PAR01 supports 1 association group
Association Group #1
Association Group #1 (max 1 node) is default to associate with the
primary controller (Gateway/Hub/Controller) for the Status
change report, refer to below for report details:
• Current Room Temperature (report in precision of 0 5°C or 1°F) (It
will be according to Configuration Parameter 39 setting to decide
the trigger level)
• Current Battery Level (Only apply in Low Battery Warning happened)
Step 4 Setup Air Conditioner IR code
• The UI of set up the IR code varies from different gateways If
gateways have dedicated UI for the IR code setup please refer to the
gateway UI and ignore the below steps
• If your gateway does not have dedicated UI for PAR01 code setup,
but support Z-Wave thermostat Command Class and Configuration
Command Class You may refer to below steps to setup the IR code
using the configuration options in your gateway
Important Information
• Different brand or model of air conditioner has different function
For example, some air conditioner only support temperature set
from 18°C - 30°C, if user set 17°C on gateway, AC Master will not
respond
• There are more than 1 code for each brand, some does not
support Heat, if User selected a code that does not support
Heat but Original air conditioner supports Heat Function, please
continue to try next code until the correct one is selected
• You can record down your Device Code for future reference after
setting up the PAR01 correctly
IR Code Learning
Step Procedure / Description Status Indicator
1 Refer to your primary controller user manual, enter to the browser
page that can input the Configuration parameter
2 Look up Below mapping table for learning, and decide the IR setting
you intend to learn next
3 Open the Gateway’s Configuration Brower page input parameter
number “25” and parameter value (according to below Mapping Table),
then complete the Configuration process
Then Green Indicator still turns ON for indicating the IR Code
Learning Start
4 Aim the Original Air Conditioner Remote at AC Master according to
below position within 1-3cm Press “Power ON“ button on the Original
Air Conditioner Remote
If the Learning is failed, repeat Step 3 to step 4
To learn next IR code, repeat Step 2 to step 4
Successful: Green Indicator flashes TWICE
Unsuccessful: Red Indicator flashes TWICE
5 Once you finished the IR Code Learning,
please go to Configuration setting page on the Gateway browser and
input parameter number “27” and parameter value “000” to select the
dedicated AC code number “000” for learning
Green Indicator flashes ONCE every time if receives a command
from Gateway