Elko RF Touch-B User manual

C
z
USER'S MANUAL
S
K
E
N
R
O
P
L
H
U
R
U
WIRELESS TOUCH
CO N T R O L U N I T

RF Touch user manual
We want to thank you for your purchase of the RF Touch control unit, which is an element of
wireless RF Control system.
RF Touch allows:
you to control many devices trough touch screen
- heating control
- dimming lights
- switching of electrical appliances and equipment
- blinds
- a combination of detectors
- function timers
- Group control of electrical equipment
everything with clear visualization
wireless communication without the need for cabling
2

RF Touch user manual
Contents:
Before you start ....................... 3
Overview of wireless devices ... 4
Characteristics of RF Touch ..... 6
Technical specifications ........... 7
Installation of RF-Touch W ....... 8
RF Touch Installation-B ............ 9
Description of Control icons .... 10
Basic Steps ............................... 11
Settings
- Default setting ......................... 12
- Menu(creating and naming) ... 13
- Programming ........................... 15
- Assign a new receivers ....... 16
- Assigned receiver ............... 17
- Detectors ............................ 20
- Quick Control ..................... 22
- Display ..................................... 23
- Other ........................................ 23
Control
- Temperature regulation .......... 25
- Switching ................................. 28
- Dimming .................................. 31
- Blinds ....................................... 32
- Detectors ................................. 34
- Quick control............................ 35
What to do if ............................ 36
Installation Form ..................... 38
E
N
Before you start
The instruction manual is intended for installation and use of the equipment. Instructions are always included in the product packaging.
Installation and connection can only make personnel with appropriate qualifications, in compliance with all applicable laws, who are
perfectly familiar with this instructions and functions. Trouble free function is also dependent on transportation, storage and handling.
In case of any signs of damage, deformation, malfunction or missing parts, do not install this product and return it to the seller.
Product and its parts must be at the end of its lifetime handled as electronic waste. Before installation, make sure that all wires, connected
parts or terminals are not live. During the installation and maintenance is necessary to follow safety regulations, standards, guidelines
and special provisions for working with electrical equipment.
3

Overview of wireless RF Control devices
RF Control system
All actuators of the RF Control
System can be controlled by
wireless central unit and all
transmitters of the system
simultaneously.
CENTRAL WIRELESS UNIT
RF Touch-W
for surface mounting
100 - 230V AC or
adapter (external)
12 V DC
CONTROLLER
RF Touch-B
for mounting
in the installation
box
100 - 230V AC
RF Pilot
remote controller,
colours: white,
anthracite
TRANSMITTERS
RF KEY
RFWB-20/G
RFWB-40/G
BLIND ACTUATORS
RFJA-12B/230V
blind actuator
2 x 8A switching
relay protection
230V AC
4-channel remote
controller - key pendant
2-channel wireless
switch in the design
LOGUS90
4-channel Wireless
switch in the design
LOGUS90
RFIM-20B
universal transmitter module
under the switch or button
wall box installation
RFIM-40B
universal transmitter module
under the switch or button
wall box installation
RFSG-1M
Transmitting module
1-module
230 V AC
RFJA-12B/24V DC
blind actuator
contactless switching
12-24V DC
TEMPERATURE ACTUATOR
RFSTI-11B
RFSTI-11/G
RFTI-10B
RFTC-10/G
wireless switching actuator
with temperature sensor
in design to installation box,
230V AC
wireless switching actuator
with temperature sensor
with manual
control buttons directly
on the unit, 230V AC
wireless temperature sensor
1 x CR 2477 3V battery
digital temperature
controller
2 x 1.5V AAA batteries
4

Overview of wireless RF Control devices
SWITCHING ACTUATORS
RFSA-11B
RFSA-61B
RFSA-62B
RFSA-61M
RFSA-66M
single channel
single function
switching actuator
1 x switching
contact 16 A
230V AC
single channel
multifunction
switching actuator
1 x switching
contact 16A
230V AC
2 channel
multifunction
switching actuator
2 x 8A switching
contact
6 functions
230V AC
single channel
Multifunction
switching actuator
1x changeover
contact 16 A
6 functions
230V AC
six-channel
Multifunction
switching actuator
3 x 8 AND NO
3 x changeover
contact 8A
6 functions 230V AC
DIMMING ACTUATORS
Angle antenna
RFDA-11B
single function
dimming actuator
1 light scene,
function OFF, 230V AC
E
N
RFDA-71B
multifunctional dimming actuator
7 functions,
AC 230V / 250V
for plastic
switchboards
supplied as standard
for RFSA-61M,
FSA-66M, RFSG-1M
Angle Antenna
for metal
switchboard
can be ordered for
RFSA-61M,
RFSA-66M, RFSG-1M
ANALOGUE ACTUATOR
RFDAC-71B
Dimmable ballast
Thermo-control
DETECTORS
actuator with analog
output 0 (1) - 10 V
1 x switch contact 16 A
7 functions, 230V AC
for dimming of fluorescent
lamps
supplied on request
with the product RFDAC-71B
of heating valves
supplied on request
with the product RFDAC-71B
JA-80P
JA-81M
JA-82M
5

