Englefield TRADE SERIES User manual

-1-
1199135-A02-B 07/09/2012
Sika Sikasil NG (Arctic White)
•To seal the WHITE shower door and returns to the shower tray.
Usage:
• 1 cartridge per shower
Sika Sikasil NG (Translucent)
•To seal the METALLIC shower door and returns to the shower tray.
Usage:
• 1 cartridge per shower
SEALANT REQUIRED TO COMPLETE THIS INSTALLATION:
( not supplied)
IMPORTANT
READ ALL INSTRUCTIONS
CAREFULLY BEFORE
STARTING THE
INSTALLATION
THIS WILL ENSURE YOU
OBTAIN THE BEST
POSSIBLE
RESULTS
TOOLS REQUIRED
• Level
•Tape
•Pencil
•Phillips screwdriver
•Ruler
•Drill
•Caulking gun
NOTE: Tapware not included. Supplied handles may differ from image
INSTALLATION GUIDE
TRADE SERIES
SQUARE CORNER SHOWER

-2-
1199135-A02-B 07/09/2012
Fitting Instructions – DOOR AND RETURN
NOTE: SHOWER TRAY MUST BE INSTALLED AS
DETAILED ON SUPPLIED INSTRUCTIONS

-3-
1199135-A02-B 07/09/2012
Check the distance between the
walls to ensure that the Door and
Return are within the maximum and
minimum enclosure tolerances.
1Shower base MUST be installed
level.
3
Select preferred shower door
opening and Return position.
4
Position Wall Retainer Profiles
against shower walls, resting on
the shower base sill.
Door wall retainer must have the
fixing holes towardstheinside of
shower.
5
DOOR SIDE RETURN SIDE
10 mm
10 mm
These Profiles should be located
10mm from the front edge of shower
base.
Check vertical with spirit level and
mark fixing holes.
ENSURE WALL RETAINER PRO-
FILES ARE PLUMB.
DOOR SIDE
RETURN SIDE
TYPE DOOR ADJUSTMENT (mm)
MIN MAX
900x900
1000x1000
850 892
950 982
TYPE DOOR ADJUSTMENT (mm)
MIN MAX
900x900
1000x1000
854 875
960 981
A
B
It is recommended that the waste
outlet be ‘taped over’ to avoid the
loss of any components during
installation.
2

-4-
1199135-A02-B 07/09/2012
Centralise Door Assembly
between Wall Retainer and
Corner Post.
Position Return Panel between
Wall Retainer and Corner Post
so that the black lines at each corner
are not visible. DO NOT push the
PVC gasket into position at this
stage.
Mark corner of shower base
10mm in from front edges.
6
Fix both wall retainers in place us-
ing the 6 long screws. Make sure
the screws go into studs.
7
IMPORTANT
WHERE USED RAISED MODESTY LINE
PATTERN MUST FACE OUTSIDE OF
SHOWER
Fit 90O Corner Profile to Return
Panel Assembly and push into
position.
9
Move 90O Corner Post and
Return Panel Assembly out to
allow Door Assembly to be fitted.
10
Fit Door Assembly into Wall
Retainer Profile, then re-positon
Corner Profile and Return Panel to
Door Assembly.
11
Re-align 90O Profile to pre-
determined corner position.
12
13a
b
Note: If Screwing into backing
board only, use appropriate wall
anchors in the wall.
CAUTION: BEFORE DRILLING
HOLES, ENSURE THERE ARE NO
ELECTRICAL CABLES OR WATER
PIPES BEHIND WALLS
CAUTION: We recommend fixing the
wall retainers by screwing through
the backing board and into studs.
Other methods may cause warping
and might void warranty.
Insert return panel into wall
retainer so that the black mark
aligns with the edge of the wall
retainer. NB: The markings on the top
& bottom rails should be on the out-
side of the enclosure & the flexible
side of the PVC gasket on the inside.
8
DO NOT push the PVC gasket into
position at this stage.

