EUCHNER EKS Series User manual

Electronic-Key-System
Manual
Electronic-Key Adapter EKS and EKS FSA
with USB Interface
Order no. 2094485
USB

Manual EKS Electronic-Key Adapter USB
Page 2/34 Subject to technical modifications 2094485-05-07/19
Table of contents
1General notes...............................................................................................................................................4
1.1 Use of the manual..................................................................................................................................4
1.1.1 Explanation of symbols..............................................................................................................4
1.1.2 Abbreviations .............................................................................................................................5
1.2 CE conformity ........................................................................................................................................5
1.3 Approvals...............................................................................................................................................6
1.4 Correct use ............................................................................................................................................6
1.5 Obligations on the operating organization.............................................................................................6
2Safety precautions ......................................................................................................................................7
3Function........................................................................................................................................................8
3.1 Functional description............................................................................................................................8
3.1.1 Common functions of EKS Standard and version EKS FSA.....................................................8
3.1.2 Additional functions of version EKS FSA (only in G01 housing) ...............................................9
4Technical data............................................................................................................................................10
4.1 Dimension drawing of Electronic-Key adapter.....................................................................................10
4.1.1 Design in G01 housing EKS-A-IUX-G01-ST01 with USB interface.........................................10
4.1.2 Design in G01 housing EKS-A-IUXA-G01-ST01/04 (EKS FSA) with USB interface..............10
4.1.3 Design in G30 housing EKS-A-IUX-G30-STBM with USB interface .......................................11
4.2 Technical data......................................................................................................................................12
4.2.1 Technical data for Electronic-Key adapter in G01 housing .....................................................12
4.2.2 Technical data for Electronic-Key adapter in G30 housing .....................................................13
4.3 Connector assignment.........................................................................................................................14
4.3.1 USB interface socket in G01 housing......................................................................................14
4.3.2 Screw terminals of switching contacts LA1/LA2 and LB1/LB2 (EKS FSA only)......................14
4.3.3 USB interface socket in G30 housing......................................................................................14
4.4 DIP switch settings (only in G01 housing)...........................................................................................14
4.5 LED indicator .......................................................................................................................................15
5Mounting.....................................................................................................................................................16
5.1.1 Compact Electronic-Key adapter in G01 housing....................................................................16
5.1.2 Compact Electronic-Key adapter in G30 housing (FHC).........................................................16
6Electrical connection ................................................................................................................................17
6.1 USB connection...................................................................................................................................17
6.2 Connection of the semiconductor switching contacts (only for EKS G01 FSA) ..................................17
7Setup...........................................................................................................................................................18
7.1 Installation of EKS USB drivers ...........................................................................................................18
7.2 Changing the virtual COM port and driver version number under Windows®.....................................22
7.3 Uninstalling the EKS USB drivers under Windows®............................................................................24

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 3/34
8Operating the Electronic-Key System with the aid of the virtual COM port........................................26
8.1 Special features of the USB interface..................................................................................................26
8.2 Communication....................................................................................................................................26
8.3 Basic message structure......................................................................................................................27
8.3.1 Special features of the 3964R data transfer protocol [1] .........................................................27
8.4 Commands for writing and reading an Electronic-Key read/write .......................................................29
8.4.1 Write process...........................................................................................................................30
8.4.2 Read process...........................................................................................................................31
8.5 Command overview.............................................................................................................................32
8.6 Status numbers....................................................................................................................................32
9Exclusion of liability..................................................................................................................................33
10 Service and repair .....................................................................................................................................33
11 Guarantee...................................................................................................................................................33
12 Bibliography...............................................................................................................................................33