Characteristics of RF Touch
Control Unit of the wireless system RF Control - RF Touch provides intelligent control of the RF units.
It can be used for:
Central control of all units from one place
Complete overview (visualization) of the current status of units (appliances / equipment)
Features:
sends command to temperature, switching, dimming and shutter actuators
accepts commands from the transmitters, actuators, temperature sensors and detectors
processing programs for heating and regulation
Design:
RF Touch-B fits in the round installation box with a supply voltage of 100 - 230 V AC
RF Touch-W for surface mounting with power supply from the back side: 100 - 230 V AC or from the side (via jack):
12 V DC
3.5 inch color touch screen - no mechanical buttons
RF Touch frames in the base plastic (white, black) or luxurious design Logus90 (glass, metal)
Color of the interframes - white, ivory, ice, mother of pearl, aluminum, silver
Colors of the boxes (only for RF touch-W) - white, ivory, dark gray, light gray
Backup time in case of power failure is 48 hours
40 actuators and 30 OASIS detectors can be assigned to each RF Touch unit
RF Touch can be combined with units of RF Control marked as Oasis & Touch Compatible
6

Technical specifications
Technical parameters
Display
Type:
Resolution:
Aspect ratio:
Visible area:
Backlight:
Touch screen:
Display:
Control:
Power supply
Voltage /
specific current:
Power consumption:
Power supply connector:
Control
Range up to:
Minimal range
RF Touch – actuator:
Frequency:
RF Touch-B
RF Touch-W
Technical parameters
Connection
RF Touch-B
push-in
RF Touch-W
screwless terminal
push-in or jack
2.1 mm
color TFT LCD
320 x 240 pixels / 262,144 colors
3:4
52.5 x 70 mm
active (white LED)
resistive 4-wire
3.5”
Touch sensitive
from the back side
100 - 230 V AC
from the side 12 DC *
max. 5 W
A1 - A2
100 m
1m
868 MHz
Max. cross section of wires:
Operating conditions
Operating temperature:
Storage temperature:
Protection:
Overvoltage category:
Pollution degree:
Operating position:
Installation:
Dimensions:
Weight **:
Standards:
max. 2.5 mm
2
/ 1.5 mm
2
with socket
0 ... +50°C
- 20 ... +70°C
IP 20
III.
2
arbitrary
installatin a box
94 x 94 x 12 mm
127 g
EN 60730-1
wall box installation
94 x 94 x 24 mm
175 g
E
N
100 - 230 V AC
* adapter is included for RF Touch-W
** weight with plastic frame
7

RF Touch-W
POWER SUPPLY OVER TERMINALS
POWER SUPPLY OVER ADAPTER
A1
100 - 230V AC
A2
FITTING ON THE SURFACE
adapter included with RFTouch-W
8

RF Touch-B
POWER SUPPLY OVER TERMINALS
FITTING TO THE INSTALLATION BOX
A2
AC 230V
A1
E
N
9

Description of Control Icons
Basic
RF Touch version Information
and number of assigned units
settings
back to the home screen
step back
Main menu
Temperature regulation
Switching
Dimming
Blinds
Detectors
Quick kontrol
Heating
temperature
Dimming
switch ON
switch OFF
dimming
light inclination
light declination
Switching
switch ON
switch OFF
impuls
button
time function
- delayed switch on
- delayed switch off
0-10V
Setup Menu
scroll up
scroll down
OK
confirm
Keyboard
Blinds
rise blinds
lower blinds
OK
confirm
yes/selected
no/not selected
add
edit/remove
name/adressof the actor(s)
delete
.
abc
A/a
_
a/1
OK
C
dot
letters
small/capital letters
space
switch - the letters / numbers
confirm
erase previous
regulation
10

Basic Steps for Successful Programming
1st Step – Placing of the RF Touch and RF units
Keep in mind that the radio signal range of RF installation
depends ON building construction, materials and placing of all
units.
Transmission of radio-frequency signals through various materials.
Wooden structures
with plasterboard
plates
2nd Step - Fill Installation Form
- device name that you want to manage (to create a menu)
- the names of units (for the correct classification of the
group, for example: RFSA-61B)- addresses of units (to
identify the actuator, for example: 577515)
Installation form can be found at the end of this manual.
E.g. RFSA-61B
standard glass
Name
80-95 %
80-90 %
E
N
brick wall
reinforced concrete
60-90 %
20-60 %
E.g. 577515
Adress
metal plates
0-10 %
3nd Step - Set menus (create names)
Create a list of names of the controlled device in the
Settings / Menu (create name).
4rd Step – Programming
Programming of the RF units with RF Touch is carried out in
the Settings / Programming menu.
11

