Eldes ESIM120 User manual

GSM SWITCH GATE CONTROLLER
ESIM120

Copyright ©“ELDES UAB”, 2011. All rights reserved
It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from
“ELDES UAB”. “ELDES UAB”reserves the right to update or modify this document and/or related products without a warning. Hereby, ELDES UAB
declares that this GSM Switch -Gate controller ESIM120 is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt.
User Manual v1.0
Safety instructions
Please read and follow these safety guidelines and assembly instructions in order to maintain safety of operators and people around:
• GSMcontrolsystemESIM120(furtherreferencedasthesystemordevice)containsanintegratedradiotransceiveroperatingin
GSM 850/900/1800/1900 MHz bands.
DO NOT use the system where it can interfere with other devices and cause any potential danger.
• DONOTmountthesystemnexttomedicalequipmentordevices,iftheyrequireso.
• DONOTusethesysteminhazardousenvironment.
• DONOTexposethesystemtohighhumidity,chemicalenvironmentormechanicalimpacts.
• DONOTattempttopersonallyrepairthesystem.
• Systemlabelisonthebottomsideofthedevice.
System ESIM120 is a device mounted in limited access areas. Any system repairs must be done only by qualied, safety aware
personnel.
Mains power must be disconnected before any installation or tuning work starts. The system installation or maintenance
must not be done during stormy conditions.
The system must be powered by main 10-24V 50Hz ~200mA AC or 10-24V 200mA DC power supply which must be
approved by LST EN 60950-1 standard and be easily accessible nearby the device. When connecting the power supply to the
system, switching the terminals places does not have any aect.
AnyadditionaldeviceslinkedtothesystemESIM120(computer,sensors,relaysetc.)mustbeapprovedbyLSTEN60950-1
standard.
External power supply can be connected to AC mains only inside
installation room with automatic 2-pole circuit breaker capable of
disconnecting circuit in the event of short circuit or over-current
condition. Open circuit breaker must have a gap between con-
nections of more than 3mm and the disconnection current 5A.
FuseF1modelMINISMDC050F0.5A.Blownfusecannotbereplacedbytheuserandthereplacementfuseshavetobeexactlythe
same as indicated by the manufacturer.
Thedeviceisfullyturnedobydisconnecting2-poleswitchodeviceoftheexternalpowersupplyoranyotherlinked
device that the system ESIM120 is powered from.
TheWEEE (WasteElectrical andElectronicEquipment)markingon thisproductor its documentationindicatesthatinthe EUthe
product must not be disposed of together with household waste.
Phase
AC 230V
50 Hz/DC 24V
USB cable
Null
ESIM120
PE
AC/DC
If you use I security class computer for setting the parameters it must be connected to earth.

