ELEKTROBOCK CS3-16 User manual

CS3-16CS3-16
TIMING
SWITCH
MADE IN CZECH REPUBLIC
• 8 functions in one
connection, period
of time in the range
from 0.5 s to 20 hours
• switching element is
power relay
• mounting under
the control element
MULTIFUNCTIONAL FOR HIGHER LOADS

L
1
N
LN
max. load
see table
specifications
Possibility of control
switch
button
CS3-16
ON OFF ON OFF
CS3-16 timing switch is a multifunctional relay with
possibility to set eight functions. Switching element
is relay 16 A for control bigger loads
(see table Specifications).
is linear, possible in the range from
0.5 s to 20 hours. The coarse setting is made
by miniature switch according to table and fine
setting by trimmer with using of a small
screwdriver. Thanks to special circuit used,
a long-term stability of the time set is ensured,
without substantial dependence on time,
ambient temperature and supply voltage.
TIME SETTING
DESCRIPTION
ON OFF
WIRING DIAGRAM
10 min - 3 h 20min
1 min - 20 min
30 min - 10 h
1 h - 20 h
For intervals shorter than 20 s, max. number of switching on amounts to 3/min.
0.5 s - 10 s
1 s - 20 s
10 s - 3 min 20 s
30 s - 10 min

SETTING THE FUNCTION
1, Timing relay with interrupt option
the load is activated on and the timing starts immediate-
ly after pushing the button. Further pushing the button
in the course of timing deactivates the load.
2, Delayed switching off
the load is activated at the moment of button discon-
nection, after timing the load is deactivated (similar to
CS3-1).
E.g.: staircase time-switch
E.g.: bathrooms, toilets
ts = interval of
switching on
tc = the time set on
CS3-16
tcx = interrupt (tcx< tc)
ts = interval of
switching on
tcs = interval of
appliance
running
ON OFF
Position of switch
ON OFF
Position of switch

Qs
Qsc
ts
tcs
t
t
tc
4, Delayed switching off without blocking
the load is activated on immediately after pushing the
button, but the timing starts after button is
disconnection (similat to CS3-4).
3, Multi-timing relay with blocking
the number of pushing the button (max. for 5 times)
increases the time interval set. The sixth pressing
zeroes the interval. If you press the button for approx.
3 s in the course of timing, the load is deactivated.
ts = interval of
switching on
tx = interrupt (ts=3s)
tc = the time set on
CS3-16
tcx = n x tc (n<5)
ts = interval of
switching on
tc = the time set on
CS3-16
tcx = tc
E.g.: staircase time-switch
E.g.: staircase time-switch
ON OFF
Position of switch
ON OFF
Position of switch

6, Delayed switching on
when the button is pressed, it times the set time
(delay), afterwards activates the load that is activated
up to button disconnecting.
5, Impulse relay (controlled from more locations)
pressing the button activates the load, further pressing
the button deactivates the load. It is not important, how
long the button is pressed..
ts = interval of
switching on
tcs = interval of
appliance
running
ts = interval of
switching on
tx = the delay set
on CS3-16
tcs = interval of
appliance
running
E.g.: the load is controlled from more locations
E.g.: bathrooms, toilets
ON OFF
Position of switch
ON OFF
Position of switch

8, Flasher
when the button is switched on permanently, it activates
the load in time intervals set 1:1.
7, Delayed switching on and off
when the button is pressed, it times the set time
(delay), afterwards the load is activated. After button
disconnecting, the load is deactivated with the same
delay as set. If is button disconnecting during first
delay then function is not canceled and timing is same
as set.
ts = interval of
switching on
tx = the delay set
on CS3-16
tcs = interval of
appliance
running
ts = interval of
switching on
tc = the time set
on CS3-16
E.g.: bathrooms, toilets
E.g.: illuminated advertisements, warning lights
ON OFF
Position of switch
ON OFF
Position of switch

CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
CS3-1 activates the ventilator after switching the light off.
CS3-1B activates the ventilator in setting time after
switching the light on and deactivates in setting
time after switching the light off.
CS3-2 timing switch for lighting.
CS3-4 is switched on immediately after pushing the
button, but the timing itself starts only after
disconnecting - connection without neutral lead.
CS3-4B similar to CS3-1B, connection without neutral lead.
CS3-4M multifunctional timing switch - connection without
neutral lead.
Setting the time and installation should be performed on
system that is not live and by a person with appropriate
qualification in electrical engineering.
Send the timing switch
for guarantee and
after-guarantee service
to manufacturer’s
address.
Summary of produced types
SPECIFICATIONS
Power supply 230 V/ 50 Hz
Switching element relay, 16 A
Lamp 2000 W
Fluorescent lamp 750 W (max.5 PCS)
Economy lamp max. 5 PCS
Squirrel cage motor 450 VA
Max. cross sect. area
of inst. Cu cond. 0,5 mm2
Protection IP20 and higher according to the mounting
Working temperature 0°C to +35°C

ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel./fax: +420 541 230 216
Pb
LEAD FREE
in compliance with RoHS
MADE IN CZECH REPUBLIC
www.elbock.cz
The possibility to set 8 functions:
Timing relay with interrupt option - the load is activated on and
the timing starts immediately after pushing the button. Further
pushing the button in the course of timing deactivates the load.
Delayed switching off (similar to CS3-1) - the load is activated
at the moment of button disconnection, after timing the load is
deactivated.
Multi-timing relay with blocking - the number of pushing the
button increases the time interval set. If you press the button for
approx. 3 s in the course of timing, the load is deactivated.
Delayed switching off without blocking - kthe load is activated
on immediately after pushing the button, but the timing starts after
button is disconnection.
Impulse relay (controlled from more locations) - pressing the
button activates the load, further pressing the button deactivates
the load.
Delayed switching on - when the button is pressed, it times the
set time (delay). Afterwards it activates the load that is activated
up to button disconnecting.
Delayed switching on and off - when the button is pressed, it
times the set time (delay), afterwards the load is activated. After
button disconnecting, the load is deactivated with the same delay.
Flasher - when the button is switched on permanently, it activates
the load in time intervals set 1:1 (illuminated advertisements etc.).