u::Lux NetCon User manual

u::Lux NetCon & u::Lux NetCon Power
Manual
www.u-lux.com
office@u-lux.com
Tel: +43/66 /450 351-13
Fax: +43/66 /450 351-16
u::Lux GmbH
Rechtes Salzachufer 4
50 0 Salzburg
Austria

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
/
10
Contents
General Information ................................................................................................................................................... 3
Mounting ................................................................................................................................................................... 3
Mounting order .......................................................................................................................................................... 5
Startup ....................................................................................................................................................................... 5
Startup order .............................................................................................................................................................. 5
Practical example ....................................................................................................................................................... 6
Network wiring .......................................................................................................................................................... 7
Technical Data............................................................................................................................................................ 8
Hazard warnings ........................................................................................................................................................ 9
CE – marking ............................................................................................................................................................. 9
Guarantee................................................................................................................................................................... 9
Ordering Information ................................................................................................................................................. 9
Version Management ................................................................................................................................................10

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
3
/
10
General Information
The u::Lux NetCon or u::Lux NetCon Power is a 4 port, 100-Mbit/s-Ethernet Switch. The 4 ports are
equipped with RJ45 jacks and have the designation LAN1 – LAN4. LAN1 and LAN serve for
connecting up to 10 u::Lux Switches RJ45. LAN3 and LAN4 are generally used for connections to the
control centre or the computer.
The following details apply equally for the u::Lux NetCon and u::Lux NetCon Power, except in case
of an explicit distinction between the models.
The energy supply of the u::Lux NetCon is carried out via direct voltage through the connections –
VCC and +VCC. The voltage has to be sufficiently filtered (max. voltage ripples V
SS
) and it must be
within the following range:
u::Lux NetCon
48V DC
u::Lux NetCon Power
V
–
30V DC
Mounting
The mechanical assembly of the u::Lux NetCon is effected on a 35mm top-hat rail which has to be
mounted horizontally. Therefore a flap is provided on the bottom part of the housing. If the flap is
pulled forwards (screwdriver) the u::Lux NetCon can be easily placed on the top-hat rail.

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
4
/
10
The installation width is 35mm. There are ventilation slots on the top and the bottom of the
housing which provide heat exchange. Please note that these vents are not covered and a sufficient
distance to adjacent components is kept.
The housing height is approx. 80mm. Please note that for the Ethernet-connections (on the front)
there will be added approx. 50mm additionally to the housing depth. Altogether a free installation
depth of approx. 130mm is necessary. Please take this into consideration when selecting an
appropriate junction box (wall cabinet).

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
5
/
10
Mounting order
1. u::Lux NetCon or u::Lux NetCon Power must snap into place on the top-hat rail.
2. Connect the network cable (not included in the scope of delivery) for the u::Lux Switch RJ45
to LAN1 or/and LAN .
We recommend the use of a Patchpane (taking into account the potentia equa ization) so
that a shie ded network cab e can be ead to ground or to get a better ground-contact from the
insta ation cab e to the Patch cab e. When indicated, a ready existing oca connecting
instructions must abso ute y be obeyed.
3. For the control or cascading connect the network cable (not included in the scope of
delivery) to LAN3 or/and LAN4.
4. Connect the energy supply.
A plug connector (Phoenix - MSTBA ,5/ -ST-5,08) is included in the scope of delivery.
Connect the negative supply voltage of the energy supply to Pin – VCC and the positive
supply voltage to +VCC (see Chapter General Information).
Startup
After connecting the power supply all green LEDs have to illuminate. With these LEDs the presence
of the following voltages is indicated:
1. Energy supply with supply voltage VCC.
2. Internal voltage generation 3,3 vo ts.
3. Internal voltage generation 48 vo ts (on ports LAN1 and LAN ).
If a network cable is connected to each of LAN1 – LAN4 and a physical connection (LINK) is
established, the corresponding yellow LED illuminates permanently. As soon as there is traffic on
the connection (ACTIVITY) it will be signalized by this flashing LED. Regarding the LAN ports we
recommend the connection of the following network subscribers:
LAN1: is used exclusively to connect up to 10 u::Lux Switches RJ45.
LAN : is used exclusively to connect up to 10 u::Lux Switches RJ45.
LAN3: is used to connect a PLC control or to connect another u::Lux NetCon Power module
(cascading) or a computer.
LAN4: is used to connect a PLC control or to connect another u::Lux NetCon Power module
(cascading) or a computer.
Startup order
1. Control of the green LED. All 4 LEDs have to illuminate.

