Rosslare AC-425IP-BU User manual

AC-425x-B Series
Expandable 4-Reader Networked
Access Control Panel
Hardware Installation and User Guide
Models:
AC-425-B
AC-425IP-B

Copyright © 2022 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE
ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter:
"ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means,
electronic or mechanical, for any purpose, without the express written permission of
ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other
intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS
DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER
LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD
PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any
license to these patents, trademarks, copyrights or other intellectual property rights, except
as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being
obliged to announce such revisions or changes beforehand or after the fact.

Table of Contents
AC-425x-B Series Hardware Installation and User Manual iii
Table of Contents
1. Introduction ......................................................................................8
2. Technical Specifications...................................................................10
2.1 AC-425x-DIN ............................................................................................... 10
2.2 AC-425x-B Installed in ME-1015 ................................................................. 11
3. AC-425x-B Panel Setup ....................................................................12
3.1 Inputs Wiring – Non-Supervised Inputs...................................................... 13
3.2 Inputs Wiring – Supervised Inputs.............................................................. 14
3.3 Outputs Wiring ........................................................................................... 14
3.4 Power Supply.............................................................................................. 15
3.5 AC-425x-B Wiring Communications ........................................................... 17
3.6 Readers....................................................................................................... 17
3.7 MD-IO84B................................................................................................... 18
3.8 MD-D04B .................................................................................................... 18
4. Input and Output Connections ........................................................19
4.1 Input Types................................................................................................. 19
4.1.1 Normally Open Input Connection .......................................................................... 19
4.1.2 Normally Closed Input Connection ........................................................................ 20
4.1.3 Normally Open Supervised Single EOL Resistor Input Connection......................... 20
4.1.4 Normally Open Supervised Double EOL Resistor Input Connection....................... 21
4.1.5 Normally Closed Supervised Single EOL Resistor Input Connection....................... 21
4.1.6 Normally Closed Supervised Double EOL Resistor Input Connection..................... 22
4.2 Inputs Description ...................................................................................... 22
4.2.1 Request-to-Exit (REX) Button Input ....................................................................... 22
4.2.2 Door Monitor Input ............................................................................................... 23
4.2.3 General Purpose Inputs ......................................................................................... 23
4.3 Outputs....................................................................................................... 24
4.3.1 Door Lock............................................................................................................... 24

Table of Contents
iv AC-425x-B Series Hardware Installation and User Manual
4.4 Card Readers and Keypads ......................................................................... 25
5. AC-425x-B Hardware Settings..........................................................27
5.1 DIP Switch Configuration............................................................................ 27
5.2 AC-425x-B Panel Baud Rate........................................................................ 28
5.3 AC-425x-B Panel Type................................................................................. 28
5.4 AC-425x-B Panel Address ........................................................................... 30
6. Communications .............................................................................32
6.1 Serial Network Connection......................................................................... 32
6.1.1 RS-232 Connection to the Computer ..................................................................... 33
6.1.2 RS-485 Connection to the Computer ..................................................................... 33
6.1.3 Daisy Chaining ....................................................................................................... 34
6.2 TCP/IP Network Connection....................................................................... 35
6.2.1 LAN and WAN Requirements................................................................................. 35
6.2.2 LAN and WAN Requirements................................................................................. 36
A. Declaration of Conformity...............................................................37
B. Radio Equipment Directive (RED) ....................................................38
C. RoHS Directive.................................................................................39
D. Limited Warranty ............................................................................40

