Equipment Marketers GA025L Owner's manual

Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 70476301ENR6
January 2014
For more information and pricing, contact:
100 Melrose Avenue
Cherry Hill, NJ 08003
Phone 800.223.1376
www.equipmentmarketers.net
info@eqpmark.com

Front Matter
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 3
Front Matter
Installation must conform with local codes or, in the absence of local codes, with:
In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas
Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1,
latest edition, Canadian Electric Code, Part I.
In Australia and New Zealand, installation must comply with the Gas Installations Standard AS/NZS 5601 Part 1: General
Installations.
WARNING
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion
or to prevent property damage, personal injury or death.
W033
WARNING
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
W052
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user
smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the above
safety information must be posted in a prominent location near the tumble dryer for customer use.
IMPORTANT: The installer must fully test the tumble dryer after installation and demonstrate to the owner how to
operate the machine.
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumble dryer before servicing.
• Close gas shut-off valve to gas tumble dryer before servicing.
• Close steam valve to steam tumble dryer before servicing.
• Never start the tumble dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure
that the tumble dryer is properly grounded.
W002R1

Front Matter
4 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
WARNING
• Installation of unit must be performed by a qualified installer.
• Install tumble dryer according to manufacturer’s instructions and local codes.
• DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil type) duct is
installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with
tumble dryer. Refer to section on connecting exhaust system. Flexible venting materials are known to
collapse, be easily crushed, and trap lint. These conditions will obstruct tumble dryer airflow and increase
the risk of fire.
W752R1
The following information applies to the state of Massachusetts, USA.
• This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.
• This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.
• A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.
• This appliance must not be installed in a bedroom or bathroom.

©Published by permission of the copyright owner.
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed
written consent of the publisher.
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 5
Table of Contents
Introduction..........................................................................................8
Model Identification......................................................................................8
Contact Information.....................................................................................10
Safety Information..............................................................................11
Safety Information.......................................................................................11
Important Safety Instructions........................................................................11
Specifications and Dimensions.............................................................13
Specifications and Dimensions.....................................................................13
Cabinet Dimensions – 025, 030, 035 and 055 Series...................................... 17
Cabinet Dimensions – T30 and T45 Series....................................................18
Exhaust Outlet Locations – 025, 030, 035 and 055 Series............................... 20
Exhaust Outlet Locations – T30 and T45 Series.............................................21
Gas Connection Locations – 025, 030, 035 and 055 Series..............................22
Gas Connection Locations – T30 and T45 Series...........................................24
Electrical Connection Locations – 025, 030, 035 and 055 Series......................26
Electrical Connection Locations – T30 and T45 Series...................................27
Steam Connection Locations – 025, 030 and 035 Series..................................29
Steam Connection Locations – T30 Series.....................................................30
Installation..........................................................................................31
Pre-Installation Inspection............................................................................31
Location Requirements................................................................................31
Position and Level the Tumble Dryer........................................................... 32
Fifth Leveling Leg...................................................................................... 33
Fire Suppression System (Optional Equipment)............................................. 33
Check Local Codes and Permits................................................................33
Water Requirements.................................................................................33
Water Connections...................................................................................34
Electrical Requirements............................................................................35
Auxiliary Alarm...................................................................................... 35
To Reverse the Loading Door (025, 030, 035 and 055 Series)......................... 35
Before Placing Tumble Dryer into Service.................................................... 37
Required for CE Models Only..................................................................39
Installing CE Gas Drying Tumble Dryer.......................................................40
General Information.................................................................................40
CE Orifices.............................................................................................40
Properties of CE Gases............................................................................ 43
Changing Gas Configuration.....................................................................44
Specific Conversion Procedures................................................................45

