Endress+Hauser Ecograph T Manual

TI115R/09/en
No. 51009568
Technical Information
Ecograph T
Multi Channel Recorder
Display, record, communicate
Applications
The instrument can be used in many processes and
industries:
• Quality and quantity monitoring in the water/
wastewater industry
• Monitoring of processes in power stations
• Food and dairy industry processes
• Displaying and recording critical parameters in
production cycles
• Tank and level monitoring
• Temperature monitoring in metal working
• Cold storage and transportation monitoring
4 Ô
Your benefits
• Economical: electronic recording replaces strip chart
recorder, saves on consumables
• Versatile: up to 6 universal inputs record all measuring
signals
• Clear layout: multi-coloured display, digital, bargraph
and curve display
• Compact: low installation depth, saves space and
money
• Safe: reliable data archiving with internal memory and
separate CompactFlash card (mechanically locked).
No data loss even in event of power failure!
• System-enabled: network integration and remote data
transmission via Ethernet, RS232/RS485 (modem)
and USB
• Available worldwide: integrated Web server function
for remote monitoring e.g. with E+H Fieldgate
Viewer®
• Reliable: inputs are galvanically isolated from the
system
• Complete: ReadWin®2000 PC software package
contained in scope of supply for professional, tamper-
proof data processing
• Flexible: direct access to archived data also with MS®
Excel or in ReadWin®2000 for example

Ecograph T
2Endress+Hauser
Function and system design
Measuring principle Electronic acquisition, display, recording, analysis, remote transmission and archiving of analog and digital
input signals.
Measuring system Multi-channel data recording system with multi-coloured LCD display (120 mm / 4.7" screen size),
galvanically isolated universal inputs (U, I, TC, RTD), digital input, transmitter power supply, limit relay,
communication interfaces (USB, Ethernet, RS232/485), internal Flash memory and CompactFlash card. 100
ms scan rate for all channels. ReadWin®2000 PC software for comprehensive offline device configuration and
data analysis.
Block diagram
This block diagram is only indicative of the functionality.
Input
Analog multi-function input
channel 1-6
Measured variable, measuring range
To IEC 60873-1:
An additional display error of -/+ 1 digit is permitted for every measured value.
Measuring ranges which can be selected per channel:
*.csv
*.dat
E
LCD 4,7”
Display
115/230 V AC
24 V AC/DC
LCD 4,7”
Display
3/6 universal inputs:
-TC
-RTD
-mA
-mV,V
Optional:
- Integration
- Analysis
1 digital I/O:
- Event
- Time
- Counter
- Control function
Recording internal &
Compact Flash
Lockable cover
Display modes:
- Bargraph
- Trend
- Digital
Communication with PC /
Modem / Network:
- USB
- RS232/485
- Ethernet 10 Base T Web-Browser function
4 Relays:
- 1 change-over contact
- 3 normally open contacts
14 limit values
(variable channel mapping)
1x24V,250mA
Transmitter power
supply output
Measured
variable
Measuring range Maximum measured error
of measuring range (oMR)
Input
impedance
Current 0...20 mA
0...5 mA
4...20 mA
Overrange: up to 22 mA
± 0.10 % Load: = 50 Ohm
Voltage > 1 V 0...10 V
0...5 V
± 10 V
± 30 V
± 0.10 % (980 kOhm

