port: not used
• 1 USB 2.0 port: not used
Other features:
• Plastic housing
• Design for mounting on 35 mm prole rail (according
to EN 60715)
• Degree of protection IP20 with product installed (accor-
ding to EN 60529)
• Insulation class II (according to EN 60335-1)
• Climatic classication 3K5 (indoor, dry) and mechanical
3M2 (according to EN50491-2)
• Device weight: 120 g
• 2 UM modular device (1 UM = 18 mm)
• Dimensions 36 x 90.5 x 62 mm (W x H x D)
Environmental conditions:
• Operating temperature: 0°C ... + 40°C
• Storage temperature: - 10 ... + 70°C
• Transport temperature: - 10 ... + 70°C
• Relative humidity: 95% not-condensing
Operating, signaling and connection elements
The voice control interface is equipped with status LEDs,
a RESET button located under the front panel of the devi-
ce, terminals for power supply connection, KNX bus line
and Ethernet network.
KNX voice control interface
Code: EK-BW1-TP
Description
The product is designed for installation on DIN prole rail
and occupies 2 modules. The 12-24 Vdc power supply is
external (power supply not included in the supply). The
product with hardware based on embedded operating sy-
stem, has a KNX TP node (twisted pair) and can therefore
be connected directly to the bus network of KNX devices.
The external connectivity is realized through the Ethernet
port that connects the device directly to the home router.
The integrated web server provides access to the congu-
ration environment and provides the following functions:
• Interface network settings
• Registration and subscription to ekinex cloud services
• Automatic import of the ETS project and merging with
previous imports
• Conguration of voice control accessories (max 150
accessories): lighting (on/o󰀨, dimmed and RGB), mo-
torizations (open/close stop and position) and climate
• Conguration of action sequences on the KNX bus,
which can be called up as scenarios by voice assistants
• Conguration of the IFTTT (If This Than That) cloud
platform for the creation of association rules between
events on the KNX bus and compatible services (e.g.
sending e-mail)
On the Amazon Alexa and Google Assistant apps, the
Ekinex skill and action are available respectively for the
complete conguration of the service.
Main features
• 12-24 Vdc power supply (absorption 240 mA at 12 Vdc)
by means of a special plug-in terminal supplied. Power
supply not included
• KNX TP bus (twisted pair) via red-black terminal pro-
vided
• 1 Ethernet port via cat. 5 or higher cable and standard
RJ45 connector
EK-BW1-TP
Voice control
6
4
5
3
1
2
1. LED POWER
2. LED SERVICE
3. RESET push-button
4. Clamp for power-supply 12-24 Vdc
5. Clamp for KNX bus
6. RJ45 Ethernet plug
Signaling elements
• POWER LED: indicates the presence of 12-24 Vdc po-
wer supply at terminals
• SERVICE LED: Normally o󰀨, steady mode or ashing
during IP address recovery sequences or factory re-
congurations
Control elements
• RESET button: must be pressed to activate IP address
reset sequences or factory settings.
2
!
!
i
Before removing the device, be sure the inputs have been
disconnected and the bus terminal has been extracted
from its slot. Use a screwdriver to slide down the locking
device and remove the device from the rail.
i
Warning! The electrical connection of the device may only be
carried out by qualied personnel.
Connection to the KNX bus network
The connection to the bus network is made via the KNX
terminal included in the scope of delivery and inserted
into the housing on the front of the device at the bottom.
KNX clamp characteristics
• Spring clamping of the conductors
• 4 conductor seats for each polarity
• Suitable for KNX bus cable with single conductors
between 0.6 and 0.8 mm diameter
• Recommended conductor stripping approx. 5 mm
• Colour coding: red = bus conductor + (positive), black =
bus conductor - (negative)
Conguration and commissioning
The conguration and commissioning of the voice con-
trol interface must be carried out by accessing the web
server integrated in the product. These activities must be
carried out in accordance with the design of the building
automation system carried out by a qualied professio-
nal.
EK-BW1-TP
Voice control
EK-BW1-TP
Voice control
bus KNX
Note. The RESET button is not directly accessible on the front
panel of the product. To access the button, open the front panel
of the delégo server using a small slotted screwdriver and exer-
ting a slight leverage eect in one of the side slots. Locate the
RESET button on the back of the vertical board at the bottom of
the device towards the KNX terminals.
Mounting
The device has degree of protection IP20, and is there-
fore suitable for use in dry interior rooms. The housing is
made for rail mounting according to EN 60715 in boards
or cabinets for electrical distribution. The installation is in
horizontal position, the correct position is when the KNX
bus terminal is located at the bottom and the terminals for
the outputs are located at the top.
For the installation of the device on the rail proceed as
follows:
• with the aid of a tool bring the locking device in the fully
lowered position (1);
• place the upper edge of the rear inner prole on the
upper edge of the rail (2);
• rotate the device towards the rail (3);
• push the locking device upward until it stops (4).
Note. It is recommended that the installation of the device
always ensure the full accessibility of the front side to allow the
led visualization.
Power 12-24 Vdc
The connection to the power supply is made via the
screw terminals (1)+ and (2)- located on the removable
2-pin connector.
Clamp characteristics
• Screw tightening of conductors
• Max. conductor cross-section 2.5 mm2
• Recommended conductor stripping approx. 6 mm
• Max. torque 0.5 Nm
Warning! Only use KNX bus power supplies (e.g. ekinex EK-
AB1-TP or EK-AG1-TP) to supply the KNX bus lines. The use
of other power supply devices can impair communication and
damage the devices connected to the bus.
3
!
i
i
Restore factory conguration
If the conguration made makes it impossible to access
the server delégo or its correct use, it is possible to re-
store the factory conditions, resetting the IP address and
emptying the supervision project using the “RESET” but-
ton available. In this case, compared to what was pre-
viously seen to restore the IP address, the procedure to
follow is the following:
