Features
Supply voltage 240VAC (also available in 110-120VAC
supply for international markets)
Din rail mountable case
Two optically isolated inputs for manual control
Time clock with automatic daylight saving control
Antenna diversity for robust link with extended range
Unlimited remotes can be programmed to the receiver
Compatible with PentaFOB® and PentaCODE® remotes
Momentary, latching and timer modes are user selectable
On-board diagnostic LED’s to indicate correct power,
reception and relay activation
Applications
Automatic 24 hour time clock switching on and off
Automatically open and close gates with a time clock
Home automation i.e. garden lights, swimming pool control etc
Security lighting
…. and anywhere else you need a time clock or wireless signal to
activate a contact closure
Description
Powered by top-grade components and technologies, the PentaTimer receiver has a built-in 24 hour 7 day time
clock that can store 50 programs. It can be programmed to switch "on" and "off" each of its relays based on a
time clock, isolated inputs or with the PentaFOB®” and “PentaCODE® remote controls.
The time clock is powered by its own lithium battery and therefore does not lose the time and programs when
the receiver is disconnected from the supply.
With features such as 240VAC supply connection, receiver frequency hopping, unlimited remote storage, din
rail mountable case and automatic daylight saving adjustment, this receiver makes it easy to install wireless
switching functions with time clock controls.
Output Modes
Relay output modes on the receiver are user selectable. By default the mode is set to momentary.
Factory Default = Momentary
Momentary - Output is "on" for as long as any of the inputs are held active.
Latching - Output remains "on" until next input is activated.
Similar to switching "on" and "off" a light.
On Time - Once activated, the relay remains "on" for the set time. Adjustable from 1 - 600sec.
Each relay can be adjusted independently.
Timer - Each relay can be switched "on" and "off" based on real time clock.
Function For example: Switch "on" lights at 8pm and "off" at 6am weekdays only.

ELSEMA
2 Channel, Penta Receiver with Time Clock
Customised Software
Custom output modes can be programmed to do special functions. Call Elsema for more details.
Relay Output Modes of PCR43302240T
Each channel output has its own 2-way dipswitch and an ON time trimpot for mode selection.
Mode Settings
The output relay will respond in the following manner when receiving an input signal
Momentary
Relay is on while correct signal is received. (see note below)
Latching
Relay alternates at every correct incoming signal.
Similar to switching "on" and "off" a light.
On Time Low Scale
Relay remains "on" for 1 - 60 seconds, adjustable by trimpot.
On Time High Scale
Relay remains "on" for 60 - 600 seconds (1- 10 Minutes), adjustable by
trimpot.
Note: In momentary mode, if the time clock activates and holds the output "on", any signal from the remote or
the local input is ignored.

ELSEMA
2 Channel, Penta Receiver with Time Clock
Products in the Range
PCR43301RE
1-Channel Receiver with
Relay Output. Enclosed
in a case
PCR43302P
2-Channel Plug in type
Receiver with Open
Collector Output
PCR43302R
2-Channel Receiver with
Relay Outputs
PCR43302RE
2-Channel Receiver with
Relay Outputs. Enclosed
in a case
PCR43301240R
1-Channel Receiver with
240VAC mains supply
PCR43301240RE
1-Channel Receiver
enclosed in an IP66 case
PCR43302240R
2-Channel Receiver with
240VAC mains supply
PCR43302240RE
2-Channel Receiver
enclosed in an IP66 case
PCR43304R
4-Channel Receiver with
Relay Outputs
PCR43304RE
4-Channel Receiver
enclosed in an IP66 case
PCR43305R
5-Channel Receiver with
Relay Outputs
PCR43305RE
5-Channel Receiver
enclosed in an IP66 case

ELSEMA
2 Channel, Penta Receiver with Time Clock
Technical Data
Supply Voltage
240 Volts AC Mains. (110-120VAC supply for international markets)
Frequencies
433.100 to 434.700MHz
Receiver Sensitivity
Better than 0.316uV (-117dBm)
Operating Temperature Range
-5 to 50°C
Receiver Memory Storage
Unlimited Remotes
Decoding System
Encrypted 17 billion codes combinations or On board 12-way code switch
Outputs
2 Change over relay outputs, rated at 16 Amps at 240VAC each.
Inputs
2 Inputs for local trigger.
Relay Contacts
Common (C), Normally Closed (NC) & Normally Open (NO)
Connections
Screw type terminal block for antenna, supply and relay outputs.
Inputs are plug-in type terminal block
Antenna
ANT433 series for long range applications. Antenna wire for short range
applications.
Operating Range
Refer to the remote control or transmitter datasheet
Dimensions
145 x 100 x 40 mm
Weight
330 grams
Useable Transmitters
FOB433 and PCK series.

