EVA Logik ZW11 User manual

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
ZW11 Z-Wave Mutil-relay Manual
ZW11 Z-Wave Mutil-relay
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS WARNING
Model:ZW11
RISK OF FIRE
Power:DC5V /AC12-24V.
RISK OF ELECTRICAL SHOCK
Signal (Frequency): 908.42 MHZ.
RISK OF BURNS
Maximum load R1/R2 250 V / 15A*2
CONTROLLING APPLIANCES:
R3 250V/20A
EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL
APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT
Range: Up to 100 feet line of sight between the Wireless Controller
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave receiver module.
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES
Operating Temperature Range: 32-104° F (0-40° C)
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Specifications subject to change without notice
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
due to continuing product improvement
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
Website:www.nie-tech.com
DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:
This product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers.
All non-battery operated nodes within the network will
act as repeaters regardless of vendor to increase reliability of the network.
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW11 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
The Device Type of the ZW11 is on/off power switch.
The Role Type of the ZW11 is Always On Slave Role Type
Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Support firmware upgrades via Over-the-air (need Gateways support)
Product Overview:
A. Program Button
B. LED Indicator
C. R1,R2,R3 Relay Out
D. SW1,SW2,SW3 connect switch
E. AC/DC 12-24V Input
F. DC 5V Input TYPE-C
ZW11 Installation Wiring Diagram
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
AB
CD
E
F
Key function description
Function 1:
quickly press 3x: inclusion or exclusion
Function 2:
press and hold for more than 5s,change SW1 mode
Function 3:
press 2x and hold for more than 5s,change SW2 mode
Function 6: press 5x change led parameter
Z-Wave Remote Control
ADD or Remove the ZW11 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
Include ZW11 to/from a Z-Wave Gateway with supporting Security.The ZW11 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.
Z-Wave MULTI_CHANNEL
ZW11 is multi channel device
,
It has three endpoints. Out-R1 is Endpoint1, Out-R2 is Endpoint2,Out-R3 is Endpoint3
ZW11 Endpoint1 / Endpoint2/ Endpoint3 Device Type
Generic Device Class: GENERIC_TYPE_SWITCH_BINARY
Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY
Z-Wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_MULTI_CHANNEL
---When prompted by your primary controller, click the Program button three times in one second.
Function 4: press 3x and hold for more than 5s,change SW3 mode
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 5: press 4x, then LED lit for 4s, within this time press 4x again – LED blinks 3 times then off to FACTORY RESET
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD

The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_MULTI_CHANNEL,
COMMAND_CLASS_CONFIGURATION
ZW11 protocol Endpoint 1
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY
ZW11 protocol Endpoint 2
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY
ZW11 protocol Endpoint 3
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY
Z-Wave Configuration Parameters
1:
Restores state after power failure
Paramter No: 1(0x01) Size:1 Byte Value: 00 All Relays OFF.
Value: 01 All relays remember the status prior to power outage and turns back to it (default);
Value: 02 All relays turned on after power failure
Value: 03 R1&R2 state recovered, R3 – OFF
Value: 04 R1&R2 state recovered , R3-ON
2
:
SW1 Type Select
Paramter No: 2(0x02) Size:1 Byte Value: 00 momentary switch
Value: 01 toggle switch (contact closed -ON, contact opened - OFF)
Value: 02 toggle switch(device changes status when switch changes status)(default)
You may use the below configuration parameters to change settings of the corresponding functionality.
Value: 02 toggle switch(device changes status when switch changes status)(default)
3
:
SW2 Type Select
Paramter No: 3(0x03) Size:1 Byte Value: 00 momentary switch
Value: 01 toggle switch (contact closed -ON, contact opened - OFF)
Value: 02 toggle switch(device changes status when switch changes status)(default)

4
:
SW3 Type Select
Paramter No: 4(0x04) Size:1 Byte Value: 00 momentary switch
Value: 01 toggle switch (contact closed -ON, contact opened - OFF)
Value: 02 toggle switch(device changes status when switch changes status)(default)
5:
LED indicator
Paramter No: 5(0x05) Size:1 Byte Value: 00 led OFF when output ON,led ON when output OFF(default)
Value: 01 led ON when output ON,led OFF when output OFF
Value: 02 led always OFF
Value: 03 led always ON
6:
Relay-1(EP1)Auto Turn-Off Timer
Paramter No: 6(0x06)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
7:
Relay-1(EP1)Auto Turn-ON Timer
Paramter No: 7(0x07)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
8:
Relay-2(EP2)Auto Turn-Off Timer
Paramter No: 8(0x08)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
9:
Relay-2(EP2)Auto Turn-ON Timer
Paramter No: 9(0x09)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
10:
Relay-3(EP3)Auto Turn-Off Timer
Paramter No: 10(0x0A)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
11:
Relay-3(EP3)Auto Turn-ON Timer
Paramter No: 11(0x0B)
,
Size=4
,
Value: 0
–
timer disabled ( default )
Values: 1 – 65535 (minutes)
12:
Realy-1(EP1)Manual Control
Paramter No: 12(0x0C) Size:1 Byte Value: 00 manual control disabled
Value: 01 manual control enabled (default)
13:
Realy-2(EP2)Manual Control
Paramter No: 13(0x0D) Size:1 Byte Value: 00 manual control disabled
Value: 01 manual control enabled (default)
Value: 01 manual control enabled (default)
14:
Realy-3(EP3)Manual Control
Paramter No: 14(0x0E) Size:1 Byte Value: 00 manual control disabled
Value: 01 manual control enabled (default)
Support for Association Groups
ZW11 supports 4 association groups. Group 1 support 1 node ID,Group
2,3,4
Support maximum of 5 node ID
’
s
Group 2 Mapping to EP 1 Association Group
2,
Group 3 Mapping to EP 2 Association Group
2,
Group 4 Mapping to EP 3 Association Group 2
Association group_1:Z-Wave Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW11 Status change report,
1. ZW11 will trigger AUTO report function if the Switch status had been changed.
Association group_2:basic set command
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command
command. On (0xFF) or Off (0x00) to its associated group.
Association group_4:basic set command
command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
ZW11 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
When the output of the ZW11 EP2 state is changed, On (0xFF) or Off (0x00). The ZW11 will automatically send out a related basic set
When the output of the ZW11 EP3 state is changed, On (0xFF) or Off (0x00). The ZW11 will automatically send out a related basic set
When the output of the ZW11 EP1 state is changed, On (0xFF) or Off (0x00). The ZW11 will automatically send out a related basic set
Other EVA Logik Relay manuals
Popular Relay manuals by other brands

Schweitzer Engineering Laboratories
Schweitzer Engineering Laboratories SEL-221F instruction manual

Omron
Omron Sti SR120MP operating instructions

Pilz
Pilz PNOZ X3.2 operating instructions

Siemens
Siemens SIRIUS Original operating instructions

Leviton
Leviton GreenMAX RELAY-1TB installation manual

Omron
Omron K8AB-TH product manual