• open the front panel of the device using a small slotted
screwdriver, and exerting a slight leverage e󰀨ect in one
of the side slots
• locate the RESET button on the back of the vertical
card
• Press the RESET button for at least 10 seconds un-
til the SERVICE LED on the front of the device starts
ashing, then release the button.
• within the next 5 seconds, press and hold the button for
at least 10 seconds
• When the LED is solidly lit, release the button and wait
for it to go out.
• when the LED goes o󰀨, remove and restore the power
supply
• Wait about one minute and log in to the server with the
factory IP address (192.168.0.110).
Network connection
The conguration and use of the voice control interface
requires a connection to the home or company network.
The default IP address of the interface is: 192.168.0.110.
For the initial conguration of the interface, as well as in
case of absence of a network during the installation pha-
se, it is necessary to proceed as follows:
1. connect the interface to your PC via a “cross over” (or
“crossover”) network cable
2. access your PC’s network settings, as illustrated in
your operating system documentation
3. Change the TCP/IP communication protocol settings
(version 4) for the LAN port of your PC, and set the
following parameters manually:
• IP address: 192.16 8.0.100
• Network mask: 255.255.255.0
• Default gateway: 192.168.0.110
• Save and wait for the new settings to take e󰀨ect. If
prompted, reboot the system.
After these operations, open an Internet browser and
type in the address bar:
http://192.168.0.110
Note! For an optimal browsing experience, we recommend using
one of the following browsers:
• Google Chrome
• Apple Safari
First access
When you open the browser at the default address, the
login screen is displayed:
the voice control interface has the following preset user
at the factory:
Warning! To avoid losing all the congurations made for the au-
tomation project during a factory reset operation, it is recommen-
ded to make periodic backups of the supervision project.
User Password
admin admin
Enter the credentials of the user “admin” and conrm to
access the main screen of the voice interface administra-
tion environment.
Restore factory IP address
If necessary, you can restore the factory IP address of the
voice interface using the RESET button available. Follow
the procedure below:
• open the front panel of the device using a small slotted
screwdriver, and exerting a slight leverage e󰀨ect in one
of the side slots
• locate the RESET button on the back of the vertical
card
• Press the button for at least 10 seconds until the SER-
VICE LED on the front of the device starts ashing,
then release the button.
• within the next 5 seconds, press and release the button
for 1 second; within a couple of seconds the front LED
will light up solidly for a couple of seconds
• When the LED goes out, the device can be reached at
the factory IP address (192.168.0.110).
If the LED goes out after long press (10 seconds) before
short press, repeat the whole procedure. This procedure
resets the IP address and retains all data relating to the
conguration previously carried out on the automation sy-
stem.
The conguration and commissioning activities of the KNX voice
control interface require specialized skills on the KNX network
and knowledge of the specic automation project carried out with
ETS. To acquire these skills, it is essential to participate in the
courses organized at KNX certied training centers. For further
information: www.knx.it
Dimensions [mm]
EK-BW1-TP
Voice control
36
90,5
Approvals
• CE the products complie with the Low Voltage Directive
(2014/35 / EU) and the Electromagnetic Compatibility
Directive (2014/30 / EU). Tests carried out in accordan-
ce with EN 50491-5-1: 2010, EN 50491-5-2: 2010.
Maintenance
The devices are maintenance-free. To clean them, use
a dry cloth. The use of solvents or other aggressive sub-
stances is absolutely to be avoided.
4
!
Warnings
• Installation, electrical connection, conguration and
commissioning of the device may only be carried out
by qualied personnel in accordance with the applica-
ble technical regulations and the laws in force in the
respective countries.
• The device may not be used in safety applications. Ho-
wever, the device may be used for auxiliary signalling
functions.
• Opening the housing of the device results in the imme-
diate interruption of the warranty period.
• In the event of tampering, compliance with the essential
requirements of the applicable directives for which the
device has been certied is no longer guaranteed.
• Defective ekinex® KNX devices must be returned to the
manufacturer at the following address: Ekinex S.p.A.,
Via Novara 37 - I-28010 Vaprio d’Agogna NO
Other useful informations
• This technical data sheet is addressed to installers, sy-
stem integrators and designers
• For more information on the product, you can contact
ekinex® technical support at the e-mail address: sup-
[email protected] or consult the website www.ekinex.
com
• Each ekinex® device has a unique serial number on
the label. The serial number can be used by installers
and system integrators for documentation purposes
and must be added to any communication addressed
to ekinex® technical support in case of equipment mal-
function.
• ekinex® is a registered trademark of Ekinex S.p.A.
• KNX® ed ETS® sono marchi registrati da KNX Asso-
ciation cvba, Bruxelles
© Ekinex S.p.A. 2020. The company reserves the right to make
changes to this technical documentation without notice.
File Name Device
Release Update
STEKBW1TP_EN.pdf A1.0 09 / 2020
The products described in this technical sheet at the end
of its useful life are classied as waste from electronic
equipment according to the European Directive 2012/19
/ EU (RAEE recast), implemented in Italy with Legislative
Decree no. 49 of 14 March 2014, and cannot be transfer-
red to unsorted municipal solid waste.
Important! Incorrect disposal of the product can cause serious
damage to the environment and human health. For correct di-
sposal, inquire about the collection and treatment methods pro-
vided by the local authorities.
Document
This technical sheet refers to the A1.0 release of
ekinex® devices cod. EK-BW1-TP and is available for
download on the website www.ekinex.com in PDF (Por-
table Data Format) format.
Disposal

