Elumen8 Endura 7HEX12 User manual

Order code: ELUM452
Endura 7HEX12 RGBWAUV
Exterior Fixture
User Manual

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Twoyearsfromdateofpurchase.

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 3
Product overview & technical specications
•7x12Wsix-colourLEDs(RGBWAUV)
•Beamangle:20°
•3,321Lux@2m(fullon)
•3.6kHzrefreshrate
•DMXchannels:1/6/10
or11selectable
•Staticcolour,colourchange,colour
fadeandmaster/slavemodes
•0-100%8or16bitdimming
andvariablestrobe
•Bracketallowsformultipleriggingor
oorstandingapplications
•4buttonbacklitmenuwithLCDdisplay
•PowerCONTRUE1input/output
•IPrated5-PinXLRinput/output
•Convectioncooled
•50mmsnootincluded
Endura 7HEX12 RGBWAUV Exterior Fixture
Specications Endura 7HEX12
Powerconsumption 84W
Powersupply 100~240V,50/60Hz
Fuse T2A250V
IPrating IP65
Dimensions 310x280x195mm
Weight 4.8kg
Ordercodes ELUM452
280mm
310mm
225mm
195mm
0m 1m 2m 3m 4m 5m
23°
23° - Lux
FULL ON
R
G
B
W
A
UV
13300
2600
4280
672
4360
2220
N/A
3321
649
1071
168
1090
554
N/A
1480
288
476
74.7
484
246
N/A
830
162
268
42
273
139
N/A
531
104
171
26.9
174
88.6
N/A
TheEnduraseriesareheavy-duty,rentalreadyIPratedparsmadeforthemostdemandingofapplications.
Withicker-freeoperation,thankstoa3,600Hzrefreshrate,andamultitudeofcolourandoutputoptionsthe
seriesisperfectlysuitedforuseinconcert,TVandoutdoorapplications.ThexturecanbecontrolledviaDMXand
providesavarietyofcolourmacro,change,fadeandstrobefunctionswith4selectabledimmercurves.Thexture
itisalsocapableofmaster/slaveoperationandisaccessibleviaa4buttonbacklitdisplaywithmenulockto
preventunauthorisedsettingchanges.TherobustIP65ratedhousingfeaturesTRUE1and5-pinDMXinputsand
outputstofacilitateaproblem-freeconnection.
IP65

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 4
MODE ENTER
05 06 0403
08
02
07
08
01
Technical specications
01-LCDdisplay
02-Functionbuttons
03-PowerCONTRUE1input
04-PowerCONTRUE1output
05-IPrated5-PinDMXinput
06-IPrated5-PinDMXoutput
07-Hangingbracket
08-Hangingbracketadjustableknob
Fuse:TheEndura7HEX12isttedwithaninternalmains(line)fuse.Thefusemustonlybe
changedbyqualiedpersonnel.Beforeopeningthextureshousingorchangingthefuse,
thexturemustbedisconnectedandisolatedfromthemainssupply.Replacementcartridge
fusesmustbeofthesametypeandrating(20mmGlassT2A250V).Whenclosingthexture
pleaseensurethesealiscorrectlypositionedandfreefromdamagetoensurethextureis
watertightandtopreventwateringress.
Inthebox:1 x xture,
1 x 50mm snoot,
1 x PowerCON TRUE1 cable
& 1 x user manual

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 5
Operating instructions
Main Menu Sub Menu Options/Values (Default Settings in BOLD) Description
DMXAddr 001-512 DMXAddressSetting
DMXMode
01CH(01channelmode)
06CH(06channelmode)
10CH(10channelmode)
11CH(11channelmode)
DMXChannelSetting
SlaveMode SlaveMode
DimMode LED
HALOGEN DimmingCurvesModeSetting
DimCurve
Linear
Square
I-Square
S-Curve
DimmingCurvesSetting
01.STATIC
01.STATIC
CL
R(Red)
G(Green)
B(Blue)
W(White)
A(Amber)
U(UV)
RG(Yellow)
GB(Cyan)
RB(Magenta)
RA(FlameRed)
RBU(HotPink)
GBU(PeacockBlue)
BU(CongoBlue)
RGBWAUV(Fullon)
BLAC(Blackout)
F000-F255 StaticColourMode
02.FADE SP00-SP99 F000-F255 ColourFadeMode
03.CHANG SP00-SP99 F000-F255 ColourChangeMode
Manual
R:
G:
B:
W:
A:
U:
STR:
Dim:
000-255 ManualDimmingMode
Macros 00-63 ColourMacros
NODMX Hold
Blackout DMXFailSetting
Temp. –––°C
–––°F FixtureTemperature
IMPORTANT! PLEASE NOTE:TheLCDdisplayforthisxturehasalockingfunctionwhichcanbe
enabledviathemenuwhereafter20secondsofinactivityitwilllock.Tounlockthemenupressthe
buttonsinthefollowingsequence“UP”,“DOWN”,“UP”,“DOWN”,“ENTER”.

