EVA Alto infinity User manual

Read this manual carefully before use and keep it for future reference.
Failure to do so may result in injury, property damage and may void the
warranty.

02 En
02 • • Contents
02 • • Languages
03 • • Important instructions
04 • • Quick start guide
04 • • • Setup
04 • • • Air quality display
05 • • • Touch panel controls
06 • • • Parts guide
07 • • • LCD displays
08 • • • Filters
09 • • • Sensors
• • Contents

03En
• • Important instructions
WARNING: THIS APPLIANCE CONTAINS MAGNETS
01.
contact with the device.
02. Credit cards and electronic storage media may be affected by magnets and
should be kept away from the top of the appliance.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
03. Disconnect power or unplug before cleaning, performing any maintenance or
04. This appliance is not intended for use by persons with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
05. Children should be supervised to ensure that they do not play with the appliance.
06. Do not use this appliance in the immediate surroundings of a bath, shower,
swimming pool or any other source of water.
07. To avoid overheating, do not cover the appliance.
08. If the supply cable is damaged, it must be replaced or repaired by the
09. Do not use this appliance in small rooms when they are occupied by persons
not capable of leaving the room on their own, unless constant supervision is
provided.
10. Do not use outdoors or on wet surfaces and do not handle any part of the
appliance or plug with wet hands.
11.
12. Do not use this appliance if it has been damaged or submerged in water.
13. Do not use this appliance if it has been dropped or if it has visible signs of
damage.
14. Keep this appliance and cable away from heated surfaces. Do not position the
cable under furniture or appliances.
15.
shock.
16.
17.
replace the socket.

04 En
• • • Setup
• • • Air quality display
Before use, be sure to remove all packaging from the unit
Remove the tape from the UV lights.
removed.
Position so the sides and back are free from obstructions to
glows red. Power on and choose your settings.
The air quality colour display indicates the air quality measured before
Blue
0-50
Perfect
Green
51-100
Normal
Purple
101-150
Poor
Red
151+
High Risk
50cm
50cm
10cm
• • Quick start guide

05En
• • • Touch panel controls
UV.
pathogens and viruses.
Ioniser. Emits ions which cause airborne
pollutants to gain weight and drop from the air.
Reset.
has been changed.
Speed. Affects how fast air is drawn through the
lights illuminated.
Timer. Choose between a 1/ 2 / 4 / 8 hour timer.
standby mode when the set time has passed.
Power.
‘on’ and ‘standby’.
Auto. Will use current air quality data to adjust fan
speed.
Sleep. Sets fan to minimum speed and dims
displays.
RESET
FUNCTION
SPEED
ON/OFF

06 En
• • • Parts guide
01. Clean air outlet
02. Touch panel controls
03. Top LCD display
04. Back cover open handle
05. Air intake
06. Side LCD display
07. Air quality sensor
08.
09.
10.
11.
02
04
06 07
05
01
08 09 10 11
03

07En
• • • LCD displays
13
14
16
17
15
12
19
23
21
19
22
14
20
20
12
18
12.
13. Filter replace symbol
14. Air temperature
15. Auto mode active
16. Fan speed
17. Sleep mode active
18. Air quality colour display
19. Air quality readout
20. Air humidity
21. UV light symbol
22. Ioniser symbol
23. Light sensor
Top LCD display
Side LCD display

08 En
• • • Filters
placing the tag facing out as you install in the following order.
Pre-screen lter
Uses a micron mesh to block particles down to
2.5mm. This acts as a shield which can be easily
Photo catalyst lter
A large photo catalyst honeycomb lattice acts like
Did you know:
to last a lifetime so they do not need to be replaced. The pre-screen
True HEPA lter
as small as 0.3 microns.
Active carbon lter
Ultra porous activated carbon granules absorb
harmful chemicals, gases and odours.

09En
• • • Sensors
Light sensor
When in auto mode, the light sensor detects when it’s
dark and will enter sleep mode by dimming the lights
and setting the fans to silent.
Temperature & humidity sensor
Gives accurate indoor temperature and humidity
information.
Air quality sensor
Uses a laser to detect particle interference in non-
The sensor should be cleaned every 2-3 months to
ensure accurate readings.
Use a soft
brush to clean
the sensor
vents.
Lightly clean
sensor with
wet cotton
swabs and
dry with dry
cotton swabs.

10 En
• • Specifications
75
CADR 550
118
25
456x230x640
11.5

11En
• • CE Certificate
EU Declaration of Conformity
We hereby declare that the machine described below complies with the relevant
basic safety and health requirements of the EU Directives, both in its basic design
and construction as well as in the version put into circulation by us. This declaration
As authorised by:
Declares that:
Description:
Identication code:
Conforms to the following directives and standards:
• 2014/35/EU - Low Voltage Directive
•
• 2011/65/EU, 2015/863 - RoHS Directive
Harmonized standards applied:
EN 55014-1:2017, EN 61000-3-2:2014, EN 61000-3-3:2013, EN
55014-2:2015, EN 301 489-1 V2.1.1, EN 301 489-17 V3.1.1, EN
300 328 V2.1.1, EN 62311:2008, EN 300 328 V2.1.1.
Notied body:
The technical documentation is kept by:
Date: 01/10/2020
Signed:
PR6 9FE, United Kingdom
Table of contents
Other EVA Air Cleaner manuals
Popular Air Cleaner manuals by other brands

RoboVent
RoboVent Spire MLS-01-5500-10 owner's manual

AIR SYSTEMS
AIR SYSTEMS BB15 Series OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

EcoQuest
EcoQuest Ozone Blaster 5G user manual

Sharp
Sharp FZ-6400SF Operation manual

Surgically Clean Air
Surgically Clean Air DE 2.0 Operation manual

Sharp
Sharp FZ-560HF quick start guide