Elmes Electronic STM-2K VER 4 User manual

TWO OUTPUTS MINIATURE RADIO CONTROL 230VAC RECEIVER STM-2K VER 4
Elmes Electronic STM-2K VER 4 controller is designed
for remote control of two devices powered with 230VAC such
as domestic hot water circulating pump, etc. Miniature size of
the controller allows its installation in electric cable installa-
tion boxes (wall plaster type –60mm deep). The receiver in-
cludes the KEELOQ
®
hopping code system of Microchip
Technology Inc., USA allowing high level of security.
STM-2K VER 4 receiver is compatible with all Elmes Elec-
tronic hand transmitters operating at 433,92 MHz. Each of
transmitter’s two buttons control one of two controller’s out-
puts. In case of 4 buttons transmitter, active button pairs are
1-2 or 3-4. Unused pair may control other equipment.
The controller may be wired operated by two single mono-
stable wall switches or one double. Wired switches control
the unit the same way as the hand transmitters.
Each output of the receiver is independent and may be pro-
grammed to operate in one of the following 2 modes:
Mode 1: Pressing the remote control button activates the
output to be in permanent ON position. The output will turn
OFF only when power is turned off (point 2 programming
procedures).
Mode 2: Pressing the remote control button activates the
output for a preset time. Pressing the button while the output
is switched ON extends this time. The default activation time
is a few seconds and should be changed according to re-
quirements (paragraph 3 programming procedures).
Fig.1. Control buttons layout in Elmes Electronic hand
transmitters.
SPECIFICATION
power supply 230VAC (0,3VA standby, 0,5VA on any relay on),
output relays rating: 250VAC~ 5A max.,
superheterodyne receiver to 433,92MHz band,
controller’s memory for up to 112 transmitters,
control voltage at inputs no 6 and 7: 250VAC~ max.,
programmed timing: 0,5s up to 4h,
operating temperature range -20 up to +55ºC,
external dimensions (l/w/h) 42/35/21mm.
Manufacturer: ELMES ELECTRONIC,
ul. Avicenny 2, 54-611 Wroclaw, Poland,
tel. (+48)717845961, fax (+48)717845963
PROGRAMMING PROCEDURES
The PRG button is used for programming of the controller.
The LED diode indicates the
status of the programming
sequence. LED slow flashing
(one per second) indicates
correctly performed proce-
dure. Fast flashing (four per
second) indicates proce-
dures made incorrectly or
procedure error. Program-
ming procedures, except for
procedure point 2b and 3c,d, are allowed 16 seconds to be
completed. After that time the controller automatically exits
programming mode and indicates programming error.
1. LEARNING TRANSMITTER/S to controller memory (up
to 112 maximum):
a) press PRG switch for less than 2 seconds (LED lights
on). Releasing the switch LED continues to light indicat-
ing entering programming mode,
b) press appropriate transmitter’s button once (button num-
ber 1 or 2 for control pair 1-2, button number 3 or 4 for
control pair 3-4) - LED switches off.
c) press the same transmitter’s button second time - end of
procedure
2. MODE 1 PROGRAMMING PROCEDURE (see above):
d) press and hold PRG switch for longer than 2 and shorter
than 8 seconds. Releasing the switch sets the LED off,
e) press shortly three times programmed transmitter’s but-
ton or wall switch.
3. MODE 2 PROGRAMMING PROCEDURE (see above):
f) press and hold PRG switch for longer than 2 and shorter
than 8 seconds. Releasing the switch sets the LED off
g) press hand transmitter button or wall switch once –the
LED lights ON and the output sets ON,
h) when the desired time has elapsed (from 0,5 second up
to 4,5 hours) press the transmitter’s button or wall switch
again
i) after 2 seconds the LED starts blinking slowly confirming
end of procedure
4. DELETING ALL TRANSMITTERS in controller’s
memory. Procedure suitable in case one of transmitters
is stolen or lost: Press and hold PRG switch over 8 sec-
onds until LED starts flashing and then release it. The
controller’s memory is now cleared of all transmitters,
however programmed modes and timing remain un-
changed. To operate the controller by new hand trans-
mitter/s, perform point 1.
5. DELETING ONE TRANSMITTER in controller’s
memory. This operation is possible under condition that
the transmitter to be deleted is in our possession. Start
the procedure as in point 1a) and follow steps by press-
ing two different buttons of the transmitter. LED indi-
cating error in this case means the transmitter is now de-
leted and will no longer operate the controller. Status of
all other transmitters learned to the controller remains
unchanged.
NOTE: procedure point 2 and 3 is possible with the wall
switch or programmed hand transmitter.
elmes
electronic

