GLR2701SS, GLR2702SS
1 & 2-Channel 27MHz Gigalink™ Receiver with Open Collector Output
Features
• One or two channel outputs
• Open Collector Output
• Available with either a Molex female or terminal block connector.
• Uses Gigalink technology, this involves using a receiver cable to
program the transmitter. Some transmitters and receivers are
programmed through the air. This is very risky since another person
can grab your code.
Applications
• Security, wireless activation/deactivation of domestic or industrial alarms
• Gate operation
• Panic buttons
• Remote Activation of lights
• Simultaneous operation of multiple on/off functions
Description
The GLR2701SS and GLR2702SS use the advanced GIGALINK™ technology to combine the decoding
system and FM receiver to form the new GIGALINK™ Strip receiver. The receiver user has the choice of one
or two channel outputs. The GLR2701SS has a single channel output and GLR2702SS has two channel outputs.
The outputs are solid state using the BC337 transistor with open collector. When the outputs are switched to
ground the receiver receives the correct code from the GIGALINK™ transmitter.
The GLR2701SS and GLR2702SS are available with either a terminal block or the Molex female connector.
The terminal block is used for connecting your external wires such as the supply and the antenna, using the
screw type connection.
The six-way female connector is used to integrate a 27MHz receiver onto a printed circuit board. The six-way
male connector is soldered onto the printed circuit board, requiring the 27 MHz receiver. The male connector is
available from Elsema as a Nylon 6-way male low profile connector, part number 6WLP or high profile
connector part number 6WHP. See design dimensions page for more details.
Code Programming
For code programming, please refer to the separate programming instructions.

ELSEMA
1 & 2Channel 27MHz GIGALINK™ Receiver with open collector outputs, GLR2701SS,GLR2702SS
- 2 -
When programming is completed and the GIGALINK cable is removed from the multi channel receiver-coding
socket, the 2-way dip switch is used to select different output modes. This is described below.
Output Modes
Output on the receiver can function in either momentary or latching mode. By default the mode is set to
momentary. Modes selectable from the 2-way dipswitch. Dipswitch 1 corresponds to channel 1 output and
dipswitch 2 corresponds to channel 2 output.
Factory Default = Momentary
Momentary - Output is active for as long as the transmitter button is pressed.
This is a standard mode on most automatic gates or garage door openers.
Latching - Output remains active until next press of the transmitter button.
Similar to switching "on" and "off" a light.
Security
Latching
-
Output remains active until power to the receiver is removed. Similar to security alarms
and fire alarms. To activate the security latching mode, a link needs to be soldered into the
hole marked as latching.
Customised Software
Custom output modes can be programmed to do special functions. Call Elsema for more details.
Products in the Range
GLR2701
1-Channel
GLR2701240
1-Channel, 240V
GLR2702
2-Channel
GLR2702240
2-Channel, 240V
GLR2703
3-Channel Receiver
GLR2704
4-Channel
Receiver
GLR2708
8-Channel
GLR2708R
8-Channel with
Relay Output
GLR2701SS
GLR2702SS
1,2 -Channel, Open
Collector Output
GLR2701SST
GLR2702SST
1,2 -Channel, Open
Collector Output

ELSEMA
1 & 2Channel 27MHz GIGALINK™ Receiver with open collector outputs, GLR2701SS,GLR2702SS
- 3 -
Technical Data
Supply Voltage
7.5-28 VDC. Supply lines should be less than 3m long to comply with radio
frequency authorities
Current Consumption
7 mA on standby at 12 VDC supply
Receiving Frequency
27.195MHz
Operating Temperature
Range
-5 to 50°C
Sensitivity
1uV (for output to activate)
Decoding System
Microcontroller (32-bit word 4.29 x 10^9 codes)
Code Combinations
4,294,967,296
Outputs
GLR2701SS: 1 Open Collector Transistor Output
GLR2702SS: 2 Open Collector Transistor Outputs
Output Transistor
Max switching 100mA/40VDC
Connections
GLR2701SS & GLR2702SS: Female connector , the male connector can be
soldered to a printed circuit board (Available from Elsema).
GLR2701SST & GLR2702SST: Five way screw type terminal block
Dimensions
88 x 43 x 15mm
Mounting Hole Size
3.97 mm or 5/32"
Mounting Hole Spacing
Length 81.28 mm (3.2"), Width 35.56 mm (1.4")
Weight
GLR2701SS: 43g
GLR2702SS: 45g
Useable Transmitters
All Elsema Type 27MHz GLT-... series
Useable Operating Range
Up to 350m with proper 50 ohms, 27MHz CB-Antenna. Up to 200m with 1m
long antenna wire. Antenna wire should be extended and away from metal.
Ranges assume line-of-sight operation.

ELSEMA
1 & 2Channel 27MHz GIGALINK™ Receiver with open collector outputs, GLR2701SS,GLR2702SS
- 4 -
Dimensions
The dimensions below show the position the male connector and plastic mounting studs should be when
designing the GLR43301SS and GLR43302SS receiver onto a printed circuit board.
Block Diagram
Note A
GLR2701SS has 1-way DIP switch
GLR2702SS has 2-way DIP switch
Note B
Available with Molex female connector for PCB
mounting or 5-way Screw Type terminal block

ELSEMA
1 & 2Channel 27MHz GIGALINK™ Receiver with open collector outputs, GLR2701SS,GLR2702SS
- 5 -

ELSEMA
1 & 2Channel 27MHz GIGALINK™ Receiver with open collector outputs, GLR2701SS,GLR2702SS
- 6 -
REGULATORY COMPLIANCE STATEMENTS
American Users
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
FCC Notice
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This device generates, uses, and can radiate radio frequency energy and, if installed and
used in accordance with the instruction, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this device does cause
harmful interference to radio or television reception, the user is encouraged to try to correct the interference by
one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the computer and receiver.
•Connect the computer into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void the
user’s authority to operate the equipment.
Canadian Users
This Class [B] digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe [B] respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
Australian and New Zealand Users
This device has been tested and found to comply with the limits for a Class [B] digital device, pursuant to the
Australian/New Zealand Electromagnetic compatibility (EMC) standard AS/NZS 61000.6.3 set out by the
Spectrum Management Agency.
This manual suits for next models
1
Table of contents
Other Elsema Receiver manuals

Elsema
Elsema G4000 User manual

Elsema
Elsema G-2000 User manual

Elsema
Elsema Gigalink GLR2702 User manual

Elsema
Elsema Gigalink GLR2708 User manual

Elsema
Elsema Gigalink GLR43308 Installation manual

Elsema
Elsema GIGALINK GLR2702240 Series User manual

Elsema
Elsema PentaTimer PCR43302240T User manual

Elsema
Elsema GLR2703 User manual

Elsema
Elsema G-2025 User manual