SETUP
Initial setup
When the RF Touch is switched on for the first time, you will be automatically redirected to the display calib-
ration screen. Touch screen can be controlled by the light touch (of about0.5-1s) in the desired location. On the
screen (Fig. 1) then appears cross in each corner of the screen, which need to be pressed twice. This will calibrate
the device. The display then shows the RF logo icon
and then touch icon signalizing scanning of the actuators.
fig. 1
Content of the main screen
date
time (touch in the upper right corner of the display will switch between analog
- digital clocks (Figure 2 - Figure 3)
display at the bottom of the screen is customable, eg: heating mode, a often used device ...
Touch the clock area to enter the Main menu. If you want to get to the main menu from
sleep mode, you need to touch the screen anywhere.
fig. 2
fig. 3
Main Menu / Settings
The settings menu can be opened by touch in the
Upper right corner screen on the symbol
and
insertion of password (it´s setting from production – 1111)
(fig. 4-6),which you can change everywhen.
fig. 4
fig. 2
fig. 5
Language
Selection of required
Language - Figure 6.
Save setting by
pressing
fig. 6
Date and time
Settings (Fig.7-8):
Date and Time
automatic
transition between
winter / summer
time (for time
Zone GTM +01:00)
Format settings
hours (12h / 24h
mode)
To save Settings
press
fig. 7
fig. 8
12

SETUP
Menu (create name)
Menu (create name) is used to add, edit or remove the names of the controlled device. In this menu (Figure 1) you need to first
create your own device names for the sections you want to control.
Creating names is important for successful programming of the RF Touch. For each actuator, which is involved in the installation
you have to create unique name.
The content of this menu is not set at the factory.
Menu (create name) / Add
Press the
Add icon (Fig. 2) to show a selection of sections (Fig. 3):
Temperature regulativ Dimming Blinds Switching Control Speed
Choose the section where you want to add the device name and type your own text (max. 20 characters).
Detectors
E
N
Example 1: If you want to control the blinds - Place the name to the section of the blinds (Fig.3-5).
Example 2: If you want to control a group of blinds together, first create all the blinds names in the blinds section and then create new name for group control in Quick
control section.
fig. 1
fig. 2
fig. 3
fig. 4
fig. 5
Note: Actuator RFTI-10B can be connected with two temperature sensors. For each sensor, you can create your own name.
13

SETUP
Menu (create name) / Edit
Edit button is used to change or modify the name in the crea-
ted menu.
Press the Edit icon
(Fig.1), a menu appears, select the se-
ction in which you want to edit created name (Fig. 2). Mark
selected name by touching it (Fig. 3) and then edit with dis-
played keyboard.
Press
to confirm (Fig. 4). The modified name is stored.
fig. 1
Menu (create name) / Remove
Remove button can delete unit name.
Press the Remove icon
(Fig. 5) following menu appears, se-
lect the section from which you want to remove the name (Fig.
6). Pick the device you want to delete by touching it.(Fig. 7) .
Press
to confirm the selection (Fig. 8). Selected name
will be deleted from menu.
fig. 5
fig. 2
fig. 6
fig. 3
fig. 7
fig. 4
fig. 8
14

SETUP
Programming
Programming is used to assign or remove the actuators / detectors to menu you created.
The Programming Menu can be entered by entering a password (default - 1111).
Actuators are divided into sections for which they are intended. According to the actuator's type you have to select appropriate
section - see table (eg programming actuator RFSTI-11B - find it in the Temperature regulation section).
RF Control actuators divisions
Temperature
regulation
RFSTI-11B/G
RFTI-10B INx
RFTI-10B OUT
xx
RFTC-10/G
Switching
RFSA-11B
RFSA-6x*
RFDAC-71B
Dimming
RFDA-11B
RFDA-71B
RFDAC-71B
Blinds
RFJA-12B/230V
RFJA-12B/24V DC
Detectors
JA-81M / 82M
JA-80P
E
N
fig. 1
fig. 3
internal sensor
external sensor
* RFSA-61B, RFSA-62B,RFSA-61M and RFSA-66M
x
xx
15