Ecograph T
Endress+Hauser 3
Limit values
Limit values for input voltage and current as well as cable open circuit detection/line influence/temperature
compensation
Voltage ≤1 V ± 1 V
± 150 mV
± 0.10 % (2.7 MOhm
Resistance
thermometer
(RTD)
Pt100: -200 to 850 °C (-328 to 1562 °F) (IEC751, JIS1604, GOST)
Pt500: -200 to 850 °C (-328 to 1562 °F) (IEC751, JIS1604)
Pt1000: -200 to 600 °C (-328 to 1112 °F) (IEC751, JIS1604)
4-wire: ± 0.10 % oMR
3-wire: ± (0.10 % oMR + 0.8 K)
2-wire: ± (0.10 % oMR + 1.5 K)
Cu100: -200 to 200 °C (-328 to 392 °F) (GOST)
Cu50: -200 to 200 °C (-328 to 392 °F) (GOST)
Pt50: -200 to 850 °C (-328 to 1562 °F) (GOST)
4-wire: ± 0.20 % oMR
3-wire: ± (0.20 % oMR + 0.8 K)
2-wire: ± (0.20 % oMR + 1.5 K)
Thermocouples
(TC)
Type J (Fe-CuNi): -210 to 999.9 °C (-346 to 1832 °F) (IEC581-1)
Type K (NiCr-Ni): -200 to 1372 °C (-328 to 2501.6 °F) (IEC581-1)
Type T (Cu-CuNi): -270 to 400 °C (-454 to 752 °F) (IEC581-1)
Type N (NiCrSi-NiSi): -270 to 1300 °C (-454 to 2372 °F) (IEC581-1)
Type L (Fe-CuNi): -200 to 900 °C (-328 to 1652 °F) (DIN43710,
GOST)
± 0.10 % oMR from -100 °C (-148 °F)
± 0.10 % oMR from -130 °C (-202 °F)
± 0.10 % oMR from -200 °C (-328 °F)
± 0.10 % oMR from -100 °C (-148 °F)
± 0.10 % oMR from -100 °C (-148 °F)
(2.7 MOhm
Type D (W3Re-W25Re): 0 to 2315 °C (32 to 4199 °F) (ASTME998)
Type C (W5Re-W26Re): 0 to 2315 °C (32 to 4199 °F) (ASTME998)
Type B (Pt30Rh-Pt6Rh): 0 to 1820 °C (32 to 3308 °F) (IEC581-1)
Type S (Pt10Rh-Pt): 0 to 1768 °C (32 to 3214 °F) (IEC581-1)
Type R (Pt13Rh-Pt): -50 to 1768 °C (-58 to 3214 °F) (IEC581-1)
± 0.15 % oMR from 500 °C (932 °F)
± 0.15 % oMR from 500 °C (932 °F)
± 0.15 % oMR from 600 °C (1112 °F)
± 0.15 % oMR from 100 °C (212 °F)
± 0.15 % oMR from 100 °C (212 °F)
(2.7 MOhm
Measured
variable
Measuring range Maximum measured error
of measuring range (oMR)
Input
impedance
Measured
variable
Limit values (steady-state,
without destroying input)
Cable open circuit detection/line influence/temperature
compensation
Current Maximum permitted input voltage: 2.5 V
Maximum permitted input current: 50 mA
4...20 mA range with cable open circuit monitoring to NAMUR NE43.
Activate/deactivate the 4...20 mA loop monitoring as per NAMUR recomendation NE43.
On activation:
≤3.8 mA: Under range (indicate: vvvvvv)
≥20.5 mA: Over range (indicate: ^^^^^^)
≤3.6 mA or ≥21.0 mA: Open Circuit (indicate: - - - -)
Voltage > 1 V Maximum permitted input voltage: 35 V
Voltage ≤1 V Maximum permitted input voltage: 12 V
Resistance
thermometer
(RTD)
Measuring current: ≤1 mA Disengageable cable open circuit detection
Maximum barrier resistance (or line resistance):
Max. 200 Ohm (4-wire)
Max. 40 Ohm (3-wire)
Maximum influence of barrier resistance (or line resistance) for Pt100, Pt500 and
Pt1000: 4-wire: ±0.0002%/Ohm, 3-wire: ±0.002%/Ohm
Maximum influence of barrier resistance (or line resistance) for Pt50, Cu100 and Cu50:
4-wire: ±0.0006%/Ohm, 3-wire: ±0.006%/Ohm
Thermocouples
(TC)
Maximum permitted input voltage: 12 V Disengageable cable open circuit detection from 50 kOhm
Error, internal temperature compensation: ≤2 K

Ecograph T
4Endress+Hauser
Channel isolation
All analog inputs are galvanically isolated from one another. The testing voltage between the channels is 500
V (no safety isolation)
Scan rate
All channels are scanned within 100 ms.
Resolution
For all ranges: ≥18 bit
Integration (option)
It is possible to calculate an intermediate, daily, monthly, yearly or total value (13-digit, 64 bit).
Digital inputs Number
1 digital input
Input level
To IEC 61131-2:
Logical "0" (corresponds to -3 to +5 V), activation with logical "1" (corresponds to +12 to +30 V)
Input frequency
Max. 25 Hz
Pulse length
Min. 20 ms
Input current
Max. 2 mA
Input voltage
Max. 32 V (steady-state, without destroying input)
Selectable functions
Control input, ON/OFF message, pulse counter (13-digit, 64 bit), operating time, message+operating time.
Functions of the control input: start recording, background illumination OFF, operating lock, time
synchronization.
Output
Auxiliary voltage output The auxiliary voltage is provided to activate the digital input (or sensors) with floating contacts and is
galvanically isolated from the system and the inputs (testing voltage 500 V). The ground of the auxiliary voltage
and the ground of the digital input are electrically interconnected.
Output voltage:
Approx. 24 V, max. 28 V
Output current:
Maximum 250 mA, short-circuit proof, not stabilised
Auxiliary voltage output The auxiliary voltage is provided to activate the digital input (or the sensors) with floating contacts and is
galvanically isolated from the system and the inputs (testing voltage 500 V). The ground of the auxiliary voltage
and the ground of the digital input are electrically interconnected.