INSTALLATION (see connection schematic diagram below):
The controller is not water sealed and should be installed in
dry place. Antenna wire should be let loose downwards (not
glued or fitted to ground), if possible. Care should be taken
not to expose the control unit to harsh environmental condi-
tions such as very low/high temperatures or high humidity.
The unit includes radio receiver thus any metal screening or
interference with other electric/radio equipment operating in
close distance should be avoided as may seriously shorten
practical operating range in wireless operating mode. When
installing the controller in electric junction box (in wall) care
should be taken to properly lay connecting wires avoiding
crossing with antenna wire. The antenna wire should be laid
in circular way and tested for obtaining maximum operating
range with the use of hand transmitter/s.
Description of connection terminals:
1 –230VAC mains LIVE output for channel number 1,
2 –common NEUTRAL output for channels 1 and 2,
3–230VAC mains LIVE output for channel number 2,
4 -230VAC mains LIVE supply input (!),
5 -230VAC mains NEUTRAL supply input (!),
6–wired wall switch input for channel 1 (LIVE!),
7–wired wall switch input for channel 2 (LIVE!),
(!!!) WARNING: It is important to connect mains supply
LIVE wire to terminal 4 and NEUTRAL wire to terminal 5
of the controller.
Manufacturer’s Limited Warranty:
Elmes Electronic products carry two year manufacturer’s warranty as
from date of purchase. The warranty is limited to the replacement of
faulty original parts or repair defects of improper manufacture. Dam-
age, faulty use or improper handling by the user or installer as well
as any changes in product’s hardware or software caused by the
user violets the warranty and all due repair costs will be charged.
Elmes Electronic shall not be responsible for any damage human or
material caused by its products failure to operate correctly.
Elmes Electronic reserves the right to change product specification
without prior notice.
KEELOQ
®
is a registered trademark of Microchip Technology Inc.
WARNING! Do not open the product plastic case. Warranty
void if seal broken.
DEKLARACJA ZGODNOŚCI
DECLARATION OF CONFORMITY
Manufacturer: Elmes Elektronik
declare under sole responsibility that its products:
RADIO CONTROL 230VAC RECEIVER
type: STM-2K ver 4
comply with essential requirements of the following directives:
1999/5/EC (R&TTE),
2004/108/EC (EMC),
2006/95/EC (LVD),
and applied harmonized standards, in particular:
EN 60950-1:2006 –(electric safety),
EN 61000-6-1:2007 EMC, (immunity),
EN 61000-6-3:2007 EMC, (emission),
EN 301 489-1 V1.8.1 (2008-04) EMC, (radio devices),
EN 301 489-3 V1.4.1 (2002-08) EMC, (SRD),
EN 300 220-1 V2.3.1 (2010-02), EMC, (ERM)
Manufacturer:
ELMES ELEKTRONIK, ul. Avicenny 2, 54-611 Wrocław, Poland
tel (+48)717845961, faks: (+48)717845963
Podpis / Signature: ............................................
Dyrektor - Mirosław Bińkowski
Data/Date: 2014-12-04
The use of WEEE symbol indicates that this product cannot be
treated as house hold waste. By ensuring this product is disposed of
correctly you will protect the environment. For more detailed infor-
mation about the recycling of this product, please contact your local
authority, your household waste disposal service provider or the
shop where you purchased the product.
WARNING! Control unit and electric connection to
230VAC mains voltage require personal safety precau-
tions to be taken and mains voltage line be in OFF state
at installation.
Other Elmes Electronic Controllers manuals
Popular Controllers manuals by other brands

EXAIR
EXAIR EFC Installation and Maintenance

ASCENTO
ASCENTO RPC-15007 Owner's operation manual

Full Gauge
Full Gauge TC-900 E Operation manual

Mitsubishi Electric
Mitsubishi Electric MELSEC-F FX3U-232ADP-MB installation manual

Aruba
Aruba 7280 installation guide

Sentera Controls
Sentera Controls RMFPX-2R Mounting and operating instructions