Manual EKS Electronic-Key Adapter USB
Page 4/34 Subject to technical modifications 2094485-05-07/19
1 General notes
1.1 Use of the manual
This manual describes the technical features and the function of the EKS USB read/write stations listed below
(also referred to as “devices” for short in the rest of the text). The complete evaluation and interface electronics
for data transmission are accommodated in these units.
Compact Electronic-Key adapter in G01 housing EKS-A-IUX-G01-ST01 (order no. 092750)
with USB interface
Compact Electronic-Key adapter in G01 housing EKS-A-IUXA-G01-ST01/04 (order no. 098513)
with USB interface version FSA (For Safety Applications)
Compact Electronic-Key adapter in G30 housing EKS-A-IUX-G30-STBM (order no. 157195)
with USB interface
1.1.1 Explanation of symbols
The following symbols are used in this manual to identify important instructions and useful information:
Danger!
Identifies an
immediate hazard. If not avoided, the consequence will be fatality or very serious injuries.
Warning!
Identifies a possible hazard. If not
avoided, the consequence may be fatality or very serious injuries.
Caution!
Identifies a possible hazard. If not
avoided, minor injuries or damage may result.
Attention!
Risk of damage to material or machine or degradation of function.
Information!
Important information is provided to the user here.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 5/34
1.1.2 Abbreviations
The following abbreviations are used in this manual:
AC Alternating Current
BCC Block Check Character
CTS Clear To Send
DC Direct Current / Diagnostic Coverage
DIP Dual Inline Package
DLE Data Link Escape (acknowledgment)
E²PROM Electrically Erasable Programmable Read-Only Memory
EKS Electronic-Key-System
EKS FSA Electronic-Key-System For Safety Applications
ETX End of TeXt
FHC Front Hook Compact
FSA For Safety Applications
LED Light Emitting Diode
MTTFd Mean Time To Dangerous Failure
NAK Negative AcKnowledgment
PA PolyAmide
ADTAcknowledgment Delay Time
ROM Read-Only Memory
STX Start of TeXt
USB Universal Serial Bus
CDT Character Delay Time
1.2 CE conformity
The EKS devices with USB interface correspond to the Radio Equipment Directive (RED) 2014/53/EU and the
RoHS Directive 2011/65/EU. The devices comply with the following European standards:
EN 55011 Industrial, scientific and medical equipment – Radio-frequency disturbance
characteristics – Limits and methods of measurement
EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity standard
for industrial environments
EN 50364 Product standard for human exposure to electromagnetic fields from devices operating
in the frequency range 0 Hz to 300 GHz, used in Electronic Article Surveillance (EAS),
Radio Frequency Identification (RFID) and similar applications
EN 300330 V2.1.1 Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz
and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised
Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
EN 50581 Technical documentation for the assessment of electrical and electronic products with
respect to the restriction of hazardous substances

Manual EKS Electronic-Key Adapter USB
Page 6/34 Subject to technical modifications 2094485-05-07/19
1.3 Approvals
The EKS devices with USB interface are certified in accordance with (UL file number E240367).
For use and operation as per the requirements, a power supply with the feature “for use in Class 2
circuits” must be used.
1.4 Correct use
As part of a higher-level overall system, the EKS Electronic-Key adapter is used for access control and
monitoring on PC-based control systems or parts of control systems for machine installations. EKS can be used,
for example, as part of an overall system for checking access rights on the selection of the operating mode.
However, it is not permitted to derive the operating mode directly from the access rights on the Electronic-Key. If
the selection of the operating mode is relevant for safety, this must not be performed by means of the EKS;
instead an additional device must be used to select the operating mode.
Infor
mation!
The Machinery Directive 2006/42/EC provides information on selection of the operating mode. It is
imperative that this information be followed.
When designing machines and using the Electronic-Key adapter, the national and international regulations and
standards specific to the application must be observed, e.g.:
EN 60204, Safety of machinery – Electrical equipment of machines
EN 12100-1, Safety of machinery – Basic concepts, general principles for design – Part 1: Basic
terminology, methodology
EN 62061, Safety of machinery – Functional safety of safety-related electrical, electronic and programmable
electronic control systems
EN ISO 13849-1, Safety of machinery – Safety-related parts of control systems – Part 1: General principles
for design
Modifications to the electronics of the Electronic-Key adapter and any other changes, especially mechanical
modifications and reworking, are not permissible and will result in the loss of the warranty and exclusion of
liability.
The Electronic-Key adapter must be employed and used only in accordance with
this manual and
other documentation referred to in this manual.
The EKS Electronic-Key adapter is not a safety component in the context of the Machinery Directive.
Without additional precautions, the EKS Electronic-Key adapter must not be used to provide a safety function,
particularly if failure or malfunction of the device could endanger the safety or health of people in the operating
area of a machine.
1.5 Obligations on the operating organization
The manufacturer and the organization operating the higher-level overall system, e.g. a machine installation, are
responsible for the observance of national and international safety and accident prevention regulations
applicable in the specific case.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 7/34
2 Safety precautions
Warning!
The EKS Electronic
-Key adapter is not a safety component in the context of the Machinery Directive.
Without additional precautions, the EKS Electronic
-Key adapter must not be used to provide a safety
function, particularly if failure or mal
function of the device could endanger the safety or health of
persons in the operating area of a machine. On this topic, pay particular attention to the sections
Correct use
(see chapter 1.4) and Electrical connection (see chapter 6).
Warning!
Mounting and electrical connection are allo
wed to be performed only by authorized personnel who are
familiar with the applicable regulati
ons on accident prevention and have read and understood this
manual.
Furthermore, mounting and electrical connection of the version EKS
FSA must be performed only by
personnel familiar with handling safety components.
Caution!
Modifications to the ele
ctronics of the Electronic-Key adapter and any other changes, especially
mechanical modifications and reworking, are not permissible and will result in the loss of the warranty.