Ecograph T
Endress+Hauser 5
Output voltage:
Approx. 24 V, max. ≤28 V
Output current:
Maximum 250 mA, short-circuit proof, not stabilized
Relay outputs Alarm relay:
1 Alarm relay with changeover contact
Standard relay:
3 relays with NO contact for limit value messages (can be configured as NC contact).
!Note!
It is not permitted to mix low voltage and safety extra low voltage (do not mix SELV circuits and low voltage).
Response time:
≤1 s
Maximum DC contact load:
50 V / 300 mA (steady-state, without destroying input)
Maximum AC contact load:
230 V / 3 A (steady-state, without destroying input)

Ecograph T
6Endress+Hauser
Power supply / terminal diagram
Electrical connection (wiring
diagram)
-
+
-
+
-
+
b) 1 V
≤
a)>1V
RS 485
RxD/TxD(-)
RL
RxD/TxD(+)
RS 232
2
2
2
2
3
3
3
3
5
5
5
5
1
1
1
1
5
5
13
13
6
6
14
14
9
9
25
25
7
7
max. 250 V/3 A
+
-
a) 0...5 V, 0...10 V, +/- 10 V, +/- 30 V
b) +/- 150 mV, +/- 1 V
L+
N-
PE
115 / 23 0 VAC
50/60Hz
91 91
12V-24VDC
>5 mA
10 k
_
_
++
_
>20 ms
_
x12x11 x13 x14 x15 x16
x12x11 x13 x14 x15 x16
x12x11 x13 x14 x15 x16
x12x11 x13 x14 x15 x16
RTD
I
U
TC
x12x11 x13 x14 x15 x16
x12x11 x13 x14 x15 x16
x12x11 x13 x14 x15 x16
R=
L
0...20 mA, 4...20 mA, 0...5 mA
TypJ,K,T,N,L,D,C,B,S,R
91
10 k
_
+
_
12V-24VDC
24 V AC/DC
50/60Hz
5
6
9
1
x11 x12 x13 x14 x15 x16
+
+
+
U>1V
TC
-
GND
RxD/TxD +
RxD/TxD -
Ethernet
RS232
41
42
31
32
21
22
11
13
12
L+
N-
PE
Rel4 Rel3
Rel2
Rel1
CH 4 CH 5 CH 6
RS485
611
612
613
614
615
616
511
512
513
514
515
516
411
412
413
414
415
416
CH 1 CH 2 CH 3
111
112
113
114
115
116
211
212
213
214
215
216
311
312
313
314
315
316
+
(Volt drop 1 V, Ri50 Ohm)≤≤
Further units
Cable
resistance
Power
Digital in (DI)
To PC: Cable with
9 pol. Sub-D plug
RxD-3 GND-5
TxD-2
To PC: Cable with
25 pol. Sub-D
plug
To modem: Cable with
9 pol. Sub-D socket
To modem: Cable with
25 pol. Sub-D socket
Analog inputs
On connecting channels 4-6 see
terminal connections CH1-3
LED yellow
LED green

