For detailed information visit www.elsema.com2
All installations and testing must be done only after reading
and understanding all instructions carefully. All wirings should
be done only by trained technical personnel. Failing to follow
instructions and the safety warnings may result in serious
injury and/or damage to property.
Elsema Pty Ltd shall not be liable for any injury, damage,
cost, expense or any claim whatsoever to any person or
property which may result from improper use or installation
of this product.
Risk in the goods purchased shall unless otherwise agreed
in written pass to the buyer upon delivery of the goods.
Any figures or estimates given for performance of goods
are based upon the company’s experience and is what the
company obtains on tests. The company will not accept
liability for failure to comply with the figures or estimates due
to the nature of variable conditions affecting for example Radio
Remote Controls.
Please keep this setup instruction for future reference.
NOTES
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
______________________________________________________________

3Enter the World of Wireless
DESCRIPTION
TECHNICAL DATA
Supply Voltage 11.0 - 28 VDC, 10.0 - 28 VAC. Can use Elsema DC or AC power supply, 12PP1000
or 24PP.
Frequencies for GLR43308
Frequency for GLR2708
433.920 (Standard), 433.664, 433.408, 433.152MHz
27.195MHz
Output Eight open collector outputs.
Antenna ANT433 series (433MHz Series) or ANT27 series (27MHz Series)
Compatible Transmitters GLT433 MHz series, GLT27 MHz series
This Gigalink™ receiver gives you eight open collector outputs switching to ground with a capacity of 125mA 40
VDC each. Each open collector output is protected with a diode to stop any EMF from getting to the receiver.
The receiver’s micro-controller can store unlimited number of transmitters with a high security level using the
encrypted 32-bit digital code. Included with the receiver is the Gigalink™ programming cable.
FEATURES
›Eight channel receiver with 8 open collector outputs
›Supply voltage can be AC or DC
›Low current consumption
›Over 4 billion code combinations
›Crystal controlled for high reliability
›Can store unlimited number of transmitters
›Uses micro-controller technology that can be re-programmed to suit unique applications
›Momentary, latching and security latching modes are all user selectable
›Optional QM100 bracket available for easy mounting to cases or walls
›E version receiver available with a weatherproof case
GLR43308 and GLR2708
Setup and programming instructions for the 8 channel Gigalink™ receiver

For detailed information visit www.elsema.com4
The transmitter and receiver can be multi or single channel programmed.
Multi-channel Programming
This is used to program all channels from a multi-channel receiver to a multi-channel transmitter. Multi-
channel programming can be achieved by following the steps below:
Step 1: Connect power to the GIGALINK™ receiver. Make sure all switches on the mode
dipswitch are off.
Step 2: Momentarily short the two CC pins on the receiver board. This sets all the channels
to a random code. If there are transmitters previously programmed, they will have to
be re-programmed when CC pins are shorted. Do not do this step if you want to
keep previously programmed transmitters.
Step 3: Connect the multi-channel transmitter to the multi-channel receiver by inserting the
GIGALINK™ cable into the transmitters and receivers 2.5-mm Coding socket. (This
will activate the programming mode and is indicated by the red light (LED), on the
transmitter that must remain “on”).
Step 4: Activate any two channels simultaneously on the multi-channel transmitter for
one second, LED should blink twice to confirm code programming and then switch
“off”.
Step 5: Disconnect GIGALINK™ cable.
Repeat steps 3 to 5 to program another multi-channel transmitter.
If you are programming another transmitter, do not short out the CC pins. Shorting out the CC pins
will delete all previously programmed transmitters.
PROGRAMMING INSTRUCTIONS

5Enter the World of Wireless
This is used for programming one channel at a time to the transmitter. Single channel programming can
be achieved by following the steps below:
Step 1: Connect power to the GIGALINK™ receiver. Make sure all switches on the mode
dipswitch are off.
Step 2: Momentarily short the two CC pins on the receiver board. This sets all the channels to
a random code. If there are transmitters previously programmed, they will have to be
re-programmed when CC pins are shorted.
Step 3: Select the receiver channel, to be programmed, by setting the 4-way dipswitch. See
dipswitch table below.
Dipswitch Setting Receiver Channel
123
Off Off Off 1
On Off Off 2
Off On Off 3
On On Off 4
Off Off On 5
On Off On 6
Off On On 7
On On On 8
Step 4: Connect the transmitter to the receiver by inserting the GIGALINK™ cable into the
transmitters and receivers 2.5-mm Coding socket. (This will activate the programming
mode and is indicated by the red light (LED) on the transmitter that must remain “on”).
Step 5: Activate one of the selected channels on the transmitter for approximately one
second, LED should blink twice to confirm code programming and then switch “off”.
Step 6: Disconnect GIGALINK™ cable.
Repeat steps 3 to 6 to program another transmitter channel.
If you are programming another transmitter, do not short out the CC pins. Shorting out the CC pins
will delete all previously programmed transmitters.
SINGLE CHANNEL PROGRAMMING

