Electra TL Audio mini User manual

4 wires
EN
AUDIO TERMINALS for
TL door phone systems-
4 WIRES-RESIDENTIAL
User manual
Audiomini
Residential
0ContentsEN
Any intervention on the installation must be performed
by AUTHORIZED PERSONNEL!
DO NOT power the product at 110 – 230 Va.c.!
DO NOT hit the glass screen with hard objects!
If the glass screen is broken, DO NOT touch the product.
Protect the products against lime and dust during renovation activities.
+U = 12 … 14 Vd.c.
170x74x20 mm
0,3 kg
o o
0 C … + 45 C
IP31
Plastic Case
ATm.0S302
mini audio terminal
1Safety instructions
2Description of the
mini terminal
4Recommended cables.
Installation
5Use of the
mini terminal
3Functions of the
mini terminal
6Settings of the mini terminal
7Programming the terminals
9Maintenance of the door
phone components
10 Warranty
8Use of the outdoor panels
Safety instructionsEN
2Description of the mini terminalEN
3Functions of the mini terminalEN
Main functions
Call, answer and hands-free talk
Audio monitoring with bidirectional talk
Access command during call, talk and monitoring
1
EN
1
4Recommended cables. Installation.EN
2
4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 75 lm
6mm
25-30mm
+U
C/D
6mm
25-30mm
GND
+U
C/D
GND
STEP 1
Fasten the back case on the wall H=135cm
4.1 Installation of the mini Terminal
EN
STEP 2
Make the connections in the connector fastened on the
back of the front case.
EN
2
4 Wires
Residential
UTP cat5e (AWG24) / FTP cat5e (AWG24)
UTP cat6 (AWG23) / FTP cat6a (AWG23).
135 cm
C/D
GND
+U
GND
C/D
GND
+U
GND
4 Wire-Installation
+U
C/D
GND
25-30mm
6mm
STEP 3
1. Place the front case with the fastened connectors over
the back case.
2. Pull the terminal down until it interlocks.
Connection diagram for the mini terminal
ATm.0S302
AUDIO TERMINAL Additional
terminal
+U
C/D
GND
+U
C/D
GND
+U
C/D
GND
+U
C/D
GND
SCU/VCB
C/D
+U
GND
OUT-x
EN
3
ON/OFF
Call answer, audio-video monitoring
Access command
5Use of the mini terminal
EN
STAND-BY Mute / OFF
The terminal is off.
LED permanently red
LED off
CALL CALL
LED blinking red
LED blinking red
2
1
STEP 2
Make the connections in the connector fastened on the
back of the front case.
Residential-Installation
C/D
GND
+U
GND
GND
GND
C/D
+U
EN
4
1. CALL: When called from the outdoor panel, the terminal rings
– 3 x Ding-dong. The LED is blinking red.
2. RINGING VOLUME ADJUSTMENT: The terminal has 2 volume
levels and they can be adjusted by short successive touches of the
BEEP
key. The maximum level is signaled with 2 x [ ].
BEEEE P
3. RINGER OFF (MUTE): Long press of [ ] and LED
turning red. The terminal has the ringer off and the LED remains red.
The call will be signaled by LED blinking red. For reversing mute
BEEEE P
status, short touch of [ ] and LED turning off.
4. ANSWERING THE CALL: Short touch of Talk is initiated.
5. TALK: Hands-free conversation, without touching any key.
The talk duration is max. 2 min.
6. TALK VOLUME ADJUSTMENT: The terminal has 2 volume levels
and they can be adjusted by short successive touches of the
BEEP
key. The maximum level is signaled with 2 x [ ].
7. END TALK without access: Another short touch of .
8. ACCESS GRANTING: From Long press of . stand-by
During , or Short touch of any time. call talk monitoring
The access is signaled acoustically also, with a specific confirmation
song and the bidirectional audio communication remains opened
10 more sec.
9. AUDIO MONITORING: Short touch of Bidirectional talk
for max. 10 sec.
6Programming the terminals
EN
The manual programming of the address of the terminal
(apartment number/ family)
All Touch Line terminals are programmed from the factory with
address 1.
The terminals from apartments with numbers from 2 to 9999 will be
programmed with the number (address) of the respective
apartment / family.
The address of the terminals with numbers from 2 to 20 can be
manually programmed, according to the following procedure:
0. The entire door phone system is installed and set under tension.
1. Go to the place where the SCU central unit of the installation is
mounted. Long press (2-3 sec.) the PROG button. The red LED turns on.
2. Return to the terminal and long touch the key. You will hear a
long beep.
- Programming address 1: touch the key once. A short beep is issued.
- Programming address 2: touch the key twice. Two short beeps
are issued.
- Programming address 3: touch the key three times. Three short
beeps are issued.
Repeat the procedure for the next addresses, until 20.
NOTE: After pressing the key n times, wait a few seconds for the
acoustic confirmation of the terminal for address n. The terminal will
issue n beeps for address n programmed in the terminal.
3. Return to the SCU central unit of the installation. Press the PROG
button for a short time. The red LED turns off. The installation returns
to normal functioning mode.
For programming the Touch Line terminals installed in buildings
with a high number of apartments (higher than 15), purchase the
special terminal address programming device from the producer.
EN
5
7Use of the outdoor panels
EN
Orientable video camera
Electronic display
Touch keyboard
RFID reader
IR LED
(night lighting)
Name 1
Touch key
with the name
of the family
1 Fam. House 8 Fam. House 10-255 Fam.
Apartment building
Name 3
Name 2
Name 1
Name 4
Name 5
Name 3
Name 4
Name 4
1. STAND-BY. The keys with the names of the residents/ the call
keyboard are permanently backlighted during night. The red LED blinks
and signals the possibility of video monitoring.
2.1. CALL + TALK from outdoor panels with maximum 10 families.
Touch the key corresponding to the name of the family you are
looking for. The panel signals the action acoustically, with a ding-dong.
The call lasts maximum 1 minute. Each touch of the key reinitiates the
call. If the resident answers, the talk mode is activated. The talk takes
place hands-free, during maximum 2 min.
2.2. CALL + TALK from outdoor panels for apartment buildings.
Use the keyboard to dial the number of the desired apartment
(maximum 4 digits). The panel signals the action acoustically, with
ding-dong. The key turns red and the following message appears
on the display: C
TP r e s s
al l i n g :
N a
m
e 1
oa b o r t d i a l
The call lasts maximum 1 minute. If you do not know the number of
the apartment, search for the name of the resident in the electronic list
by touching the key.
Successively touch the key until the name of the family and the
apartment numbers show up on
the display:
1:
N a
N e xt
2:
3: page
-
m
e 1
N a
m
e 2
N a
m
e 3
If the resident answers, talk mode is initiated. The key turns
green and the following message is shown on the display:
S P EAK !
The conversation takes place hands-free, during maximum 2 min.
4. RFID card ACCESS. Approach the RFID card to the area
marked with the symbol. The panel commands the opening
of the door/gate and issues a confirmation beep sequence.
At the panel for apartment buildings, the display shows the
following message:
EN
6
The door/gate remains open
for maximum 10 sec.
ACCES
GR ANTE D
8Maintenance of the door phone components
EN
The Touch Line audio-video terminals must be kept away from water,
lime or any liquid substances, blows, fumes, powders, dust etc. In case of
renovation activities, the entire surface of the terminals will be protected
with plastic foil.
The Touch Line outdoor panels must be kept away from corrosive
substances, lime and blows.
For cleaning the glass screens, use a clean cloth and a special solution for
glass washing.
DO NOT undo the electrical connections of the video door phone
installation components.
DO NOT short-circuit the electrical connections of the video door phone
installation components.
The accumulator, optionally connected to the central unit of the video
door phone installation, must be replaced in case of defects or after
exceeding its lifespan.
9Warranty
EN
a. Warranty is granted according to the current legislation in the buyer's
country of residence, based on the purchase documents.
b. Warranty is granted for the hidden defects of the components used in
production and in case of the system not functioning according to the
present user manual.
WARRANTY IS NOT GRANTED FOR:
c. Inappropriate installation and use.
d. Deterioration, intentional blows.
e. Unauthorized interventions to any of the components of the installation.
f. Theft, fire, natural disasters.
g. Lack of protection of the installation components in case of renovation
activities.
Designed and produced by ELECTRA Made in EU 10.2018 USM.ATm02.ELY04
ELECTRA s.r.l
Bd. Chimiei nr.8,Iași - 700291 - RO
+40 232 214.370 +40 232 232.830
[email protected]
www.electra.ro
ELECTRA
Bischoffgasse 5/3-4, 1120 Wien - AT
+43 1 810 20 99
[email protected]
www.electra-automation.at
Building Communications GmbH
Certificate no. E307311
ISO 9001:2015
ISO 14001:2015
Certificates no. 73 100 4856, 73 104 4856
by TÜV HESSEN
The products are manufactured under
Quality and Environment Management System
The products are
CE certified.
R
The products contain UL-compliant
printed circuit boards.
Certificate by
R709 ICPE
ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain
ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain

Popular Touch Terminal manuals by other brands

Texas Instruments Silent 700 763 operating instructions

Texas Instruments

Texas Instruments Silent 700 763 operating instructions

Colormetrics PS1000 user manual

Colormetrics

Colormetrics PS1000 user manual

Hafele DT 600 FH installation instructions

Hafele

Hafele DT 600 FH installation instructions

Applied Comfort NFWC Series Installation & operation manual

Applied Comfort

Applied Comfort NFWC Series Installation & operation manual

Swegon TBLZ-4-75 instructions

Swegon

Swegon TBLZ-4-75 instructions

Thrane&Thrane Sailor 250 FleetBroadband manual

Thrane&Thrane

Thrane&Thrane Sailor 250 FleetBroadband manual

Equinox Systems T4220 Quick reference guide

Equinox Systems

Equinox Systems T4220 Quick reference guide

Compaq t1000 - Terminal Thin Client PC Network installation guide

Compaq

Compaq t1000 - Terminal Thin Client PC Network installation guide

Acrel ARTU Installation & operation instructions

Acrel

Acrel ARTU Installation & operation instructions

Anywire AnyWireASLINK BL296PB-16F-4A-20 Product guide

Anywire

Anywire AnyWireASLINK BL296PB-16F-4A-20 Product guide

Siemens 3VL9400-4RA00 operating instructions

Siemens

Siemens 3VL9400-4RA00 operating instructions

Mercury M-600 Series user manual

Mercury

Mercury M-600 Series user manual

Paytec Apex 7000 user guide

Paytec

Paytec Apex 7000 user guide

takepayments Desk 3500 installation guide

takepayments

takepayments Desk 3500 installation guide

Vasco DIGIPASS DP 260 user manual

Vasco

Vasco DIGIPASS DP 260 user manual

Control Data Corporation CDC 721 Operator's guide

Control Data Corporation

Control Data Corporation CDC 721 Operator's guide

Radio Shack TRS-80 PT-210 Service manual

Radio Shack

Radio Shack TRS-80 PT-210 Service manual

COBHAM EXPLORER 323 User & installation manual

COBHAM

COBHAM EXPLORER 323 User & installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.