6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
Exhaust Requirements........................................................................ 48
Exhaust Requirements................................................................................. 48
Layout........................................................................................................48
Make-Up Air.............................................................................................. 48
Venting.......................................................................................................48
Individual Venting...................................................................................50
Manifold Venting.................................................................................... 50
Gas Requirements...............................................................................54
Gas Requirements....................................................................................... 54
Gas Supply Pipe Sizing and Looping............................................................56
High Altitude Burner Orifice Sizing............................................................. 58
Electrical Requirements...................................................................... 63
Electrical Requirements...............................................................................63
Wiring Diagram..........................................................................................63
Wiring for Central Pay................................................................................63
Grounding Instructions................................................................................ 64
For CE Models Only............................................................................... 65
Service/Ground Location..........................................................................65
To Connect Electrical Service To The Tumble Dryer..................................... 69
Conversion Instructions............................................................................... 70
Ferrite Ring Installation (025, 030, 035 and 055 Series Only)..........................71
Electrical Specifications...............................................................................72
Steam Requirements........................................................................... 83
Steam Requirements....................................................................................83
Piping Recommendations.............................................................................85
Installing Steam Trap and Making Condensate Return Connections................. 85
Operating Instructions........................................................................86
Operating Instructions..................................................................................86
Emergency Stop Button On CE Models........................................................86
Operating Instructions..................................................................................86
Reversing Operation....................................................................................87
Control Instructions.....................................................................................87
Dual Digital Timer Control...................................................................... 87
Electronic OPL Micro Control..................................................................89
MDC Coin and Card Control....................................................................91
Micro Control..........................................................................................92
LED OPL Control................................................................................... 92
Ignition Control Operation and Troubleshooting for Models Starting
3/11/13.....................................................................................................94
Internal Control Failure............................................................................94
Troubleshooting.......................................................................................94
Proper Electrode Location........................................................................95
Flame Current Measurement.....................................................................95

Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 7
Ignition Control Operation for Non-CE Models Through 3/10/13.....................95
Ignition Control Operation for CE Models Through 3/10/13............................96
System Tests...........................................................................................97
Diagnostic LED (DGN LED)/Error Codes.................................................97
Adjustments........................................................................................99
Adjustments................................................................................................99
Gas Burner Air Shutter................................................................................99
Airflow Switch..........................................................................................100
Loading Door Switch.................................................................................100
Door Strike...............................................................................................100
Maintenance......................................................................................102
Daily........................................................................................................ 102
Monthly....................................................................................................102
Quarterly...................................................................................................103
Bi-Annually.............................................................................................. 103
Annually...................................................................................................103
Fire Suppression System (Optional Equipment) Maintenance Test................. 103
Before You Call for Service...............................................................105
Removing Tumble Dryer from Service.............................................. 106
Disposal of Unit.................................................................................107

Introduction
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 8
Introduction
Model Identification
Information in this manual is applicable to these models:
Gas Steam Electric
25 Pound GA025L
GA025N
GK025N
GT025L
GT025N
GU025L
GU025N
KA025L
KA025N
KK025N
KT025L
KT025N
KU025L
KU025N
LA025L
LA025N
LK025N
LT025L
LT025N
LU025L
LU025N
PA025L
PA025N
PK025N
PT025L
PT025N
PU025L
PU025N
GT025S
GU025S
KT025S
KU025S
LT025S
LU025S
PT025S
PU025S
GT025E
GU025E
KT025E
KU025E
LT025E
LU025E
PT025E
PU025E
30 Pound GA030L
GA030N
GK030N
GT030L
GT030N
GU030L
GU030N
KA030L
KA030N
KK030N
KT030L
KT030N
KU030L
KU030N
LA030L
LA030N
LK030N
LT030L
LT030N
LU030L
LU030N
PA030L
PA030N
PK030N
PT030L
PT030N
PU030L
PU030N
GT030S
GU030S
KT030S
KU030S
LT030S
LU030S
PT030S
PU030S
GT030E
GU030E
KT030E
KU030E
LT030E
LU030E
PT030E
PU030E
T30 GAT30L
GAT30N
GKT30N
GTT30L
GTT30N
GUT30L
GUT30N
KAT30L
KAT30N
KKT30N
KTT30L
KTT30N
KUT30L
KUT30N
LAT30L
LAT30N
LKT30N
LTT30L
LTT30N
LUT30L
LUT30N
PAT30L
PAT30N
PKT30N
PTT30L
PTT30N
PUT30L
PUT30N
GTT30S
GUT30S
KTT30S
KUT30S
LTT30S
LUT30S
PTT30S
PUT30S
GTT30E
GUT30E
KTT30E
KUT30E
LTT30E
LUT30E
PTT30E
PUT30E