For detailed information visit www.elsema.com6
Forward Programming
GIGALINK™ receivers have an additional programming feature, known as forward programming.
This feature allows the user to program the transmitter code into the receivers. This will enable the
transmitters to activate unlimited number of receivers simultaneously.
Step 1: Connect power to the receiver and transmitter.
Step 2: Place a jumper across the CC pins of the receiver.
Step 3: Connect the transmitter and receiver using the coding cable.
Step 4: Press the transmitter button for 2 seconds.
Step 5: Remove the coding cable.
Step 6: Remove the jumper from the CC pin.
The receiver is now programmed with the transmitter’s code. Repeat the above steps to program
another receiver.
SPECIAL PROGRAMMING FEATURE FOR GIGALINK™
ACCESSORIES AVAILABLE
Weatherproof Case
for receiver unit
Gigalink™ Coding Cable
For coding Gigalink
transmitters to receivers
SUPREG12, SUPREG24
Supply and Battery charger. Ideal
for charging backup battery and
supplying the receiver.
Suitable Antennas
ANT27 series (27MHz Series) or
ANT433 series (433MHz Series)
Suitable Power packs
12PP-1000, 12V DC 1000mA
24PP, 24V DC 500mA.
QM100
Quick Mount for easy mounting
of receivers on walls.

7Enter the World of Wireless
When the GIGALINK™ cable is disconnected the 4-way dipswitch functions as a mode selector for the output. User
should set the receiver mode correctly. See below table for different mode setting.
Dipswitch Mode Settings
The output relay will respond in the following manner when receiving the correct signal from a transmitter.
1234
“All Momentary”: Relay on, only while correct signal is received
“All Latching”: Outputs alternate at every correct incoming signal
“Momentary & Latching”: Outputs 1-4 are momentary & 5-8 are latching
“Security Latching on”: Outputs will be on until supply to receiver is momentarily
interrupted
“Momentary & Latching”: Outputs 1-6 are momentary & 7-8 are latching
“Momentary & Latching”: Outputs 1-2 are momentary & 3-8 are latching
“Momentary & Latching”: Outputs 1-3 are momentary & 4-8 are latching
“Security Latching on”: Output 1 is security latching & 2-8 are momentary
* Dipswitch 4 is reserved
MODE SETTING

ELSEMA PTY LTD
31 Tarlington Place
Smithfield NSW 2164 Australia
P 02 9609 4668 F 02 9725 2663
W www.elsema.com
Local Distributor
CUSTOMER SUPPORT
If your transmitter and receiver are still not operating properly, contact Elsema’s support office at:
Phone: +61 (2) 9609 4668
Fax: +61 (2) 9725 2663
or you can visit our web site at www.elsema.com for the latest updates.
BLDF045
TROUBLESHOOTING
This section contains helpful troubleshooting tips and solutions.
Symptom Solution
Receiver not responding to transmitter
after programming.
Try to program the transmitter again, but this time with the battery
connected to the transmitter.
Check if GIGALINK™ cable is inserted correctly.
Transmitter activates wrong channel
on a multi-channel receiver.
Wrong dipswitch setting while programming the receiver. Use the
dipswitch table and program again.
Transmitter has short range. Check receiver antenna connection. If you are using a shielded coax
cable, check that the shield is connected to the negative and the
coaxial core to the antenna terminal.
LED is flashing on the transmitter. Replace battery.
This manual suits for next models
1
Table of contents
Other Elsema Receiver manuals

Elsema
Elsema PentaTimer PCR43302240T User manual

Elsema
Elsema Gigalink GLR2702 User manual

Elsema
Elsema G-2025 User manual

Elsema
Elsema GLR2703 User manual

Elsema
Elsema GIGALINK GLR2702240 Series User manual

Elsema
Elsema GLR2701SS User manual

Elsema
Elsema G4000 User manual

Elsema
Elsema Gigalink GLR2708 User manual

Elsema
Elsema G-2000 User manual