Limited Liability
The buyer must agree that the system will re-
duce the risk of re, theft, burglary or other dan-
gers but does not guarantee against such events.
“ELDES UAB” will not take any responsibility
regarding personal, property or revenue loss while
using the system.
“ELDES UAB” responsibility according to local
lawsdoesnotexceedvalueofthepurchasedsys-
tem.
“ELDES UAB” is not aliated with GSM opera-
tors providing cellular services therefore is not res-
ponsible for the quality of cellular services.
Manufacturer Warranty
The system carries a 24-month warranty by the
manufacturer “ELDES UAB”.
Warranty period starts from the day the system
has been purchased by the end user. The warranty
is valid only if the system has been used as inten-
ded, following all guidelines listed in the manual
and within specied operating conditions. Receipt
with purchase date must be kept as a proof.
The warranty is voided if the system has been
exposed to mechanical impacts, chemicals, high
humidity, uids, corrosive and hazardous environ-
ment or other force majeure factors.
Content:
1. The system ESIM120 ............................................1pcs
2. ESIM120 user manual..........................................1pcs
3. GSM antenna.................................... .....................1pcs
About User Manual
This document describes GSM switch - gate controller ESIM120, its operation and installation.
It is very important to read User Manual before start using the system. A quick start guide is located in rst two chapters. Chap-
ter 3 describes additional system capabilities.
CONTENT
1. General Information......................................................... 4
1.1 Function..................................................................................................................4
1.2 Operation Description.......................................................................................4
1.3 Technical Specications ....................................................................................4
1.4 Connector and LED Indicators Functionality ...........................................5
1.5 Connection Circuit..............................................................................................5
1.6 System Installation..............................................................................................5
2. System Pre-operation, Control & Conguration............6
2.1 System Language................................................................................................6
2.2 SMS Password.......................................................................................................7
2.3 Administrator Phone Numbers ......................................................................7
2.4 Date & Time Settings..........................................................................................8
2.5 User Database Management...........................................................................9
2.6 Scheduler Settings...........................................................................................15
2.7 Output Conguration.....................................................................................16
2.8 Input & Output Status..................................................................................... 18
2.9 Input Conguration.........................................................................................18
2.10 Info SMS.............................................................................................................19
2.11 Conrmation by Call upon Output Control Action ...........................20
2.12 Control from any Phone Number.............................................................21
2.13 Event Log Deletion........................................................................................22
2.14 System Restart ................................................................................................22
3. Appendix.........................................................................23
3.1 Restoring Default Parameters...................................................................... 23
3.2 Eldes Conguration Tool software ...............................................................23
3.3 ESIM120 control by GPRS .............................................................................. 23
3.4 Technical Support............................................................................................. 26

4
1. General Information
1.1 Function
ESIM120 is a micro-controller based 2-relay device intended to control gate automatics, road barriers or to remotely turn on/o
any electronic device over GSM network.
Examples of using the system:
• Roadbarriercontrolintheparkinglotofresidentialhousesoroces
• Controllinggatesofprivatehouses
• Electronicappliancecontrolforaspeciedperiod.E.g.,turnon/oaquariumlighting,pump,watering,heatingetc.
• Turnoncomputersystem
• Turnon/oanyelectricappliance
• ”Frozen“systemreboote.g.computernetwork,server
• Noticationaboutafaultingateorotherautomatics.
1.2 Operation Description
System ESIM120 operates over GSM network. Gates are opened or any other electric appliance is turned on/o by making a phone
call to the system. The phone call is automatically rejected by the system, therefore the phone call becomes free of charge.
On calling to the phone number of the system it checks whether the caller is one of the administrators or stored in the user da-
tabase.Iftheuserisstoredinthesystem,thespeciedoutput(-s)foraparticularuseristurnedon/oforaspeciedperiod.The
system will ignore incoming requests from an unknown telephone number or SMS message containing wrong password.
By connecting the opened-gate/barrier sensor to one of the 3 inputs, the administrators can receive SMS message about the gates
that did not close during the set time period.
Thereare3waysofconguration:SMSmessages,overUSBcableorInternet(deviceconnectoverGPRS).
1.3 Technical Specications
Electrical, mechanical and other specications
Supply voltage 10-24V50Hz~200mAmax/10-24V 200mAmax
Current used in standby model not more than 50mA
GSM modem frequency 850/900/1800/1900 MHz
Number of outputs 2
Output type NO(relay)
Numberof“low”level(negative)inputs 2
Numberof“high”level(positive)inputs 1
Allowable“low”level(negative)inputvalues Voltage: 0... 16V; current: -0.8... -0.4mA
Allowable“high”level(positive)inputvalues Voltage: 5... 50V; current: 0.17 .... 1.7mA
Relayoutputmaximumcommutatingvalues 24V 1A / 24V 50Hz ~0,5A
Dimensions 70x85x57mm
Operating temperature range -20…+55oC(-30...+55oCwithlimitations)
Number of administrators 5
Number of users 500(1000optional)