Introduction
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 9
Gas Steam Electric
35 Pound GA035L
GA035N
GK035N
GT035L
GT035N
GU035L
GU035N
KA035L
KA035N
KK035N
KT035L
KT035N
KU035L
KU035N
LA035L
LA035N
LK035N
LT035L
LT035N
LU035L
LU035N
PA035L
PA035N
PK035N
PT035L
PT035N
PU035L
PU035N
GT035S
GU035S
KT035S
KU035S
LT035S
LU035S
PT035S
PU035S
GT035E
GU035E
KT035E
KU035E
LT035E
LU035E
PT035E
PU035E
T45 GAT45L
GAT45N
GKT45N
GTT45L
GTT45N
GUT45L
GUT45N
KAT45L
KAT45N
KKT45N
KTT45L
KTT45N
KUT45L
KUT45N
Not Applicable Not Applicable
55 Pound GA055L
GA055N
GK055N
GT055L
GT055N
GU055L
GU055N
KA055L
KA055N
KK055N
KT055L
KT055N
KU055L
KU055N
Not Applicable GT055E
GU055E
KT055E
KU055E
Explanation of digit in 6th position of model number:
E = Electric
L = Liquid Petroleum (L.P.) Gas
N = Natural Gas
S = Steam
Includes models with the following control suffixes:

Introduction
10 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
BB – reversing basic electronic, coin
BC – basic electronic, coin
BG – basic electronic, OPL mode
BK – reversing basic electronic, prep for
central pay
BL – basic electronic, prep for central
pay
BW – reversing basic electronic, prep for
coin
BX – basic electronic, prep for coin
BY – basic electronic, prep for card
BZ – reversing basic electronic, prep for
card
EO – LED OPL
NC – micro, coin
NJ – micro, prep reader
NX – micro, prep for coin
NY – micro, prep for card
OM – OPL micro
QT – dual digital timer
RE – reversing LED OPL
RQ – reversing dual digital timer
Contact Information
If service is required, contact the nearest Factory Authorized
Service Center.
If you are unable to locate an authorized service center or are
unsatisfied with the service performed on your unit, contact the
source from which you purchased your unit.
When calling or writing about your unit, PLEASE GIVE THE
MODEL AND SERIAL NUMBERS. The model and serial
numbers are located on the nameplate. The nameplate will be in
the location shown in Figure 1 .
Date Purchased ______________________________
Model Number ______________________________
Serial Number _______________________________
Please include a copy of your bill of sale and any service
receipts you have.
WARNING
To reduce the risk of serious injury or death, DO
NOT repair or replace any part of the unit or attempt
any servicing unless specifically recommended in
the user-maintenance instructions or in published
user-repair instructions that you understand and
have the skills to carry out.
W329
If replacement parts are required, contact the source from where
you purchased your tumble dryer.
1 Serial Plate
Figure 1