List of Figures
AC-425x-B Series Hardware Installation and User Manual v
List of Figures
Figure 1: AC-425x-B Panel Layout ............................................................................. 9
Figure 2: Sample AC-425x-B Configuration ............................................................. 12
Figure 3: Inputs Wiring – Non-supervised Inputs.................................................... 13
Figure 4: Door Lock – Failed Close........................................................................... 14
Figure 5: Door Lock – Failed Open .......................................................................... 15
Figure 6: Wiring Between PM-10 and AC-425x-B.................................................... 16
Figure 7: AC-425x-B Wiring Communications ......................................................... 17
Figure 8: Reader Wiring .......................................................................................... 18
Figure 9: Connector Location for MD-IO84B or MD-D04B Expansions ................... 18
Figure 10: Normally Open Input Connection .......................................................... 19
Figure 11: Normally Closed Input Connection......................................................... 20
Figure 12: Normally Open Supervised Input (Single Resistor)................................. 20
Figure 13: Normally Open Supervised Input (Double Resistor)............................... 21
Figure 14: Normally Closed Supervised Input (Single Resistor)............................... 21
Figure 15: Normally Closed Supervised Input (Double Resistor)............................. 22
Figure 16: DIP Switches ........................................................................................... 27
Figure 17: RS-232 Panel Connection to PC .............................................................. 33
Figure 18: RS-485 Panel Connection to PC .............................................................. 33
Figure 19: Daisy Chaining ........................................................................................ 34
Figure 20: MD-N32 Configuration Connecting a Single Panel ................................. 35
Figure 21: Connecting a Single Control Panel with MD-N32 ................................... 36
Figure 22: Connecting Multiple Access Control Panels with MD-N32..................... 36

List of Tables
vi AC-425x-B Series Hardware Installation and User Manual
List of Tables
Table 1: DIP Switches and Their Functions.............................................................. 27
Table 2: Switch Baud Rates ..................................................................................... 28
Table 3: Possible Hardware Settings ....................................................................... 28
Table 4: Available Panel Addresses ......................................................................... 31
Table 5: RS-232 Connection .................................................................................... 33

Notice and Disclaimer
AC-425x-B Series Hardware Installation and User Manual vii
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient
installation and usage of the system and/or product, and/or software described herein.
BEFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM,THE INSTALLER AND THE USER MUST
READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING
PROCEDURES.
The system must not be used for purposes other than those for which it was
designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the
purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all
functions described in this manual may be available in the specific system
and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any
responsibility for consequent non-compliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose of
illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary, or punitive damages (including, without
limitation, any and all damages from business interruption, loss of profits or
revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between the
image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding
of the product and may differ from the actual PCB(s).

Introduction
8 AC-425x-B Series Hardware Installation and User Manual
1. Introduction
In this manual
, unless otherwise stated, “AC-425x-B” refers to both the regular AC-
425
-B and the AC-425IP-B models.
The AC-425x-B access control panel is a state-of-the-art networked access
controller, employing the latest technology to meet the requirements of the
market.
The state-of-the-art dual/quad door AC-425x-B networked access controller is the
backbone of medium scale security systems handling up to 30,000 users and 8184
doors.
Each AC-425x-B access control unit (ACU) supports four readers (In/Out) of various
formats including standard Wiegand 26-bit. Installations can also have one reader
per door.
The AC-425x-B comes in two models:
AC-425-B – standard model
AC-425IP-B – supports TCP/IP connection
Driven by Rosslare’s powerful, flexible, and easy-to-use AxTraxNG™ or AxTraxPro™
Access Control Management Software, the system provides an ideal, modular, and
expandable solution for commercial and institutional needs. It provides seamless
integration with Rosslare's range of RFID proximity, PIN, Proximity & PIN,
smartcard, and biometric readers with Rosslare’s selection of RFID credentials.
The AC-425x-B is ready for installation with a mountable & lockable metal
enclosure integrated with transformer, power supply/charger, sounder and control
board.
Using onboard RS-232/485, Ethernet TCP/IP (AC-425IP-B model only), multiple
local or remote sites, door sub-networks can connect to the AxTrax NG/AxTraxPro
Access Control Management Software running on Microsoft®Windows®98/ME &
NT/2000/XP/7 operating systems.
The AC-425x-B consists of the following components:
AC-425x-B controller board
Panel enclosure
PM-10 management board
Power transformer
4 x 2.2 kΩand 4 x 8.2 kΩresistors for the supervised inputs