MANUAL ELDES ESIM120 V1.0 5
1.4 Connector and LED Indicators Functionality
1.5 Connection Circuit
1.6 System Installation
The system can be installed only in a metal or non-ammable plastic enclosure. If the metal enclosure and transformer is used it
isnecessarytogroundtheenclosureusingyellow/greencolourcable.Fortheconnectionof230Vtransformeruse3x0.75mm2
1 thread double isolated cable. The primary circuit of the transformer must be connected through 0.5A fuse. 230V power supply
cables cannot be grouped with low voltage cable group. For the connection of power supply and output connectors use 1 thread
2x0.75mm2cable. For the connection of input/output connectors use 0.50 mm21 thread cable.
1. PlaceSIMcardintheholderbutmakesurethatSIMcardPINcodeisdisabled(PINcodecanbedisabledbyputtingSIMcard
intomobilephoneandfollowingpropermenus).SIMcardshouldnothaveanyremainingSMSmessages.
2. Connect the circuit as shown in g. No 2. Connect control connectors of the gate automatics device to the relay contacts. The
systems that are already installed most often contain a button for opening the gates.The relay can be connected instead of the
button or in parallel with its contacts.
3. Connect a sensor or switch to inputs Z1-Z3 that turns on only when gates are lifted. Low level signal is connected to Z1 and Z3.
HighlevelsignalisconnectedtoZ2.(Inputconnectionisanadditionalfunctionanditisnotnecessarytoinstall).
4. The system will start in less than a minute. LED2 indicator should be blinking or be ON indicating connection to GSM.
Short explanation of the main units
GSM MODEM GSM network 850/900/1800/1900 MHz modem
SIM CARD SIM card
LED Light-emitting diodes indicator
DEFAULT Connectors(D1andD2)forrestoringdefaultsettings
ANT GSM antenna SMA type connector
USB Mini USB connector
F1 Fuse
Connector functionality
Labeling Explanation
AC/DC Power supply pins
RELAY1 Dryrelaycontact.Normallyopen(NO)
RELAY2 Dryrelaycontact.Normallyopen(NO)
COM Common pin
Z5 Not Connected
Z4 Not Connected
Z3 “Low” level input Z3
Z2 “High”level input Z2
Z1 “Low” level input Z1
Fig. No. 1
ANT
GSM
MODEM
SIM
CARD
MIC
LED1
LED2
DEFAULT D1 D2
AC/DC RELAY1 RELAY2 COM Z5 Z4 Z3 Z2 Z1
USB
F1
ESIM 120
AC/DC
Power
supply
Gate controller Gate controller
RELAY1 RELAY2
+
-
COM Z3 Z2 Z1
Fig. No. 2
NOTE
Althoughthe installationofsystemESIM120 isnotcomplex,wehighly
recommend installing the device only in the case if you have minimal
electrotechnical or electronics knowledge. Otherwise you can damage
the device.
LED indicators functionality
LED1 Indicates SIM card
status
LED2 Indicates network
status
LED1 status Meaning
OFF SIM card is wor-
king properly
ON SIM card
error
LED2 status Meaning
OFF No network connection
Blinking 1 times per second Poor network connection
Blinking 3 time per second Medium network connection
ON Excellentnetworkconnection