Safety Information
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 11
Safety Information
Safety Information
Precautionary statements (“DANGER,” “WARNING,” and
“CAUTION”), followed by specific instructions, are found
in this manual and on machine decals. These precautions are
intended for the personal safety of the operator, user, servicer,
and those maintaining the machine.
DANGER
Indicates an imminently hazardous situation that,
if not avoided, will cause severe personal injury or
death.
WARNING
Indicates a hazardous situation that, if not avoided,
could cause severe personal injury or death.
CAUTION
Indicates a hazardous situation that, if not avoided,
may cause minor or moderate personal injury or
property damage.
Additional precautionary statements (“IMPORTANT” and
“NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to
inform the reader of specific procedures where minor
machine damage will occur if the procedure is not
followed.
NOTE: The word “NOTE” is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard related.
WARNING
Failure to install, maintain, and/or operate this
machine according to manufacturer’s instructions
may result in conditions which can produce serious
injury, death and/or property damage.
W051R1
NOTE: The WARNING and IMPORTANT instructions
appearing in this manual are not meant to cover all
possible conditions and situations that may occur. It
must be understood that common sense, caution and
carefulness are factors which CANNOT be built into
this tumble dryer. These factors MUST BE supplied by
the person(s) installing, maintaining or operating the
tumble dryer.
Always contact your dealer, distributor, service agent or
the manufacturer on any problems or conditions you do not
understand.
Important Safety Instructions
WARNING
To reduce the risk of fire, electric shock, serious
injury or death to persons when using your tumbler,
follow these basic precautions.
W776
Save These Instructions
• Read all instructions before using the tumble dryer.
• Install the tumble dryer according to the INSTALLATION
instructions. Refer to the EARTHING (grounding)
instructions for the proper earthing (grounding) of the
tumble dryer. All connections for electrical power, earthing
(grounding) and gas supply must comply with local codes
and be made by licensed personnel when required. It is
recommended that the machine be installed by qualified
technicians.
• Do not install or store the tumble dryer where it will be
exposed to water and/or weather. The tumble dryer cannot be
used in a closed room where the air supply is insufficient. If
necessary, ventilation grids must be installed in the doors or
the windows.
• This appliance must not be activated without lint/foam filter.
• When you perceive a gas odor, immediately switch off
the gas supply and ventilate the room. Do not switch on
electrical appliances and do not pull electrical switches.
Do not use matches or lighters. Do not use a phone in the
building. Warn the fitter, and if so desired, the gas company,
as soon as possible.
• To avoid fire and explosion, keep surrounding areas free of
flammable and combustible products. Regularly clean the
dryer drum and exhaust tube should be cleaned periodically
by competent maintenance personnel. Daily remove piled up
dust from filter and inside of filter compartment.
• Do not use or store flammable materials near this appliance.

Safety Information
12 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
• Do not dry articles that have been previously cleaned in,
washed in, soaked in or spotted with gasoline or machine
oils, vegetable or cooking oils, cleaning waxes or chemicals,
dry-cleaning solvents, thinner or other flammable or
explosive substances as they give off vapors that could
ignite, explode or cause fabric to catch on fire by itself.
• Do not spray aerosols in the vicinity of this appliance while it
is in operation.
• Items such as foam rubber (latex foam), shower caps,
waterproof textiles, rubber backed articles and clothes or
pillows filled with foam rubber pads should not be dried in
the tumble dryer. Do not use the appliance to dry materials
with a low melting temperature (PVC, rubber, etc.).
• Do not tumble fiberglass curtains and draperies unless the
label says it can be done. If they are dried, wipe out the
cylinder with a damp cloth to remove particles of fiberglass.
• Do not allow children on or in the tumble dryer. This
appliance is not intended for use by young children or infirm
persons without supervision. Young children should be
supervised to ensure that they do not play with the appliance.
• Do not reach into the tumble dryer if the cylinder is
revolving.
• Use tumble dryer only for its intended purpose, drying
fabrics. Always follow the fabric care instructions supplied
by the textile manufacturer and only use the dryer drum to
dry textiles that have been washed in water. Only insert spin-
dried linen in the dryer.
• Always read and follow manufacturer’s instructions on
packages of laundry and cleaning aids. Heed all warnings
or precautions. To reduce the risk of poisoning or chemical
burns, keep them out of the reach of children at all times
(preferably in a locked cabinet).
• Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
• Remove laundry immediately after tumble dryer stops.
• DO NOT operate the tumble dryer if it is smoking, grinding
or has missing or broken parts or removed guards or panels.
DO NOT tamper with the controls or bypass any safety
devices.
• Tumble dryer will not operate with the loading door open.
DO NOT bypass the door safety switch to permit the tumble
dryer to operate with the door open. The tumble dryer will
stop tumbling when the door is opened. Do not use the
tumble dryer if it does not stop tumbling when the door is
opened or starts tumbling without pressing or turning the
START mechanism. Remove the tumble dryer from use and
call for service.
• Tumble dryer(s) will not operate with lint panel open. DO
NOT bypass lint panel safety switch to permit the tumble
dryer to operate with the lint panel open.
• Do not modify this appliance.
• Always clean the lint filter daily. Keep area around the
exhaust opening and adjacent surrounding area free from the
accumulation of lint, dust and dirt. The interior of the tumble
dryer and the exhaust duct should be cleaned periodically by
qualified service personnel.
• Solvent vapors from dry-cleaning machines create acids
when drawn through the heater of the drying unit. These
acids are corrosive to the tumble dryer as well as the laundry
load being dried. Be sure make-up air is free of solvent
vapors.
• At the end of each working day, close off all main supplies
of gas, steam and current.
• Do not repair or replace any part of the tumble dryer, or
attempt any servicing unless specifically recommended in
the user-maintenance instructions or in published user-repair
instructions that the user understands and has the skills to
carry out. ALWAYS disconnect and lockout the electrical
power to the tumble dryer before servicing. Disconnect
power by shutting off appropriate breaker or fuse.
• Before the tumble dryer is removed from service or
discarded, remove the door to the drying compartment and
the door to the lint compartment.
• Failure to install, maintain, and/or operate this tumble dryer
according to the manufacturer’s instructions may result in
conditions which can produce bodily injury and/or property
damage.
NOTE: The WARNINGS and IMPORTANT SAFETY
INSTRUCTIONS appearing in this manual are not
meant to cover all possible conditions and situations
that may occur. Common sense, caution and care
must be exercised when installing, maintaining, or
operating the tumble dryer.
Always contact your dealer, distributor, service agent or
the manufacturer on any problems or conditions you do not
understand.