Manual EKS Electronic-Key Adapter USB
Page 8/34 Subject to technical modifications 2094485-05-07/19
3 Function
3.1 Functional description
3.1.1 Common functions of EKS Standard and version EKS FSA
The EKS is used for access control and monitoring on PC-based control systems or parts of control systems for
machine installations.
Instead of passwords, coded Electronic-Keys are assigned. In this way unauthorized access to control and
visualization systems is prevented to the greatest possible extent.
The EKS uses a non-contact, inductive read/write identification system.
It comprises:
Electronic-Key
Electronic-Key adapter
The user is responsible for organizing the programming of the application, integration into an overall system and
the assignment and use of the freely programmable memory in the Electronic-Key.
Information!
For easier organization and management of your Electronic
-
Keys and the data they contain, EUCHNER
also offers the Elect
ronic-Key-Manager EKM software.
EKS USB devices are read/write systems with electronics for the inductive bidirectional interface to the
transponder and interface electronics.
Due to the non-contact transfer of data, the Electronic-Key adapter is designed with a high degree of protection
suitable for industry from the access side. The Electronic-Key adapter is fastened from the rear side of the panel
in order to exclude unauthorized tampering from the operator side.
The system is connected via the integrated USB interface that is designed as a virtual COM port in Windows®-
based systems. The power supply is also provided via the USB connection.
Setup and system integration can be realized straightforwardly and quickly on the Electronic-Key adapter with
USB interface. Data communication is in accordance with the transfer protocol 3964R.
The current state of the Electronic-Key adapter is displayed using a two-color LED.
The Electronic-Key is inserted into the Electronic-Key adapter in housing G01 and is held securely in place by a
spring clip. With the Front-Hook-Compact (FHC) mini Electronic-Key adapter in housing G30, the Electronic key
is held in front or dropped into place. The power supply for the transponder and the data are transferred
between the Electronic-Key adapter and the Electronic-Key without using any contacts.
Figure: Cut-away illustration of an Electronic-Key
adapter with Electronic-Key in the compact G01
housing
Figure: Illustration of an Electronic-Key adapter with
Electronic-Key in the compact G30 housing
The Electronic-Keys are tag shaped. The complete transponder with memory chip and antenna is integrated
into the Electronic-Key. The transponder does not have a battery.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 9/34
The data carrier in the Electronic-Key is equipped with a combined memory:
116 bytes E2PROM (programmable) plus 8 bytes ROM (serial number)
The programmable memory of 116 bytes is organized in 4-byte blocks. This means a multiple of 4-byte-sized
blocks must always be written.
3.1.2 Additional functions of version EKS FSA (only in G01 housing)
The version EKS FSA has two additional switching contacts (semiconductor relay) (LA1/LA2 and optionally
LB1/LB2) that are switched off as long as there is no Electronic-Key in the Electronic-Key adapter or if it is not
possible to read the Electronic-Key.
The switching contacts are electrically isolated from the device electronics and from each other. Either AC or
DC can be switched.
Each of the switching contacts is operated with diversity by a dedicated processor that opens the contacts on
removal of the Electronic-Key (see figure Block diagram EKS FSA).
Figure: Block diagram EKS FSA
Due to separate evaluation of channel LA and channel LB, the EKS FSA device can be used in conjunction with
a safe evaluation device in safety-related applications. Integrated voltage monitoring switches off the switching
contacts LA and LB if the power supply is outside the permitted tolerance (see chapter 4.2.1).
Information!
The switching contacts
FSA close when the Electronic-Key is in place
, irrespective of the data allocation
in the memory.