6
2. System Pre-operation, Control & Conguration
VERY IMPORTANT!!!
In this user manual the underscore symbol ”_” represents one <space> character. Every underscore symbol must be replaced
by a single <space> character. There must be no spaces or other unnecesary characters at the beginning and at the end of the
message.XXXX–4-digitSMSpassword(thedefaultSMSpasswordis0000–fourzeros).
For easier and quicker conguration we recommend connecting the system to personal computer via USB cable and installing congura-
tion program ELDES Conguration Tool. Please, refer to chapter 3.2. for more details
The system can also be congured remotely by connecting over GPRS connection. Please, refer to chapter 3.3 for more details.
System conguration and control using SMS messages is performed by sending it to ESIM120 phone number from one of the
authorizedphonenumbers.ThestructureofSMSmessageconsistsof4digitSMSpassword(thedefaultSMSpasswordis0000–four
zeros),theparameterandvalue.Forsomeparametersthevaluedoesnotapply,i.e.STATUS.
Primary Conguration:
1. Set the system language. Please, refer to chapter 2.1 for more details.
2. Once the SMS reply conrming the successful language setup is received, proceed to chapter 2.2
3. Otherwise check the GSM network connection of the system by making a call to the system from any mobile phone. The
SMS reply asking to change the password conrms that GSM signal present.
4. In other case, change the SMS centre phone number.
SMS centre number is stored in SIM card by the GSM operator, therefore if SIM card has already
been successfully used to send SMS messages over a mobile phone, then it is not necessary
to change SMS centre number.
In order to change/enter SMS centre number send the following SMS message to the system.
Language in which the system communicates with the user by SMS messages. The language
must be set before changing factory default SMS password, therefore SMS password is not
required in the following SMS message.
SMS Centre
Phone Number
Set Language
SMS text:
0000_SMS_+37011111111
Example: 0000_SMS_+37069899992
SMS text:
LL
Value: LL – language index, range – [LT - Lithuanian, RU - Rus-
sian, EN - English, EE - Estonian]
Example: EN
2.1 System Language

MANUAL ELDES ESIM120 V1.0 7
AllSMScommandsstartwitha4-digitpassword.Manufacturerdefaultpasswordis0000(four
zeros),whichisnecessarytochange.Non-numericalcharacterslikeletters,dots,colons,spa-
ces are not allowed.
The system supports up to 5 administrator phone number entries allowing full system con-
gurationandcontrol(includingoutputcontrol).User1phonenumberismandatorywhile
other phone number entries are not necessary. All numbers must be entered starting with
international country code e.g. 44[area code][local number]. The plus symbol is not necessary.
Phone number length – up to 15 digits.
To receive the list containing added administrator numbers send the following SMS message.
Set SMS Password
Add Administrator
Numbers
List Administrator
Numbers
SMS text:
0000_PSW_XXXX
Value: XXXX – new 4-digit SMS password
Example: 0000_PSW_1111
SMS text:
XXXX_NR1:37011111111_NR2:37011111112_
NR3:37011111113_NR4:37011111114_NR5:37011111115
Example: 1111_NR1:37011111111_NR3_37011111113
SMS text:
XXXX_HELPNR
Example: 1111_HELPNR
2.2 SMS Password
2.3 Administrator Phone Numbers

8
This SMS message erases a particular or several administrator phone numbers at once. The
system will not allow erasing of the User 1 phone number. This number can only be modied.
Delete Administrator
Numbers
SMS text:
XXXX_NR2:DEL_NR3:DEL_NR4:DEL_NR5:DEL
Example: 1111_NR4:DEL_NR5:DEL
It is important to set correct date and time so that the system can send reports at specied
times.
Date and time can be set by sending the following SMS message.
Date & Time
SMS text:
XXXX_YYYY.MM.DD_HH:MM
Value: YYYY– year; MM – month, range – [01... 12]; DD – day,
range - [01... 31]; HH – hours, range – [00... 23], MM – minutes,
range – [00... 59].
Example: 1111_2011.12.01_14:15
2.4 Date & Time Settings

MANUAL ELDES ESIM120 V1.0 9
Thesystemsupportsupto500dierentdatabaseusers(1000optional)whichgainaccessto
controltheoutputs(gatesoranyotherelectricapplianceconnectedtotheoutput)bymaking
phone call to the system.
Userentryinthedatabaseconsistsofphonenumber(mandatory),username(notmandato-
ry)andadditionalparameters.
All user numbers must be entered starting with international country code e.g. 44[area code]
[local number]. The plus symbol is not necessary. Phone number length – up to 15 digits.
Length of user name - up to 16 characters.
To receive the list containing added database users send the following SMS message.
Add User
List Users
SMS text:
XXXX_N:37011111111:UserName
Example: 1111_N:37011111111:UserName1_N:37011111112_
N:37011111113:UserName2
SMS text:
XXXX_GETALLNUMBERS
Example: 1111_GETALLNUMBERS
2.5 User Database Management
NOTE:Databaseuserscanbemanagedbyadministrator(-s)only.
NOTE: Afteraddingall500users(1000optional)tothedatabasethesystemwillnotallowtoaddanymoreusers.Inordertoadd
a dierent user, please, delete one or more current database users.
ATTENTION:Depending on entered user numbers and/or user names you might receive more than 55 SMS messages!