Specifications and Dimensions
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 13
Specifications and Dimensions
Specifications and Dimensions
Specifications 025 Series 030 Series 035 Series 055 Series
Noise level measured
during operation at
operator position of
3.3 feet (1 meter) in
front of machine and
5.2 feet (1.6 meters)
from floor
60 dBA 61 dBA 63 dBA 63 dBA
Net Weight
(approximate): Pounds
(kg)
300 (137) 330 (150) 360 (163) 435 (197)
Standard Packaging
Weight: Pounds (kg) 332 (151) 364 (165) 394 (179) 476 (216)
Standard Packaging
Shipping Dimensions:
Inch (mm)
30 x 43 x 69
(762 x 1,092 x 1,753) 30 x 49 x 69
(762 x 1,245 x 1,753) 33 x 49 x 69
(838 x 1,245 x 1,753) 35.5 x 59 x 72
(902 x 1,499 x 1,829)
Slat Crate Packaging
Weight: Pounds (kg) 406 (184) 446 (202) 480 (218) 506 (230)
Slat Crate Shipping
Dimensions: Inch
(mm)
34.5 x 46 x 87.75
(876 x 1,168 x 1,229) 34.5 x 52 x 87.75
(876 x 1,321 x 2,229) 37.5 x 52 x 87.75
(953 x 1,321 x 2,229) 40 x 60 x 87.25
(1,016 x 1,524 x 2,216)
Cylinder Size:
Inch (mm)
26.5 x 24 (673 x 610) 26.5 x 30
(673 x 762) 30 x 30 (762 x 762) 33 x 35 (838 x 889)
Cylinder Capacity (dry
weight):
Pounds (kg)
25 (11.3) 30 (13.6) 35 (15.9) 55 (24.9)
Drive Motor:
Horsepower (kW) 1/4 (0.1865) 1/4 (0.1865) 1/4 (0.1865) Nonreversing 1/2 (0.373)
Reversing 1/4 (0.1865)
Fan Motor:
Horsepower (kW) 1/4 (0.1865) 1/4 (0.1865) 1/4 (0.1865) 1/2 (0.373)