-5-
1199135-A02-B 07/09/2012
Using spirit level, plumb Door
and Return assembly and
Corner Post. Tape into position as
shown (tape not supplied). Check
Door opens and shuts properly.
Readjust as necessary.
Check that the Door and Return
Panel Assemblies are level with
top of Wall Retainer and 90OCorner
Profiles.
14
Fit top and bottom hinge
caps. (Note bottom cap has
‘wings’).
15
Slide drip edge seal over wing
on bottom hinge cover and trim
off at edge of glass. Repeat between
hinge cover and extrusion fixed to
door glass.
16
Prise drip edge seal off glass
beside door edge extrusion
enough to slip drip seal moulding
underneath. (Note drip seal moulding
and retainer bracket are ‘handed’.)
Push drip seal firmly back onto glass
and pull into contact with door edge
extrusion. Clamp in place using the
bracket and No. 6 screw.
18
Fit handles following
instructions with handle.
19
20
NOTE: This is an important part
of the installation procedure
and your careful attention at this
stage will ensure that you will
obtain the best possible results.
DO NOT PROCEED TO STEP 21 UNTIL
DOOR IS OPERATING CORRECTLY.
IMPORTANT
TEST THE OPENING AND CLOSING
OPERATION OF THE PIVOT DOOR
If door alignment is incorrect, door
will not function properly and further
adjustments are necessary.
Remove tape and re-align until
correct alignment is achieved.
17
Ensure that the end of this seal just
clears the Door Jamb as the door
closes to create the best seal.
Fit the other smallscrew to the top
hole in the door edge extrusion.

-6-
1199135-A02-B 07/09/2012
Drill holes (with 2.5mm drill
bit, DO NOT USE A BIGGER
DRILL BIT) through punched holes at
top and bottom of each Wall Retainer
and Corner Post to secure door and
return. Make sure Door and Return
assemblies do not move during this
operation. Fit screw, screw caps and
remove tape.
Fit long seal to hinge edge of
glass. Flap faces towards glass.
Push down to butt against bottom
seal. Trim to 5mm below top of glass.
23
21 Position Return Panel PVC
gasket by pushing outside leg
into both Wall Retainer and Corner
Post. It should ‘snap’ into place. Now
push the inside leg into place.
22
RETURN WALL RETAINER
DOOR WALL RETAIN-
90OCORNER POST
Inside Shower
Outside Shower
Push outside leg
Push inside leg

-7-
1199135-A02-B 07/09/2012
On metallic finish shower, seal
joint between Corner Post and
Door Jamb.
Seal up to the PVC gasket
joints between Return Panel &
Corner Post and Return Panel & Wall
Retainer.
SEALANT APPLICATION STEPS
PART TWO SEALANT APPLICATION
Ensure all joints are clean and dry
before applying sealant.
(b) Hold the tube at 45Oangle and
push forward as sealant fills the joint.
(c) The surface of the sealant can
be smoothed (before surface dries)
by using a gloved finger dipped in
a small quantity of water with one
drop of washing liquid added.
(d) Excess sealant should be
removed immediately with a damp
cloth.
CAUTION: Avoid contact with skin,
eyes and mouth and avoid breathing
vapour. If in eyes, immediately flush
with water. If irritation persists, seek
medical attention. Keep out of reach
of children.
IMPORTANT
SIKASIL NG SEALANT SHOULD BE AP -
PLIED TO ALL OUTSIDE JOINTS.
DO NOT SEAL FROM INSIDE.
2a. Seal full height the joint
between the Walls and the
Wall Retainers.
b. Seal joint between the Door
Sill, the Return Panel and the
Shower Tray. IMPORTANT
ALLOW 24 HOURS FOR SEALANT AND
ADHESIVE TO CURE BEFORE USING THE
SHOWER.
d.
To a height of 100mm, seal
joints between Door Frame &
Corner Post and Door Frame & Wall
Retainer.
c.
(a) Cut tip of silicone tube nozzle
at 45O angle.
1.
(e) Allow the silicone 24 hours to
cure before using the enclosure.
6mm
45°
For sealant application, follow steps
(a) to (e) detailed below .
e.
INSTALLATION COMPLETE
Table of contents