10
This feature allows to erase a particular user or several users from the database. It is possible to
deleteauser(-s)byusernameorbyphonenumber.
Thisfeatureallowstoeraseallusersfromthedatabase(nottheadministratornumbers)at
once.
This feature allows to search for a user in the database. It is possible to search for user by user
name or by phone number.
Delete User (-s)
Delete All Users
Search for User
SMS text:
XXXX_D:37011111111 or XXXX_D:UserName
Example: 1111_D:37011111111_UserName2_UserName3
SMS text:
XXXX_D:ALL
Example: 1111_D:ALL
SMS text:
XXXX_T:37011111111 or XXXX_T:UserName
Example: 1111_T:UserName1
NOTE: Only one user name/phone number can be searched at a time.

MANUAL ELDES ESIM120 V1.0 11
Thesystemallowstodisableuserdatabaseinordertodenyoutput(-s)controlevenbyusers
stored in the database. In order to do this, send the following SMS message. By default user
database is enabled.
In order to enable user database, send the following SMS message
The user database allows to assign output C1, output C2 or both outputs to a particular user
whowillbeabletocontroltheoutput(-s).Itispossibletoassignbyusernameorbyphone
number.
Disable User
Database
Enable User
Database
Assign Output
(-s) to User
SMS text:
XXXX_DBM_OFF
Example: 1111_DBM_OFF
SMS text:
XXXX_DBM_ON
Example: 1111_DBM_ON
SMS text:
XXXX_OUTPUT_37011111111_X or XXXX_OUTPUT_UserName_X
Value: X – output (-s), range – [1 – C1 output, 2– C2 output, 3– both
outputs]
Example: 1111_OUTPUT:UserName1_3

12
Thisfeatureallowstocheckwhichoutput(-s)isassignedtoaparticularuserinthedatabase.
It is possible to check by user name or by phone number.
Ring Counter feature sets the user validity limit according to the quantity of allowed phone
calls to the system. After the set quantity of phone calls is depleted, the user is deleted from
the database. It is possible to set the ring counter by user name or by phone number.
This feature sets the user validity limit according to the deadline by a particular date and time.
After the set date and time comes, the user is deleted from the database. It is possible to set
theexpirydate&timebyusernameorbyphonenumber.
Check Assigned
Output
Set Ring Counter
Set Expiry
Date & Time
SMS text:
XXXX_OUTPUT_37011111111_? or XXXX_OUTPUT_UserName_?
Example: 1111_OUTPUT_37011111111_?
SMS text:
XXXX_RCOUNT_37011111111_? or XXXX_RCOUNT_UserName_?
Example: 1111_RCOUNT_:UserName1_?
SMS text:
XXXX_EXPIRYTIME_37011111111_YYYY.MM.DD_HH:MM or
XXXX_EXPIRYTIME_UserName_YYYY.MM.DD_HH:MM
Value: YYYY– year; MM – month, range – [01... 12]; DD – day, range -
[01... 31]; HH – hours, range – [00... 23], MM – minutes, range – [00... 59].
Example: 1111_EXPIRYTIME_37011111111_2011.10.15 16:43