Ecograph T
Endress+Hauser 7
Supply voltage Normal voltage power supply board: 115 / 230 VAC
Low voltage power supply board: 24 VAC/DC
Frequency Nominal frequency: 50 / 60 Hz
Cable specification Screw or spring terminal blocks with reverse polarity protection:
Digital I/O wire cross-section, RS485 and analog inputs: max. 1.5 mm2(14 AWG) (spring terminals)
Power wire cross-section: max. 2.5 mm2(13 AWG) (screw terminals)
Relay wire cross-section: max. 2.5 mm2(13 AWG) (spring terminals)
Power consumption 115 / 230 V: max. 30 VA
24 V: max. 24 VA
Connection data interface,
communication
USB port (standard):
Front-mounted USB-B socket (V1.1) for connecting a laptop or computer using a shielded USB cable. The USB
port can be used for program transmission and device configuration (printers or modems cannot be connected
here).
Ethernet interface (option):
Rear-mounted Ethernet interface 10/100BaseT, plug type RJ45, connection via screened cable, allocation of
IP address via setup menu in device. The device can be connected to devices in an office environment with
this interface. For safe spacing distances, observe the office equipment standard IEC 60950-1. Direct
connection to a PC is possible with a "crossover" cable. The device can be used in the network as a "Web
server". Two Ethernet function LEDs on the rear of the device.
Serial RS232/RS485 interface (option):
Rear-mounted RS232 SUB-D9 socket or RS485 interface (terminal connection) for data/program transmission
or as modem connection.
The following baudrates are supported: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Max. line length with screened cable: 2 m (6.6 ft) (RS232), or 1000 m (3281 ft) (RS485)
Both interfaces are galvanically isolated from the system.
The RS232/RS485 interfaces cannot be used simultaneously.
Performance characteristics
Reference operating
conditions
Ambient temperature: 25 °C ± 5 K (77 °F ± 9 °F)
Air humidity: 55 % ± 10 % r.h.
Maximum measured error (See Input)
Temperature drift Cu100, Cu50 and Pt50: max. ± 0.02 %/K (of measuring range)
All other ranges: max. ± 0.01 %/K (of measuring range)
Long-term drift To IEC 61298-2: max. ± 0.01 %/month (of measuring range)

Ecograph T
8Endress+Hauser
Installation conditions
Orientation Position of use as per DIN 16 257, NL 90 ± 30°
Installation instructions Panel cutout and installation / design, dimensions:
Installation depth: approx. 171 mm (6.73") (incl. terminals and fastening clips)
Panel cutout: 138+1 x 138+1 mm (5.43+0.04 x 5.43+0.04")
Panel thickness: 2 to 40 mm (0.08 to 1.58")
Securing to DIN 43 834
!Note!
A distance of min. 15 mm (0.59") between the devices has to be observed if aligning the devices in the Y-
direction (vertically above one another).
The devices can be arranged horizontally beside one another in the X direction without any spacing between
the devices.
Environment
Ambient temperature range 0 to 50 °C (32 to 122 °F)
Storage temperature -20 to +60 °C (-4 to 140 °F)
Relative air humidity 0 to 50 °C (32 to 122 °F), max. 75% without condensation
Climate class As per IEC 60654-1: B1
Degree of protection Front-panel IP 54 (IEC 60529, Cat. 2) NEMA 2
rear-panel IP 20 (IEC 60529, Cat. 2)

Ecograph T
Endress+Hauser 9
Electrical safety IEC 61010-1, protection class I
low voltage: overvoltage category II
Environment < 3000 m (< 9843 ft) above MSL (mean sea level)
Electromagnetic compatibility
(EMC)
Interference immunity:
As per IEC 61326 (industry) and NAMUR NE21:
• ESD (electrostatic discharge): IEC 61000-4-2 severity 3 (6/8 kV)
• HF field (electromagnetic interference fields): IEC 61000-4-3: severity 3 (10 V/m)
• Burst (quick transient disturbance variables): IEC 61000-4-4 severity 3 (1 kV signal, 2 kV mains)
• Surge on power line: IEC 61000-4-5: 2 kV asymmetrical, 1 kV symmetrical
• Surge on signal line: IEC 61000-4-5: 1 kV asymmetrical (with external protection element)
• Conducted HF: IEC 61000-4-6: 150 kHz...80 MHz, 10 V
• Power failure IEC 61000-4-11 (> 20 ms/0%)
• Voltage variation: IEC 61000-4-11 (40% / 0%)
Emission:
To IEC 61326: Class A (operation in industrial environment)
Interference voltage:
Mains line: To CISPR 16-1/-2: Class A
Interference current:
Ethernet line: To EN 50022: Class A
Interference field intensity:
Housing/all connections: to CISPR 16: Class A
Interference voltage suppression:
• Common mode interference voltage suppression: IEC 61298-3: analog inputs 80 dB at 60 V and 50 Hz /
60 Hz
• Push-pull interference voltage suppression: IEC 61298-3: analog inputs 40 dB at 50 Hz / 60 Hz, for
measuring range/10
Mechanical construction
Design, dimensions See Installation conditions
Weight • Panel-mounted instrument: approx. 700 g (1.54 lb)
Materials Front frame / removable media door: plastic (ABS)
Housing: fibre-glass reinforced plastic (PC)
Protective cover in front of display: plastic (PC)
Human interface
Display elements Type:
LC colour graphic display
Size (screen size, measured diagonally):
120 mm (4.7")
Resolution:
76,800 pixels (320 x 240 pixels)