Other Ekinex Home Automation manuals

Ekinex EK-GD2-DL-1-LV User manual

Ekinex

Ekinex EK-GD2-DL-1-LV User manual

Ekinex EK-VA2-WL Series User manual

Ekinex

Ekinex EK-VA2-WL Series User manual

Ekinex Delego Panel 10 Smart User manual

Ekinex

Ekinex Delego Panel 10 Smart User manual

Popular Home Automation manuals by other brands

Berker 101089 Series Assembly instructions

Berker

Berker 101089 Series Assembly instructions

Hitachi CH-UNIT Installation and operation manual

Hitachi

Hitachi CH-UNIT Installation and operation manual

Hama Mini operating instructions

Hama

Hama Mini operating instructions

Comm Net Systems Matrix 016-131-10 Setup and operation manual

Comm Net Systems

Comm Net Systems Matrix 016-131-10 Setup and operation manual

Lutron Electronics RadioRA2 RRD-H2RLD installation instructions

Lutron Electronics

Lutron Electronics RadioRA2 RRD-H2RLD installation instructions

ORVIBO W40CZ user manual

ORVIBO

ORVIBO W40CZ user manual

LEGRAND GFCI Installing and Testing

LEGRAND

LEGRAND GFCI Installing and Testing

SOMFY TaHoma Installation and user guide

SOMFY

SOMFY TaHoma Installation and user guide

DOM Tronic Mifare Assembly

DOM

DOM Tronic Mifare Assembly

SOMFY LT80 H SEL quick start guide

SOMFY

SOMFY LT80 H SEL quick start guide

Open House H560 installation manual

Open House

Open House H560 installation manual

Tynetec Altec 169MHz installation guide

Tynetec

Tynetec Altec 169MHz installation guide

TimeTec SMART SCENARIO PANEL user guide

TimeTec

TimeTec SMART SCENARIO PANEL user guide

Essence Care@Home Pro System installation guide

Essence

Essence Care@Home Pro System installation guide

Dornbracht Smart Set manual

Dornbracht

Dornbracht Smart Set manual

Gira System 3000 2460 00 operating instructions

Gira

Gira System 3000 2460 00 operating instructions

Mirabella International Genio quick start guide

Mirabella International

Mirabella International Genio quick start guide

Leviton WSG15-0DZ quick start guide

Leviton

Leviton WSG15-0DZ quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.