MANUAL ELDES ESIM120 V1.0 13
Theexpirytime(inminutes)canbeextendedorshortenedforaparticularuser.Itispossible
toextend/shortenexpirytimebyusernameorbyphonenumber.
Inordertocheckthesetexpirydate&timevalueforaparticularuser,sendtheSMSmessage.
Itispossibletochecktheexpirydate&timebyusernameorbyphonenumber.
The user database allows to enable one or several schedulers by their number. The scheduler
sets a period of time according to which a particular user gains access to output control. It is
possible to enable the scheduler by user name or by phone number.
For more details on how to set the schedulers, please, refer to chapter 2.6
Extend/Shorten
Expiry Time
Check Expiry
Date & Time
Enable Scheduler
(-s) for User
SMS text:
XXXX_EXPIRY_37011111111_Z or XXXX_EXPIRY_UserName_Z
Value: Z – time in minutes, range [0... 2147483648]
Example: 1111_EXPIRY_UserName1_12
SMS text:
XXXX_EXPIRYTIME_37011111111_?
or XXXX_EXPIRYTIME_UserName_?
Example: 1111_EXPIRYTIME_UserName1_?
SMS text:
XXXX_NSCHED_37011111111_1:ON_2:ON_3:ON_4:ON_5:ON_6:
ON_7:ON_8:ON or XXXX_NSCHED_UserName_1:ON_2:ON_3:ON_
4:ON_5:ON_6:ON_7:ON_8:ON
Example: 1111_NSCHED_37011111111_2:ON_3:ON_8:ON

14
The user database allows to disable one or several schedulers by their number. The scheduler
sets a period of time according to which a particular user gains access to output control. It is
possibletodisablethescheduler(-s)byusernameorbyphonenumber.
For more details on how to set the schedulers, please, refer to chapter 2.6
Inordertocheckthewhichscheduler(-s)isenabled/disabledforaparticularuser,sendthe
SMSmessage.Itispossibletochecktheexpirydate&timebyusernameorbyphonenumber.
Disable Scheduler
(-s) for User
Check Scheduler (-s)
SMS text:
XXXX_NSCHED_37011111111_1:OFF_2:OFF_3:OFF_4:OFF_5:O
FF_6:OFF_7:OFF_8:OFF or XXXX_NSCHED_UserName_1:OFF_2
:OFF_3:OFF_4:OFF_5:OFF_6:OFF_7:OFF_8:OFF
Example: 1111_NSCHED_UserName1_4:OFF_6:OFF_7:OFF_8:OFF
SMS text:
XXXX_NSCHED_37011111111_? or XXXX_NSCHED_UserName_?
Example: 1111_NSCHED_37011111111_?
NOTE: Several schedulers can be enabled and disabled for particular user at once by sending one SMS message.
Example: 1111_NSCHED_UserName1_1:ON_4:OFF_6:ON

MANUAL ELDES ESIM120 V1.0 15
Thesystemsupportsupto8schedulersaccordingtowhichthedatabaseuser(-s)gainsaccess
tocontroltheoutput(-s).Inaddition,theschedulersareusedforautomaticoutputon/o
action. The starting and ending of time period can be congured for each scheduler. It is also
possible to set the frequency by weekdays on which the time period of the particular sche-
duler is valid. This SMS message sets the time period and enables one or several weekdays for
the particular scheduler.
This SMS message sets the time period and disables one or several weekdays for the particular
scheduler.
Set Scheduler –
Enable Weekdays
Set Scheduler –
Disable Weekdays
SMS text:
XXXX_SCHEDx_ST:HH:MM_EN:HH:MM_MO:ON_TU:on_WE:ON_
TH:ON_FR:ON_SA:ON_SU:ON_AL:ON
Value: x – schduler number, range – [1... 8]; ST – start of time
period; EN – end of time period; HH – hours, range – [00... 23];
MM – minutes, range – [00... 59]; MO – Monday; TU – Tuesday;
WE – Wednesday; TH – Thursday; FR – Friday; SA – Saturday; SU
– Sunday; AL – always.
Example: 1111_SCHED3_UserName1_ST:15:34_EN:18:23_
MO:ON_FR:ON
SMS text:
XXXX_SCHEDx_ST:HH:MM_EN:HH:MM_MO:OFF_TU:OFF_
WE:OFF_TH:OFF_FR:OFF_SA:OFF_SU:OFF_AL:OFF
Value: x – schduler number, range – [1... 8]; ST - start time of
time period; EN – end time of time period; HH – hours, range
– [00... 23]; MM – minutes, range – [00... 59]; MO – Monday;
TU – Tuesday; WE – Wednesday; TH – Thursday; FR – Friday; SA –
Saturday; SU – Sunday; AL – always.
Example: 1111_SCHED2_ST:08:15_EN:18:00_TU:OFF_WE:OFF_
SU:OFF
2.6 Scheduler Settings
NOTE: Several weekdays for particular scheduler can be enabled and disabled at once by sending one SMS message.
Example:1111_SCHED5_ST:09:20_EN:15:43_MO:ON_TU:OFF_SA:OFF
NOTE: When AL (always) parameter is enabled, other weekday parameters become inactive.

