Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Connect the equipment into and outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undersired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Limited Warranty
Envisacor Guarantees that every wireless door/window sensor is free from physical defects in
material and workmanship under normal usage for one year from the date of purchase. If the
product proves defective during this one-year warranty period, Envisacor will replace it free of
charge. Envisacor does not issue any refunds. This warranty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused
by accident, dropping or abuse in handling, or any negligent usage; (2) units which have been
repaired, taken apart, or modified by an unauthorized personnel; (3) units not used in accordance
with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial
installation costs, removal cost, or reinstallation cost.
HD 2104
V0
1001013
6B1H-21001
-3-
Installation & Operation Manual
HD 2104
Wireless Door/ Window Sensor
Pull out before use
Introduction
Place door sensor & magnet separately on door/window and door/window frame. A
signal will be sent to HS512/HS514 main panel if door/window is open which will be
detected by HD2104. User will be alerted if the door/window is open.
HD2104 is designed for your full protection including Tamper switch, Back switch and
Reed switch. It gives you all angles of protection you can even think of.
Product Specification
*** For indoor use only***
Specification:
Package
Content:
Operating Frequency: 433.92Mhz
Operating Temp.: -20°C~ 60°C (-4°F ~140°F)
Battery: 2 Panasonic CR2032 Lithium
Battery Life: 3 years (under normal usage)
Dimensions (WxHxD): 35.76x57.58x15.20mm
Build-in Detector: Tamper Switch, Back Switch,
Reed Switch
1pc
1pc
1pc
2pcs
1pc
4pcs
1pc
HD 2014 sensor
Bracket for Contact Magnet
Magnet
Adhesive tape for Magnet /
sensor
Spacer
Screws for bracket/ sensor
Installation & Operation manual
Installation & Testing
1. Please remove pull-out tab before using it.
2. Select the location where the HD 2104 is to
be mounted. RF signals can be interrupted
by metal objects, including metal doors or
large mirrors. Ensure that these types of
objects are not in the way as it can interfere
with the proper operation of the HD2104.
3. Place the mounting bracket in the position
where you are determined. Secure the
bracket to the door frame by using the two screws or adhesive tape provided.
1. Screws to hold bracket He
2. Mounting bracket
3. Tab to release door sensor
4. Adhesive tape
4. “Snap” the sensor in place.
5. Align one end of the magnet with the notch on the side of Door Sensor housing.
6. Mount the magnet a maximum of 3/4 inches from the Door Sensor.
7. For magnet, using the screws provided. If necessary use the spacers and adhesive
tape provided.
8. Open and closed the door/window to ensure that there is no interface.
9. Releasing sensor from bracket by remove the front cover, push the cover tab with a
small screwdriver and slide the Door Sensor up. Then unscrew the PCB, and push
out the bracket tab to release the back case.
-1-
1. Screws to magnet
or pacer
2. Adhesive tape
Operation
1. Opening the door/window to separate the magnet from the sensor will send signal to
the controller.
2. Normal operation, the LED will not light.
3. The HD2104 sensor equipped with tamper switch. If the case of sensor is removed,
the door sensor will report a zone tamper to the controller.
4. If door/window sensor is in low battery status, it will report a message to controller,
and LED will flash 4 times. Please change the battery.
Install Battery
Remove the cover by pressing on the end notch to lift top cover. Unscrew the screw
on the PCB, and remove the PCB. Use care when installing the battery and observe
the correct polarity. Use ONLY the CR2032 lithium battery.
1. LED status indicator
2. Tab to release the cover
3. Screw to hold PCB
4. PCB
5. Notch for magnet
alignment
6. Battery
7. Back
-2-

Other Envisacor Tecnologies Accessories manuals

Envisacor Tecnologies SOLO EMS User manual

Envisacor Tecnologies

Envisacor Tecnologies SOLO EMS User manual

Envisacor Tecnologies HP3102 User manual

Envisacor Tecnologies

Envisacor Tecnologies HP3102 User manual

Popular Accessories manuals by other brands

KERN KFE-TM manual

KERN

KERN KFE-TM manual

Busch-Jaeger 0216-101 manual

Busch-Jaeger

Busch-Jaeger 0216-101 manual

Datapath IQS4 user guide

Datapath

Datapath IQS4 user guide

esera EOS 100 user guide

esera

esera EOS 100 user guide

Eurotronic SIROCO quick start guide

Eurotronic

Eurotronic SIROCO quick start guide

Dorner 2100 Series Installation, maintenance and user manual

Dorner

Dorner 2100 Series Installation, maintenance and user manual

Swann WT83 quick start guide

Swann

Swann WT83 quick start guide

IFM OY90 S Series Original operating instructions

IFM

IFM OY90 S Series Original operating instructions

Vaisala Radiosonde RS92-SGP user guide

Vaisala

Vaisala Radiosonde RS92-SGP user guide

Leviton ODS15-GDW instructions

Leviton

Leviton ODS15-GDW instructions

VOLTCRAFT VC 505 operating instructions

VOLTCRAFT

VOLTCRAFT VC 505 operating instructions

SICK deTec4 Core operating instructions

SICK

SICK deTec4 Core operating instructions

Takex MS-12TE instruction manual

Takex

Takex MS-12TE instruction manual

Ridder Newton 100-S installation manual

Ridder

Ridder Newton 100-S installation manual

horiba ISFET 0141 instruction manual

horiba

horiba ISFET 0141 instruction manual

DayStar Filters Magnesium Quark Eyepiece user manual

DayStar Filters

DayStar Filters Magnesium Quark Eyepiece user manual

Hubbell WS Series Installation and operating instructions

Hubbell

Hubbell WS Series Installation and operating instructions

Zte Consumer Cellular WF723 quick start guide

Zte

Zte Consumer Cellular WF723 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.