Ecograph T
10 Endress+Hauser
Background illumination:
50,000 h half value time (= half brightness)
Number of colours:
64 colours
Display modes:
Curves/ load curves, curves in separate section, digital display, bargraph display, events list (limit value/power
failure), status display, history display in curve form with display of digital measured values, date and time
Operating elements Keyboard:
Operation and configuration via 7 push buttons on the front side in interactive dialogue mode with the on
screen menu or using PC software. Integrated operating instructions displayed on screen at the push of a
button.
Saving data Memory cycle:
• Selectable memory cycle: 1s / 2s / 3s / 4s / 5s / 10s / 15s / 20s / 30s / 1min / 2min / 3min / 4min /
5min / 10min / 30min / 1h / 6h / 12h
Internal memory:
• Program memory: 2 MB Flash (non-volatile)
• Setup data memory, measured data memory: permanent back-up of setup data and measured data in internal
Flash memory (non-volatile)
• Main memory: 2 MB SRAM
Data buffering and RTC buffering with lithium cell (replace after 10 years)
External memory:
• Cyclic copying of the measured data for archiving on CompactFlash card
(CompactFlash base: type I)
• Supported CF memory cards: 32 MB, 64 MB, 128 MB, 256 MB and 512 MB. Please use genuine CF-cards
from the manufacturer! (see Accessories)
• If no CF memory card is present in the slot, internal data storage of approx. one day is ensured
• A yellow LED beside the CF slot indicates data access. During this process, the CF card must not be removed.
Risk of losing data!
Typical recording lengths:
Prerequisites for following tables:
• No limit value violation/event storage
• Digital input not used
• Signal analysis deactivated
!Note!
Frequent entries in the event list reduce the memory availability!
Internal memory:
Analog inputs Memory cycle
5 min.
Memory cycle
1 min.
Memory cycle
30 s.
Memory cycle
10 s.
Memory cycle
1 s.
1481 days 106 days, 23 h 53 days, 11 h 17 days, 19 h 1 day, 18 h
3240 days, 12 h 50 days, 20 h 25 days, 10 h 8 days, 11 h 20 h
6137 days, 10 h 28 days, 11 h 14 days, 5 h 4 days, 17 h 11 h

Ecograph T
Endress+Hauser 11
CompactFlash 64 MB:
CompactFlash 256 MB:
Calculation of recording duration:
Calculation of recording duration using "memcalc.xls" (can be found on the CD-ROM of the PC software
supplied).
Real time clock (RTC) Switchable summer time/normal time automated system
Power reserve: buffering via lithium battery
Deviation: < 10 min./year
Time synch possible
Remote operation Configuring and archiving the device settings with CompactFlash or with PC software via rear-mounted serial
interface RS232/RS485 (e.g. modem), Ethernet, or front-mounted USB port.
Analog inputs Memory cycle
5 min.
Memory cycle
1 min.
Memory cycle
30 s.
Memory cycle
10 s.
Memory cycle
1 s.
119973 days, 21h 4443 days, 3 h 2221 days, 13 h 740 days, 12 h 74 days, 1 h
39987 days, 8 h 2111 days, 8 h 1055 days, 16 h 351 days, 21 h 35 days, 4 h
65707 days, 9 h 1182 days, 5 h 591 days, 2 h 197 days 19 days, 16 h
Analog inputs Memory cycle
5 min.
Memory cycle
1 min.
Memory cycle
30 s.
Memory cycle
10 s.
Memory cycle
1 s.
182275 days, 2 h 18301 days, 22 h 9150 days, 23 h 3050 days, 7 h 305 days
341139 days, 4 h 8696 days, 21 h 4348 days, 10 h 1449 days, 11 h 144 days, 22 h
623509 days, 12 h 4869 days, 19 h 2434 days, 21 h 811 days, 15 h 81 days, 3 h

