9
Multiple unit installations
Up to four sets of EZ-WF can be located within range of each other
however please ensure a minimum distance of 30cm between units
from different pairs.
During commissioning initially power each pair separately allowing
sufficient time for auto pairing . Check pairing has been achieved (Video
and audio if required) before powering second and subsequent pairs.
NOTE lf multiple systems are setup in the same vicinity and pairing is
lost between one or more TX/RX module pairs, power off the modules
of the pairs that failed, then power on each pair one at a time and allow
it to synchronize before powering on another pair.
Troubleshooting
PROBLEM POSSIBLE SOLUTIO S
o video or audio • Check power and A/V Cable connections.
• Verify that the TX and RX module are powered on.
• Verify that video and audio source signals are
applied to the TX module.
• Verify that the recording/video monitoring
equipment is functioning properly.
Interference • Adjust the orientation of the antennas on the
in video TX and RX modules.
• Move the equipment away from devices that emit
high radiation, such as microwave ovens, wireless
phones, etc.
EZ-WF Manual_Layout 5 28/01/2013 11:22 Page 9