SETUP
Programming / Assign new
It is used to assign a name to the actuator in the menu. In the required section (heating, dimming ...) select Assign new (Fig. 1). A
list of selected sections actuators will be shown. (Fig. 2). Select the name of the actuator which you want to associate with the
RF Touch. Enter the address of actuator you want to assign( Figure 3) as indicated on the actuator. Confirm with
. From the
menu you created, select the name to which the actuator will be assigned (Fig. 4).
- Only one name can be assigned for each actuator.
- When programming, actuator must be connected with the installation.
Communication test (Fig. 6) is used to detect and display the current status of the RF signal between the RF Touch and progra-
mmed actuator.
- Press Start (Fig. 7) to initiate the test, the current status of the signal is displayed in percentage.
- Press Return to Programming to get back to main menu of programming.
fig. 1
fig. 2
fig. 3
fig. 4
fig. 5
fig. 6
fig. 7
Programming / Temperature regulation / Assign New / RFTI-10B and RFTC-10/G
These two units are temperature sensors, communication test is not executed during programming.
Note: The actuator RFTI-10B is able to be connected with two temperature sensors, each sensor may have its
own name. Address of the actuator is the same for both sensors.
16

SETUP
Programming / Associated Receivers
It serves to control or remove the actuator from the name of the menu you created.
In the selected section (Figure 1 - Temperature regulation, dimming ...) select Assigned receivers (Fig. 2) a list of names specified
in this section will be shown(Fig. 3). Touching on the name you will assign it to the actuator (Fig. 4).
By pressing
arrows you can check the name and address assigned to the actuator (Fig. 4, 5).
By touching the name or address of the actuator you can remove the actuator (Fig. 7) or carry out communication test (Fig. 8).
E
N
fig. 1
fig. 2
fig. 3
fig. 4
fig. 7
fig. 5
fig. 6
fig. 8
17

SETUP
Programming / Temperature regulation / Assigned receivers / RFTI-10B and RFTC-10/G
Function Assigned receivers in Temperature reg. - RFTI-10B and RFTC-10/G are used to pair or remove temperature units from the actuator.
In the Temperature regulation section, press the screen to select Assigned receivers; the list of names assigned in this section will be
displayed Press the name to display the assigned actuator. Select the name to which the RFTI-10B or RFTI-10/G is assigned (Fig. 1-3).
Use arrows
to check the name and address of the assigned actuator (Fig. 4-5).
Pair with...
Paired with...
Touch the name or address of the actuator to display the menu (Fig. 6):
Remove
Programming / Temperature regulation / Assigned receivers / RFTI-10B and RFTC-10/G / Remove
Serves to cancel the link between the temperature unit and the name from the menu Temperature regulation.
fig. 1
fig. 2
fig. 3
fig. 4
fig. 6
fig. 5
18

SETUP
Programming / Temperature regulation / Assigned receivers / RFTI-10B and RFTC-10/G / Pair with...
Serves to combine the RFTI-10B or RFTC-10/G temperature unit with the RFSA-61M or RFSA-61B or RFDAC-71B multifunction actua-
tor, where the temperature unit measures the current temperature and the multifunction actuator switches on the Temperature re-
gulation based on the measured temperature. The multifunction actuator switches based on the set temperatures in the RF Touch.
Note: the attached actuator RFTI-10B can be used in two ways:
For temperature measurement (without pairing with a switching actuator)
When paired with the multifunction switching actuator it can switch heating equipment on the basis of the measured temperature.
Programming / Temperature regulation / Assigned receivers / RFTI-10B and RFTC-10/G / Paired with...
Shows multifunction switching actuator, which is paired with a temperature actuator. By touching the name of the actuator you
can remove a paired actuator.
Note: Battery indication on the display (Fig. 1) informs of low battery in one of the temperature units. Press the battery to display the unit name. Use arrows
to switch between the name and the address of the unit (Fig. 2-3).
E
N
fig. 1
fig. 2
fig. 3
19

SETUP
Programming / Detectors
Section detectors (Fig. 1) is intended for assign or remove OASIS detectors to menu.
Select Assign detector (Fig. 2). The list of detectors will be shown. Select the detector you want assign to the RF Touch unit (Fig. 3).
RF Unit Touch will enable search (Fig. 4) searching icon
is shown (the shortest distance to assign a detector is 1.5m). RF Touch
will recognize new detector when batteries are inserted into the detector. Confirm the assignment by dressing
(Fig. 5).
Choose a name to which the detector will be assigned (Fig. 6). Each detector may be assigned only to one name.
Pressing arrows
can display the name or address associated with the detector (Fig. 7, 8).
When you touch on the name or address of the detector following options appear (Fig. 9):
Remove… Pair with ... Paired with ...
fig. 1
fig. 2
fig. 3
fig. 5
fig. 6
fig. 4
fig. 7
fig. 9
fig. 8
20
Other manuals for RF Touch-B
1
This manual suits for next models
1
Table of contents
Other Elko Control Panel manuals