EMIX EMMA-120ZS User manual

Mixing Amplifier with Zone Selector
EMMA-120ZS
EMMA-250ZS
EMMA-380ZS
USE R MANU A L
Before operating, please read this manual carefully
FEATURES:
6 MIC inputs, 2 AUX inputs, 1 Record input, 1 Record output
Phantom power supporting different sorts of MIC input
Priority muting for chime and siren
Three levels of priority muting: MIC1
>
>>
>
siren
>
>>
>
chime
5 LED signal level meter
6 zones output with all-call button control
Individual volume control for each input, master volume, bass, and treble control
Speaker outputs 100V, 70V and 4Ω
Power supply AC 220V-240V and DC 24V
Thermal, over load, short circuit protection with siren warning
Professional Public Address System

2
Left blank for memo

3
FRONT PANEL
1. Led Power Indicator 8.Bass Control
2. Power Switch 9. Treble Control
3. Led Level Meter 10. Mic1, 2, 3 Volume Control
4. Chime 11. Mic4 Volume Control
5. Siren 12. Mic5 / Aux1 Volume Control
6. 6 zone Selection Button 13. Mic6 / Aux2 Volume Control
7. All-call Button Control 14. Master Volume Control
NOTE:
When all 5 LED level meters remain light and sound is distorted. In such case,
adjusting each volume control button till LED 4 (+8dB) and LED 5 (+10dB) flash.
REAR PANEL
1. Phantom power switch 9. Fan exhaust window 17. Record input
2. MIC1: XLR/6.3mm Input 10. AUX 1 / MIC5 switch 18. Speaker output COM
3. MIC2: XLR/6.3mm Input 11. MIC5: 6.3mm input 19. Zone output COM
4. MIC3: XLR/6.3mm Input 12. AUX1: Line Input 20. 24V DC fuse
5. MIC4: XLR/6.3mm Input 13. AUX2: Line Input 21. 24V DC supply input
6. Output terminals 14. AUX2 / MIC6 switch 22. AC power cord
7. 6 zone output terminals 15. MIC6: 6.3mm input 23. AC fuse
8. Emergency input terminal 16. Record output or 24. Chime Volume Control
and +24V all call output Amplifier link
2 3
4 5 10 11 13
1 6 8 12
9 14
7
1 3 4 5
10 11 12 13 14 15 16 17 20 21 22
7 8 9
6
2
18 19 23
24

4
Notice 1. +24V DC (ALL CALL) output power is sent to the RELAY of the volume controller
2. “+24V DC
(
((
(
ALL CALL
)
))
)
”output is controlled by the “ALL” button on the front panel.
SYSTEM CONNECTION
Speaker output terminals are on the rear panel. The terminal under the label “COM” is COMMON. The
terminals under the labels “4Ω, 70V, 100V” are Hot. The connection should be COM-4Ω/ COM-70V /
COM-100V.
Normally the “rated power” (70V / 100V) output terminal is used in output connection. The connected
speaker should have a matching transformer, and the gross power of speakers should be less than the
rated power of the amplifier.
“Rated Impedance”(4Ω) output terminal can be used when speakers are fixed closely, and the gross
impedance of speakers should be 4Ω.
MIC2
MIC3
MIC1
MIC4
MIC6
(6.3mm Socket)
MIC5
(6.3mm Socket )
OPEN
DISC
CD PLAYER
OPEN
DISC
CD PLAYER
108.75
TUNE
00:35
TAPE RECORDER
一
一一
一
+
24V
To 6 zones

5
SPEAKER CONNECTION
1. Single zone output
Note:
Never connect two hot terminals (labeled 4Ω, 70V, 100V) together.
Only choose one pair of output terminals for speaker connection. The connection should
be COM-4Ω/ COM-70V / COM-100V.
4
Ω
70V 100V
COM COM COM
SPEAKERS
8
Ω
8
Ω
4
Ω
70V 100V
COM COM COM
MATCHING
TRANS
MATCHING
TRANS
4
Ω
70V 100V
COM COM COM
MATCHING
TRANS
MATCHING
TRANS