16
Manufacturer default C1 and C2 output names: C1 – Controller1, C2 – Controller2. The
length of each output name can be up to 10 characters including space symbol. Send the
following SMS message in order to set a new output name.
Thisfeatureturnsotheoutputandchangestheoutputstartupstatetonormallyclosed(NC)
at the same time. It is possible to turn o the output by output number or by output name.
Thisfeatureturnsontheoutputandchangestheoutputstartupstatetonormallyclosed(NC)
at the same time. It is possible to turn on the output by output number or by output name.
Output Name
Turn OFF Output
/ Output Startup
State - NO
Turn ON Output
/ Output Startup
State - NC
SMS text:
XXXX_Cx:NewOutpuName
Value: x – output number; range – [1.. 2]
Example: 1111_C2:GATES02
SMS text:
XXXX_Cx:OFF or XXXX_OutputName:OFF
Value: x – output number; range – [1.. 2]
Example: XXXX_Gates2:OFF
SMS text:
XXXX_Cx:ON or XXXX_OutputName:ON
Value: x – output number; range – [1.. 2]
Example: XXXX_C2:ON
2.7 Output Conguration
NOTE: Semi-colon characters, parameter names and/or values are not allowed in controller names, eg. PSW, STATUS, ON,
OFF etc.

MANUAL ELDES ESIM120 V1.0 17
After the user makes phone call to the relay connectors of output are in normally closed state
(NC)forasetdurationvalue.Afterthisdurationisover,therelayconnectorsoftheoutput
switchesbacktonormallyopened(NO)state.Bydefaultoutputpulsedurationis2seconds.
The user database allows to enable one or several schedulers by their number. The scheduler
sets a period of time according to which a particular output is turned on/o.
For more details on how to set the schedulers, please, refer to chapter 2.6
The user database allows to disable one or several schedulers by their number. The scheduler
sets a period of time according to which a particular output is turned on/o.
For more details on how to set the schedulers, please, refer to chapter 2.6
Output Pulse Duration
(Relay Delay)
Enable Scheduler
(-s) for Output
Disable Scheduler
(-s) for Output
SMS text:
XXXX_TIMERx:TT
Value: x – output number; range – [1... 2]; TT – pulse duration in
seconds; range - [1-10]
Example: XXXX_TIMER2:5
SMS text:
XXXX_OSCHEDx_1:ON_2:ON_3:ON_4:
ON_5:ON_6:ON_7:ON_8:ON
Value: x – output number; range – [1.. 2]
Example: 1111_OSCHED1_2:ON_3:ON_8:ON
SMS text:
XXXX_OSCHEDx_1:OFF_2:OFF_3:OFF_4:OFF_5:
OFF_6:OFF_7:OFF_8:OFF
Value: x – output number; range – [1.. 2]
Example: 1111_OSCHED2_4:OFF_6:OFF_7:OFF_8:OFF
NOTE: Several schedulers can be enabled and disabled for particular output at once by sending one SMS message.
Example: 1111_OSCHED1_1:ON_4:OFF_7:ON_8:OFF

