Elumen8 Endura UV100 COB User manual

Order code: ELUM461
Endura UV100 COB
Exterior Fixture
User Manual

www.prolight.co.uk Endura UV100 COB User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available mains supply voltage is
between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting xture is for professional use only - it is
not designed for or suitable for household use. The
product must be installed by a qualied technician in
accordance with local territory regulations. The safety of
the installation is the responsibility of the installer. The
xture presents risks of severe injury or death due to re
hazards, electric shock and falls.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical
instruments or any device that may concentrate the beam.
• WARRANTY: Two years from date of purchase.

www.prolight.co.uk Endura UV100 COB User Manual 3
Product overview & technical specications
• 1 x 100W UV COB LED
• Beam angle: 84°
• 3.6kHz refresh rate
• DMX channels: 1 or 3 selectable
• RDM (Remote Device Management)
• Manual and master/slave modes
• 0 - 100% 8 or 16 bit dimming and
variable strobe
• Quick release omega clamp included
• Bracket allows for multiple rigging or
oor standing applications
• 4 button backlit menu with LCD display
• PowerCON TRUE1 input/output
• IP rated 5-Pin XLR input/output
• Temperature controlled fan for
whisper quiet operation
• 50mm snoot included
Endura UV100 COB Exterior Fixture
Specications Endura UV100 COB
Power consumption 105W
Power supply 100~240V, 50/60Hz
Fuse T2A 250V
IP rating IP65
Dimensions 310 x 280 x 245mm
Weight 5.2kg
Order codes ELUM461
280mm
310mm
275mm
245mm
The Endura series are heavy-duty, rental ready IP rated pars made for the most demanding of applications.
With icker-free operation, thanks to a 3,600Hz refresh rate, and a multitude of colour and output options the
series is perfectly suited for use in concert, TV and outdoor applications. The xture can be controlled via DMX and
provides a variety of colour macro, change, fade and strobe functions with 4 selectable dimmer curves. The xture
it is also capable of master/slave operation and is accessible via a 4 button backlit display with menu lock to
prevent unauthorised setting changes. The robust IP65 rated housing features TRUE1 and 5-pin DMX inputs and
outputs to facilitate a problem-free connection.
IP65

www.prolight.co.uk Endura UV100 COB User Manual 4
MODE ENTER
05 06 0403
08
02
07
08
01
Technical specications
01 - LCD display
02 - Function buttons
03 - PowerCON TRUE1 input
04 - PowerCON TRUE1 output
05 - IP rated 5-Pin DMX input
06 - IP rated 5-Pin DMX output
07 - Hanging bracket
08 - Hanging bracket adjustable knob
Fuse: The Endura UV100 is tted with an internal mains (line) fuse. The fuse must only be
changed by qualied personnel. Before opening the xtures housing or changing the fuse,
the xture must be disconnected and isolated from the mains supply. Replacement cartridge
fuses must be of the same type and rating (20mm Glass T2A 250V). When closing the xture
please ensure the seal is correctly positioned and free from damage to ensure the xture is
water tight and to prevent water ingress.
In the box: 1 x xture,
1 x 50mm snoot,
1 x PowerCON TRUE1 cable
& 1 x user manual

www.prolight.co.uk Endura UV100 COB User Manual 5
Operating instructions
Main Menu Sub Menu Options/Values (Default Settings in BOLD) Description
DMX Addr 001-512 DMX Address Setting
DMX Mode 01CH (01 channel mode)
03CH (03 channel mode) DMX Channel Setting
Slave Mode Slave Mode
DimMode LED
HALOGEN Dimming Curves Mode Setting
DimCurve
Linear
Square
I-Square
S-Curve
Dimming Curves Setting
Manual UV:
STR: 000-255 Manual Dimming Mode
NO DMX Hold
Blackout DMX Fail Setting
Temp. –––°C
–––°F Fixture Temperature
AutoLock OFF
ON Auto Lock Menu Setting
Op.Time ––– Fixture Run Time
DFSE OFF
ON Default Factory Settings
Channel Value Function
1 000-255 Master dimmer (0-100%)
1 channel mode (8 bit):
Channel Value Function
1 000-255 Master dimmer (0-100%)
2 000-255 Dimmer ne
3 000-255 Strobe (slow-fast)
3 channel mode (16 bit):
IMPORTANT! PLEASE NOTE:The LCD display for this xture has a locking function which can be
enabled via the menu where after 20 seconds ofinactivity it will lock. To unlock the menu press the
buttons in the following sequence “UP”, “DOWN”, “UP”, “DOWN”, “ENTER”.

www.prolight.co.uk Endura UV100 COB User Manual 6
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 511. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the
chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,
see image below.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
Further DMX cables can be
purchased from all good sound
and lighting suppliers or
Pro Light Concepts dealers.
Please quote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk Endura UV100 COB User Manual 7
Notice:
Be sure to follow the diagrams below when making your own cables. Do not connect the cables
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special note:
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
Termination reduces signal transmission
problems and interference. It is always
advisable to connect a DMX terminal,
(resistance 120 Ohm 1/4 W) between pin 2
(DMX-) and pin 3 (DMX+) of the last xture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk Endura UV100 COB User Manual 8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.