Ecograph T
12 Endress+Hauser
Certificates and approvals
CE mark The measuring system meets the legal requirements of the EC directives. The manufacturer confirms successful
testing of the device by affixing the CE mark.
UL listed for Canada and USA The device was examined by Underwriters Laboratories Inc. (UL) in accordance with the standards UL
61010B-1 and CSA C22.2 No. 1010.1-92.
Other standards and guideli-
nes
CSA 1010.1
Safety requirements for electrical equipment for measurement, control, and laboratory use - General require-
ments (pending).
Ordering information
Product structure Basic features:
4.7" LC colour graphic display (320 x 240 pixels)
Analog inputs, 1 digital input, 4 relays
Interactive dialogue operation with 7 push buttons
24 V auxiliary output voltage
USB connection incl. connecting cable
14 limit values, can be freely defined
PC software package
CompactFlash (CF) slot
Input signal
A3 universal (U, I, TC, RTD)
B6 universal (U, I, TC, RTD)
Power supply
1115/230 V AC, 50/60 Hz
224 V AC/DC, 50/60 Hz
Interface
AUSB
BUSB + RS232/485 + Ethernet
Memory medium
1without CF card
2CF card, 64 MB
3CF card, 256 MB
Housing
APanel 144x144 mm (5.67 x 5.67"), IP54, NEMA 2
BPanel 144x144 mm (5.67 x 5.67"), IP54, neutral, NEMA 2
Operation language
AStandard (German, English)
BCentral/western Europe (German, English, French, Spanish, Italian)
CNorthern Europe (German, English, Danish, Swedish)
DEastern Europe (German, English, Polish, Russian, Czech, Slovak)
EAmerica (German, English, French, Spanish, American)
FJapan (German, English, Japanese)
GChina (German, English, Chinese)
Additional option
AStandard
BIntegration + Analysis
KStandard model, North American region
LIntegration + Analysis, North American region
Approval
1Non-hazardous area
RSG30- 1 ⇐Order code

Ecograph T
Endress+Hauser 13
Accessories
Scope of delivery • Device (with terminals, as per your order)
• 4 fastening clips
• USB cable
• Optional CompactFlash CF card
• PC operating and configuration software on CD-ROM
• Delivery note
• Multi-language Brief Operating Instructions as hard copy
• Operating Instructions on CD-ROM
• Lock plate
Anything missing? Then please inform your supplier.
Accessory parts The following accessories are available:
Documentation
Brochure with overview of recording technology (FA014R/09/en)
Operating Instructions Ecograph T (BA194R/09/en)
Brief Operating Instructions Ecograph T (KA199R/09/)
Innovation brochure Ecograph T (IN001R/09/en)
Order code Accessory
50078843 Terminal, pluggable, 3-pole, for power supply
51009211 Terminal, pluggable, 6-pole, for analog input
51009214 Terminal, pluggable, 3-pole, for relay
51009215 Terminal, pluggable, 6-pole, for relay
51009210 Terminal, pluggable, 3-pole, for digital I/O
51007892 CompactFlash (CF) memory card 64 MB
51009640 CompactFlash (CF) memory card 256 MB
RSG30A-S1 RS232 interface cable, 9pol. to PC connection
RSG30A-S2 RS232 interface cable to modem connection
RSG30A-S3 RS232/RS485 adapter set 230 VAC compact housing, without galv. isolation
RSG30A-S5 RS232/485 adapter set 115 VAC compact housing, without galv. isolation
RSG30A-S6 RS232/RS485 adapter set, DIN rail, 230 VAC with galv. isolation and interface cable for PC/
modem
RSG30A-S7 RS232/RS485 adapter set, DIN rail, 115 VAC with galv. isolation and interface cable for PC/
modem
RSG30A-H1 Field housing IP65
320 mm (12.6“)
320 mm (12.6“)
254 mm (10“)

Ecograph T
International Head Quarter
Endress+Hauser
GmbH+Co. KG
Instruments International
Colmarer Str. 6
79576 Weil am Rhein
Deutschland
Tel. +49 76 21 9 75 02
Fax +49 76 21 9 75 34 5
www.endress.com
[email protected]dress.com
TI115R/09/en/02.06
51009568
FM+SGML 6.0 ProMoDo
Other manuals for Ecograph T
2
Table of contents
Other Endress+Hauser Recording Equipment manuals
Popular Recording Equipment manuals by other brands

Pleora Technologies
Pleora Technologies iPORT NTx-Mini-S user guide

National Instruments
National Instruments NI 9467 Getting started

Scosche
Scosche HDSWC1 Application guide

Phonic
Phonic MM1705a user manual

Advanced Bionics
Advanced Bionics Naida CI Q70 user guide

HHB
HHB Portadrive PDR 2000 Operation manual