Specifications and Dimensions
14 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
Specifications 025 Series 030 Series 035 Series 055 Series
50
Hertz
Line
430 (203) 430 (203) 550 (260) 600 (283)Maximum
Airflow
per Pocket:
C.F.M.
(l/sec) 60
Hertz 500 (236) 500 (236) 650 (307) 700 (330)
50
Hertz 0.6
(1.5, 0.15) 0.6 (1.5, 0.15) 0.5
(1.3, 0.13) 0.5 (1.3, 0.13)Maximum
Static Back
Pressure:
Inch W.C.
(mbar, kPa) 60
Hertz 0.8
(2.0, 0.2) 0.8 (2.0, 0.2) 0.6
(1.5, 0.15) 0.6 (1.5, 0.15)
Gas Models
Gas Connection 1/2 in. NPT 1/2 in. NPT 1/2 in. NPT 1/2 in. NPT
50
Hertz 64,000
(18.7, 67.5) 73,000
(21.4, 77) 90,000
(26.4, 95) 102,000
(29.9, 107.6)
Gas Burner
Rating:
Btu/hr.
(kW, Mj/hr.) 60
Hertz 64,000
(18.7, 67.5) 73,000
(21.4, 77) 90,000
(26.4, 95) 112,000
(32.8, 118.2)
Electric Models
400/50/3 10 kWHeating
Element
Rating: Standard 12 kW
21 kW 24 kW 27 kW
Steam Models
Steam Connection 3/4 in. NPT 3/4 in. NPT 3/4 in. NPT N/A
Steam Coil Rating
at 100 psig:
Boiler Horsepower
(Btu/hr.)
(recommended
operating pressure
80-100 psig)
3.9 (134,700) 3.9 (134,700) 4.8 (166,000) N/A

Specifications and Dimensions
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 15
Specifications 025 Series 030 Series 035 Series 055 Series
N/A = Not Applicable
NOTE: All machines are shipped with extra nipple to
convert to metric thread (from Standard).
Specifications T30 Series T45 Series
Noise level measured during operation
at operator position of 3.3 feet (1 meter)
in front of machine and 5.2 feet
(1.6 meters) from floor
66 dBA 67 dBA
Net Weight (approximate):
Pounds (kg)
544 (247) 673 (305)
Standard Packaging Weight: Pounds (kg) 582 (264) 718 (326)
Standard Packaging Shipping
Dimensions: Inch (mm) 32.5 x 47 x 81 (826 x 1,194 x 2,057) 35.5 x 54 x 85 (902 x 1,372 x 2,159)
Slat Crate Packaging Weight: Pounds
(kg) 661 (300) 748 (339)
Slat Crate Shipping Dimensions: Inch
(mm) 37 x 50 x 87.75 (940 x 1,270 x 2,229) 40 x 57 x 87.25 (1,016 x 1,448 x 2,216)
Cylinder Size:
Inch (mm)
30 x 26 (762 x 660) 33 x 30 (838 x 762)
Cylinder Capacity (dry weight):
kg (Pounds)
2 x 30 (2 x 13.6) 2 x 45 (2 x 20.5)
Drive Motor**: Horsepower (kW) 1/4 (0.1865) 1/2 (0.373)
Fan Motor**: Horsepower (kW) 1/4 (0.1865) 1/2 (0.373)
50 Hertz 340 (160) 500 (236)Maximum Airflow
per Pocket**:
C.F.M. (l/sec) 60 Hertz 400 (189) 600 (283)

Specifications and Dimensions
16 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
Specifications T30 Series T45 Series
50 Hertz 0.8 (2.0, 0.2) 0.8 (2.0, 0.2)Maximum Static
Back Pressure*:
Inch W.C.
(mbar, kPa) 60 Hertz 0.9 (2.3, 0.23) 0.9 (2.3, 0.23)
Gas Models
Gas Connection 1/2 in. NPT 1/2 in. NPT
50 Hertz 73,000 (21.4, 77) 87,000
(25.5, 91.8)
Gas Burner
Rating**:
Btu/hr.
(kW, Mj/hr.) 60 Hertz 73,000 (21.4, 77) 95,000
(27.8, 100.2)
Electric Models
Heating Element Rating**: 21 kW N/A
Steam Models
Steam Connection 3/4 in. NPT N/A
Steam Coil Rating at 100 psig**:
Boiler Horsepower (Btu/hr.)
(recommended operating pressure
80-100 psig)
3.2 (111,000) N/A
* with both pockets running
** for each pocket
N/A = Not Applicable
NOTE: All machines are shipped with extra nipple to
convert to metric thread (from Standard).