Technical Specifications
10 AC-425x-B Series Hardware Installation and User Manual
2. Technical Specifications
2.1 AC-425x-DIN
Electrical Characteristics
Operating Voltage
12 VDC, 1.5 A from a regulated power supply
Maximum Input Current AC-425
Standby: 80
mA
Maximum: 325 mA
AC-425IP
Standby: 120
mA
Maximum: 370 mA
General Inputs •4 supervised high impedance inputs
•8 or 12 supervised inputs when using MD-D04B or
MD-IO84B expansion boards
•Maximum voltage: 5 VDC
Relay Outputs •4 Form C 5 Amp relay outputs
•8 outputs when using MD-D04B or MD-IO84B
expansion boards
Reader Ports •4 reader ports, 8 reader ports when using
MD-D04B
•Communication: Wiegand (D0, D1) or Clock &
Data (C, D)
•Output voltage to reader: 12 VDC
•Max. current to reader: 245 mA
•
LED control output and Tamper Input
Visual Indicators
11 LEDs for outputs and communication status
Audio Sounder output for use with compatible speakers
provides chime, bell, and siren signals
Battery Standby Time
3 hours with a 12 V, 7 Ah lead acid battery
Communication Characteristics
RS-485 / RS-232 •RS-485 or optional RS-232
•RS-485 connection by terminal block or MD-14U
connector
•RS-232 connection by terminal block
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP On-board RJ-45 connector
(functional on AC-425IP models only)
Selectable Communication Speed
9600, 19200, 57600, 115200 bps

Technical Specifications
AC-425x-B Series Hardware Installation and User Manual 11
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Dimensions
Height x Width x Depth
193 x 136.5 x 39 mm (7.6 x 5.4 x 1.5 in.)
Weight
0.36 kg (12.7 oz)
2.2 AC-425x-B Installed in ME-1015
Electrical Characteristics – Switch Mode Power Supply
Operating Voltage
90 ~ 265 VAC, 50 ~ 60 Hz from mains power
Maximum Input Current
1.5 A
Output Power 15 VDC, 4 A (60 Watts) to the power
management board
Electrical Characteristics – Power Management Board (PM-10)
Input Power
15 VDC, 4 A to the power management board
Output Power Two PTC fused outputs, each provides 13.8 VDC,
2 A
One output for controller and readers
One output for locks
Battery Charger 13.8 VDC, 300 mA for 12 VDC, 7 Ah Lead Acid
Battery
Speaker
0.5 Watt, 8 Ohm
Light Bar
0.3 Watt for LED light
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Dimensions
Height x Width x Depth
364 x 264 x 87.4 mm (14.3 x 10.4 x 3.4 in.)
Weight
3.4 kg (7.5 lb)

AC-425x-B Panel Setup
12 AC-425x-B Series Hardware Installation and User Manual
3. AC-425x-B Panel Setup
Each AC-425x-B panel controls 2 or 4 doors (up to 8 doors with MD-D04B). The
panels connect together in a network and are controlled by a central server
computer, running the AxTraxNG/AxTraxPro Access Control Management
Software.
Figure 2 shows an example setup for a network of AC-425x-B access control panels.
Figure 2: Sample AC-425x-B Configuration
Bushings are needed for any conductors leaving the enclosure through the
provided openings
.

AC-425x-B Panel Setup
14 AC-425x-B Series Hardware Installation and User Manual
3.2 Inputs Wiring – Supervised Inputs
When wiring the AC-425x-B for supervised inputs, resistors should be placed on
the input switch and not on the terminal block.
For more details, refer to Chapter 4.
3.3 Outputs Wiring
Figure 4 and Figure 5 illustrate wiring for two main types of 12 VDC electrical
release mechanisms. Other electrical devices can be switched using the voltage
free relay contacts.
Figure 4: Door Lock – Failed Close

AC-425x-B Panel Setup
AC-425x-B Series Hardware Installation and User Manual 15
Figure 5: Door Lock – Failed Open
3.4 Power Supply
Figure 6 illustrates wiring between the PM-10 power management board and the
AC-425x-B. Make sure the connection polarity is correct, (+) to (+) and (-) to (-).
Connect the power to the input power terminals of the control panel. It is
recommended to add a 12 VDC lead acid backup battery (requires the ME-1015
Power Management Enclosure) to have uninterrupted operation in case main
power supply fails. A 12 V, 7 AH battery provides 3 hours of backup operation.