Manual EKS Electronic-Key Adapter USB
Page 10/34 Subject to technical modifications 2094485-05-07/19
4 Technical data
4.1 Dimension drawing of Electronic-Key adapter
4.1.1 Design in G01 housing EKS-A-IUX-G01-ST01 with USB interface
For installation in a control panel, you must provide a cut-out measuring 33 mm x 68 mm according to
DIN IEC 61554.
4.1.2 Design in G01 housing EKS-A-IUXA-G01-ST01/04 (EKS FSA)
with USB interface

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 11/34
4.1.3 Design in G30 housing EKS-A-IUX-G30-STBM with USB interface

Manual EKS Electronic-Key Adapter USB
Page 12/34 Subject to technical modifications 2094485-05-07/19
4.2 Technical data
4.2.1 Technical data for Electronic-Key adapter in G01 housing
Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558
-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
Value
Unit
min.
typ.
max.
General parameters
Housing
Plastic (PA 6 GF30 gray)
Degree of protection
IP65/IP67 in installed state
Ambient temperature
0
+ 55
°C
Mounting cut-out acc. to DIN IEC 61554
33 x 68
mm
Power supply via USB
4.5
5
5.5
V
Current consumption
100
mA
Interface, data transfer
Interface to the PC
USB Full Speed (compatible with all USB versions)
Transfer protocol
3964R
Data transfer rate
9.6
kbaud
Data format
1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit
USB interface connection
Type B socket
Cable length
3
m
LED indicator
Green: “Ready” (in operation)
Yellow: “Electronic-Key active” *
Version FSA (For Safety Applications) – parameters for floating semiconductor switching contacts LA and LB
Switching contact connection
Plug-in connection terminal, 4-pin,
with screw terminal (tightening torque 0.22 Nm), conductor
cross-section 0.14 ... 1.5 mm²
Power supply U for load (LA, LB)
24
30
V
Switching current (with overload protection)
1
10
50
mA
Output voltage UA(LA, LB) in switched state
U x 0.9
U
V
Resistance in switched state
35
ohms
Capacitive load
1
µF
Utilization category acc. to AC-12
EN IEC 60947-5-2 AC-15
DC-12
DC-13
50 mA / 24 V
Difference time of the outputs** (LB first)
200
ms
Reliability values acc. to EN ISO 13849-1 (FSA version only)
Category (with downstream safe evaluation)
3
MTTF
d
Evaluation of data channel and one
switching contact LA
416 years
Evaluation of data channel and both
switching contacts LA and LB
803 years
DC
92
%
* The LED illuminates yellow if there is a functional Electronic-Key in the Electronic-Key adapter.
** If the USB interface is accessed during placement or removal of the Electronic-Key,
the difference time can be more than 200 ms.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 13/34
4.2.2 Technical data for Electronic-Key adapter in G30 housing
Value
Unit
min.
typ.
max.
General parameters
Housing
Plastic (PVDF GF30, gray)
Degree of protection
IP65/IP67/IP69K in installed state
Ambient temperature
-20
+70/+100 *
°C
Mounting bore
Ø 22.5
mm
Power supply via USB
4.5
5
5.5
V
Current consumption
100
mA
Interface, data transfer
Interface to the PC
USB Full Speed (compatible with all USB versions)
Transfer protocol
3964R
Data transfer rate
9.6
kbaud
Data format
1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit
USB interface connection
Type Mini-B socket
Cable length
3
m
LED indicator
Green: “Ready” (in operation)
Yellow: “Electronic-Key active” **
* This is not an ambient temperature for operation. It is valid for a time of no more than 3 minutes, e.g. for cleaning
purposes.
** The LED illuminates yellow if there is a functional Electronic-Key in the Electronic-Key adapter.