Specifications and Dimensions
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 17
Cabinet Dimensions – 025, 030, 035 and 055 Series
TMB2292N
Models A B C D E F*
025 Series 26.25 in.
(667 mm) 27.5 in.
(669 mm) 23.35 in.
(593 mm) 25.75 in.
(654 mm) 40.875 in.
(1,038 mm) 6.53 in.
(166 mm)
030 Series 26.25 in.
(667 mm) 27.5 in.
(669 mm) 28.35 in.
(720 mm) 31.75 in.
(806 mm) 46.875 in.
(1,191 mm) 6.53 in.
(166 mm)
035 Series 28 in.
(711 mm) 27.5 in.
(669 mm) 28.35 in.
(720 mm) 31.75 in.
(806 mm) 46.875 in.
(1,191 mm) 6.53 in.
(166 mm)
055 Series 31.88 in.
(810 mm) 26.87 in.
(682.5 mm) 33.75 in.
(857.25 mm) 38.25 in.
(971.5 mm) 53.62 in.
(1,365 mm) 6.53 in.
(166 mm)
Models G H* I* J* K L
025 Series 63.875 in.
(1,622 mm) 16.48 in.
(419 mm) 15.41 in.
(391 mm) 1.59 in.
(40 mm) 24.64 in.
(626 mm) 28 in.
(711 mm)
030 Series 63.875 in.
(1,622 mm) 16.48 in.
(419 mm) 15.41 in.
(391 mm) 1.59 in.
(40 mm) 24.64 in.
(626 mm) 28 in.
(711 mm)

Specifications and Dimensions
18 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
Models G H* I* J* K L
035 Series 63.875 in.
(1,622 mm) 16.48 in.
(419 mm) 19.59 in.
(497.5 mm) 1.59 in.
(40 mm) 27.38 in.
(695 mm) 31.5 in.
(800 mm)
055 Series 66.72 in.
(1,694.7 mm) 17.75 in.
(451 mm) 18.65 in.
(474 mm) 1.59 in.
(40 mm) 30.5 in.
(774.7 mm) 34.5 in.
(876 mm)
* Fire suppression system optional - may not be on machine.
NOTE: Facia panels available to increase height of
models to 72.25 inches (1,835 mm) and 76.25 inches
(1,938 mm).
Cabinet Dimensions – T30 and T45 Series
TMB2332N
Models A B C D E
T30 Series 28 in. (711 mm) 49 in. (1,245 mm) 48.25 in.
(1,226 mm) 11.4 in. (290 mm) 10.7 in. (272 mm)

Specifications and Dimensions
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 19
Models A B C D E
T45 Series 31.88 in.
(810 mm) 50.4 in.
(1,280 mm) 49.3 in.
(1,252 mm) 10.3 in. (262 mm) 9.3 in. (236 mm)
Models F G H I J
T30 Series 25.02 in.
(636 mm) 42.76 in.
(1,086 mm) 27.38 in.
(695 mm) 31.5 in. (800 mm) 76.25 in.
(1,937 mm)
T45 Series 29.37 in.
(746 mm) 48.62 in.
(1,235 mm) 30.50 in.
(775 mm) 34.5 in. (876 mm) 81.25 in.
(2,063.75 mm)
NOTE: To meet ADA compliance, install a 4 inch (102
mm) riser on T30 models only.

Specifications and Dimensions
20 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT Part No. 70476301ENR6
Exhaust Outlet Locations – 025, 030, 035 and 055 Series
TMB2132N
Rear Exhaust
Models Diameter A B
025 Series 6 in. (152 mm) 3.875 in. (99 mm) 4.625 in. (117 mm)
030 Series 6 in. (152 mm) 3.875 in. (99 mm) 4.625 in. (117 mm)
035 Series 8 in. (203 mm) 4.875 in. (124 mm) 5.625 in. (143 mm)
055 Series 8 in. (203 mm) 4.808 in. (122 mm) 6.156 in. (156.3 mm)

Specifications and Dimensions
Part No. 70476301ENR6 ©Published by permission of the copyright owner - DO NOT COPY or TRANSMIT 21
Exhaust Outlet Locations – T30 and T45 Series
TMB1969N
Rear Exhaust
Models Diameter A B C
T30 Series Elliptical Fits 8 in.
(203 mm) 36.54 in.
(928 mm) 4.25 in. (108 mm) 62.42 in.
(1,585 mm)
T45 Series Elliptical Fits 10 in. (254 mm) 40.88 in.
(1,038 mm) 4.75 in. (121 mm) 66.00 in.
(1,676 mm)
This manual suits for next models
207
Table of contents