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 6
Operating instructions
Channel Value Function
1 000-255 Reddimmer(0-100%)
2000-255 Greendimmer(0-100%)
3000-255 Bluedimmer(0-100%)
4 000-255 Whitedimmer(0-100%)
5 000-255 Amberdimmer(0-100%)
6 000-255 UVdimmer(0-100%)
7 000-255 Strobe(slow-fast)
8 000-255 Masterdimmer(0-100%)
9 000-004 Nofunction
005-125 Colourchange(slow-fast)
126-255 Colourfade(slow-fast)
10 000-045 Linear
Halogen
Dimming
Curves
046-075 Square
076-105 InverseSquare
106-135 S-Curve
136-165 Linear
LED
Dimming
Curves
166-195 Square
196-225 InverseSquare
226-255 S-Curve
10 channel mode (8 bit):
Channel Value Function
1 000-255 Reddimmer(0-100%)
2000-255 Greendimmer(0-100%)
3000-255 Bluedimmer(0-100%)
4 000-255 Whitedimmer(0-100%)
5 000-255 Amberdimmer(0-100%)
6 000-255 UVdimmer(0-100%)
7 000-255 Strobe(slow-fast)
8 000-255 Masterdimmer(0-100%)
9 000-255 Dimmerne
10 000-004 Nofunction
005-125 Colourchange(slow-fast)
126-255 Colourfade(slow-fast)
11 000-045 Linear
Halogen
Dimming
Curves
046-075 Square
076-105 InverseSquare
106-135 S-Curve
136-165 Linear
LED
Dimming
Curves
166-195 Square
196-225 InverseSquare
226-255 S-Curve
11 channel mode (16 bit):
Channel Value Function
1 000-127 Colourmacros
128-191 Colourchange(slow-fast)
192-255 Colourfade(slow-fast)
1 channel mode (8 bit):
Channel Value Function
1 000-255 Reddimmer(0-100%)
2000-255 Greendimmer(0-100%)
3000-255 Bluedimmer(0-100%)
4 000-255 Whitedimmer(0-100%)
5 000-255 Amberdimmer(0-100%)
6 000-255 UVdimmer(0-100%)
6 channel mode (8 bit):
Main Menu Sub Menu Options/Values (Default Settings in BOLD) Description
WhiteBal
R:
G:
B:
W:
A:
U:
000-255 WhiteBalanceSetting
AutoLock OFF
ON AutoLockMenuSetting
Op.Time ––– FixtureRunTime DMXFailSetting
DFSE OFF
ON DefaultFactorySettings FixtureTemperature

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 7
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 8
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 9
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 10

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 11

www.prolight.co.uk Endura 7HEX12 RGBWAUV User Manual 12
This manual suits for next models
1
Table of contents
Other Elumen8 Outdoor Light manuals
Popular Outdoor Light manuals by other brands

Life
Life 39.9PL0432N user manual

MaxLite
MaxLite ML7L4USB30 Series operating instructions

Golnoor
Golnoor Homa G22 Installation and Utilization Instructions

Acuity Brands
Acuity Brands Lithonia Lighting TWR1 LED ALO SWW2 PE installation instructions

Kogan
Kogan SMARTERHOME KAB22CWWT2A user guide

lap
lap AFD1019-NB manual

Robus
Robus RVS00450PIR-01 instruction manual

BaltLED
BaltLED CRANELUX LUMINAIRES installation guide

Saxby Lighting
Saxby Lighting Bayswater 40045 instruction manual

Sunnydaze Decor
Sunnydaze Decor INA-870 manual

Quoizel
Quoizel MAE84MBK installation guide

Malibu Boats
Malibu Boats HV401WL Assembling & installation instructions