• This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring
regulations. It should be installed in accordance with local building regulations and is for domestic use only.
• Beforecommencinginstallationofyourlightttingalwaysswitchoffthemainssupplyandremovetheappropriate
fuse or switch off the appropriate circuit breaker.
• This is a Class I product, and must be Earthed. The terminal blocks are supplied according to requirements of
thetting.
• Run supply wire from a 5-amp electrical supply protected by an RCD using double insulated 3-core cable of type
H05RN-F 1.0mm2 (not supplied) to selected site, ensuring it is adequately protected through the full length of the
cablerun,itmustcomeoutoftheatsurfaceofthewallorstepsinlinewiththeentrytothetting.
• Exceptwhereinstalledinaconduitorductwhichprovidesequivalentprotectionagainstmechanicaldamage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a
protectiveconductor,orbeofinsulatedconcentricconstruction.Buriedcablesshallbemarkedbycablecoversor
asuitablemarkingtape.Buriedconduitsandductsshallbesuitablyidentied.Buriedcables,conduitsandducts
shallbeatasufcientdepthtoavoidbeingdamagedbyanyreasonablyforeseeabledisturbanceoftheground.
• Nevertbulbsofahigherwattagethanthosespeciedonthelabel,asthesemaycauseoverheatinganddamage
thetting.
• This product has special protection against the ingress of water, and is rated IP44.
• Ifanymodicationismadeitwillinvalidatethewarrantyandmayrendertheproductunsafe.
Assembly/ User Instructions
Before you start
Pleasereadtheseinstructionscarefullybeforettingandretainforreference.Checkthepackagingandmakesure
thatyouhavealltherequiredparts.Followeachassemblystepinordertopreventincorrectassembly.Ensurethat
the product is fully assembled as illustrated before use.
The Light pack contains:
Lighttting.
Terminal connection block(s).
Fixing pack.
The following tools may be required:
Selectionofcrossandatheadscrewdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
Care Information
Allow 10 minutes to cool before replacing, adjusting or cleaning.
Innormalcircumstances,stainlesssteelisveryresistanttocorrosion.Itdoeshoweverrequiremaintenanceto
preservethehighqualityappearance.Washtheproductwithwarmsoapywater,removingallsurfacedeposits.
Rinse with clear water and with a soft cloth, wipe dry. In some cases, surface corrosion may arise after installation.
Thisisnormallycausedbytinyironparticlesleftbehindafterthepolishingprocesswhennishing.Washanddryas
detailedabove.Thenwithasoftclothsoakedwithaprotectiveoil,wipeallover.
Howeveriftheproductissubjecttoextremeenvironmentalconditionssuchasmarinelocations,industrialpollution
andacidrainthesemaintenanceproceduresshouldbecarriedoutaroundfourtimesayear.Forseverecorrosion,
non-abrasivecreamcleanersorproprietarystainlesssteelcleanersshouldbeusedtoremovethecorrosion.Wash
anddryasdetailedabove.Thenwithasoftclothsoakedwithaprotectiveoil,wipeallover.