Manual EKS Electronic-Key Adapter USB
Page 14/34 Subject to technical modifications 2094485-05-07/19
4.3 Connector assignment
4.3.1 USB interface socket in G01 housing
The socket on the Electronic-Key adapter is designed as USB type B.
4.3.2 Screw terminals of switching contacts LA1/LA2 and LB1/LB2 (EKS FSA only)
Information!
The plug
-in connection terminal is included with the Electronic-Key adapter.
Plug-in connection terminal,
2 x 2-pin,
with screw terminal
Pin Channel Function
1 LA NO contact, channel LA
2
3 LB NO contact, channel LB
4
4.3.3 USB interface socket in G30 housing
The socket on the Electronic-Key adapter is designed as USB type Mini-B.
4.4 DIP switch settings (only in G01 housing)
Using the DIP switches S1 to S8, various parameters can be set.
Write protection can be enabled using DIP switch S1. In this way the writing of data to the Electronic-Key
read/write is prevented.
The settings are adopted only when the power supply is switched on.
DIP switches, 8-switch:
1 2 3 4 5 678
ON
DIP
switch
Functions Factory setting
S8
OFF = Electronic-Key read/write ON = Electronic-Key read-only *
OFF
S7
OFF
S6
OFF
S5
OFF
S4
OFF
S3
OFF
S2
OFF
S1
ON = write protection for Electronic-Key read/write
OFF
*
The read-only transponder type can also be read using the Electronic-Key adapter with USB interface. However, we do
not recommend using this transponder type in new installations. The read-only transponder cannot be used in
conjunction with the version EKS FSA.
Information!
It is
imperative that all DIP switches without a function (S2 to S7) are set to OFF! In this way problems
with any functions added in the future will be avoided.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 15/34
4.5 LED indicator
The Electronic-Key adapter operating states are indicated using a two-color LED on the front.
The illumination of the LED in any color indicates the presence of the operating voltage.
Color
Operating state
Description
Green
Ready
Electronic-Key adapter is ready.
Yellow
Electronic-Key active
There is an Electronic-Key in the Electronic-Key adapter and it has been detected.

Manual EKS Electronic-Key Adapter USB
Page 16/34 Subject to technical modifications 2094485-05-07/19
5 Mounting
Warning!
Mounting
must be performed only by authorized personnel.
After mounting, again check the Electronic
-Key adapter for firm seating and correct sealing of the front
panel.
5.1.1 Compact Electronic-Key adapter in G01 housing
Attention!
To achieve the degree of protection
IP65/IP67, it is necessary to install the Electronic-Key adapter in a
clean, flat metal plate at least 2 mm thick and to tighten the screws
with a tightening torque of 0.25 ...
0.35
Nm.
A s
uitable strain relief must be provided for the connecting cables in order to avoid damage to the
connection sockets or malfunctions.
The Electronic-Key adapter is intended for mounting in control panels with a cut-out measuring
33 mm x 68 mm according to DIN IEC 61554 (see chapters 4.1.1 and 4.1.2). The device is fastened using
screw clamp elements from the rear side of the panel.
Information!
The screw clamp elements for front panel mounting are included with the Electronic
-Key adapter.
1. Insert the Electronic-Key adapter, with seal already bonded in place, into the mounting cut-out from the
front.
2. Insert screw clamp elements into the housing of the Electronic-Key adapter from the side up to the stop and
tighten with 0.25 …0.35 Nm.
Attent
ion!
The device may be
damaged if the tightening torque exceeds 0.35 Nm.
5.1.2 Compact Electronic-Key adapter in G30 housing (FHC)
Attention!
To achieve the degree of protection
IP65/IP67/IP69K, it is necessary to install the FHC Electronic-Key
adapter in a clean, flat metal plat
e at least 2 mm thick and to tighten the central fixing nut with a
tightening torque of 2
Nm.
Suitable strain relief must be provided for the connecting cables in order to avoid damage to the
connection sockets or malfunc
tions.
The Electronic-Key adapter is intended for mounting in control panels with a cut-out Ø 22.5 mm (see chapter
4.1.3).

