2
0409 2
D1435
xxxxxxx
USA/CANADA
Manufacturer’s address:
ELECTROLUX LAUNDRY SYSTEMS France
52 rue Pasteur BP6
10430 Rosières Près Troyes - France
Model
IC433..
Orifice size: Nat 2.3 mm (x3)
Propane 1.3 mm (x3)
Serial No
...../........
MFG. Date
../../....
QC No
........
Gas Type: NAT □
Propane □
Conforms to: - UL 141 : 2007
- UL 795: 2006
- CGA 7.3 : 1971
- NFPA 79 : 2002
Heat Input Nat gas:
68240 BTU/hour
(C.V 34,02 MJ/m³)
Gas Supply Pressure: Nat: 8.0 w.c, 2.0 kPa
Manifold Pressure: Nat: 4.49 w.c, 1.12 kPa
Heat Input Propane gas:
68240 BTU/hour
(C.V 46,34 MJ/kg)
Gas Supply Pressure: Propane: 14.9 w.c,
3.7 kPa
Manifold Pressure: Propane: 14 w.c, 3.5 kPa
Electrical rating: Volts 120 Total input Amp: 5.5 A
Hertz 60 Fuse size: 12 A
Phase 1
WARNING: Improper installation, adjustment, alte-
ration, service or maintenance can cause property
damage, injury or death. Read the installation,
operating and maintenance instructions thoroughly
before installing or service this equipment. For safety
reasons use only original spare parts.
ATTENTION : L’installation, le réglage, la mainte-
nance, ou l’entretien inapropriés peuvent causer des
dégats matériels, des blessures ou la mort. Lisez
complètement les notices d’installation, d’utilisation et
d’entretien avant d’installer, d’utiliser ou d’entretenir
cet équipement. Pour des raisons de sécurité, utiliser
uniquement des pièces de rechange d’origine.
01103040
PageNotice Date
OPERATING
HANDBOOK
The machines described in this handbook have an ironing capacity of 1.650 m (65") or 2.065
m (811/3") wide according to their type.
The ironing speed can be adjusted according to the linen texture and its degree of moisture.
The temperature of the ironing cylinder can also be adjusted by a thermostat.
The parameters are displayed by a control panel.
2. General
Identification
plate
Adjustment label
(for gas machine only)
Identification plate