ELSEMA
2 Channel, Penta Receiver with Time Clock
Block Diagram
PCR43302240T
Remove 4-screws in the lid to set the 12-way dip switch and to connect a programming cable to the
program socket. The program socket is used to connect the Elsema PentaFOB programmer to add, edit,
delete remotes and to activate tools, special features and modes.
Time clock uses a CR2032 lithium battery for backup.

ELSEMA
2 Channel, Penta Receiver with Time Clock
PentaFOB®Programming Instructions
Coding the PentaFOB® remotes and receivers can be done in 2 different ways.
1. Using the Receiver
2. Using another Remote Control
Coding using the Receiver
1. Check that all switches are “OFF” on the receivers 12-way dip switch
2. Press and hold the program button on the receiver
3. Press the remote button for 2 seconds, receiver LED will
flash and then turn Green
4. Release the button on the receiver and the remote
5. Press remote control button to test the receiver output
Coding using another Remote Control
1. Open the case of a remote control that is already programmed and
press and release the program button on the back of the board
2. Press the new remote control button for 2 seconds
3. Press the new remote control button again to test the receiver output
Deleting Receivers Memory
Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver’s
memory.
PentaFOB® Programmer
This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a
remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access.
PentaFOB® Backup Chips
This chip is used to backup or restore the contents of a receiver. When there are 100’s of remotes programmed
to a receiver the installer normally backups the receiver memory in case the receiver is damaged.

ELSEMA
2 Channel, Penta Receiver with Time Clock
PentaCODE Programming Instructions
12- Way Dip Switch Coding
1. Set a random code on the receiver dip switch by flicking the dip switches "On" or "Off".
(DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12-WAY DIP SWITCH AS THIS
IS A COMMON CODE)
2. Open the battery cover in the PentaCODE® remote.
3. Match the 12-way dip switch to the receivers 12-way dip switch.
4. Press button 1 on the remote and the receiver output should activate. This is indicated by the receiver
LED.
To program the same PentaCODE® remote buttons 2, 3 or 4 to another receiver change dip switch 11 and 12 in
the 2nd, 3rd and 4th receivers. For example:
Receivers Dip Switch 11 Receiver Dip Switch 12
Receiver 1 Off Off
Receiver 2 On Off
Receiver 3 Off On
Receiver 4 On On
Dip switches 1 to 10 should all be the same in the remotes and the receivers.
Encrypted Coding - (All 12-Way Dip Switches must be "Off")
Coding the PentaCODE® remotes and receivers can be done in 3 different ways.
3. Receiver to a Remote
4. Remote to a Receiver
5. Remote to a Remote
Receiver to a Remote
1. Press and hold the program button 1 on the receiver.
2. Press the remote button you want to program for 2 seconds, receiver LED will flash Green
3. Release the button on the receiver and the remote.
4. The LED on the PentaCODE® remote will flash to confirm the coding has been successful.
Remote to a Receiver / Remote to a Remote
Set one of the remotes or receivers to broadcast its code. The broadcaster’s code will be programmed to the
other units.
- To broadcast the remotes code make sure all 12 dip switches are "off". Then press and hold button 1 and
flick dip switch 12 "on" and then "off". This is confirmed by the LED's being on for 10 seconds. You can
release the remotes button 1.
- To broadcast the receivers code make sure all 12 dip switches are "off" and then flick dip switch 12 "on"
and then "off". This is confirmed by the green LED being on for 10 seconds.
While broadcasting the code press button 1 on a different remote or receiver for 1 second and then release
the button. The LED will flash twice to confirm successful programming.
Broadcasting will be latched on for 10 seconds or stop if any dipswitch is turned on.
Deleting Receivers Memory
Short the CC pin on the receiver for 10 seconds. This will delete all the remotes from the receivers memory.
Other Elsema Receiver manuals

Elsema
Elsema Gigalink GLR43308 Installation manual

Elsema
Elsema G4000 User manual

Elsema
Elsema GLR2703 User manual

Elsema
Elsema Gigalink GLR2702 User manual

Elsema
Elsema GIGALINK GLR2702240 Series User manual

Elsema
Elsema G-2000 User manual

Elsema
Elsema Gigalink GLR2708 User manual

Elsema
Elsema GLR2701SS User manual

Elsema
Elsema G-2025 User manual