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 17/34
6 Electrical connection
Attention!
If c
onnected incorrectly, the Electronic-Key adapter may be damaged.
Observe electrical characteristics and terminal assignment (see chapter 4)
When installing connections, the operating organization must ensure compliance with the EMC
safety requirements in accordance with EN 55011 and EN 61000-6-2.
Do not lay connecting cables in the immediate vicinity of sources of interference.
6.1 USB connection
The Electronic-Key adapter interface is compatible with all USB versions.
Information!
Only a USB-compatible cable with a maximum length of 3 m is allowed to be used as the
connecting cable.
The Electronic-Key adapter must always be connected to the same USB port to ensure the correct
allocation of the virtual COM port in Windows®-based systems.
If a USB hub is connected in between, or the Electronic-Key adapter must be moved, a new COM
port allocation must be made. This action can be performed only with administrator rights (only for
Windows®).
6.2 Connection of the semiconductor switching contacts (only for EKS
G01 FSA)
Warning!
Incorrect connection or errors in the safety
-related integration of the EKS FSA can lead to fatal injury.
For this reason, observe the following safety aspects:
It is not possible to generate a safe signal by using only the switching contacts LA1/LA2 and
LB1/LB2. Safe, downstream evaluation is always necessary. Use of the switching contact LB1/LB2
is optional.
Safe evaluation must always be dual-channel: evaluation of switching contact LA1/LA2 as channel
LA together with evaluation of the data line as channel LB.
Information!
The switching contac
t LA1/LA2 is used in combination with functionally safe applications. The function
that can be evaluated in terms of safety engineering is the reliable detection that an Electronic
-Key has
not been placed.
Attention!
The power is
supplied via the USB connection. If the power supply drops below 4.5 V or exceeds 5.5 V,
the switching contacts LA1/LA2 and LB1/LB2 will be switched off.

Manual EKS Electronic-Key Adapter USB
Page 18/34 Subject to technical modifications 2094485-05-07/19
7 Setup
Perform setup in the following sequence:
1. Set the DIP switches on the Electronic-Key adapter
(see chapter 4.4 DIP switch setting).
2. Check whether mounting and electrical connection are correct (see chapter 5 Mounting and chapter 6
Electrical connection).
3. After the USB connecting cable is plugged in and the EKS USB drivers are installed, the LED on the front of
the Electronic-Key adapter illuminates green. This indicates that the power supply is present.
4. Place the Electronic-Key in the Electronic-Key adapter. The LED changes to yellow.
5. Important: for the version EKS FSA, all safety functions must also be thoroughly tested.
7.1 Installation of EKS USB drivers
The EKS USB drivers provided are certified by Microsoft (Windows Hardware Quality Labs / WHQL) and
digitally signed. These drivers are therefore distributed via Windows updates and the Microsoft Update Catalog.
Please proceed as follows if the EKS USB drivers do not install themselves automatically:
To begin installation, have the driver software (order no. 094376) at hand in a folder or on a data carrier. The
driver software is available for download on the Internet at www.euchner.com or free of charge on request.
Information!
The user must
be logged on as an administrator in order to install or uninstall the drivers.
If an Internet connection and administrator rights are available when a
read/write station is connected to a Windows PC, the drivers will
automatically install themselves in the background.
You will be notified as soon as automatic installation is complete.

Manual EKS Electronic-Key Adapter USB
2094485-05-07/19 Subject to technical modifications Page 19/34
Connect the EKS read/write station to
an unoccupied USB port on the PC
using the corresponding USB cable.
The device is shown as an unknown
device under Other devices in the
Device Manager.
In File Explorer, select the folder
corresponding to the operating system
architecture.
Run setup.exe.
Click Next.

Manual EKS Electronic-Key Adapter USB
Page 20/34 Subject to technical modifications 2094485-05-07/19
The EKS USB drivers will be installed.
After completing installation, click
Finish.
This manual suits for next models
4
Table of contents
Other EUCHNER Adapter manuals
Popular Adapter manuals by other brands

j5 create
j5 create JUA330 Quick installation guide

Silvercrest
Silvercrest SUHL 2 A1 Operation and safety notes

New Star
New Star Neomounts FPMA-VESAMAC2127 instruction manual

Qlogic
Qlogic BR-815 quick start guide

Sun Power
Sun Power SPS-360P Series User manual and safety information

CoolGear
CoolGear USBG-COM-X product manual