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
6
/
10
2. Control of the yellow LED. Depending on the connected network subscriber and depending
on the traffic the LEDs illuminate or flash. The yellow LED must not illuminate or flash on
an unoccupied port (LAN1 – LAN4).
Practical example
The installation and energy supply of 40 u::Lux Switches RJ45 is required. All u::Lux Switches RJ45
shall be connected to a control.
A maximum of x10 u::Lux Switches RJ45 per u::Lux NetCon Power can be supplied with energy.
Therefore units of u::Lux NetCon Power are required for the energy supply of all 40 u::Lux
Switches RJ45.
The u::Lux Switches RJ45 are connected to the ports LAN1 and LAN of the u::Lux NetCon Power.
Both ports of LAN3 are connected to each other (cascading). One of the two LAN4 ports forms the
connection to the control (PLC); the other one can be used for a connection to a computer.
If you use more than u::Lux NetCon Power modules, we recommend to wire the supply
connections separate to the power supply and not together as shown in the image.

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
7
/
10
Network wiring
An u::Lux Switch line may not exceed the total length of 00 m because of the cable resistance
(voltage drop). We recommend not exceeding the max. length of 50 m of a single sub segment.

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
8
/
10
Technical Data
Supp y : Direct voltage with a ripple of max. V
SS
u::Lux NetCon
48V
u::Lux NetCon Power
V
-
30V
Power consumption: max. 1,5W (without connection of u::Lux Switch RJ45)
max. 48 W (with connection of x 10 pieces of u::Lux Switches RJ45)
Connections: 1 x supply (+VCC or –VCC, Phoenix MSTB ,5/ -ST-5,08
x Ethernet RJ45 jacks with 48V supply (LAN1 and LAN -> each
via Pins 4+5 [–VCC] and 7+8 [+VCC])
x Ethernet RJ45 jacks without 48V supply (LAN3 and LAN4)
1 x ground connection (via metal bracket on the bottom of the
housing)
Disp ays: At the network connections per port there is a yellow LED for
„LINK“ or “ACTIVITY” and respectively a green LED for displaying
the voltages VCC, 3V3 und x 48V.
Network: 100BaseT
Ambient temperature: -10 °C to +40°C
Storage temperature: -30 °C to +80°C
Protection type: IP30
Protection c ass: III
Assemb y type: Vertical on horizontal top-hat rail (35mm)
Insta ation dimensions: 95mm x 35mm x 76mm
Housing materia s: UPPER PART: synthetic mat. LEXAN UL94-V0, self-extinguishing
Colour: RAL 7035 light grey
Ambient temperature: up to +100°C
LOWER PART: synthetic mat. NORYL UL94-V0, self-extinguishing
Colour: RAL 70 1 black-grey
Temperature range: up to +100°C
FOIL: made of polyester DIN 4 115, fine grained
Foil with sanded look, horizontal sanding direction

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
9
/
10
Hazard warnings
Attention! Assembly and installation of electrical devices may only be performed by a qualified
electrician. Strictly observe the prevailing accident prevention measures. Failure to observe the
installation instructions may result in damage to the device, fire or other dangers.
u::Lux NetCon or u::Lux NetCon Power are devices which do not correspond to the PoE standard.
CE – marking
The CE marking is exclusively addressed to the governmental supervising authorities of the
Member States and facilitates the free movement of goods. The CE marking does not represent any
guarantee of specific features.
Guarantee
The guarantee complies with the statutory requirements. Technical changes and error reserved.
Ordering Information
u::Lux NetCon Power order number 1096
u::Lux NetCon order number

u::Lux NetCon / u::Lux NetCon Power - Manual
Version:
1.0
7
01.10
. 01
4
Page
:
10
/
10
Version Management
Version
Date
Name
Notes
1.00
1 .1
.
0
1
KH
Creation of the document
1.01
17.1 . 01
THSI
Correction
/
Release
1.0
18.1 . 01
AK
Correction/Release
1.03
14.01. 013
KH
Addition
(
Network connections via p
atchpanel
)
1.04
1.01. 013
KH
Addition
(
Connections
)
1.05
14.01. 014
THSI
Addition
of new order numbers
1.06
07.07. 014
KH
u::Lux switch
-
> u::Lux switch RJ45
1.07
01.10. 014
AK
Contact updated
This manual suits for next models
1
Table of contents