ENSA-PS1
PASSIVE INFRARED OUTDOOR
MOTION ACTIVATED SWITCH
INSTRUCTION MANUAL
www.ensalife.com
Thanks for choosing the ENSA-PIR1 Passive Infrared Sensor!
This product is an automated motion activated switch. It is based around a high sensitivity
pyroelectric detector, light sensor and control electronics. The switch will turn on when it
detects movement inside the detection area and stay on until a preset time has elapsed. The
sensor will only switch the load on when the measured LUX level is below a set threshold.
For installation only by a qualified Electrician – IP65 RATED FOR OUTDOOR USE
SPECIFICATIONS:
AC Input: 220-240VAC Detection Range: 180°
PowerFrequency:50Hz DetectionDistance:12mmax(<24℃)
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃
Time Delay: Min.10sec±3sec WorkingHumidity:<93%RH
Max.7min±2min Power Consumption: approx 0.5W
RatedLoad:Max.1200W InstallationHeight:1.8-2.5m
300W Detection Moving Speed: 0.6-1.5m/s
FEATURES:
Built in light sensor which can be set to detect between 3 lux (“moon” position) and 2000 lux
(“sun” position).
Time–Delay before load switch off is adjustable between 10 seconds and 7 minutes.
Time delay before switch off is automatically reset when the sensor detects movement, even
if the load is still on. This means that intermittent movement will keep the load on.
LUX sensing is disabled while the load is on – This stops switched lights from triggering the
lux sensor and turning themselves off.
Wide angle PIR Fresnel lens can be tilted to the best position for optimum sensitivity.
INSTALLATION ADVICE:
To ensure the best detection range, mount the sensor in a position where people will walk
across the detection field, rather than toward it
Good sensitivity Poor sensitivity
As the sensor responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
or polished metal.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units or incandescent lights.
Avoid pointing the detector towards objects that may move in the wind, such as curtains or
tall plants.
INSTALLATION:
Ensure all AC power is switched off.
Loosen the bottom screw and remove the mounting base (figure 1).
Pass the power and load wires through the gasket in the bottom of the sensor.
Connect AC power and the load to the terminal block (figure 2).
Using two screws mount the base on a fixed object (figure 3).
Reattach the sensor to the base, tighten the screw and tilt to desired position.
Figure1: Figure2:
Figure 3:
TESTING THE INSTALLATION:
Set the LUX selector to the maximum
“sun” setting; set the TIME selector to
the minimum “-“ setting.
Switch on AC power; during the first 30
seconds the sensor is in warm up mode and its connected load will not turn on. After this
period is complete, if movement is detected by the sensor the load will be switched on.
After the detected movement stops, the load will switch off in approximately 10 seconds.
Turn LUX selector anti-clockwise to the minimum setting (moon). If the ambient light is
more than three lux, the load will not turn back on after the sensed movement has
stopped.
Please note that when testing in daylight, turn the LUX selector to the (SUN) position,
otherwise the sensor will not turn on the load. Also ensure that any lamp connected as a
load is pointed away from, and is mounted no closer than 60cm from the sensor.
TROUBLESHOOTING:
The load does not turn on:
a. Double check all wiring to the sensor and the load.
b. Try bypassing the sensor to ensure that the load is working correctly.
c. Try increasing the “LUX” setting to reject any ambient light.
The motion detection sensitivity is poor:
a. Ensure that the lens is clean with no obstructions between the moving object and
the sensor.
b. Test at a lower ambient temperature – All PIRs have reduced sensitivity at elevated
temperatures.
c. Ensure that the sensor is mounted so that the detected object moves across the
detection field, rather than towards it.
d. Ensure that installation height is between 1.8m and 2.5m
e. Try tilting the sensor to move the detection field toward the moving object.
The sensor does not turn off the load:
a. Ensure that there are no moving objects or thermal drafts in the detection area.
b. Try reducing the “TIME” setting on the detector.
c. Ensure power drawn by the load is less than 1200W (resistive) or 300W (inductive)

Other ENSA Switch manuals

ENSA ENSA-PS1 User manual

ENSA

ENSA ENSA-PS1 User manual

ENSA ENSA-MS2 User manual

ENSA

ENSA ENSA-MS2 User manual

ENSA ENSA-MS6 User manual

ENSA

ENSA ENSA-MS6 User manual

Popular Switch manuals by other brands

ATEN VanCryst VM0404H quick start guide

ATEN

ATEN VanCryst VM0404H quick start guide

Advantech ProView Series user manual

Advantech

Advantech ProView Series user manual

3Com 3800 user guide

3Com

3Com 3800 user guide

elsner elektronik P03i/P04i Technical specifications and installation instructions

elsner elektronik

elsner elektronik P03i/P04i Technical specifications and installation instructions

Idis DirectIP DH-2100PF Series Operation manual

Idis

Idis DirectIP DH-2100PF Series Operation manual

SEIAOTEK ST-M1602PS user manual

SEIAOTEK

SEIAOTEK ST-M1602PS user manual

Market Central SwitchMaster R6000 Series manual

Market Central

Market Central SwitchMaster R6000 Series manual

Keller PA-22 PS operating manual

Keller

Keller PA-22 PS operating manual

IRT DVS?4040 Instruction book

IRT

IRT DVS?4040 Instruction book

LEGRAND 34061 manual

LEGRAND

LEGRAND 34061 manual

TRENDnet TK-214i Specifications

TRENDnet

TRENDnet TK-214i Specifications

Asus GigaX1024i Specification sheet

Asus

Asus GigaX1024i Specification sheet

TESmart HSW0801A10 user manual

TESmart

TESmart HSW0801A10 user manual

NETGEAR GSM712 Specification sheet

NETGEAR

NETGEAR GSM712 Specification sheet

JETWAY JDL108G-4F-M user guide

JETWAY

JETWAY JDL108G-4F-M user guide

Savant Artison Nano Backpack P5 Quick reference guide

Savant

Savant Artison Nano Backpack P5 Quick reference guide

ATESS ATS30 user manual

ATESS

ATESS ATS30 user manual

Lumantek ez-Pro VS10 manual

Lumantek

Lumantek ez-Pro VS10 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.