Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interferene by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Envisacor Guarantees that every wireless PIR sensor is free from physical defects in
material and workmanship under normal usage for one year from the date of purchase. If
the product proves defective during this one-year warrany period, Envisacor will replace it
free of charge. Envisacor does not issue any refunds. This warnnty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to : (1)
damage to units caused by accident, dropping or abuse in handling, or any negligent usage;
(2) units which have been repaired, taken apart, or modified by an unauthorized personnel;
(3) units not used in accordance with instruction; (4) damanges exceeding the cost of the
produt; (5) transit damage, initial installation costs, removal cost, or reinstallation cost.
Installation & Operation Manual
HP3102
Wireless PIR Motion Sensor
HP 3102 V2 1040701 6B1H-31003
-4-
Introduction
Thanks for choosing the Envisacor’s wireless PIR motion sensor of the home security
device. This sensor monitors movement, and send signal when movement is detected
inside the building. System comes with pet mode build inside for optional function.
Product Description and Specification
*** For indoor use only ***
Specification: Package Content:
Frequency Range: 433.92MHz
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 40°C (5°F~104°F)
Battery: Panasonic CR123A * 1PC
1pc
1pc
1pc
1set
HP 3012 sensor
CR123A Lithium Battery
Installation & Operation
Manual
Accessory bag (including 2
jumper header, 2 screws, 1
adhesive tape & 1 bracket)
Installation
1. Release cover tab to open the cover.
2. Before insert the CR123A battery, user shall decide whether this device need to be
activated when “Stay arm”. In normal case, PIR will not activate when user stay at
home while arm the system. However, some area user won’t even entry, so HP3102
will let user to choice whether HP3102 should activated while stay arm.
3. The factory default will be “AwayArm Mode”, if this is not the function you need, you
can change the jumper as the “Stay Arm Mode” or “Pet Mode”. The Pet Mode won’t
be able to detected the pet about 15lb & under, but it will also depend on the actual
size of pet. Please refer to drawing at page 2.
4. Close the cover back to sensor.
5. To HS 512/514 home security controller into learning mode. Press “Program Switch”
on the back of HP3102 to learn device into system.
6. Mounting suggestion:
1) Using either the screws or adhesive tape to mounting the bracket of HP3102
onto the wall or the corner.
2) Slide down & clip HP3102 into the bracket.
3) Please mount HP3102 at 2 meters high from the ground for best performance
purpose. The solid area means the detector’s coverage range.
4) To release HP3102, press the tab of the bracket & slide up HP3102 from the
bracket. Please refer the mounting method as below:
-1- -2-
Operation
1. Walk in front of HP3102, sensor will send the signal to system, and the LED will flash
once.
2. Normal operation, the LED will not light.
3. The HP3102 sensor equipped with tamper switch. If the cover of sensor is removed,
the PIR sensor will report a zone tamper to the controller, and the LED will flash once.
4. If pet in house, user can choice “pet mode”. Please refer to Installation section.
5. If PIR motion sensor is in low battery status, it will report a message to controller, and
LED will flash five times. Please change the battery.
-3-

Other Envisacor Tecnologies Accessories manuals

Envisacor Tecnologies SOLO EMS User manual

Envisacor Tecnologies

Envisacor Tecnologies SOLO EMS User manual

Envisacor Tecnologies HD 2104 User manual

Envisacor Tecnologies

Envisacor Tecnologies HD 2104 User manual

Popular Accessories manuals by other brands

Larson Electronics EXP-MS-N4X-AT-HV instruction manual

Larson Electronics

Larson Electronics EXP-MS-N4X-AT-HV instruction manual

TRENDnet TEG-S24M2F supplementary guide

TRENDnet

TRENDnet TEG-S24M2F supplementary guide

Nortek M360PIRZ Installation & operation manual

Nortek

Nortek M360PIRZ Installation & operation manual

Honeywell Home PROSiXPIR Quick installation guide

Honeywell Home

Honeywell Home PROSiXPIR Quick installation guide

Deponti Pigato User manual & assembly instructions

Deponti

Deponti Pigato User manual & assembly instructions

PCB Piezotronics 137B25 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 137B25 Installation and operating manual

Honeywell Lyric RF6GB installation instructions

Honeywell

Honeywell Lyric RF6GB installation instructions

LEGRAND Wattstopper CU-250 installation instructions

LEGRAND

LEGRAND Wattstopper CU-250 installation instructions

Philips CRP156 brochure

Philips

Philips CRP156 brochure

Omega Engineering PX548 user guide

Omega Engineering

Omega Engineering PX548 user guide

Panasonic MA2YJ50 Specification sheet

Panasonic

Panasonic MA2YJ50 Specification sheet

Wenglor P1NK208 operating instructions

Wenglor

Wenglor P1NK208 operating instructions

Osprey ATMOS AG 65 owner's manual

Osprey

Osprey ATMOS AG 65 owner's manual

Joolz Geo3 Mono instruction manual

Joolz

Joolz Geo3 Mono instruction manual

Optex CVS2 instruction manual

Optex

Optex CVS2 instruction manual

Dinel CLS-23 instruction manual

Dinel

Dinel CLS-23 instruction manual

MK Electric K5025 quick start guide

MK Electric

MK Electric K5025 quick start guide

GP MP05MA instruction manual

GP

GP MP05MA instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.