AC-425x-B Panel Setup
16 AC-425x-B Series Hardware Installation and User Manual
Figure 6: Wiring Between PM-10 and AC-425x-B

AC-425x-B Panel Setup
AC-425x-B Series Hardware Installation and User Manual 17
3.5 AC-425x-B Wiring Communications
Figure 7 presents a detailed view of the access control panel with all its necessary
wiring for communications.
Figure 7: AC-425x-B Wiring Communications
3.6 Readers
Proximity and keypad readers are supplied with a limited cable. The color of the
cable cover represents the cable’s function according to Wiegand standards
(Figure 8).
When extending the cable distance, be careful with the color of the cable cover.
Refer to the reader specifications for the maximum cable length (typically 150 m
with an 18 AWG cable).

AC-425x-B Panel Setup
18 AC-425x-B Series Hardware Installation and User Manual
Figure 8: Reader Wiring
3.7 MD-IO84B
The MD-IO84B is an optional I/O expansion board that adds 4 relay outputs and 8
supervised inputs to the Access Control Panel. Attach the MD-IO84B to the AC-
425x-B's expansion slot, as marked in red in Figure 9).
Figure 9: Connector Location for MD-IO84B or MD-D04B Expansions
For more information, see the MD-IO84B Installation and User Guide.
3.8 MD-D04B
The MD-D04B is an optional reader expansion board that adds 4 readers, 4 relay
outputs and 4 supervised inputs to the access control panel. Attach the MD-D04B
to the AC-425x-B's expansion slot, as marked in red in Figure 9.
For more information, see the MD-D04B Installation and User Guide.

Input and Output Connections
AC-425x-B Series Hardware Installation and User Manual 19
4. Input and Output Connections
This chapter describes the AC-425x-B access control panel's input and output
connections.
4.1 Input Types
There are four input types:
Normally Closed (N.C.)
Normally Open (N.O.)
Single EOL resistor
Double EOL resistor
Inputs IN1, IN2, IN3, and IN4 may be configured individually as either supervised or
non-supervised inputs. Use the AxTraxNG/AxTraxPro Access Control Management
Software to configure each input separately.
Non-supervised inputs have two states:
Normal
Abnormal
Supervised inputs have three states:
Normal
Abnormal
Trouble
The Trouble state is caused by either tampering with the input circuit or by faulty
hardware installation. Once an input is configured as a supervised input, add a
resistor of 2.2 kΩ, of 8.2 kΩ, or both on the input circuit. See the following
diagrams.
4.1.1 Normally Open Input Connection
A Normally Open Input has 2 states:
Switch Open – Normal State:
Loop resistance = Infinite (open circuit)
Switch Closed – Abnormal State:
Loop resistance = 0 (short circuit)
Figure 10: Normally Open Input Connection

Input and Output Connections
20 AC-425x-B Series Hardware Installation and User Manual
4.1.2 Normally Closed Input Connection
A Normally Closed Input has two states:
Switch Closed – Normal State:
Loop resistance = 0 (short circuit)
Switch Open – Abnormal State:
Loop resistance = Infinite (open circuit)
Figure 11: Normally Closed Input Connection
4.1.3 Normally Open Supervised Single EOL Resistor Input Connection
Connect an 8.2 kΩresistor in parallel to the input switch contacts.
A Normally Open Supervised Input has 3 states:
Switch Open – Normal State:
Loop resistance = 8.2 kΩ
Switch Closed – Abnormal State:
Loop resistance = 0 (short circuit)
Open circuit across input terminals – Trouble State:
Loop resistance = Infinite (open circuit).
Figure 12: Normally Open Supervised Input (Single Resistor)
This manual suits for next models
2
Table of contents
Other Rosslare Control Panel manuals

Rosslare
Rosslare AC-215-Bx Guide

Rosslare
Rosslare AC-225-B Series Manual

Rosslare
Rosslare AC-425x-B Series User manual

Rosslare
Rosslare MD-IO84B User manual

Rosslare
Rosslare HLX-40 Assembly instructions

Rosslare
Rosslare MD-D02B User manual

Rosslare
Rosslare AuraSys L-4 Assembly instructions

Rosslare
Rosslare AC-425-B User manual

Rosslare
Rosslare HLX-24TH Series User manual

Rosslare
Rosslare AC-020 User manual