18
ThisfeatureallowstoreceiveareportbySMSonthepresentinput&outputstatus(enabled/
disabled),input&outputnamesandinputdelayvalue.
Manufacturer default input names: Z1 – Zone1, Z2 – Zone2, Z3 - Zone3. The length of each
input name can be up to 8 characters including space symbol. Send the following SMS mes-
sage in order to set a new name.
By default all system inputs are enabled. In order to disable a particular input, send the fol-
lowing SMS message. It is possible to disable the input by input number or by input name.
Input & Output
Status
Input Name
Disable Input
SMS text:
XXXX_STATUS
Example: 1111_STATUS
SMS text:
XXXX_Zx:NewInputName
Value: x – input number; range – [1.. 3]
Example: 1111_Z2:GatesOpened
SMS text:
XXXX_Zx:OFF or XXXX_InputName:OFF
Value: x – input number; range – [1.. 3]
Example: 1111_Z3:OFF
2.8 Input & Output Status
2.9 Input Conguration

MANUAL ELDES ESIM120 V1.0 19
Info SMS is a system status report that can be requested at any time. It contains information
on system date, time, GSM signal strength and user database memory status. In addition Info
SMScanbeusefultocheckthesystemstatus(online/oine)andforprepaidSIMcardusers
inordertocheckwhetherthecreditissucientforsendingSMSmessages(noSMSreply–
systemoineoroutofcredit).
In order to enable a particular input, send the following SMS message. It is possible to enable
the input by input number or by input name.
Theinputistriggeredonlyifpulseduration(delay)islongerthanthesetvalue.Bydefaultthis
duration is 600 ms for each input.
Info SMS
Enable Input
Input Pulse
Duration (Delay)
SMS text:
XXXX_INFO
Example: 1111_INFO
SMS text:
XXXX_Zx:ON or XXXX_InputName:ON
Value: x – input number; range – [1.. 3]
Example: 1111_GatesOpened:ON
SMS text:
XXXX_Tx:TT
Value: x – input number; range – [1.. 3]; TT – pulse duration in
mili-seconds; range – [100... 42000000]
Example: 1111_GatesOpened:ON
2.10 Info SMS
NOTE: The input delays can be set for several inputs at once by sending one SMS message.
Example: 1111_T1:500_T3:2000

20
The system periodically sends Info SMS to administrator user 1 at the set period of time. By
defaultthisperiodisat11:00AMdaily(period–1, time - 11).Inordertosetthenewperiod
and time, send the following SMS message.
In order to disable periodic Info SMS, send the following SMS message.
Set Periodic
Info SMS
Disable Periodic
Info SMS
SMS text:
XXXX_INFO:PP.TT
Value: PP – SMS sending period in days, range - [1... 10]; TT –
SMS sending period in hours, range – [0... 23]
Example: 1111_INFO:2.15
SMS text:
XXXX_INFO:0.0
Example: 1111_INFO:0.0
By enabling this feature the system rings back to the user after he/she performs an output
control action by phone call. The ring duration depends on the GSM operator.
In case the user answers the phone call, he/she will be able to listen on the phone to what
ishappeningaroundESIM120(amicrophonemustbeconnectedtoESIM120).The“phone
conversation”lasts until the user hangs up the phone.
Enable Call Back
SMS text:
XXXX_CALLBACK:ON
Example: 1111_CALLBACK:ON
2.11 Conrmation by Call upon Output Control Action
Other manuals for ESIM120
3
Table of contents
Other Eldes Gate Opener manuals
Popular Gate Opener manuals by other brands

RIB
RIB R50 manual

Beninca
Beninca BOB Operating instructions and spare parts catalogue

Nice
Nice ROBUS RB400 Instructions and warnings for installation and use

CFI EXTEL
CFI EXTEL Hello-c quick start guide

Roger Technology
Roger Technology SMARTY Series INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

CAME
CAME RIOCT8WS manual