2080E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
10/16 Page 1 of 2 Version 1.0
Power Input and Fault Alarm Contact Wire Gauge: 12–24 AWG RJ-45.
Port Connection: Use four twisted pair Cat 5, 5e, or 6 cables less than 100 meters long.
NOTE This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or
non-hazardous locations only.
WARNING – EXPLOSION HAZARD!
• Donotdisconnectequipmentwhilethecircuitisliveunlesstheareaisknowntobefree
ofignitableconcentrations.
• Donotdisconnectequipmentunlesspowerhasbeenremovedortheareaisknowtobe
non-hazardous.
• SubstitutionofanycomponentsmayimpairsuitabilityforClassI,Division2.
• Theareamustbeknowntobenon-hazardousbeforeservicingorreplacingtheunitand
beforeinstallingtheunit.
WARNING Exposure to some chemicals may degrade the sealing properties of materials used
in the sealed relay device. It is recommended to inspect the sealed relay device periodically
and to check for any degradation of the materials and replace the complete product (not the
sealed device) if any degradation is found.
Terminal Block for Power 1,
Power 2 and Fault Alarm Contact
RS-232 Console Port
10/100 TX RJ-45 Ethernet Ports (8)
1. Insert DC power wires into the contacts for Power Supply 1 and 2.
2. Tighten the terminal screws to ensure that the wires do not come loose.
Power Supply 2*
Power Supply 1
*Power Supply 2 is used for
redundant supplies.
Surge EARTH
POWER SUPPLY WIRING
DC Power Input Range:
12VDC–48VDC
FAULT CONTACT WIRING
2080E-T
2080E-T
Surge EARTH
FAULT ALARM
CONTACT 1A@24V
N/C Contact
Contact will open
when a fault occurs
DC
DC