6
2
.
..
.
6-zone output
Note: Voltage of each zone output is 100V
OPERATION INSTRUCTION
Tone and volume:
“MASTER VOL”, “BASS”, and “TREBLE” knobs provide volume and tone
control of overall system. MIC1, 2, 3, 4, 5
、
6 have separate volume control. MIC5 and AUX1 or MIC6
and AUX2 have a common volume control knob.
“
CHIME VOL
”
on the rear panel can be adjusted to
control the volume of chime.
(
volume up by turning it clockwise, down by anti clockwise
)
.
MIC:
MIC inputs are balanced with phantom power. Two types of MIC inputs available: 6.3mm
(MIC1,2
、
3
、
4, 5
、
6) and XLR (MIC 1
、
2
、
3
、
4). MIC1-4 are compatible with two input jacks: XLR and
6.3mm. MIC 5 & 6inputs are compatible with AUX 1 & 2 inputs. “MIC5/AUX1” and “MIC6/AUX2” can
be selected through the switches on the back panel. MIC1 has the highest level of priority muting
function and can override all input signals.
Note: To prevent feedback (howling), keep volume level down to minimum before connecting
microphone.
Microphone application:
The microphone is provided with the phantom power supply, and when
the capacitor type microphone is used, please set the phantom mains switch on the back panel to
“ON”.
MATCHING
TRANS
MATCHING
TRANS
SP1 SP2 SP3 SP4 SP5 SP6
COM COM COM
COM COM COM
ZONE1 ZONE6

7
Chime / Siren:
Pressing the “CHIME” / “SIREN” button will activate the chime or siren circuitry.
The LED indicator above the button will be light up simultaneously. Pressing the “SIREN” button again
will stop siren broadcasting and the LED will be turned off.
Levels of priority muting:
MIC1, siren and chime have priority muting functions. MIC1 has the
highest level of priority muting and can override all other input signals. Siren has the second level.
Chime has the third level and can override all input signals except for MIC1 and siren.
REC input / output:
REC input can connect to an external source (CD player, tuner, cassette
player, etc.) The volume of this input is not adjustable. While recording program signal can send to
REC input and at the same time signal send out to recording equipment through REC output. REC
output also can be used for monitoring the other input signals.
PRECAUTION OF INSTALLATION
1. Do not block ventilation holes.
2. Do not use this amplifier if the power cord is frayed or broken.
3. The amplifier should not be placed in any of the areas:
1) Poor ventilation
2) Exposed to sunlight directly
3) High ambient temperature or adjacent to heat-generating equipment;
4) High humidity or heavy dust;
5) Susceptible to vibration.
4. Make sure the plug connected to the socket.
5. For safety, please use electrical grounding.
6. Short-circuit fault happens when short circuit alarm rings during operation, In such case, switch off
the power immediately and check for short circuit before switching on again.
CAUTION
For safety, when “Power switch” is off, please detach the power plug from the power outlet.
The apparatus shall not be exposed to dripping or splashing and objects filled with liquids,
such as vases, shall not be placed on the apparatus.
To reduce the risk of electric shock, do not remove the cover.
No user serviceable parts inside. Refer servicing to qualified service personnel.

8
SPECIFICATIONS:
Model
EMMA-120ZS EMMA-250ZS EMMA-380ZS
Rated Output 120W 250W 380W
Output Regulation
Ratio Less than 3dB from no-load to full load
Speaker Output 4ΩBalanced
,
70V
、
100V
Zone outputs Six 100V zone outputs
REC Output 10k 0dB
MIC1, 2, 3, 4, 5
、
6 : 600Ω, 4.5mV
,
AUX1, 2: 10KΩ, 270mV unbalanced
;
REC IN
:
10KΩ
,
300mV
Inputs
TELE/EMR: 6kΩ775mV, balanced
Frequency
Response Line
:
40Hz -20KHz (±3dB)
;
Microphone
:
80Hz-15KHz (±3dB)
Distortion < 0.5% at 1KHz, 1/3rated power
MIC1, 2, 3, 4, 5, 6: 80dB
S/N Ratio AUX1, 2: 80dB
Bass: ±12dB at 100Hz
Tone Control
Treble: ±12dB at 10KHz
Protection AC fuses, DC fuses, overload, short circuit
,
Temperature
MIC1 overrides other input signals (Attenuation: 0 to -30dB)
SIREN overrides other input signals
(
except MIC1
)(
Attenuation: 0 to -30dB
)
Muting
Function
CHIME overrides other input signals
(
except MIC1,SIREN
)
(Attenuation: 0
to
-30dB)
Power Supply
Requirements AC220-240V/50-60Hz, DC24V
Power
Consumption 160W 330W 450W
Dimensions 430×360×88mm
Gross Weight 13kg 17kg 19.3kg
Net Weight 11.9kg 16kg 18.3kg
Specifications are subject to change without notice
This manual suits for next models
2
Table of contents
Other EMIX Amplifier manuals